| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 18-12-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 25-12-2024 |
| Sl. No. | Item Description |
| 1 | Disconnecting of water connection and dismantling complete solar water heating system of capacity 300 ltrs per day including hot & cold water pipes and hot water tank complete and refixing after repairing the system fixing back in position and testing complete all as specified and as directed.Notes : Rates quoted by the contractor shall deemed to be included for :-(a) Making good the worn out missing nuts bolts, washers, union, sockets, flanges and screws etc.(b) Descaling/ desludging, cleaning and washing of the solar panel, hot water pipes, copper tubes, hot and cold water tanks by using appropriate chemicals and re-assembling the panel including welding of collector fins as required.(c) Painting of staging, solar panel frame, hot water tank frame with applying one coat of synthetic enamel paint including preparation of old painted steel surfaces of any description(e) All other materials shall be measured and paid separately under respective items. |
| 2 | All as per items No 01 here in before but of capacity 200 ltrs per day complete all as specified and as directed. |
| 3 | All as per items No 01 here in before but of capacity 100 ltrs per day complete all as specified and as directed. |
| 4 | Supply only solar energy collector panel made of aluminium body with toughened glass complete with copper fins of capacity upto 300 ltrs per day complete all as specified and as directed. |
| 5 | Supply only as in replacement, solar panel toughened glass having thickness 5mm all as per the existing model of system complete all as specified and as directed. |
| 6 | Supplying only as in replacement, solar panel gasket made out of fine rubber to make system air tight, dust and water proof complete all as specified and as directed. |
| 7 | Supply only as in replacement, copper tubes with collectors fins for solar energy collector panel complete of same dia and thickness as per existing, brazing by copper alloy brazing rod with the existing inlet/outlet hot/cold water pipes to make the panel water tight complete all as specified and as directed. |
| 8 | Supply only compressed glass wool 48 mm thick between solar energy collector panel copper tubes frame and aluminum body panel including securing it on panel by means of necessary adhesives complete all as specified and as directed. |
| 9 | Supply only solar energy collector panel manifold 1.40 mtr long, made of 20mm dia copper tube having 1 No MS flange 74 mm dia welded at each end duly drilled for nuts & bolts complete all as specified and as directed. Note : Rate quoted deemed to be included for welding of solar collector tubes with manifold all as directed and as recomended by manufacturer. |
| 10 | S&F hose pipe for hot/ cold water for solar system of suitable length as existing size complete with 02 Nos MS clamps complete all as specified and as directed. |
| 11 | Supply only auxillary tank for make up tank to reduce pressure of solar system complete all as specified and as directed. |
| 12 | S&F Electrical backupheater of 2 KW for solar system with all electrical connection complete all as specified and as directed. |
| 13 | S&F Electrical backup heater of 3 KW for solar system with all electrical connection complete all as specified and as directed. |
| 14 | Descaling solar energy collector panel made of aluminium body with toughened glass complete with copper fins of capacity 100/200/300 ltrs per day complete all as specified and as directed. |
| 15 | Descaling of hot water storage tank of food grade stainless steel 100 ltr capacity complete all as specified and as directed. |
| 16 | Descaling of hot water storage tank of food grade stainless steel 200 ltr capacity complete all as specified and as directed. |
| 17 | Descaling of hot water storage tank of food grade stainless steel 300 ltr capacity complete all as specified and as directed. |
| 18 | M&L for insulation of hot water pipe with glass wool and covering with aluminium sheet cladding 25 gauge for 20mm bore GI pipe complete all as specified and as directed. |
| 19 | S & F rotational moulded polythene water storage tanks triple layers, white colour (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR part I of capacity 500 Litres including dismantling of existing one complete all as specified and as directed. |
| 20 | S & F in repairs ball brass valves high pressure with polythene float and fly nuts complete, screwed for iron pipe and fixed 15mm bore complete all as specified and as directed. |
| 21 | S & F in repair ball brass valve 20mm bore dia high pressure with polythene float and fly nuts complete screwed with iron pipe and fixed complete all as specified and as directed. |
| 22 | S & F in repairs gun metal globe or gate valve 20mm bore with iron wheel head, screwed both ends for iron pipes 20mm bore complete all as specified and as directed. |
| 23 | S & F in repairs gun metal globe or gate valve 15mm bore with iron wheel head, screwed both ends for iron pipes 15mm bore complete all as specified and as directed. |
| 24 | S & F in repairs glass wool insulation with aluminium cladding for 25 mm bore pipecomplete all as specified and as directed. |
| 25 | Supply and filling distilled water to solar geyser for various capacitycomplete all as specified and as directed. |
| 26 | GEYSER |
| 27 | Taking down the existingunserviceable storage type electric water heater (geyser) of any make/ capacity, installed at different location including dis-connecting, taking down opening all parts/accessories for inspection, cleaning, descaling, refixing serviceable parts, replacing unserviceable partsinstalled at old location and reconnection, testing complete all as specified and as directedfor the follwoing capacity :- 25 Ltr capacity. |
| 28 | All as per item No 27 above but35 Ltr capacity complete all as specified and as directed. |
| 29 | All as per item No 27 above but50 Ltr capacity complete all as specified and as directed.Notes :-(a)The rates of item No 27 to 27.02 above deemed to include thelabour charges for fixing of new parts as required .The new parts requiredshall be paid as supply only under respective item of Schedule \"A\". (b) Serviceable materials obtained from item No 27 to 27.02 above shall be refixed and labour charges for the same are included in unit rate of Item No 27 to 27.02 above. |
| 30 | Supply only heating element round type of geysers including rubber washer for the following capacity :- (a)1500 Watt capacity |
| 31 | All as per Item No 28 above but 2000 Watt capacity. |
| 32 | Supply only PVC connection pipe with brassunions at both ends, 450mm long 15mm bore (for incoming cold water) complete all as specified and as directed. |
| 33 | Supply only chromium plated copper connection pipe 450mm long with two brass adopters washers and connecting up complete all as specified and as directed. |
| 34 | Supply only apparatus plate suitable for 25 ltrs capacity geyser complete all as specified and as directed. |
| 35 | Supply only apparatus plate suitable for 35 ltrs capacity geyser complete all as specified and as directed. |
| 36 | Supply only apparatus plate suitable for 50 ltrs capacity geyser complete all as specified and as directed. |
| 37 | Supply onlythermostat (ISI Marked) for 25/35/50 Liters capacity Geyser complete all as specified and as directed. |
| 38 | Supply onlythermostat (ISI Marked) for 25/50 Liters capacity Geyser for Racold geysers complete all as specified and as directed. |
| 39 | Supply only steel tanks 25 liters and refixing after testing the leakage complete includingreplacement ofinsulating material (Glass wool) for 25 Liters capacity Geysers and replacement ofrubber packaging ring heat resistsnt typecomplete all as specified and as directed. |
| 40 | Supply only steel tanks 35 liters and refixing after testing the leakage complete includingreplacement ofinsulating material (Glass wool) for 35 Liters capacity Geysers and replacement ofrubber packaging ring heat resistsnt typecomplete all as specified and as directed. |
| 41 | Supply only steel tanks 50 liters and refixing after testing the leakage complete includingreplacement ofinsulating material (Glass wool) for 50 Liters capacity Geysers and replacement ofrubber packaging ring heat resistsnt typecomplete all as specified and as directed. |
| 42 | Supply & Fixing Plug top, 3 pin, 15 amps, 230 volt, including electric connection after taking out old unserviceable one complete complete all as specified and as directed. |
| 43 | S&F stop valve, brass, 15mm bore after taking out defective/ unserviceable one complete all as specified and as directed. |
| 44 | M&L for sub main wiring with 2 run of 4.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts gradewith stranded copper conductor includingone run of 4.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in 25mm dia PVC rigid non- metallic conduit withcomplete all as specified and as directed. Note: Two runs of conductor copper and one run of earth conductor and one run of PVC pipe shall be measured and paid as one unit separately. |
| 45 | M&L for sheet metal enclosure MCB distributon board, 2 way single door 230 volts complete all as specified and as directed. |
| 46 | S&F in replacement safety nut for pressure release valve complete all as specified and as directed. |
| 47 | S&F in replacement hole fastener 10 mm dia, 100 mm long including nut and washer complete all as specified and as directed. |
| 48 | S&F non return valve 15mm dia and over as required complete all as specified and as directed. |
| 49 | S&F in replacement rubber gas Kit suitable for 50/25 ltrs capacity geyser complete all as specified and as directed. |
| 50 | M&L for fixing of new/old geysers at new place with hole fastener and cement work including connection with existing pipes complete all as specified and as directed. |
| 51 | FANS |
| 52 | Taking down ceiling fan any size from its location includingdisconnecting fromceiling rose, after removingcarefully false celing/ ceiling wherever necessary and removing blades, opening of fan and cleaning ofbush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing,locking nut, screw, split pin, check nut, rubber realwherever required tighteningof stator up and bottom cover in position; washing body, blades, canopieswith detergent soap powder; preparation of old painted surfacesby filling cavaties with suiatble filler and applying one coat of spray painting to fan(white or any other approved shade)and writing MES No. etc ,testingand re - hanging fan and false ceiling in position and making electric connection complete all as specified and as directed. Note: Spares wherever required to be renewed shall be measured and paid vide under respective item as supply only. |
| 53 | Material and labour for removing the defective/burnt ceiling fans winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, withrequired Number of turns and including all insulating material s such as insulating tape,cloth and sleeves, varnishing and drying, greasing amd making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts andtesting and brouught at site complete all as specified and as directed. Note: Winding shall be carried out by winding machine. |
| 54 | Taking down exhaust fan 300/380/450 sweep of any size from its location includingdisconnecting fromceiling rose, after removing carefully wall wherever necessary and removing blades, opening of fan and cleaning ofbush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing,locking nut, screw, split pin, check nut, rubber realwherever required tighteningof stator up and covers in position; washing body, blades, with detergent soap powder; preparation of old painted surfacesby filling cavaties with suiatble filler and applying one coat of spray painting to fan(white or any other approved shade)and writing MES No. etc ,testingand refixing fan to wall in position and making electric connection complete all as specified and as directed. Note: Spares wherever required to be renewed shall be measured and paid vide under respective item as supply only. |
| 55 | Material and labour for removing the defective/burnt Exhaust fans of sweep 380/450 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, withrequired Number of turns and including all insulating material s such as insulating tape,cloth and sleeves, varnishing and drying, greasing amd making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts andtesting and brouught at site complete all as specified and as directed. Note:Winding shall be carried out by winding machine. |
| 56 | Material and labour for removing the defective/burnt Exhaust fans of sweep 300 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, withrequired Number of turns and including all insulating material s such as insulating tape,cloth and sleeves, varnishing and drying, greasing amd making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts andtesting and brouught at site complete all as specified and as directed. Note: Wnding shall be carried out by winding machine. |
| 57 | Taking down wall mounted / padestal fan of 600mm sweep any size from its location includingdisconnecting fromceiling rose, after removingcarefully false celing wherever necessary and removing blades, opening of fan and cleaning ofbush / ball bearing with kerosine oil, filling up ball bearing with grease and mobile oil and changing of capacitor, bush bearing,locking nut, screw, split pin, check nut, rubber realwherever required tighteningof stator up and covers in position; washing body, blades, with detergent soap powder; preparation of old painted surfacesby filling cavaties with suiatble filler and applying one coat of spray painting to fan(white or any other approved shade)and writing MES No. etc ,testingand re - hanging fan and false ceiling in position and making electric connection complete all as specified and as directed. Note: Spares wherever required to be renewed shall be measured and paid vide under respective item supply only. |
| 58 | Material and labour for removing the defective/burnt pedestalfans of sweep 600 mm of any make and type stator winding of any description, cleaning the core stator, rewinding the stator coil with super quality, super enameled copper wire of suitable gauge and approved Make, withrequired Number of turns and including all insulating material s such as insulating tape,cloth and sleeves, varnishing and drying, greasing amd making necessary connection for looping wire with stranded copper conductor and refixing the same in original position including greasing of bearings & other moving parts andtesting and brouught at site complete all as specified and as directed. Note: Wnding shall be carried out by winding machine. |
| 59 | S&F in replacement of ball bearings No 6201,6202,6203, 6204 or any other size required for old vintage ceiling fans / exhaust fans/ pedastal fans complete all as specified and as directed. |
| 60 | S&F in replacement of bronze bush of suitable size for ceiling fans of any size and make including greasing with approved quality of grease complete all as specified and as directed. |
| 61 | S&F in replacement of capacitor 2.5/4.0 mfd for ceiling fan complete all as specified and as directed. |
| 62 | S&F in replacement of capacitor 4.0 mfd for ceiling fan complete all as specified and as directed. |
| 63 | S & F fan shaftsuitable for motor of ceiling fan 1200/1400 mm sweep complete all as specified and as directed. |
| 64 | S&F in replacement of PVC connector block 4 way with fixing nuts and clamps complete all as specified and as directed. |
| 65 | M&L for painting of ceiling fans including blades with applying two coats of synthetic enameled paintover a coat of red oxide primer by using spray painting machine on old prepared surface including writing of MES No using synthetic enamel paint black colourcomplete all as specified and as directed. |
| 66 | Supply and fixing upper canopy and down canopy for ceiling fans suitable for any make and sweep complete all as specified and as directed. |
| 67 | Supply and fixing in repair hanging clamp suitable for ceiling fans of any make and type with rubber real, nuts, bolts and washers of suitable size including locking pin complete all as specified and as directed. |
| 68 | S&F in replacement of metal fan blade suitable for ceiling fan 1200 mm sweep complete all as specified and as directed. |
| 69 | S&F in replacement of metal fan blade suitable up to 300 mm sweep Exhaust fancomplete all as specified and as directed. |
| 70 | S & F in replacement of PCB Card for BLDC Remote Fan(Energy efficient)complete all as specified and as directed. |
| 71 | Taking down carefully old/unserviceable copper/alluminium any type of point wiring for one light, socket, fan, bell or power etc including all fittings such as switches sockets, holders, light fittings, fan requlators, call bell etc and making good the disturbed surface of wall ceiling complete all as specified and as directed. |
| 72 | M&L for Consealed type Point wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core malti stranded copper FRLS cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in including PVC conduit of adequate size having a wall thickness not less than 1.5 mm with allaccessories (including cutting chases & making good the disturbed surface to its original specification)including 1.5 sq mm (nominal cross sectional area) PVC insulated unsheathed single core multistranded copper conductor FRLS cable as earth continuity conductor connected to main switches/DB\"s or common earth dolly complete all as specified and as directed for the following :- |
| 73 | One light point controlled by one way switch 5/6 amps complete all as specified and as directed. |
| 74 | One ceiling fan/Exhaut fan point controlled by one way switch 5/6 amps complete all as specified and as directed. |
| 75 | One socket out let 5/6 amps point on the independent board complete all as specified and as directed. |
| 76 | One socket out let 5/6 amps point on the same board complete all as specified and as directed. |
| 77 | One bell/buzzer point controlled by one bell push button complete all as specified and as directed. |
| 78 | One light point controlled by two way switch 5/6 amps complete all as specified and as directed. |
| 79 | All as per item No 69 above but wiring with 2.5 sq mm single core multistranded copper conductor for one socket out let 15/16 amps point on the independent board complete all as specified and as directed. |
| 80 | S&F in repair switch piano flush type 5/6 amps single pole one way complete all as specified and as directed. |
| 81 | S&F switch piano flush type 5/6 amps single pole two way complete all as specified and as directed. |
| 82 | S&F socket 2 in 1, 5 Pin, 5/6 amps, white ivory finish flash type complete all as specified and as directed. |
| 83 | S&F of socket outlet 2 in 1, 5 Pin 5/15 Amp multipurpose 230 volt flush type ccomplete all as specified and as directed. |
| 84 | S&F in repair switch piano flush type 15/16 amps single pole one way complete all as specified and as directed. |
| 85 | S&F in repair Switch socket combination2 and 3 Pin, 5/6 amps, multipurpose flush non shutter, non inter locking type white ivory finish with and including taking down existing unserviceable complete all as specified and as directed. |
| 86 | S&F in repairswitch socket combination 2 in 1, 6 pin 5/6 amps and 15/16 amps multipurpose, white/ivory finish flush non shutter non inter locking type with and including taking down existing unserviceable complete all as specified and as directed. |
| 87 | S&F in repair bell/buzzer push 5/6 amps flush type white/ivory finish complete all as specified and as directed. |
| 88 | S&F in repair ding dong bell multi music type, AC, Single pole, 220/240 Volts, surface type complete all as specified and as directed. |
| 89 | S&F in repair ceiling rose, bakelite, surface type, 220/240 volts, three terminals complete all as specified and as directed. |
| 90 | S & F in repair lamp holder, insulated body, with back plate suitable for batten/anglefittings complete all as specified and as directed. |
| 91 | S & F in repair deluxe fan Electronic regulator 120/280 volts AC 50 Hzs rotary stepwhite/ivory finish complete all as specified and as directed. |
| 92 | S&FLED white glass Lamp 1x9 Watt 230V Base-22 complete all as specified and as directed. |
| 93 | S&F in repair modular switch 6 Amp one module complete all as specified and as directed. |
| 94 | S&F in repair modular swith 16 Amp one module complete all as specified and as directed. |
| 95 | S&F Modular socket 6 Amp 2/3 Pin combined 2 module 230 volt flush type complete all as specified and as directed. |
| 96 | S&F Modular socket 6/16 Amp2/3 Pin combined2 module 230 volt flush type complete all as specified and as directed |
| 97 | S & F in repair modular fanregulator 120W 230volts AC 50 Hz 2 modules complete all as specified and as directed. |
| 98 | S&F IP 20, class I, LED light 1X18 W (or nearest next higher wattage) (4feet), 5700K, wall/ surface mounted, integrated type with aluminium housing and decorative and caps with integrated high efficiency electronic driver and surge suppressor of 2KV or more, luminaire efficiency > 95 lumens/watt, power factor > 0.90, operating range - 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/ square blocks, screws etc complete with all accessories internally prewired and connecting up with and including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 99 | S&F IP 20, Class I, LED Mirror light fitting 1 x 9 W, (or nearest next higher wattage) 5700 K, wall /Surface mounted with aluminium housing 2 feet long, integrated type, with high efficiency PMMA diffuser,integrated high efficiency electronic driver & surge suppressor of 2 KV or more, luminaire efficacy > 95 lumens/Watt, power factor >/ 0.90, operating range – 140 to 270 V, 50 Hz fixed with 02 Nos of PVC round/square blocks, screws etc complete including 01 No 10 W LED lamp with all accessories internally prewired and including connecting up with and including twin core twisted flexible copper conductor cable of suitable size including necessary taking down the old unserviceable fitting complete all as specified and as directed. |
| 100 | S & F Post top lanterns 20 watt LED light fitting(Warm type) ,outdoor new generation, energy saving, environmental friendly, longlife with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source, spun aluminium canopy, with opal/clear acrylic diffuser and complete with all accessories intenally prewired including connecting up with three core twisted flexible copper conductor cable up to cealing rose and necessary mounting arrangement including taking down old one complete all as specified and as directed. |
| 101 | S & F Recess mounting flat panel 35/36 Watt LED fitting (2\"X2\") for armstrong/ grid ceiling, white powder coated CRCA housing complete with full window acrylic diffuser & electronic driver, high brightness SMD LEDs etc complete with all accessories internally prewired and necessary mounting arrangements, including necessary connection including taking down the old one complete all as specified and as directed. |
| 102 | S & F Energy saving new generation environmental friendly long life versatile presure die cast aluminium IP 66 security light fitting luminaire with high power LEDs as light source and electronic driver of capacity 25 watts with pre wired andnecessary mounting arrangements, provision of new 3 core multistrandedcopper conductor of size 23/0.193 from ceiling rose to fitting and GI pipe bracket made out of GI pipe medium grade 32 mm dia 1.5 mtr long bend to required shape complete including removal of old unserviceable fitting complete all as specified and as directed. |
| 103 | M&L for sub main wiring with 2 run of 6.00 sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS cable of working voltage 1100 volts gradewith stranded copper conductor includingone run of 6.00 Sqmm (nominal cross sectional area) PVC insulated unsheathed cable with stranded copper conductor as continuous earth wire connected to common earth dolly drawn in PVC rigid non- metallic conduit with and including taking down unserviceable sub main complete all as specified and as directed. Note: Two runs of submain wiring cable alongwith one run of earth wire with and including 25 PVC conduit pipe shall be measured as one unit length). |
| 104 | S&F Sheet metal enclosure for 4 way Distribution Boards (DB’s), double door, Triple pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\"S/lsolators complete with and including taking down old unserviceable one complete all as specified and as directed. |
| 105 | S & F in replacement MCB TPN 415 volts suitable for fixing in MCB DB of capacity 40 to 100 amps complete all as specified and as directed. |
| 106 | S&F Sheet metal enclosure for 8 way Distribution Boards (DB’s), double door, single pole & neutral with 200 amps rated bus bar, IP-20 protection suitable for fixing MCB\"S/lsolators complete with and including taking down old unserviceable one complete all as specified and as directed. |
| 107 | S&F MCB, Single pole & neutral, 5 to 32 amps, 240 volts, ‘C’ curve, 10KA allcomplete with and including taking down old unserviceable one complete all as specified and as directed. |
| 108 | S&F MCB, Single pole & neutral, 40 to 63 amps, 240 volts, ‘C’ curve, 10KA allcomplete with and including taking down old unserviceable complete all as specified and as directed. |
| 109 | S&F MCB, Single pole, 5 to32 amps, 240 volts, ‘C’ curve, 10 KAall complete with and including taking down old unserviceable one complete all as specified and as directed. |
| 110 | Taking down the existing unserviceable main switch/ cut out/ DBs of any type/ capacity/ description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed. |
| 111 | Taking down the existing unserviceable sub main wiring of any type / description as existing at site including making good the disturbed surfaces to match with the existing finishes complete all as specified and as directed. |
| 112 | M&L forpoint wiring with 1.5 Sqmm (nominal cross-sectional area) PVC insulated unsheathed single core FRLS copper cable working voltage 1100 volts grade conforming to IS-694 with stranded copper conductor in and including PVC conduit of adequate size with allaccessories (including cutting chases & making good the disturbed surface to its original specification) including size 1.5 sqmm (nominal cross sectional area) PVC insulated single core multistranded copper conductor cable as earth continuity conductor connected to main switch/DB\"s or common earth dolly, including wiring from DB to switch board with 2.5 sqmm FRLS multistranded copper cable for one flame proof light point controlled by one rotary type swtich 15/16 amps complete all as specified and as directed. |
| 113 | S&F switch flameproof rotary type with termination box in LM6 16A, double pole 250V complete all as specified and as directed. |
| 114 | S&F LED flame proof light fitting 1 x 16 watt, CMRI certified recommended for gas/vapor group IIA & IIIB, zone 1 & 2 and IP 65 protection with die cast aluminium housing with heat resistant toughened glass with LED tube light fixure driver, holders, connectors etc complete with all accessories prewired and including connecting up with three core flexible copper conductor cable mounting arrangement including taking down old unserviceable lights complete all as specified and as directed. |
| 115 | S&F in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 20 mm x 3 mm thick, copper strip using porcelain clit/post insulators complete all as specified and as directed. |
| 116 | S&F in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32 mm x 6mm thick, copper strip using porcelain clit/post insulators complete all as specified and as directed. |
| 117 | S&F in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 25mm x 4mm thick, galvanised iron strip using porcelain clit /post insulators complete all as specified and as directed. |
| 118 | S&F in repair for earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required for 32mm x 6mm thick, galvanised iron strip using porcelain clit /post insulators complete all as specified and as directed. |
| 119 | S&F in repair earth continuity conductor or main earthing lead fixed to wall on batten or recess or chases or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 4mm dia galvanised iron or steel wire complete all as specified and as directed. |
| 120 | S&F aluminium strip of size 25x3.15 mm for earth continuity conductor fixed on PCC block complete all as specified as directed. |
| 121 | S&F porcelain insulator of size 65x31 mm and height 30mm with three nos hole including GI bolts and nuts of required size and two nos washer on PCC, fixing strip complete all as specified and as directed. |
| 122 | S&F air termination single pointed aluminium rod 12mm dia and 300 mm height/length complete all as specified and as directed. |
| 123 | M&L for cement concrete (1:3:6) type C-1 using 20mm graded stone aggregate and finishing the surface even and smooth without using extra cement for making PCC block of any sizecomplete all as specified and as directed. |
| 124 | M&L for 20 mm bore steel tubing light grade ISI marked for lightning protection including necessary joint complete all as specified and as directed. |
| 125 | S&F test point terminal block made of gun metal or phosphorus bronz size 75 x 75 x 25 mm drilled and screwed including 3 nos 8mm dia 25mm long hexagonal head screw complete all as specified and as directed. |
| 126 | Taking down old unserviceable Earthing pit of any type with accessories including removing of dismantled/demolished material from work site at any distance out side MD land complete all as specified and as directed. |
| 127 | M&L for earthing complete with galvanized steel plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of the earth plate not less than 1.5 m below ground level connected to GI earth strip 25 x 4mm thick by means of nuts, bolts, check nuts and washers galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft/loose soil, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40mm bore GI light grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8mm dia TMT bars @10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer, charcoal and testing on completion, complete all as specified and as directed.Notes :-(a) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate as per colour code followed in Station.(b) If the desired earth resistance is not achieve during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible. |
| 128 | M&L for earthing complete with galvanized steel plate electrode of size 60cm x 60cm x 6mm thick buried directly in ground (earth pit not less than 2.25m below ground level) with top edge of the earth plate not less than 1.5 m below ground level connected to GI earth strip 20 x 3mm thick by means of nuts, bolts, check nuts and washers galvanized iron or steel all as shown in electrical plate No 3 of SSR Part-I, connected to earth test point all as specified or indicated including excavation and connected earth work in soft/loose soil, PCC 1:3:6 type C1 as in pit, 20mm dia GI pipe medium grade for watering pipe, 40mm bore GI light grade earth lead protection pipe, 50mm thick RCC 1:2:4 type B1 cover slab of earth pit reinforced with 8mm dia TMT bars @10cm C/C both ways and with handle made out of 10mm dia bars, funnel, strainer, charcoal and testing on completion, complete all as specified and as directed.Notes :-(a) The earthing pit should be provided with proper earth pit and pit cover. Pit cover should be painted with synthetic enamel paint of approved colour and pit number to be marked on a GI plate as per colour code followed in Station.(b) If the desired earth resistance is not achieve during testing as per IS the complete earthing shall be carried out by the contractor at his own cost and no extra claim shall be admissible. |
| 129 | M&L for 20 mm bore steel tubing light gradefor laid in trenches including taking down of existing pipes and removal from site complete all as specified and as directed. |
| 130 | M&L for 25 mm bore steel tubing light grade ISI marked for laid in trenches including taking down of existing pipes and removal from site complete all as specified and as directed. |
| 131 | M&L for 40 mm bore steel tubing light gradewith all fittings fixing on top of the building for fixing air termination/strip protectionincluding taking down of existing pipes and removal from site complete all as specified and as directed. |
| 132 | M&L for 50 mm bore steel tubing light grade forprotection strip including taking down of existing pipes and removal from site complete all as specified and as directed. |
| 133 | M&L for checking of existing old earth pits and lightning conductors and repairs/replacement ofAluminum strip/GI Strip/Copper strip where founded corroded and repairs to pits and testing of earth resistance value and pouring salt/charcol for obtaining earth value below 05 ohm complete all as specified and as directed. |
| 134 | M&L for Earthing complete with galvanised steel earth plate electrode 600x600x6.0 mm thick buried directly in ground (earth pit not less than 2.25 mtr deep below the ground level) with top edge of the plate not less than 1.5 mtrs below normal ground level, connected to galvanised earth lead wire 4.0 mm dia by means of bolts, nuts, check nuts and washers of galvanised iron or of steel all as shown in electrical plate No 3 of SSR part-I2009 connected to pole/LT Panel all as specified and testing on completion including, necessary excavation, earthwork, PCC works and CI earth pit cover with watering pipe 20mm dia GI pipe medium grade, funnel with wire mesh and lugs and GI pipe 40 mm dia of light grade,for protection of earth strip including dismantling of old earthing complete all as specified and as directed. Note: Excavation/PCC/Earth work/Charcoal/ Salt shall be deemed to be include in this unit rate. |
| 135 | S & F switch piano single pole flush type 5 amps, one way, 230 volts complete all as specified and as directed. |
| 136 | S & F bell push flush type 5 amps, 230 volts complete all as specified and as directed. |
| 137 | S & Fsocket combination flush type multipurpose 2/3 pin 5 amps 2 in 1, 230 Volts complete all as specified and as directed. |
| 138 | S & F switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1230 Volts complete all as specified and as directed. |
| 139 | S & F switch socket combination 2 in 1 multipurpose 3/5 pin 5/15 Amps flush type complete all as specified and as directed. |
| 140 | S & F ceiling rose three terminal surface bakelite type AC 50 Hz 230 volts of size 65 x 50 mm complete all as specified and as directed. |
| 141 | S & F ceiling fan regulator step type, flush type heavy duty suitable to work on 230 volts Ac supply complete all as specified and as directed. |
| 142 | S & F lamp holder insulated body surface bakelite with back plate suitable for angle / batten fittings fixed with PVC round/square blocks complete all as specified and as directed. |
| 143 | S & F in repair switch piano single pole flush type 5 amps, two way, 230 volts complete all as specified and as directed. |
| 144 | S & F in repair switch socket combination flush type multipurpose 2/3 pin 5 amps 2 in 1230 Volts complete all as specified and as directed. |
| 145 | S & F in repairswitch socket combination 2 in 1 multipurpose 3/5 pin 5/15 Amps flush type complete all as specified and as directed. |
| 146 | S&F epoxy powder coated sheet metal enclosure with socket plug top and MCB, single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB 32 Amps, 240 Volts, C Series current carrying capacity 10 kA, including necessary connection and taking down old one complete all as specified and as directed. |
| 147 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductorof size 4 Sqmm standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circularcomplete all as specified and as directed. |
| 148 | Supplying and fixing 1100 volts grade heavy duty cable PVC insulated aluminium conductorof size 6 Sqmm standard conductor, served with inner sheathing of PVC tape and overall PVC sheathed in service connections suspended by insulating hangers not more than 1 metre apart including 4mm suspension wire, one twin core cable flat or circularcomplete all as specified and as directed. |
| 149 | S&F in repairhylam sheet 3 mm thick white in colour of size 130 mm x 180 mm including taking down existing unserviceable complete all as specified and as directed. |
| 150 | S&F in repair hylam sheet 3 mm thick white in colour of size 120 mm x 170 mm including taking down existing unserviceable complete all as specified and as directed. |
| 151 | S&F in repair hylam sheet 3 mm thick white in colour of size 230 mm x 280 mm including taking down existing unserviceable complete all as specified and as directed. |
| 152 | S&F in repair hylam sheet 3 mm thick white in colour round type of size 80 mm dia including taking down existing unserviceable complete all as specified and as directed. |