The remaining work of Vikas Path Ajari in package number RJ-30-01/5054/NP/2019-20 of district Sirohi (Risk&Cost) - Part 1 Vikas Path Ajari Construction of Vikas Path at Ajari Village to Ajari Gram Panchayat Markundeshwar Dham road RJ-30-01/Vikas Path/2019-20 Earth work in excavation, including stacking/disposal of surplus material with all lifts and lead upto 495 metres, exclusive of compensation of earth [MoRTH specification : Clause 301 to 305] When excavation and loading is done mechanically using Bull Dozar, F.E.Loader and carriage is done by tipper/dumper (6T capacity)., Cement Concrete for plain/reinforced concrete in open foundation, any level, complete as per drawing and technical specifications. [MoRTH Specification Section 1700&1500] .P.C.C.M15 grade, Providing and laying granular sub-base material having P.I.not more than 6, including spreading in layers not exceeding 150 mm compacted thickness and consolidation by 8-10 tonne power roller to required camber and grade including cost of water and hire charges of machinery, including T&P with all lead (Compacted thickness to be measured).as per MORTH specification table 400-1, 400-2 :For grading-III with CBR value not less than 20.to attain 100% proctor density., Providing, laying, spreading and compacting stone aggregate of specfic as per table 400-7 to Water Bound Macadam specification including spreading in uniform thickness, hand packing roll-ing with vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening and binding materials to fill-up the interstices of coarse aggregates watering (with water browser) and rolling making necessary earthen bund to protect edegs, lighting, guarding, barricading and maintenance of diversion etc. [MoRTH specfication : Clause 404] ( By manual means).Grading II , 63 mm to 45 mm @ 0.91 cum per 10 Sqm for compacted thickness of 75 mm. (Crusher broken)Stone screening type B, Providing, laying, spreading and compacting stone aggregate of specfic as per table 400-7 to Water Bound Macadam specification including spreading in uniform thickness, hand packing roll-ing with vibratory roller in stages to proper grade and camber, applying and brooming requisite type of screening and binding materials to fill-up the interstices of coarse aggregates watering (with water browser) and rolling making necessary earthen bund to protect edegs, lighting, guarding, barricading and maintenance of diversion etc. [MoRTH specfication : Clause 404] ( By manual means).Grading III, 53 mm to 22.4 mm, @ 0.91 cum per 10 Sqm for compacted thickness of 75 mm. (Crusher broken)Stone screening type B, Provinding and laying of paver block as per IS 15658 : 2006 (Indian standerd for Precast concrete block for Paving - specification) and IRC :SP:63-2004(guidelines for the use of interlocking concrete blockPavement) M-40,80mm thick to be used in medium-traffic (Medium trafficis defind as a daily traffic of 150-450 commercial vehicles exceeding 30 KN laden weight , or an equivalent of 0.5 to 2.0 MSA for a design life of 20years) like city streets, small and medium market roads, low volume roads ,ytility cuts on arterial roads, etc.Categary A Denated units to key into each other on four faces zigag shape as per IRC SP 63:2004, Cement Concrete for plain/reinforced concrete in open foundation, any level, complete as per drawing and technical specifications. [MORTH Specification Section 1700&1500) Concrete in P.C.C.M20 grade Providing and laying reinforced cement concrete pipes N.P.4 for culverts including jointing ends and fixing collar with cement mortar 1:2 [MORTH Specfication: Clause 1000/29001300 mm dia. Supply & fixing of Direction and place identification sign board made out of 2 mm thick M.S. sheet framed to angle iron 40x40x5 mm and two vertical posts of angle iron of size 65x65x6 mm 3 meter long with hold fasts, stove enameled paint reflective letter symbol complete of size: 150 x 120 cm. Providing and fixing of retro reflectorised indusive cautionary, mandatory and informatory sign as per IRC-67 made of high intensity grade sheeting lettering, border & signs fixed over aluminium sheeting, 1.5 mm thick, fixed on mild steel angle iron frame 50mmx50mmx6mm supported on a mild steel angle iron post 75mmx75mmx6mm upto the top of sign board, length of post from bottom of sign board is 2.85m. upto foundation level post duly painted in black & white synthetic enamel. fixed to the ground by means of properly designed foundation with M-15 grade cement concrete 45 Cm x 45 Cm x 60cm, 60 cm below ground level as per approved drawing & as per MORTH specification CL 801 90 Cm equilateral triangle Providing and fixing of Reinforced Ferro cement Drain cover designed for class AA loading duly marked on cover with adequate steel reinforcement having thickness 75 mm to 150 mm anti-corrosive bitumen painted M.S. plate Rim and on M.S. lifting hooks admixture like plasticizer bond improving compound shrinkage resistance compound abrasion resistant complete as per approved design etc. for drain Opeining Size 300 to 450 mm Standard Drain Cover Size 600mm x 800mm 75mm