| 1 | Annexure-I:Provision of Power supply for Elevator at Ponnani Lighthouse |
| 2 | MODULAR SWITCH BOXES, SWITCHES AND SOCKETS |
| 3 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 1 or 2 Module (75mm * 75mm) |
| 4 | Supplying and fixing following size/ modules, GI box along with modular base & cover plate for modular switches in recess etc. as required. 4 Module (125mm * 75mm) |
| 5 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 5/6A One way switch |
| 6 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 2 way 5/6A switch |
| 7 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 6 pin 15/16A socket outlet |
| 8 | Supplying and fixing 3pin, 5A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 9 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq.mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 10 | CONDUIT AND CABLE |
| 11 | Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. 20/25mm |
| 12 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 1.5 sq. mm (Bulk Head wiring) |
| 13 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 3 x 4 sq. mm (Power Socket at DG set shelter) |
| 14 | Supplying and drawing following pair 0.5 mm dia FRLS PVC insulated annealed copper conductor, unarmored telephone cable in the existing surface/ recessed steel/ PVC conduit as required. 2Pair |
| 15 | Supply, laying of CAT-6, 4 pair UTP cable with LSZH sheath and minimum 23 AWG copper conductor through the existing conduit as required. |
| 16 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray (galvanisation thickness not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling/surface with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 17 | Supplying and installing following size of perforated Hot Dipped Galvanised Iron cable tray “bends” (galvanisation not less than 50 microns) with perforation not more than 17.5%, in convenient sections, joined with connectors, suspended from the ceiling with G.I. suspenders including G.I. bolts & nuts, etc. as required. 150 mm width X 50 mm depth X 1.6 mm thickness |
| 18 | SWITCH GEAR & DB |
| 19 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 6-way, Double door |
| 20 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and and commissioning etc. as required. 63A |
| 21 | Supplying and fixing following rating, Four pole, (three phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 63A |
| 22 | Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40A |
| 23 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole 6A - 02Nos.,16A - 06Nos. |
| 24 | UG CABLE LAYING |
| 25 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. Up to 35 sq.mm |
| 26 | Laying of one number additional PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of following size direct in ground in the same trench in one tier horizontal formation including excavation, sand cushioning, protective covering and refilling the trench etc., as required Up to 35 sq.mm |
| 27 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1KV grade of following size on the wall surface as required. Up to 35 sq.mm |
| 28 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. (For all UG cables) |
| 29 | EARTHING |
| 30 | Earthing with copper earth plate 600 mm X 600 mm X 3 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required |
| 31 | Supplying and laying 25 mm X 5 mm copper strip at 0.50 metre below ground as strip earth electrode, including connection/ terminating with nut, bolt, spring, washer etc. as required. (Jointing shall be done by overlapping and with 2 sets of brass nut bolt & spring washer spaced at 50mm) |
| 32 | Providing and fixing 25 mm X 5 mm copper strip in 40 mm dia G.I. pipe from earth electrode including connection with brass nut, bolt, spring, washer excavation and re-filling etc. as required. |
| 33 | Providing and fixing 25 mm X 5 mm copper strip on surface or in recess for connections etc. as required. |
| 34 | Earthing with G.I. earth pipe 4.5m long, 40mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. (For meter box) |
| 35 | Providing and laying earth connection from earth electrode with 4.00mm (8SWG) dia copper wire in 15mm dia G.I. pipe from earth electrode including connection with copper thimble excavation and re-filling as required. (For meter box) |
| 36 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required. 32 A one-way double pole switch with indicator - 2 module |
| 37 | Supplying and fixing following rating, double pole, 415 volts, miniature circuit breaker (MCB),10 kA as per IS/IEC 60898-1 2002, in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand DX³ MCBs 4087 37 or equivalent reputed make and model as required. 40A |
| 38 | Supplying and fixing following rating, four pole, 415 volts, miniature circuit breaker (MCB),10 kA as per IS/IEC 60898-1 2002, in the existing MCB DB complete with connections, testing and commissioning etc. as required. Legrand DX³ MCBs 4087 02 or equivalent reputed make and model as required. 63A |
| 39 | Supply and installation of TPN DB 4 way (8+12) IP 43 - #IK 09 with metal door, Conforming to IEC 61439-3, Suitable for Flush Mounting and Surface Mounting, with 100 A Copper Bus bar for each phase, with Neutral bar, Earth bar and Cable ties for Cable management, Fully insulated bus bar & shrouded Neutral bars, Improved Pan assembly for ease of installation, Pre-fitted masking sheet, Reversible Door, with provision for FP MCB/Isolator/RCCB/RCBO as incomer and SP/TP MCB\"s as outgoing and Supplied with wire set, Legrand Ekinox³ 5077 25 or equivalent reputed make and model as required. including 63A, 30mA, 4P, RCBO Legrand Ekinox³ 4113 74 or equivalent reputed make and model as required. |
| 40 | Providing and fixing following capacity TP&N disconnector fuse switch unit with sheet steel enclosure with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required, 100A |
| 41 | Providing and fixing following capacity TP&N Onload Changeover switch unit with sheet steel enclosure with ISI marked including drilling holes in cubicle panel, making connections, etc. as required, 100A |
| 42 | Supply and installation 63A, 4P,25kA, MCCB, Legrand Ekinox³ DB\"s 4200 53 with Ics=100%Icu, Four Optimum Frames, Thermal Adjustable – 0.8 to 1In, Magnetic Adjustable** – 5 to 10In, Breaking Capacity# – 25kA, Option for In built or add on module for Earth Leakage Protection, Adjustable sensitivity: 0.03 - 0.3 - 1 - 3 A, Adjustable tripping: 0 - 0.3 - 1 - 3s, Suitable for Isolation, Fixed at 10In for DPX³ 160 or equivalent L&T/Havells/reputed make, with Metal one way enclosures for MCCB, Legrand Ekinox³ 5078 01 or equivalent L&T/Havells/reputed make |
| 43 | Supply and fixing of Sintex JB (GSJB. 1510) with Krone connector for incoming Telephone Supply. |
| 44 | Providing and fixing following capacity Rotary Phase Changeover unit with sheet steel enclosure with ISI marked including drilling holes in cubicle panel, making connections, etc. as required, L & T, 72347P M17TDYR make or equivalent, 63A |
| 45 | Providing and fixing following capacity TP&N Off-load Switch disconnector unit with sheet steel enclosure with ISI marked including drilling holes in cubicle panel, making connections, etc. as required, Havells, IHCSTE0100 make or equivalent, 100A |
| 46 | 2MP IR Bullet IP Camera:-1/2.8\" CMOS, F2.0, Fixed Iris, Digital WDR, 30m IR, 0.02Lux, 1920x1080@30fps, Built-in Mic, IP67, PoE, Metal+ Plastic housingWarranty: - As per the OEM or 3 years whichever is more. Make: Dahua/CP Plus or equivalent |
| 47 | Bulk Head Luminaries IP65/66/67 IK09/10 with integrated LED source, Philips WT202 10W IP66, Havells Hexa 10W IP66/Luker LWSQB10 IP65 make or Equivalent model of Reputed make as required |
| 48 | Supply of UG Cable, 4Core x 16 sq.mm, Armoured, All Copper Conductor - Solid / Stranded Non-Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (from DG set to LTDB & LTDB to Machine room Supply) |
| 49 | Supply of UG Cable, 2Core x 4 sq.mm, Armoured, All Copper Conductor - Solid / Stranded Non-Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (from Power house DB to Tower bottom DB and to machine room for single phase load of Elevator) |
| 50 | Supply of Un-armoured Cable, 3Core x 4 sq.mm, All Copper Conductor - Solid / Stranded Non-Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (from Tower Base DB to Power sockets) |
| 51 | Supply of Un-armoured Cable, 3Core x 2.5 sq.mm, All Copper Conductor - Solid / Stranded Non-Compacted Circular, HR PVC/ XLPE Insulation, conforming to standards: as per IS 1554 Part-1&2 & IS 7098 Part-1&2, reputed make as required. (from Tower Base DB to Elevator well lighting and machine room lighting) |
| 52 | Miscellaneous items for the purchase of screws, Bolts, Nuts & Washers, drill bits, cable ties, bends, tees, wire strippers, steel spring, cable glands, pvc junctions boxes etc., |
| 53 | Annexure-II:Provision of DG set and Servo Stabilizer for Elevator at Ponnani Lighthouse |
| 54 | Silent DG Set, Liquid Cooled, 30 kVA ,1500 rpm, electrical start, 12 V battery coupled with Three phase, 415 V Alternator and AMF Control Panel inside canopy complete with all accessories, 2Nos. of Copper Plate Earthing for Neutral and 2Nos. of Copper Plate Earthing for Body, Supply, installation and commissioning etc inclusive of all TaxesEngine:- Kirloskar/Cummins/Toshiba makeAlternator:- Kirloskar/Stamford/mecc alte/ Leroy-Somer make |
| 55 | Supply, installation and commissioning of 30KVA 3Phase servo Stabilizer with following specifications1)Standard: - Confirming is 98152)Ratings: - 30kVA Three Phase3)Type: - Indoor floor mounting4)Input Line Voltage: - 310-460 V AVC5)Output Line Voltage: - 415(+/-)2%6)Load Type: -Unbalanced Type7)Phase: - 3PH, 4 WIRES8)Wave Form Distortion: - Less than 1%9)Input Frequency: - 48-52 Hertz10)Output Frequency: -50HZ11)Method of Cooling: -Air Cooled12)Operation Mode: -Automatic & Manual13)Suitability: -Suitable for 3-Phase, 4 Wires, Unbalanced Voltage, Unbalanced Load & Balanced Load14)Monitoring Facility: -Input Voltage, Output Voltage15)Indicator: -Input Voltage, Output Voltage and High Low Cut-off16)Protection: -Over Voltage/Under Voltage/Over Load/Single Phase Prevention17) One set spare PCB’sMake:- Automatic Electric Ltd./Supra Hitech /Servomax |