Tender Details

Repair Maint Of Lt Network At Tech Area At Af Stn Jodhpur , Disconnecting And Taking Out Unserviceable Voltmeter Of Any Description And Supply, Fixing, Connecting, Testing And Commissioning Of Digital Electronic Voltmeter (0-500V) Range With Inbuilt Selector Switch Suitable For Lt 415 Volts 50Hz Ac Supply Panel Board Flush Pattern, Square Type 96 Mm X 96 Mm With Adopter Including Connected Wiring With 1.5 Sqmm Pvc Insulated And Sheathed Copper Conductor Cable ( Frls ) Complete All As Specified And Directed By Engineer-In-Charge. , Disconnecting And Taking Out Unserviceable Amp Meter (0- 400) Amps Rating Of Any Description And Supply, Fixing, Connecting, Testing And Commissioning Of Digital Electronic Amp Meter Suitable As Per Existing Amp Rating Alongwith New Ct Of Suitable Ct Ratio (Ryb-01 Set) And In Built Selector Switch Suitable For Lt 415 Volts 50Hz Ac Supply Panel Board Flush Pattern, Square Type 96 Mm X 96 Mm With Adopter Including Connected Wiring With 1.5 Sqmm Pvc Insulated And Sheathed Copper Conductor Cable ( Frls ) Complete All As Specified And Directed By Engineer-In-Charge. , S&F In Repairmulti Functional Led Type Digital Meter Suitable For Measuring Electrical Parameters I.E, Ampere, Voltage, Frequency, Power And Power Factor,Thd Etc3 Phase Class 1 Ac With Epoxy Type Ct Suitable Ratio And Complete Wiringfour Row Ledand Lcd Versionrs485 Complete Suitable 3 Phase 4 Four Wire System All As Specified And Directed. , Disconnecting And Taking Out Unserviceable Current Transformers Of 100/5 Amps Ct Ratio Of Any Description And Supply, Fixing, Connecting, Testing And Commissioning Of 100/5 Amps, Test Resin Cast Tap Wound Currenttransformer Of Rating100/5Amps On Lt Panel Board And Making Connections Of Secondaryterminals To Ammeter With Using 1.5 Sqmm Pvc Insulated And Sheathed Copper Conductor Cable ( Frls ) Complete All As Specified And Directed By Engineer-In-Charge. , Disconnecting And Taking Out Unserviceable Current Transformers Of 250/5 Ctratio Of Any Description And Supply, Fixing, Connecting, Testing And Commissioning Of 250/5 Amps, Test Resin Cast Tap Wound Currenttransformer Of Rating250/5 On Lt Panel Board And Making Connections Of Secondaryterminals To Ammeter With Using 1.5 Sqmm Pvc Insulated And Sheathed Copper Conductor Cable ( Frls ) Complete All As Specified And Directed By Engineer-In-Charge. , Disconnecting And Taking Out Unserviceable Current Transformers Of 400/5 Ampsratio Of Any Description And Supply, Fixing, Connecting, Testing And Commissioning Of400/5 Amps, Test Resin Cast Tap Wound Currenttransformer Of Rating400/5Amps On Lt Panel Board And Making Connections Of Secondaryterminals To Ammeter With Using 1.5 Sqmm Pvc Insulated And Sheathed Copper Conductor Cable ( Frls ) Complete All As Specified And Directed By Engineer-In-Charge. , Disconnecting And Taking Out Unserviceable Indication Lamps And Supply, Fixing, Connecting, Testing And Commissioning Of Indication Lamps Led Type With Showing Red, Yellow And Green Colours Of 22.5Mm Dia Fixed To Monitor On Lt Panel Board Suitable For 240 Volts Ac Supply And Making Connections With Using 1.5 Sqmm Pvc Insulated And Sheathed Copper Conductor Cable ( Frls ) Complete All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Replacement Selector Switches As Per The Existing Make And Model Including Necessary Connection And Commissioning In The Existing Panel Board/Feeder Pillar Box Including Testing Complete All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Replacement Aluminium Bus Bars Of Any Shape And Size Including Necessary Connection And Commissioning In The Existing Panel Board/Feeder Pillar Box Including Testing Complete All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Replacement Copper Bus Bars Of Any Shape And Size Including Necessary Connection And Commissioning In The Existing Panel Board/Feeder Pillar Box Including Testing Complete All As Specified And Directed By Engineer-In-Charge. , Supply And Fixing In Replacement Conical/ Single Bus Bar System Epoxy Insulator Including Nuts, Bolts And Washers Suitable For Lt 415 Volts, 50 Hz Ac Supply For Mounting Of Bus Bars In Lt Panels/Feeder Pillar Boxes Complete Including Necessary Connection And Commissioning Complete All As Specified And Directed By Engineer-In-Charge. , Supply, Fabrication & Fixing Of Doors Oflt Panel /Amf Panel/Ht Bus Bar Panel Both Front /Back Side Made Out Of Gi Sheet2.0 Mm To 3.15 Mm Thick Complete With Hinges Including Welding To Panel Body And Providing Locking System Amd Applying Two Coat Of Synthetic Enamel Paint By Spray Machine Over And Including A Coat Of Red Oxide Primer All As Specified And Directed By Engineer-In-Charge. , Supply And Laying In Repairs (Hdpe) Dwc Pipe Size 50 Mm Dia For Lt Cable Protection Including Sockets, Bends Etc Fixed To Wall/ Ceiling/ Under Floors Including Necessary Fittings Complete All As Specified And Directed By Engr-In-Charge. , Supply And Laying In Repairs (Hdpe) Dwc Pipe Size 90 Mm Dia For Lt Cable Protection Including Sockets, Bends Etc Fixed To Wall/ Ceiling/ Under Floors Including Necessary Fittings Complete All As Specified And Directed By Engr-In-Charge. , Supply And Fix In Replacement Control Mcb Sp 6 To 30 Amps , 240 Volts Complete All As Specified And Directed. , Supply And Fix In Replacement Rubber Gasket For Sealing Of Panel Doors Complete All As Directed. , Supply And Fix In Replacement Panel Lock And Rotating Key Suitable For Existing Panels Complete All As Specified And Directed. , Supply And Fix In Replacement Of Cable Glands Suitable For Of 25 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Cable Glands Suitable For Of 35 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Cable Glands Suitable For Of 50 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Cable Glands Suitable For Of 70 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Cable Glands Suitable For Of 90 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Cable Glands Suitable For Of 120 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Cable Glands Suitable For Of 150 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Cable Glands Suitable For Of 185 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Cable Glands Suitable For Of 240 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 25 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 35 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 50 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 70 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 90 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 120 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 150 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 185 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 240 Sqmm Size Of Cable Complete All As Specified And Directed. , Supply And Fix In Replacement Of Aluminium Lugs Suitable For Of 300 Sqmm Size Of Cable Complete All As Specified And Directed. , Repair, Maint And General Servicingof Existing Lt Panel Using Blower, Including Painting Of Panel With Two Coats Of Synthetic Enamel Paint Including Replacement Of Burnt Lugs And Insulation Of Bus Bars, Rewiring Of Lt Panel Including All Accessories, Cleaning Of Lt Panel, Welding Of Lt Panel To Its Angle Iron Frame, Other Pcc Related Work, Hinges Replacement, Locking Arrangement And All Other Small Maint Work Like Marking Of Lt Feeders With Synthetic Enamel Paints Complete All As Specified And Directed. , Supply And Fix In Replacement Danger Notice Plate Fixed To Lt Panel By Riveting Complete All As Specified And Directed. , S&F In Replacement Gi Tubing Light Grade 80 Mm Dia For Pole Cable Protection Including Fixingclamp, Nut Bolt Washer Complete Accssories Etc Complete All As Specified Anddirected. , M&L For Laying Only Existing Lt Cable Upto 50 Sqmm Size Laid Over The Ground /Into Trenches Including Disconnection And Making Connection Of The Same And Testing On Completion Complete All As Specified Anddirected. Note : Excavation, Returning Filling, Sand Cushioning / Protection Covers Will Be Measured Under Appropriate Items Of Schedulea. , M&L For Laying Only Existing Lt Cable 70 Sqmm To 120 Sqmm Size Laid Over The Ground /Into Trenches Including Disconnection And Making Connection Of The Same And Testing On Completion Complete All As Specified Anddirected. Note : Excavation, Returning Filling, Sand Cushioning / Protection Covers Will Be Measured Under Appropriate Items Of Schedulea. , Excavating In Trenches Soft /Loose Soil, N Exc 1.5 M Wide And N Exc 1.5 M In Depth; For Foundation, Etc. Or For Shafts, Wells, Cesspits, Manholes, Pier Holes, Etc. N Exc 10 Sq M On Plan And N Exc 1.5 M In Depth And Getting Out Complete All As Specified Anddirected. , Returning Filling In Including Spreading Leveling Watering And Well Ramming Inlayers Not Exceeding 25 Cm In Any Type Of Soil Complete All As Specified Anddirected. , Removing Excavated Materials To A Distance Not Exceeding 50 M And Depositing Where Directed, At A Level Not Exceeding 1.5 M Above The Starting Point In Any Type Ofsoils Complete All As Specified Anddirected. , Material & Labour For Sand Cushioning For Xlpe Cable With Tibba Sand Free From Foreign Material (One Layer Of 80 Mm Thickness Before Laying Of Cable And Other Layer Of 150 Mm Thickness After Laying Of Cable) & Punning Down To 180 Mm To Providea Required Cover Complete All As Specified And Directed By The Engineer-In-Charge. Note:- Punned Thickness Only Shall Be Measured And Paid. , Supply And Laying Unreinforced Precast Concrete Cable Cover, Class Lv, Type-I Flat Size 250Mm X 150Mm X 40Mm Complete All As Specified And Directed. , Supply, Laying, Jointing And Testing Ofxlpelt Cable Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminum Conductor Of 10 Sqmm 4 Core, 1100 Volts Grade Laid In Gi Pipe Complete All As Specified And Directed. , Supply, Laying, Jointing And Testing Ofxlpelt Cable Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminum Conductor Of 16 Sqmm 4 Core, 1100 Volts Grade Laid In Gi Pipe Complete All As Specified And Directed. , Supply, Laying, Jointing And Testing Ofxlpelt Cable Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminum Conductor Of 25 Sqmm 4 Core, 1100 Volts Grade Laid In Gi Pipe Complete All As Specified And Directed. , Supply, Laying, Jointing And Testing Ofxlpelt Cable Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminum Conductor Of 35 Sqmm 3.5 Core, 1100 Volts Grade Laid In Gi Pipe Complete All As Specified And Directed. , Supply, Laying, Jointing And Testing Ofxlpelt Cable Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminum Conductor Of 50 Sqmm 3.5 Core, 1100 Volts Grade Laid In Gi Pipe Complete All As Specified And Directed. , Supply, Laying, Jointing And Testing Ofxlpelt Cable Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminum Conductor Of 70 Sqmm 3.5 Core, 1100 Volts Grade Laid In Gi Pipe Complete All As Specified And Directed. , Supply, Laying, Jointing And Testing Ofxlpelt Cable Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminum Conductor Of 95 Sqmm 3.5 Core, 1100 Volts Grade Laid In Gi Pipe Complete All As Specified And Directed. , Supply, Laying, Jointing And Testing Ofxlpelt Cable Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminum Conductor Of 120 Sqmm 3.5 Core, 1100 Volts Grade Laid In Gi Pipe Complete All As Specified And Directed. , Supply, Laying, Jointing And Testing Ofxlpelt Cable Pvc Insulated, Armoured, Heavy Duty Electric Cable With Aluminum Conductor Of 185 Sqmm 3.5 Core, 1100 Volts Grade Laid In Gi Pipe Complete All As Specified And Directed. , Taking Down Of Lt Cableany Size From Trench /Gi Pipe/Walls / On Ground / Street Light Polescomplete All As Specified And Directed. , M&L For Boring Of Horizontal Holes Under Road Pavement, Hardstanding By Trenchless Technology Using Boring Machine Including Providing The Hdpe Protection Pipe Of 80 Mm Borecomplete All As Specified And Directed. , S&F In Repairs Mccb 400 Amp 4 Pole 415 V, 36Ka Thermal Megnatic Adjustable Type Complete All As Specified And Directed. , S&F In Repairsmccb 250 Amp 4 Pole 415 V,25 Ka Thermal Megnatic Adjustable Type Complete All As Specified And Directed. , S&F In Repairsmccb 200 Amp 4 Pole 415 V,25 Ka Thermal Megnatic Adjustable Type Complete All As Specified And Directed. , S&F In Repairsmccb 160 Amp 4 Pole 415 V,16 Ka Thermal Megnatic Adjustable Type Complete All As Specified And Directed. , S&F In Repairsmccb 125 Amp 4 Pole 415 V,16 Ka Thermal Megnatic Adjustable Type Complete All As Specified And Directed. , S&F In Repairsmccb 100 Amp 4 Pole 415 V,16 Ka Thermal Megnatic Adjustable Type Complete All As Specified And Directed. , S&F In Repairs Mccb 63 Amp 4 Pole 415 V,10 Ka Thermal Megnatic Adjustable Type Complete All As Specified And Directed. , Supply And Fix In Repair On Load Change Over Switch 415 V In Sheet Metal Enclosure 4 Pole Of Capacity 63 Amps Complete All As Specified And Directed. , Supply And Fix In Repair On Load Change Over Switch 415 V In Sheet Metal Enclosure 4 Pole Of Capacity 100 Amps Complete All As Specified And Directed. , Supply And Fix In Repair On Load Change Over Switch 415 V In Sheet Metal Enclosure 4 Pole Of Capacity 160 Amps Complete All As Specified And Directed. , Supply And Fix In Repair On Load Change Over Switch 415 V In Sheet Metal Enclosure 4 Pole Of Capacity 200 Amps Complete All As Specified And Directed. , Supply, Installation, Testing And Commisioning Of Cubical Type Outdoor Type Lt Panel With Ribbed Type External Surface, Made Of High Quality Crca Sheet Double Door Duly Powder Coated Rust Proof 3Mm Thick Including Ms Flat Iron Clamp/Angle Iron Of Size 40X40x6 Mm With Nut, Bolt Washer Etc Shall Be Provided If Required At Site Complete Including Necessary Pcc Foundation With Pcc(1:3:6)/Bricks Works And Necessary Earth Work Etc. As Directed By Eic. Panel Should Be Comparising Of Following:- 1) Incoming :-(A) Bus Bars Of Aluminiumstrips Of 400 Amp Current Rating Capacity Mounted On Epoxy/Frp Bus Bar Insulator - 01 Set (B) Mccb, 250 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 35/36 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%- 01 No. (C)Multifunction Meter With Lcd Display Accuracy Class 0.5To Measure Voltage, Current, Power With Suitable Size Ct (D) Indicating Lamp Set Of 03 R,Y,B 2) Outgoing:- (A) Mccb,160 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 25 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%- 01 (B)Mccb,125 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 16 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%-02 (C) Mccb, 63 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 16 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%-02 Note:- (I) All Outgoing Feeder Shall Be Connected With Suitable Size Of Bus Bar. (Ii) Botom Of The Panel Shall Be 600 Mm Above From Ground Level. (3) Internal Wiring For Indicating Lamp And Multifunction Meter Should Be With 1.5 Sqmm Frlsh Copper Wire, All Outgoing Feeder Shall Be Connected With Suitable Size Of Bus Bar And Marking Of Incomer And Outgoing Feeder With Synthetic Enamel Paint . , S&F Lt Feeder Pillar ( Kiosk ) Of Suitable Made Out 3Mm Thick Crca Sheet Duly Powder Coated Rust Proof Paint Out Door Type Double Door With Openable Front Doorincluding Locking Arrangement Withcopper Busbar250 Amps Rating With Mccb 125 Amps4pole 16Ka Thermal Megnatic Adustable Type For Incoming And Fixedonangle Iron Frame And Pcc Plinth Complete All As Specified And Directed. , S&F Lt Feeder Pillar ( Kiosk ) Of Suitable Made Out 3Mm Thick Crca Sheet Duly Powder Coated Rust Proof Paint Out Door Type Double Door With Openable Front Doorincluding Locking Arrangement Withcopper Busbar400 Amps Rating With Mccb 250 Amps 4Pole 25Ka Thermal Megnatic Adustable Type For Incoming And Fixedonangle Iron Frame And Pcc Plinth Complete All As Specified And Directed. , Supply, Installation, Testing And Commisioning Of Cubical Type Indoor Lt Panel With Ribbed Type External Surface, Made Of High Quality Crca 2 Mm Thick Duly Powder Coated Dust Proof Paintms Flat Iron Clamp/Angle Iron Of Size 40X40x6 Mm With Nut, Bolt Washer Etc Shall Be Provided If Required At Site Complete Including Necessary Pcc Foundation With Pcc (1:3:6)/ Brick Work And Necessary Earth Work As Required As Site For Panel Foundation Etc. And 04 Lifting Hook Should Be Provided At Top Of Panel Complete All As Directed By Eic. Panel Should Be Comparising Of Following:- 1) Incoming:- (A) Bus Bars Of Aluminiumstrips Of 400 Amp Current Rating Capacity Mounted On Epoxy/Frp Bus Bar Insulator - 01 Set (B) Mccb, 250 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 35/36 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%- 01 Nos. (C)Multifunction Meter With Lcd Display Accuracy Class 0.5To Measure Voltage, Current, Power With Suitable Size Ct (D) Indicating Lamp Set Of 03 R,Y,B 2) Outgoing:- (A) Mccb,160 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 25 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%-02 Nos (B)Mccb,125 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 16 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%-02 Nos (C)Mccb, 63 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 16 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%-01 Nos Note:- (I) All Outgoing Feeder Shall Be Connected With Suitable Size Of Bus Bar. (Ii) Botom Of The Panel Shall Be 600 Mm Above From Ground Level. (Iii) Internal Wiring For Indicating Lamp And Multifunction Meter Should Be With 1.5 Sqmm Frlsh Copper Wire All Outgoing Feeder Shall Be Connected With Suitable Size Of Bus Bar And Marking Of Incomer And Outgoing Feeder With Synthetic Enamel Paint. , Supply, Installation, Testing And Commisioning Of Cubical Type Outdoor Lt Panel With Ribbed Type External Surface, Made Of High Quality Crca 2 Mm Thick Duly Powder Coated Dust Proof Paintms Flat Iron Clamp/Angle Iron Of Size 40X40x6 Mm With Nut, Bolt Washer Etc Shall Be Provided If Required At Site Complete Including Necessary Pcc Foundation With Pcc (1:3:6)/ Brick Work And Necessary Earth Work As Required As Site For Panel Foundation Etc. And 04 Lifting Hook Should Be Provided At Top Of Panel Complete All As Directed By Eic. Panel Should Be Comparising Of Following:- 1) Incoming :- (A) Bus Bars Of Aluminium Strips Of 400 Amp Current Rating Capacity Mounted On Epoxy/Frp Bus Bar Insulator - 01 Set (B) Mccb, 200 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 35/36 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%- 01 Nos. (C)Multifunction Meter With Lcd Display Accuracy Class 0.5To Measure Voltage, Current, Power With Suitable Size Ct (D) Indicating Lamp Set Of 03 R,Y,B 2) Outgoing :- (A) Mccb, 160 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 25 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100% -01 Nos (B)Mccb, 125 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 16 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%-01 Nos (C) Mccb, 63 Amps, 4 Pole, 415 Volts, Ac Supply,Having Breaking Capacity 16 Ka (Ics=Icu=100%) With Adjustable Load Setting From 80% To 100%-02 Nos Note:- (I) All Outgoing Feeder Shall Be Connected With Suitable Size Of Bus Bar. (Ii) Botom Of The Panel Shall Be 600 Mm Above From Ground Level. (Iii) Internal Wiring For Indicating Lamp And Multifunction Meter Should Be With 1.5 Sqmm Frlsh Copper Wire All Outgoing Feeder Shall Be Connected With Suitable Size Of Bus Baar And Marrking Of Incomer And Outgoing Feeder With Synthetic Enamel Paint. , Taking Out Old Lt Panel And Bus Bar Panels Complete All As Specified And Directed. , M&Lin Repair For Earthing Complete With Gi Earth Plate Electrode 60Cmx60cmx6mm Thick, Buried Directly In Ground (Earth Pit Not Less Than 2.25 Metres Deep Below Ground Level) With Top Edge Of The Plate Not Less Than 1.5M Below Normal Ground Level, Connected To And Including Gi Earthstrip 32X6 Mm By Means Of Bolts, Nuts, Check Nuts And Washers Of Galvanized Iron Or Steel All As Shown In Electrical Plate No 3 Of Ssr Part-I Connected To Earthing Test Point All As Specified Or Indicated Including Testing On Completion And Excavation And Earth Work In Any Type Of Soil, Pcc 1:3:6 Typec1in Chamber, Precastrcc Cover 50Mm Thick In Cement Concrete 1:2:4 Type B1, Reinforced With Welded Steel Wire Fabric Or Xpm (Weight Not Less Than 4 Kg/Sqm) With Cast Iron Frame, Funnel With Wire Mesh, 20Mm Bore Gi Pipe Medium Grade Watering Pipe, Lugs, 40Mm Bore Gi Pipe Medium Grade Protection Pipe Upto 7.5M As Directed. , S&F In Replacement Ofcable Jointing Kit For 1100V Grade Cable For Straight Through Heat Shrinktype Joint Complete Jointing Material & Accessories Suitable For 3.5 Core Xlpe Armoured Aluminium Condctor Of Size 95 To 120 Sqmm Complete All As Specified And Directed. , S&F In Repairs Ofcable Jointing Kit For 1100V Grade Cable For Straight Through Heat Shrinktype Joint Complete Jointing Material & Accessories Suitable For 3.5 Core Xlpe Armoured Aluminium Condctor Of Size 150To 185Sqmm Complete All As Specified And Directed. , S&F In Repairsofcable Jointing Kit For 1100V Grade Cable For Straight Through Heat Shrinktype Joint Complete Jointing Material & Accessories Suitable For 3.5 Core Xlpe Armoured Aluminium Condctor Of Size 50 To 70 Sqmm Complete All As Specified And Directed. , S&F In Repairs Ofcable Jointing Kit For 1100V Grade Cable For Straight Through Heat Shrinktype Joint Complete Jointing Material & Accessories Suitable For 3.5 Core Xlpe Armoured Aluminium Condctor Of Size 240 To 300 Sqmm Complete All As Specified And Directed. , Supply, Installation, Testing And Commissiong Of Three Phase Submersible Pump Of Capacity 7.5 Hp, Discharge Head 15 M To 50 M,End/Side Suction Centrifugal Pump,Flanged Inlet And Outlet With Counter Flange With Bolt And Nut, Complete Set With Star-Delta Starter Control Panel, Motor Power Cable - 40 Meter, Including Water Level Controlleter Electrode Sensor And Level Control Cable Including Complete Wiring For Installation For Pumping Ground Water From Deep Wells Including Dismantaling Of Existing Unserviceble Pump Set Of Any Description Complete All As Specified And Directed. Notes : (I)Rate For Gi Pipe / Reducer/ Any Addition Items Required For Making Connection With Existing Pipe Line And Open Well And Submersible Pump Shall Be Deemed To Be Included In The Above Quoted Rate.(Ii) Existing Pump Shall Be Deposited To Mes Store Yard.

Corrigendum Details

Sr No CorrigendumDate Corrigendum CorrigendumType NewSubmissionDate
1 05-12-2024 Revision of BOQ BOQ 18-12-2024
2 18-12-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 25-12-2024

Key Value

Document Fees
INR 500 /-
EMD
INR 80000.0 /-
Tender Value
INR 40 Lakhs /-
Disclaimer :