Sales : +91-777 804 8217
| Sl. No. | Item Description |
| 1 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 metres lead. |
| 2 | Demolishing lime concrete manually/ by mechanical means and disposal of material within 50 metres lead as per direction of Engineer- in-charge. |
| 3 | Dismantling tile work in floors and roofs laid in cement mortar including stacking material within 50 metres lead. For thickness of tiles above 25 mm and up to 40 mm |
| 4 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, holdfasts etc. complete and stacking within 50 metres lead : |
| 5 | Removing white or colour wash by scrapping and sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete |
| 6 | Disposal of moorum/building rubbish/ malba/ similar unserviceable, dismantled or waste material by mechanical transport including loading, transporting, unloading to approved municipal dumping ground for lead upto 10 km for all lifts, complete as per directions of Engineer-in-charge. |
| 7 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. |
| 8 | Excavating, supplying and filling of local earth (including royalty) by mechanical transport upto a lead of 5km also including ramming and watering of the earth in layers not exceeding 20 cm in trenches, plinth, sides of foundation etc. complete. |
| 9 | Sand filling in plinth including supply of necessary quantity of local sand from a distance not exceeding 8 Kms from the site of work and including watering dressing etc. required for proper completion of work |
| 10 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:4:8 (1 Cement : 4 coarse sand (zone-III) derived from natural sources : 8 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 11 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1%:3 (1 Cement: 1% coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 12 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level :. 1:1.5:3 (1 cement : 1.5 coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources)R.C.C. work in Footing |
| 13 | R.C.C. work in Column |
| 14 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : 1:1.5:3 (1 cement : 1.5 coarse sand : 3 graded stone aggregate 20 mm nominal size)R.C.C.work in Beams |
| 15 | R.C.C.work in Column |
| 16 | Brick work with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundation and plinth in: Cement mortar 1:4 (1 cement : 4 coarse sand) |
| 17 | Class-150 (Non Modular) brick work in 1:6 cement and Coarse sandmortar in super-structure above plinth level upto floor five level including necessary cutting, mouldingof brick work as required and supply of all materials, labour and T&P etc. required for proper completion of the work. (230mm wall) |
| 18 | Brick work with common burnt clay F.P.S. (non modular) bricks of class-150 in foundation and plinth in: Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 19 | Class-150 (Non Modular) brick work in 1:4 cement and Coarse sandmortar in super-structure above plinth level upto floor five level including necessary cutting, mouldingof brick work as required and supply of all materials, labour and T&P etc. required for proper completion of the work. (115mm wall) |
| 20 | Providing and laying damp-proof course 40 mm thick with cement concrete 1:2:4 (1 cement : 2 coarse sand (zone-III): 4 graded stone aggregate 12.5mm nominal size) |
| 21 | Painting on Footing in foundationwith two coat of air blown bitumen 85/50 or 85/25 @ 1.7kg per sqm. Approximate including cost of fuel if any |
| 22 | Providing & applying a coat of residual petroleum bitumen of grade of VG-10 of approved quality using 1.7kg per square metre on damp proof course after cleaning the surface with brushes and finally with a piece of cloth lightly soaked in kerosene oil. |
| 23 | TMT Fe-500 or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work and including supply of steel its wastage bend hooks and authorised over lapping shall be measured upto floor two level. |
| 24 | Centering and shuttering including strutting, propping etc. and removal of form for: Foundations, footings, bases of columns, etc. for mass concrete |
| 25 | Centering and shuttering including strutting, propping etc. and removal of form for Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 26 | Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 27 | Suspended floors, roofs, landings, balconies and access platform. with water proof ply 12 mm thick. |
| 28 | Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mmthick |
| 29 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 30 | Mild steel or iron workofsmall sizes and sections suchas hold fast etc. ( when notincludedinan overall rates) wroughttorequiredfromincluding supply ofsteel anditswastage includingcostof bolts, nuts if required forandwelding, grinding and making holes as required completion of workfabricationofholesdoors, chaukhats nosing. |
| 31 | Z-Section steel windows (openable)/Angle iron door chaukhats 40*40*5 |
| 32 | Mild steel or iron work of small sizes and sections such as holding down bolts, hold fast tierods,gratings etc. ( when not included in an over all rates) wrought to required from including supply of steel and its wastage including cost of bolts, nuts if required for and welding, grinding and making holes as required completion of work fabrication of holes doors, chaukhats nosing. |
| 33 | Fixing of Door, windows/ventilators chaukhats in position.(a) Door chaukhats |
| 34 | (b) Window chaukhats |
| 35 | (c) Ventilator chaukhats |
| 36 | Providing and fixing factory made P.V.C. door frame of size 50x47 mm with awall thickness of 5 mm, made out of extruded 5mm rigid PVC foam sheet, mitred at corners and joined with 2 Nos of 150 mm long brackets of 15x15 mm M.S. square tube, the vertical door frame profiles to be reinforced with 19x19 mm M.S. square tube of 19 gauge, EPDM rubber gasket weather seal to be provided through out the frame. The door frame to be fixed to the wall using M.S. screws of 65/100 mm size, complete as per manufacturer’s specification and direction of Engineer- in-Charge. |
| 37 | Providing and fixing factory made 18 mm thick single extruded WPC (Wood PolymerComposite) solid plain white colour board Jali, CNC (Computer numeric control) routed of approved design by Engineer-in -charge which are machine cut for duct/shaft covering, partitions and facades comprising of virgin polymer of K value 58-60 (Suspension Grade), calcium corbonate and natural fibers (wood powder/ rice husk/wheat husk) and non toxic additives(maximum toxicity index of 12 for 100 gms) having minimum densityof 650 kg/cum and screw withdrawal strength of 1800 N (Face) minimum compressive strength 50 N/mm2, modulus of elasticity 850 N/mm2 and resistance to spread of flame of Class A category with properties of being termite/borer proof, water/moisture proof and fire retardant and fixing on M.S (mild steel) frame made of 25 x 25 x 1.5 mmsquare hollow box section including applying a priming coat of approved steel primer,placed at grid made at 1.0 x 1.0 m or as per requirement at site with necessary stainlesssteel fasteners and SS screws etc., all complete as per direction of Engineer-In- Charge.(Note: M.S (mild steel) framework with priming coat and necessary SS fasteners and SSscrews shall be paid separately. |
| 38 | Providing and fixing factory made panel PVC door shutter consisting of frame made out of M.S. tubes of 19 gauge thickness and size of 19 mm x 19 mm for styles and 15x15 mm for top & bottom rails. M.S. frame shall have a coat of steel primers of approved make and manufacture. M.S. frame covered with 5 mm thick heat moulded PVC \"C\" channel of size 30 mm thickness, 70 mm width out of which 50 mm shall be flat and 20 mm shall be tapered in 45 degree angle on both side forming styles and 5 mm thick, 95 mm wide PVC sheet out of which 75mm shall be flat and 20 mm shall be tapered in 45 degree on the inner side to form top and bottom rail and 115 mmwide PVC sheet out of which 75 mm shall be flat and 20 mm shall be tapered on both sides to form lock rail. Top, bottom and lock rails shall be provided both side of the panel. 10 mm (5 mm x 2 ) thick, 20 mm wide cross PVC sheet be provided as gap insert for top rail & bottom rail, paneling of 5 mm thick both side PVC sheet to be fitted in the M.S. frame welded/ sealed to the styles & rails with 7 mm (5 mm+2 mm) thick x 15 mm wide PVC sheet beading on inner side, and joined together with solvent cement adhesive. An additional 5 mm thick PVC strip of 20 mm width is to be stuck on the interior side of the \"C\" Channel using PVC solvent adhesive etc. complete as per direction of Engineer-in-charge, manufacturer\"s specification & drawing.30 mm thick pre laminated PVC door shutters |
| 39 | Mild steel or iron workofsmall sizes and sections suchas Z-Section etc. ( when notincludedinan overall rates) wroughttorequiredfromincluding supply ofsteel anditswastage includingcostof bolts, nuts if required forandwelding, grinding and making holes as required completion of workfabricationofholesdoors, chaukhats nosing. |
| 40 | Mild steel or iron workofsmall sizes and sections suchas Grill etc. ( when notincludedinan overall rates) wroughttorequiredfromincluding supply ofsteel anditswastage includingcostof bolts, nuts if required forandwelding, grinding and making holes as required completion of workfabricationofholesdoors, chaukhats nosing. |
| 41 | Providing and fixing concertina coil fencing with punched tape concertina coil 600 mm dia 10 metre openable length ( total length 90 m), having 50 nos rounds per 6 metre length, upto 3 m height of wall with existing angle iron ‘Y’ shaped placed 2.4 m or 3.00 m apart and with 9 horizontal R.B.T. reinforced barbed wire, stud tied with G.I. staples and G.I. clips to retain horizontal, including necessary bolts or G.I. barbed wire tied to angle iron, all complete as per direction of Engineer-in-charge, with reinforced barbed tape(R.B.T.) / Spring core (2.5mm thick) wire of high tensile strength of 165 kg/ sq.mm with tape (0.52 mm thick) and weight 43.478 gm/ metre (cost of M.S. angle, C.C. blocks shall be paid separately) |
| 42 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per 100 m (minimum), between the two posts fitted and fixed with G.I. staples, turn buckles etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used. With G.I. barbed wire |
| 43 | Making drain along with the apron 150x150mm |
| 44 | Providing & fixing at all heights, levels and locations Mill finish Aluminium alloy roofing sheets of alloy IS designation 31500, temper Hx8 conforming to IS 737 and dimensions as per IS code 2676 with characteristics of good formability and corrosion resistance. The profile sheets shall be fixed to truss members in slope or required pitch or curvature with Hex cap headed self drilling/tapping Stainless steel screws M6, 50 mm long with 3 mm EPDM seal washer etc. all inclusive of labour, scaffolding, T&P and sundries etc. complete as per directions of the Engineer-In-Charge. (Cost of truss/frame work shall be paid separately). 0.91 mm Aluminium profile with center to center pitch of 175 mm, depth of 46 mm, top crest width of 41 mm, bottom valley width of 80 mm, overall profile width of 1144 mm, cover width 1050 mm. |
| 45 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished seamless type tubes (MAKE TATA JINDAL REQ.) |
| 46 | 15 mm plinth plaster (1 cement :4 coarse sand) F.M.-2.25 |
| 47 | 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. F.M. 2.25 |
| 48 | 12 mm cement plaster in single coat on fair side of single or half brick wall for interior plastering up to floor two level including internal rounded angles not exceeding 80 mm in girth and finshed even and smooth. (1) 1 cement : 6 coarse sand. F.M. 2.25 |
| 49 | Making drip coarse sand in sun shades or facia with 1:3 cement and fine sand mortar as per direction of Engineer-in charge including supply of all materials, labour, Tools & plants etc. required for proper completion of the work. |
| 50 | Distempering(Two coat) withoil bound distemper of approvedbrand and manufacture&ofrequired shadeon undecorated wall surface to give an even shade over &includingapriming coat with cement primer of approvedbrand& manufacture such as Berger,J&N, Shalimar Asian paintsafterthoroughly brushing the surface free from mortar droppings & other foreign matters& alsoincluding preparing the surfaceeven with plaster of paris orapproved synthetic material &sand papered smooth including cost of all materials.[Inside walls] |
| 51 | Finishing walls with Premium Acrylic Smooth exterior paint with Silicone additives of required shade : New work (Two or more coats applied @ 1.43 ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm). |
| 52 | Providing and applying white cement based putty of average thickness 1mm approved brand and manufacture over the plastic wall surface to prepare the surface even and smost complete. |
| 53 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS: 733 and IS: 1285, fixing with dash fasteners of required dia and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc. Aluminium sections shall be smooth, rust free, straight, mitred and jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing / paneling, C.P. brass / stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, panelingand dash fasteners to be paid for separately) Polyester powder coated aluminium (minimum thickness of polyester powder coating 50 micron) |
| 54 | Providing and fixing anodised aluminium grill (anodised transparent or dyed to required shade according to IS: 1868 with minimum anodic coating of grade AC 15) of approved design/pattern, with approved standard section and fixed to the existing window frame with C.P. brass/ stainless steel screws @ 200 mm centre to centre, including cutting the grill to proper opening size for fixing and operation of handles and fixing approved anodised aluminium standard section around the opening, all complete as per requirement and direction of Engineer-in-charge. (Only weight of grill to be measured for payment). |
| 55 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) decorativetype, core of block board construction with frame of 1st class hard wood and well matchedteak 3 ply veneering with vertical grains or cross bands and face veneers on both faces ofshutters. 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws |
| 56 | Extra for cutting rebate in flush door shutters (Total area of the shutter to be measured). |
| 57 | Providing and fixing ISI marked flush door shutters conforming to IS :2202 (Part I) non-decorative type, core of block board construction withframe of 1st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters : 35 mm thick including ISI marked Stainless Steel butt hinges with necessary screws (a) 35mm thick including ISI marked stainless steel butt hinges with necessary screws. |
| 58 | Extra for Providing and fixing flush doors with decorative veneering instead of non decorative ISI marked flush door shutters conforming to IS: 2202 (Part I) BOTH SIDE |
| 59 | Extra for providing lipping with 2nd class teak wood battens 25 mm minimum depth on all edges of flush door shutters |
| 60 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with : 4.0 mm thick glass panes |
| 61 | Painting or varnishing on iron work in small areas or new wood work with one coat of ready mixed priming paint & one coat of approved superior quality ready mixed paint of clear synthetic varnish including supply of all materials, labour and T & P etc. required for proper completion of work. Paint to be used should confirm to the I.S.I. No. 103 1950 |
| 62 | Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer) of 1st quality conforming to IS : 15622 of approved make in colours such as White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand), Jointing with grey cement slurry @ 3.3 kg/sqm including pointing the joints with white cement and matching pigment etc., complete. |
| 63 | Steel work in built up tubular ( round, square or rectangular hollow tubes etc.) trusses etc. including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. Hot finished welded type tubes. |
| 64 | Providing and fixing precoated galvanised iron profile sheets (size, shape and pitch of corrugation as approved by Engineer-in-charge) 1.0mm (+ 0.05 %) total coated thickness with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineerin- charge. The sheet shall be fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 65 | Providing and fixing 15 cm wide, 45 cm overall semi-circular plain G.S. sheet gutter with iron brackets 40x3mm size, bolts, nuts and washers etc., including making necessary connections with rain water pipes complete. 0.80 mm thick with zinc coating not less than 275 gm/m² |
| 66 | Providing and fixing false ceiling at all heights with integral densified calcium silicate reinforced with fibre and natural filler false ceiling tiles of Size 595x595 mm of approved texture, design and patterns as per CPWD Specification 2019, to be laid in true horizontal level suspended on interlocking metal T-Grid of hot dipped galvanised iron section of 0.33 mm thick (galvanized @ 120 grams per sqm including both sides)comprising of main-T runners of size 24x38 mm of length 3000 mm,cross - T of size 24x32 mm of length 1200 mm and secondaryintermediate cross-T of size 24x32 mm of length 600 mm to formgrid module of size 600 x 600 mm, suspended from ceiling using galvanised mild steel items (galvanizing @ 80 grams per sqm) i.e. 12x50 mm long dash fasteners, 6 mm dia fully threaded hanger rod upto 1000 mm length and L-shape level adjuster of size 76x25x25x1.6 mm fixed with grid and Z cleat of size 25x37x25x1.6 mm thick with precut hole on both 25 mm flange to pierce into 12x50 mm or even bigger size dash fastener if require, fixed with Glavanised iron perimeter wall angle or size 24x24x0.40 mm of length 3000 mm to be fixed on periphey wall / partition with the help of plastic rawl plugs at 450 mm center to center and 40 mm long dry wall S.S screws. The work shall be carried out as per specifications, drawing and as per directionsof the Engineer-in-Charge. With 15 mm thick tegular/butt edged without perforation plain/designer light weight calcium silicate Anti-Microbial Bio-Safe coated false ceiling tiles Confirming to JIS-Z2801 and ASTM G-21 |
| 67 | Providing and fixing tiled false ceiling of specified materials of size 595x595 mm in true horizontal level, suspended on inter locking metal grid of hot dipped galvanized steel sections ( galvanized @ 120 grams/ sqm, both side inclusive) consisting of main \"T\" runner with suitably spaced joints to get required length and of size 24x38 mm made from 0.30 mm thick (minimum) sheet, spaced at 1200 mm center to center and cross \"T\" of size 24x25 mm made of 0.30 mm thick (minimum) sheet, 1200 mm long spaced between main \"T\" at 600 mm center to center to form a grid of 1200x600 mm and secondary cross \"T\" of length 600 mm and size 24x25 mm made of 0.30 mm thick (minimum) sheet to be interlocked at middle of the 1200x600 mm panel to form grids of 600x600 mm and wall angle ofsize 24x24x0.3 mm and laying false ceiling tiles of approved texture in the grid including, required cutting/making, opening for services like diffusers, grills, light fittings, fixtures, smoke detectors etc. Main \"T\" runners to be suspended from ceiling using GI slotted cleats of size 27 x 37 x 25 x1.6 mm fixed to ceiling with 12.5 mm dia and 50 mm long dash fasteners, 4 mm GI adjustable rods with galvanised butterfly level clips of size 85 x 30 x 0.8 mm spaced at 1200 mm center to center along main T, bottom exposed width of 24 mm of all T-sections shall be pre-painted with polyester paint, all complete for all heights as per specifications, drawings and as directed by Engineer-in-charge. 12.5 mm thick square edge PVC Laminated Gypsum Tile of size 595x595 mm, made of Gypsum plasterboard, manufactured from natural gypsum as per IS 2095 part I and laminated with white 0.16mm thick fire retardant PVC film on the face side and 12micron metalized polyester on the back side with all edges sealed with the face side PVC film which goes around and wraps the edges and is bonded to the edges and the back side metalized polyester film so as to make the tile a completely sealed unit. |
| 68 | Self Supporting slab |
| 69 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing of edges to give high gloss finish etc. complete at all levels. Granite stone slab of colour black, Cherry/Ruby red Area of slab over 0.50 sqm |
| 70 | Providing and fixing double scaffolding system (cup lock type) on the exterior side, up to seven story height made with 40 mm dia M.S. tube 1.5 m centre to centre, horizontal & vertical tubes joining with cup & lock system with M.S. tubes, M.S. tube challies, M.S. clamps and M.S. staircase system in the scaffolding for working platform etc. and maintaining it in a serviceable condition for the required duration as approved and removing it there after The scaffolding system shall be stiffened with bracings, runners, connection with the building etc wherever required for inspection of work at required locations with essential safety features for the workmen etc. complete as per directions and approval of Engineerin- charge .The elevational area of the scaffolding shall be measured for payment purpose .The payment will be made once irrespective of duration of scaffolding. This item to be used for maintenance work judicially, necessary deduction for scaffolding in the existing item to be done. |
| 71 | Providing edge moulding to 18 mm thick marble stone counters, Vanities etc., including machine polishing to edge to give high gloss finish etc. complete as per design approved by Engineer-in-Charge.IN Granite Work |
| 72 | Second class teak wood flooring 20mm thick |
| 73 | P/L Mat flooring. |
| 74 | Providing and fixing in position wall panelling at all heights with integral densified calcium silicate panels/tiles of size 595 x 595 mm, having NRC (Noise Reduction coefficient) of 0.50 (minimum) as per IS 8225:1987, Light reflectance of 85% (minimum). Non combustible as per BS:476 (part-4), fire performance as per BS:476 (part 6 &7), humidity resistanceof 100%, thermal conductivity <0.043 W/m K as per ASTM 518:1991, comprising of a frame made from especially fabricated galvanised mild steel sheet 0.50 mm thick pressed section (galvanizing @120 grams per sqm including both sides) i.e.vertical studs of size 48 x 34 x 36 mm are placed at 600 mm centre to centre in a floor and ceiling channel sectionof size 50 x 32 mm fixed to the floor and soffit at 600 mm centre using 12 mm dia,50 mm long wedge type expanded zinc alloy dash fastner with 10 mm bolt. This same channel is then to be fixed in horiziontal direction at 600 mm centre to centre so as to form a grid of 600 mm x 600 mm. Glasswool of 50 mm thickness is then to be inserted in the slots and finallycalcium silicate non combustible panels/tiles are to be screw fixed with self tapping pan head nickel coated mild steel screws of size 13 x 3.2 mm on to this grid leaving an even groove of 1 mm between the panels. The joints between the panels are to be duly jointed and finished usingrecommended jointing calcium silicate based compound and fiber joint tape roll 50 mm wide (90 metre )roll and two coats of primer suitable for panelling as per manufacturer’s specification as per direction of Engineerin- Charge all complete. With 15 mm thick fully perforated square/butt edge light weight calcium silicate panels/ tiles |
| 75 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1%:3 (1 Cement: 1% coarse sand (zone-lll) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 76 | Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete. All works upto plinth level : Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 77 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 78 | Providing and fixing glass strips in joints of terrazo/ cement concrete floors. 40 mm wide and 4 mm thick |
| 79 | Cement plaster skirting up to 30 cm height, with cement mortar 1:3 (1 cement : 3 coarse sand), finished with a floating coat of neat cement. 18 mm thick |
| 80 | 20mm thick cement plaster in two coats, backing coat 17mm and finishing coat 3mm thick (of neat cement of cement and marble dust in ratio 5:1) on rough side of single or half brick interior plastering upto floor two level including rounded angles. (1 cement : 4 coarse sand) |
| 81 | P/L 25mm thick kota stone flooring over 20mm thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid over jointed with grey cement slurry mixed with pigment to match the shade of slab including rubbing and polishing complete. |
| 82 | Supply and fixing 6mm china white glazed tiles in flooringlaid with 1:3 cemend and approved coarse sand mortar finished with white cement slurry, jointing and polishing complete inlcuding supply of all materials, labour and T&P etc. required of proper completion of the work. |
| 83 | Providing and fixing 18 mm thick gang saw cut, mirror polished, premoulded and prepolished, machine cut for kitchen platforms, vanity counters, window sills, facias and similar locations of required size, approved shade, colour and texture laid over 20 mm thick base cement mortar 1:4 (1 cement : 4 coarse sand), joints treated with white cement, mixed with matching pigment, epoxy touch ups, including rubbing, curing, moulding and polishing to edges to give high gloss finish etc. complete at all levels. Granite stone slab all colour and texture except black, Cherry/ Ruby red |
| 84 | Chequerred precast cement concrete tiles 22 mm thick in footpath & courtyard, jointed with neat cement slurry mixed with pigment to match the shade of tiles, including rubbing and cleaning etc. complete, on 20 mm thick bed of cement mortar 1:4 (1 cement: 4 coarse sand). Light shade pigment using white cement |
| 85 | Laying brick bats with mortar using broken bricks/brick bats 25 mm to 115 mm size with 50% of cement mortar 1:5 Providing and laying integral cement based water proofing treatment including preparation of surface as required for treatment of roofs, balconies, terraces etc consisting of following operations: Applying a slurry coat of neat cement using 2.75 kg/sqm of cement admixed with water proofing compound conforming to IS. 2645 and approved by Engineer-in-charge over the RCC slab including adjoining walls upto 300 mm height including cleaning the surface before treatment. (1 cement : 5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge over 20 mm thick layer of cement mortar of mix 1:5 (1 cement :5 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineer-in-charge to required slope and treating similarly the adjoining walls upto 300 mm height including rounding of junctions of walls and slabs. After two days of proper curing applying a second coat of cement slurry using 2.75 kg/ sqm of cement admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge.Finishing the surface with 20 mm thick jointless cement mortar of mix 1:4 (1 cement :4 coarse sand) admixed with water proofing compound conforming to IS : 2645 and approved by Engineerin- charge including laying glass fibre cloth of approved quality in top layer of plaster and finally finishing the surface with trowel with neat cement slurry and making pattern of 300x300 mm square 3 mm deep.The whole terrace so finished shall be flooded with water for a minimum period of two weeks for curing and for final test. All above operations to be done in order and as directed and specified by the Engineer-in-Charge :With average thickness of 120 mm and minimum thickness at khurra as 65 mm. |
| 86 | Providing and fixing aluminium sliding door bolts, ISI marked anodised (anodic coating not less than grade AC 10 as per IS : 1868), transparent or dyed to required colour or shade, with nuts and screwsetc. complete :250x16mm |
| 87 | Providing and fixing aluminium tower bolts, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868 ) transparent or dyed to required colour or shade, with necessary screws etc. complete :250x16mm |
| 88 | Providing and fixing aluminium handles, ISI marked, anodised (anodic coating not less than grade AC 10 as per IS : 1868) transparent or dyed to required colour or shade, with necessary screws etc. complete : 125mm |
| 89 | Signage work on Gate |
| 90 | Providing and fixing 150 mm bright finished floor brass door stopper with rubber cushion, necessary brass screws etc. to suit shutter thickness complete. |
| 91 | Providing & fixing oxidised iron sliding door bolts ISI markedcomplete. (a) 300mm x 16mm. |
| 92 | Providing & fixing oxidised iron tower bolts ISI markedcomplete. (a) 250mm x 16mm.(a) 250 mm x 10mm |
| 93 | (b) 200 mm x 10mm |
| 94 | Providing and fixing oxidised iron handle with screws etc. complete (a) 100 mm |
| 95 | Providing & laying \"brick Coba\" 120mm thick laid with M-150 class brick bat coba 7.50 cm thick with gap of 15mm to each other, over 20mm thick base of cement mortar 1:4 cement and coarse sand mixed with water proofing compound spreading cement slurry mixed with aereliccement concrete water proofing compound filled gaps of coba & top of coba mortar mixed with water proofing compound in 1:4 cement and coarse sand mortar finished smooth & top mashed false square 30 cm x 30 cm and side wall parapet shall be mono lythic plaster wall upto 30cm higher and junction and corner shall be rounded by brick ballast cement and coarse sand masonry coba with top finished plaster mixed with acetic water proofing compound @ 2% by weight & including S/o all material, labour T & P etc complete for proper completion of work. |
| 96 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 97 | Providing and laying vitrified floor tiles in different sizes (thickness to be specified by the manufacturer) with water absorption less than 0.08% and conforming to IS : 15622, of approved make, in all colours and shades, laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand), including grouting the joints with white cement and matching pigments etc., complete. |
| 98 | Providing & fixing Stainless steel sliding door bolts ISI marked to required colour or shade with nuts and screws etc complete. (a) 250mm x 16mm |
| 99 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete.(a) 250 mm x 10mm |
| 100 | Providing and fixing stainless steel towerbolts (barrel type) with necessary screws etc. complete. (a) 200 mm x 10mm |
| 101 | Providing and fixing stainless steel handles with screws etc. complete (a) 100 mm. |
| 102 | Treatment of soil under existing floors using chemical emulsion @ one litre per hole, 300 mm apart including drilling 12 mm diameter holes and plugging with cement mortar 1 :2 (1 cement : 2 Coarse sand) to match the existing floor: With Chlorpyriphos/Lindane E.C. 20% with 1% concentration |
| 103 | Surface dressing of the ground including removing vegetation and inequalities Earth work in surface excavation not exceeding 30 cm Providing and laying in position ready mixed or site batched design mix cementconcrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/ Ordinary Portland /Portland Slag cement, admixtures in recommended proportions nd laying in position cement concrete of specified grade excluding the cost of centering and shuttering Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting Green cricket net Half brick masonry with common burnt clay F.P.S. (non modular) bricks of class designation 7.5 in foundations |
| 104 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing tocamberandconsolidatingwithroadroller including making good the undulationsetc. andre-rolling thesub grade and disposal of surplus earthwith lead upto 50 metres. (As per Track area measurement sheet attached) Grading-1 |
| 105 | Grading-2 |
| 106 | Grading-3 |
| 107 | Providing and applying tack coat with bitumen VG-10 using bitumen distributor at the rate of 0.35 kg per sqm on the prepared bituminous surface cleaned with hydraulic broom as per Technical Specification Clause 503 |
| 108 | 2 cm premix carpet surfacing with 1.8 cum and 0.90 cum of stone chippings of 13.2 mm size and 11.2 mm size respectively per 100 sqm and 52 kg and 56 kg of hot bitumen per cum of stone chippings of 13.2 mm and 11.2 mm size respectively, including a tack coat with hot straight run bitumen, including consolidation with road roller of 6 to 9 tonne capacity etc. complete (tack coat to be paid for separately) With paving Asphalt grade VG - 10 heated and then mixed with solvent at the rate of 70 grams per kg of asphalt |
| 109 | Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road surface, including rolling and finishing with power road roller all complete. |
| 110 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 111 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors whereverrequired : W.C. pan with ISI marked white solid plastic seat and lid |
| 112 | Providing and fixing water closet squatting pan (Indian type W.C.pan ) with 100 mm sand cast Iron P or S trap, 10 litre low fixtures complete, including cutting and making good the walls andlevel white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and floors wherever required : White Vitreous china Orissa pattern W.C. pan of size 580x440 mm with integral type foot rests |
| 113 | Providing & fixing white vitreous china wash basin with C.I. brackets painted white, 15 mm C.P. brass pillar taps, C.P. brass chain with rubber plug, 32mm C.P. brass waste of standerd pattern including cutting & making good the walls wherever required.a)White Vitreous China Wash basin size 550x400 mmwith a pair of 15 mm C.P. brass pillar taps |
| 114 | Providing and fixing white vitreous china flat back half stall urinal of size 580x380x350 mm with white PVC automatic flushing cistern, with fittings, standard size C.P. brass flush pipe, spreaders with unions and clamps (all in C.P. brass) with waste fitting as per IS : 2556, C.I. trap with outlet grating and other couplings in C.P. brass, including painting of fittings and cutting and making good the walls and floors wherever required : Single half stall urinal with 5 litre P.V.C. automatic flushing cistern |
| 115 | Providing and fixing P.V.C. waste pipe for sink or wash basin including P.V.C. waste fittings complete.Semi rigid pipe 32 mm dia |
| 116 | Providing and fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washers complete. |
| 117 | Providing and fixing PTMT soap Dish Holder having length of 138mm, breadth 102mm, height of 75mm with concealed fitting arrangements, weighing not less than 106 gms. |
| 118 | Providing and fixing PTMT towel rail complete with brackets fixed to wooden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour. 600 mm long towel rail with total length of 645 mm, width 78 mm and effective height of 88 mm, weighing not less than 190 gms. |
| 119 | Providing and fixing C.P. brass bib cock of approved quality conforming to IS:8931 a) 15 mm nominal bore |
| 120 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls whereverrequired:- |
| 121 | Providing and fixing wash basin with C.I. brackets, 15 mm dia CP Brass single hole basin mixer of approved quality and make, including painting of fittings and brackets, cutting and making good the walls wherever required:- (a) White Vitreous China Wash basin size 550x400 mm with a 15 mm CPBrass single hole basin mixer |
| 122 | Providing and fixing flexible P.V.C. waste pipe for sink or wash basin including PVC waste fittings complete.a) 32mm dia |
| 123 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: a) One urinal basin with 5.0 litre white P.V.C. automatic flushing cistern Parryware/ Hindware Seabird/ Orient (Coral) |
| 124 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour.Waste coupling 38 mm dia of 83 mm length and 77 mm breadth, weighing not less than 60 gms |
| 125 | Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. |
| 126 | Providing & fixing 600x450mm bevelled edge mirror of superior glass (of approved quality) complete with 6mm thick asbestos cement sheet ground fixed to wooden cleats with C.P. brass screws and washers. |
| 127 | Providing and fixing white vitreous china flat back or wall corner type lipped front urinal basin of 430x260x350mm and 340x410x265mm sizes respectively with automatic flushing cistern with standard flush pipe and C.P. brass spreaders with brass unions and G.I. clamps complete, including painting of fittings and brackets, cutting and making good the walls and floors wherever required: a) Range of three urinal basins with 10litre white P.V.C. automatic flushing cistern |
| 128 | Providing and fixing on wall face unplasticised Rigid PVC rain water pipes conforming to IS : 13592 Type A including jointing with seal ring conforming to IS: 5382 leaving 10 mm gap for thermal expansion . (i) Single socketed pipes. a) 110mm diameter |
| 129 | Providing and fixing on wall face unplasticised - PVC moulded fittings/ accessories for unplasticised Rigid PVC rain water pipes conforming to IS:13592 Type A,including jointingwithsealringconformingtoIS: 5382, leaving 10 mm gap for thermal expansion. Single Push Fit Coupler 110 mm dia |
| 130 | Plain bend 87.5 deg110 mm dia |
| 131 | Shoe (Plain) 110 mm Shoe |
| 132 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over P.V.C. sheet 1 m x1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement, rounding the edges and making and finishing the outlet complete. |
| 133 | Providing and fixing unplasticised -PVC pipe clips of approved design to unplasticised - PVC rain water pipes by means of 50x50x50mm hard wood plugs, screwed with M.S. screws of required length including cutting brick work and fixing in cement mortar 1:4 (1 cement : 4 coarse sand) and making good the wall etc. complete. a) 110mm |
| 134 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc.For Internal Toilet15 mm nominal outer dia Pipes |
| 135 | 20 mm nominal outer dia Pipes |
| 136 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge.Internal work - Exposed on wall 20 mm nominal bore |
| 137 | Providing and fixing GI pipes complete with GI fittings and clamps, i/c cutting and making good the walls etc. Internal work - Exposed on Wall 20 mm nominal bore |
| 138 | 25 mm nominal bore |
| 139 | 32 mm nominal bore |
| 140 | Providing , checking, storing, fixing in positionof approvedqualityScrewed ends Brass float valvewith brassballfloatandPTFE seat suitable forBody test pressure of 15Kg/sqcm of the following sizes: 40mm |
| 141 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved quality for new work :20mm diameter pipe |
| 142 | 25mm diameter pipe |
| 143 | 32mm diameter pipe |
| 144 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete : 25 to 40 mm nominal bore |
| 145 | Providing and fixing 45 cm long unplasticised PVC connection pipe with brass unions. a) 15mm nominal bore |
| 146 | Providing and fixing C.P. brass long nose bib cock of approved quality conforming to IS standards and weighing not less than 810 gms. a) 15mm nominal bore |
| 147 | Providing & fixing C.P. brass angle valve for basin mixer and gyser points of approved quality conforming to IS 8931 a) 15mm nominal bore |
| 148 | Providing and fixing ball valve (brass) of approved quality complete.(High or low pressure with plastic floats). a) 25mm. Nominal bore |
| 149 | Providing and fixing gun metal gate valve with wheel of approved quality. a) 25mm dia nominal bore |
| 150 | b) 32mm dia nominal bore |
| 151 | c) 40mm dia nominal bore |
| 152 | Providing and placing on terrace (at all floor levels) polyethylene water storage tank of approved brand and manufacture with cover and suitable locking arrangement and making necessary holes for inlet, outlet and overflow pipes but without fittings and the base support for tank. Capacity 11000 litre |
| 153 | Excavating trenches in all kind of soil of required width for pipes, cables etc. including excavation for sockets and dressing of sides, ramming of bottoms, depth upto 1.5 m.including getting out the excavated soil & then returning the soil as required,in layers not exceeding 20cm in depth including consolidating each deposited layer by ramming, watering, etc & disposig of surplus excavated soil as directed within a lead of 50m. a) Pipes 80mm to 300mm diameter. |
| 154 | Providing, laying and jointing glazed stoneware pipes grade \"A\" with stiff mixture of cement mortar in the proportion of 1:1 (1 cement : 1 fine sand) including testing of joints etc. complete.100mm diameter |
| 155 | Providing and laying cement concrete 1:5:10 (1 cement: 5 coarse sand : 10 graded stone aggregate 40mm nominal size) all roundS.W. pipes including bed concrete as per standard design100mm dia |
| 156 | Providing and fixing square-mouth S.W. gully trap grade‘A’ complete with C.I. grating, brick masonry chamber with water tight C.I. cover with frame of 300 x300 mm size (inside) the weight of cover to be not less than 4.50 kg and frame to be not less than 2.70 kg as per standard design 150 x 100 mm size P type With Sewer bricks conforming to IS : 4885 |
| 157 | Providing, fixing, jointing and testing,uPVCSWR pipes, - type B conforming to IS : 13592to wall, ceiling and floor, approved quality, complete, for soil, waste & rain water drain including pushfit jointing with seal ring. (i) Single socketed pipes.Internal Toilet (Soil & Waste Pipe) 75 mm |
| 158 | 110 mm |
| 159 | Exposed on Wall & up to Manhole (Soil & Waste Pipe) 110 mm |
| 160 | Exposed on Wall & up to Manhole (Soil & Waste Pipe)110 mm |
| 161 | Supply and fixing of UPVC S.W.R. pipe nahni trap size 100x75,110/90 mm confirming to IS-14735 self cleaning design fixed in PCC 1:2:4 and supply and fixing of 125 mm dia heavy duty CP brass jali. |
| 162 | Providing and fixing to the inlet mouth of rain water pipe cast iron grating 15 cm diameter and weighing not less than 440 grams. |
| 163 | Making khurras 45x45 cm with average minimum thickness of 5 cm cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate of 20 mm nominal size) over PVC sheet 1m x 1 m x 400 micron, finished with 12 mm cement plaster 1:3 (1 cement : 3 coarse sand) and a coat of neat cement,punning,rounding the edges and making and finishing the outlet complete. |
| 164 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply including all CPVC plain & brass threaded fittings i/c fixing the pipe with clamps at 1.00m spacing.This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testiang of joints complete as per direction of Engineer in Charge.Concealed work including cutting chases and making good the walls etc. 20mm dia nominal outer dia pipes |
| 165 | 25mm dia nominal outer dia pipes |
| 166 | Providing and fixing Chlorinated Polyvinyl Chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, including fixing the pipe with clamps at 1.00 m spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and testing of joints complete as per direction of Engineer in Charge. Internal work-Exposed on wall15mm dianominal bore |
| 167 | 20mm dianominal bore |
| 168 | Providing and fixing gun metal gate valve with wheel of approved quality.20mm dia nominal bore |
| 169 | 25mm dia nominal bore |
| 170 | Providing and fixing brass stop cock of approved quality. b) 20 mm nominal bore |
| 171 | Providing M.S. foot rests including fixing in manholes with 20x20x10 cm cement concrete blocks 1:3:6 (1 cement:3 coarse sand :6graded stone aggregate 20 mm nominal size) as per standard design With 20x20 mm square bar |
| 172 | Providing and fixing in floor and wall face Ringfit UPVC ASTRAL/EQUIVALENT ULTRADRAIN Conventional system for soil and waste water pipes conforming to (HSN CODE: 3917) Type B including jointing with seal ring. (i) Double socketed pipes. a) 110mm dia P.V.C. pipe |
| 173 | b) 90mm dia P.V.C. pipe |
| 174 | Providing & fixing UPVC Floor trap of self cleansing designwith CP Jalicomplete in all respects. (Make : Supreme / Finolex / Prince) P-Trap type Floor Trap 110 x 90mm |
| 175 | Providing and fixing on wall face unplasticised - PVC moulded fittings/accessories for unplasticised Rigid PVC pipes including jointing with seal ring leaving 10 mm gap for thermal expansion. 110mm bend |
| 176 | 90 mm bend |
| 177 | Coupler 110mm |
| 178 | 90mm |
| 179 | Single tee with door 90x90x90 mm |
| 180 | 110x110x110 mm |
| 181 | Constructing masonry Chamber 90x90x100 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100 mm top diameter, 160 mm bottom diameter and 180 mm deep (inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : With common burnt clay F.P.S.(non modular) bricks of class designation 7.5 |
| 182 | Constructing brick masonry chamber for underground C.I. inspection chamber and bends with bricks in cement mortar 1:4 (1 cement : 4 coarse sand) C.I. cover with frame (light duty) 455x610 mm internal dimensions, total weight of cover with frame to be not less than 38 kg (weight of cover 23 kg and weight of frame 15 kg), R.C.C.Inside dimensions 500x700 mm and 45 cm deep for pipe line with one or two inlets : With common burnt clay F.P.S. (non modular) bricks of class designation 7.5 |
| 183 | Providing and fixing square mouth S.W. Gully trap grade \"A\" complete with C.I. grating brick masonry chamber with bricks of class M-150 and water tight C.I. cover with frame of 300 x 300mm.size (inside) the weight of cover to be not less than 4.50 Kg and frame to be not less than 2.70 Kg as per standard design. a) 150 x 100 mm. size P type |
| 184 | Constructing brick masonry manhole with class bricks M-150in cement mortar 1:4 (1 cement : 4 coarse sand) RCC top slab with 1:2:4 mix (1 cement : 2 coarse sand: 4graded stone aggregate 20mm nominal size); foundation concrete 1:4:8 mixa) Inside size 90x80 cm & 45 cm deep including C.I. cover with frame (light duty) total wt. of cover & frame to be not less than 38 Kg (wt. of cover 23 Kg & wt. of frame 15 Kg. With M-150 Bricks |
| 185 | Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC] |
| 186 | Providing and Fixing C.P. brass Ablution health faucet assembly with 1.2 m long braided PVC hose with mounting bracket fixed on wall complete.[FOR EWC] |
| 187 | Providing and fixing C.P. brass Two-way angle valve for EWC points & for fixing Ablution Health Fauct of approved quality conforming to IS:8931. 15 mm nominal bore |
| 188 | Transportion of camp. Shifting of rig M/C & its allied equipts. |
| 189 | Drilling of 350 mm to 450 mm dia hole by direct rotary rig M/c |
| 190 | Lowering of 12\" housing pipe Threaded |
| 191 | Lowering of 10\"B.P. Threaded |
| 192 | Lowering of 10\"slotted mtr. pipe Threaded |
| 193 | P/F Of 12\" M.S. Socket |
| 194 | P/F Of 10\" M.S. Socket |
| 195 | P/F Of 12\"\"/10\" M.S. Reducer |
| 196 | P/F of 12\"\" M.S. wall cap. |
| 197 | P/F of 10\"\" M.S. Bail plug. |
| 198 | Strata sample box of polythene bags. |
| 199 | P/F of Pea gravel. |
| 200 | Devolopment by air compr. 250 P.S.I. |
| 201 | Devolopment by O.P. unit |
| 202 | Transportion charge of air compr. & O.P. unit |
| 203 | Logging charge |
| 204 | Installation of pump set 17.5 Hp. K.S.B. make with 4\"\" M.S. column pipe starter 12.5 H.P.V. meter, A meter etc. |
| 205 | SITC Of Pannel As Per Design |
| 206 | SITC Of 35 Sqmm Cable 3core |
| 207 | Earth work in excavation by mechanical means (Hydraulic excavatior)/manual means over areas(exceeding 30cm in depth. 1.5m in width as well as 10sqm on plan) including disposal of excavated earth, lead upto 50m and lift upto 1.5m,laying in cement concrete 1:4:8 (1 cement :4 coarse sand :8 graded Stone aggregate 40 mm nominal size) and curing complete, M-150 brick work in 1:4 (one cement and six coarse sand sand of 2.25 fineness modulus) mortar infoundation & plinth including supply of all materials, R.C.C. work with cement approved coarse sand and 20 mm. guage approved stone grit im the proportion of 1:1.5:3 in Slab and windows excluding supply of reinforcement and its fixing and binding the same with 24 BWG binding wire and including necessary centering and shuttering etc, Fe-500 Mild steel or iron in plain work such as reinforced concrete or reinforced, brick work (when not included in over all rates ) wrought to required shape as necessary including bending for proper completion of the work, 15 mm cement plaster in single coat on rough side of single or half brick wall for interior plastering up to floor two level including internal rounded angles, fixing in position precast RCC manhole cover and frame of required shape and approved quality, Boring/drilling bore well of required dia for casing/ strainer pipe, by suitable method prescribed in IS: 2800 (part I), including collecting samples from different strata, preparing and submitting strata chart/bore log, including hire & running charges of all equipments, tools,Supplying, assembling, lowering and fixing in vertical position in bore well unplasticized PVC medium well screen, filling, spreading & leveling stone boulders of size range 5 cm to 20cm, in recharge pit, Gravel packing in tubewell construction in accordance with IS: 4097, including providing gravel fine/medium/coarse, in required grading |
| 208 | DRAINAGE NETWORK Constructing masonry Chamber 60x60x75 cm inside, in brick work in cement mortar 1:4 (1 cement : 4 coarse sand) for sluice valve, with C.I. surface box 100mm top diameter, 160 mm bottom diameter and 180 mm deep ( inside) with chained lid and RCC top slab 1:2:4 mix (1 cement : 2 coarse sand : 4 graded stone aggregate 20mm nominal size ) , i/c necessary excavation, foundation concrete 1:5:10 (1 cement : 5 coarse sand : 10 graded stone aggregate 40 mm nominal size) and inside plastering with cement mortar 1:3 (1 cement : 3 coarse sand) 12 mm thick, finished with a floating coat of neat cement complete as per standard design : With class-m-150 bricks |
| 209 | Excavating trenches in all kinds ofsoil of required width for pipes. including excavation for sockets and dressing of sides, ramming of bottoms, including getting out the excavated soil & then returning the soil as required, in layers not exceeding 20 cm in depth including consolidating each deposited layer by ramming, watering, etc & disposing of surplus excavated soil as directed within a lead of 50m.up to 1.50 m depth Pipes 80 mm to 300 mmdiameter |
| 210 | Providing and laying non-pressure NP2 class (light duty) R.C.C. pipes with collars jointed with stiff mixture of cement mortar in the proportion of 1:2 (1 cement : 2 fine sand) including testing of joints etc. complete : a) 150mm diameter |
| 211 | Providing & laying cement concrete 1:5:10 (1 cement :5 coarse sand :10 graded stone aggregate 40mm nominal size) alround S.W. Pipes including bed concrete as per standard design.150mm diameter |
| 212 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. Group C |
| 213 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 214 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. 2 X 1.5 sq. mm + 1 X 1.5 sq. mm earth wire |
| 215 | 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire |
| 216 | 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 217 | 2 X 6 sq. mm + 1 X 6 sq. mm earth wire |
| 218 | Supplying and fixing following way, horizontal type three pole and neutral (TPN), sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 4 way (4 + 12), Double door |
| 219 | 6 way (4 + 18), Double door |
| 220 | Supplying and fixing of following ways surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) 4 way (4 + 12), Double door |
| 221 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 222 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 223 | Providing and fixing following rating and breaking capacity and pole MCCB with thermomagnetic release and terminal spreaders in existing cubicle panel board including drilling holes in cubicle panel, making connections, etc. as required. 100 A,30KA,FPMCCB |
| 224 | Supply and fixing of 40 Amp. TP MCB (10 KA) C Curve. CAT A |
| 225 | Supply and fixing of 63 Amp. TP MCB (10 KA) C Curve. CAT A |
| 226 | Supply and fixing of40 Amp. FP MCB (10 KA) C Curve. CAT A |
| 227 | Supply and fixing of 63 Amp. FP MCB (10 KA) C Curve. CAT A |
| 228 | Supplying and fixing following rating, four pole, (three phase and neutral) SPN, 415 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required. 40 A |
| 229 | 63 A |
| 230 | Providing and fixing M.V. danger notice plate of 200 mm X 150 mm, made of mild steel, at least 2 mm thick, and vitreous enameled white on both sides, and with inscription in single red colour on front side as required. |
| 231 | Supplying and drawing following pair 0.5 sqmm FR PVC insulated annealed copper conductor, unarmoured telephone cable in the existing surface/recessed steel/PVC conduit as required.2 Pair |
| 232 | Supplying and drawing co-axial TV cable RG-6 graded, 0.7 mm solid copper conductor PE insulated,shielded with fine tinned copper braid and protected with PVC sheath in the existing surface/ recessed steel/ PVC conduit as required. |
| 233 | Supplying and fixing following modular switch/ socket on theexisting modular plate & switch box including connections but excluding modular plate etc as required. Telephone socket outlet |
| 234 | TV antenna socket outlet |
| 235 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75mm X 75 mm X 60mm Deep |
| 236 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc as required. 75mm X 75 mm X 60mm Deep |
| 237 | Extra for fixing the louvers / shutters complete with frame fro exhaust fans of all sizes. |
| 238 | Supplying and fixing modular blanking plate on the existing modular plate & switch box excluding modular plate as required. |
| 239 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 240 | Supply and Fixing of 36 Watt to 46 Watt above 3300 leumin indoor Recess mounting LED Square Fitting for Armstrong Ceiling having Powder coated die cast aluminium housing withextendedheat sink and diffuser of Special Polycarbonate meterial and driver set complete in all respect. |
| 241 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. |
| 242 | Supply and fixing of LED high bay light Fitting with mandatory driver set having die cast aluminium body and lenses suitable for 100 watt to 120 Watt. Confirming to IP65/66 protection having Company LOCO Engraved complete in all respect . |
| 243 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. |
| 244 | Supply and Fixing of LED Tube Light with batten suitable for up to 1X22 watt LED tube light fitting complete including tube on surface complete in all respect. |
| 245 | S/Fof single light wall bracket on matching M.D.F.E.G. board base etc. complete in all respects. |
| 246 | Supply and burying of 600mm x 600 mmx6mm G.I. plate, vertically for earthing with its top atleast 3 mts. below ground level complete with 20mm G.I.pipe and funnel for watering and two earthing leads of No.8to10SWG G.I.wire in 15mm diaG.I. pipe upto switch board (from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) 30cm. square C.I. frame with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. |
| 247 | Supply and burying of 40mm dia x 4.5 metres long G.I. pipe, vertically for earthing having 12mm dia. holes spaced 75mm apart drilled up to 2 metre from the bottom complete with earthing lead of No.6 to 8SWG G.I.wire in G.I. pipe upto appron (and from apron to switch board the cost of G.I. pipe and G.I. wire will be extra) upto switch board, 30cm. square C.I.box with hinged cover, masonary housing, alternate layers/of charcoal/ coke and salt at least 150mm thick alround etc. complete in all respects. |
| 248 | Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. |
| 249 | Supply & fixing of two number 8 SWG G.I. wire for earthing purpose as required complete in all respects. |
| 250 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep) and refilling etc as required. |
| 251 | Supply and fixing of factory wired integral LED flood lightluminaires with die cast aluminium housing built with dirver setsuitable for 120 Watt. Confirming to IP 65 protection completein all respect. .PWD APROVED WIPRO/BAJAJ/PHILLIPS/WMEL (pwd 1453) |
| 252 | Supply and fixing of surface/ flush mounting 6 way TPN distribution board with additional metal doorwithout MCB complete in all respect, as directed at site by Engineer Incharge. |
| 253 | Supply & fixing of Crimping, solder, less, copper ton electroplated lugs of Dowel/ismail make suitable for 1.5 sqmm to 6sqmm cables, including tapping with insulating tape,etc. complete in allrespects. |
| 254 | Supply and fixing of single pole MCB blanking plate CAT B |
| 255 | Erection and testing of ceiling fan and regulator for room height upto 3.5mts. including supply of 3mm thick G.I. down rod 19mm dia duly painted, complete in all respects. |
| 256 | Erection and testing exhaust fan on the exhisting hole with suitable size of rag bolts nuts and washers etc. complete in all respects. |
| 257 | Supply & fixing of 16 gauge M.S.drum duly painted including making hole in the wall for exhaust fan and finishing properlyetc. complete as required. |
| 258 | S/F of hexagonal fan box with hexagonal side of approx 80mm in length fabricated from 16 SWGM.S. sheet incorporating 10mm dia, M.S. round barduly bent for supporting fan hanger dully painted withred oxide and screwing arrangement with wiring conduit laid in the R.C.C. roof before concreting along with supply of all materials, labour T & P etc., for proper completion of work. |
| 259 | Supplyfixingofelectronic fan regulator (Modular) 120-280 V. ISImarked, on the existing switch board including making connetion, required material, labour T/P etc for proper completion of work to the satisfaction of Engineer in charge of work. |
| 260 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc.10 sqmm 2 core |
| 261 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc. 10 sqmm 2 core |
| 262 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 35 sqmm 3.5 core |
| 263 | Supply & fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respects. The armouring of the cable shall be properly connected with the earth as per dire 10 sqmm 2 core |
| 264 | Supplying and fixing of Palm / pin type copper tin plated cables sockets (lugs) to the cable leads, insuslating with tape and making of connections etc. complete in all respects as per direction of Engineer-Incharge. 35 Sq.mm |
| 265 | 10 sqmm |
| 266 | Supply and fixing of danger board fabricated from 10 gauge M.S. sheet as per I.E.rules. |
| 267 | Supply and laying of 1800mm x 900mm x 12mm thick chequered rubber matting of tested quality. |
| 268 | Supply & erection of AC 1200mm Sweep, 230/250 Volts, 50 Hz ceilling fan with standard down rod, blades including connection etc. complete as required-. |
| 269 | Supply & erection of AC 230/250 Volts, 50 Hz exhaust fans including providing nuts, bolts, mounting frame and other accessories including connections etc. complete as required- 300mm sweep. |
| 270 | Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type Power Panel :Incoming -100 Amp MCCB - 1 No.Outgoing - 63 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. 40 Amp 4P MCCB - 1 No. (for spare ) |
| 271 | Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type Power Panel : Incoming - 100 Amp MCCB - 1 No.Outgoing - 63 Amp 4P MCCB - 1 No. (for G.F. P.d.b.)40 Amp 4P MCCB - 2 No. (for G.F.& F.F. l.d.b.) 40 Amp 4P MCCB - 2 No. (for spare ) |
| 272 | Supply& Erracetionof factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreise Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release) Switches Complete and instrument chamber etc.complete in all respects.The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters (KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above insulated with heat shrink sleeving and mounted on non gyroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides.The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm.Cubicletype switchboard shall be of cat A & B Only. CAT. B Cubicle Type Power Panel : Incoming - 100 Amp MCCB - 1 No.Outgoing - 63 Amp 4P MCCB - 1 No. (for G.F. P.d.b.)40 Amp 4P MCCB - 2 No. (for G.F.& F.F. l.d.b.) 40 Amp 4P MCCB - 2 No. (for spare ) |
| 273 | Turbine Ventilator,Roof Ventilator 201 Stainless Steel Exhaust Cap Flue Waterproof Vent (Size : 200mm) |
| 274 | Supply and laying of aluminium conducter, PVC insulated armoured, served, sheeted cable 1000 bolts grade at a depth of 750mm below ground level over a cushion of 75mm thick sand alround and protected with burnt bricks on sides and top on surface, the cable run shall be fixed on M.S. clamps etc. of suitable size. or as directed by the Engineer-Incharge, complete in all respect. the armouring of the cable shall be properly connected with the earth conductor by clamps etc.50 sqmm 3.5 core |
| 275 | 25 sqmm 3.5 core |
| 276 | 10 sqmm 4.0 core |
| 277 | 10 sqmm 2.0 core |
| 278 | 6 sqmm 2.0 core |
| 279 | Supply and fixing of brass nickle plated compression gland for PVC insulated and armoured served sheathed, under ground cable including rubber ring etc. complete in all respects, the armouring of the cable shall be properly connected with earth as per direction of Engineer-in-charge.50 sqmm 3.5 core |
| 280 | 25 sqmm 3.5 core |
| 281 | 10 sqmm 4.0 core |
| 282 | 10 sqmm 2.0 core |
| 283 | 6 sqmm 2.0 core |
| 284 | Supply and fixing of palm or pin type copper tin plated cable socket (Lug) to the cable leads, insulating with tape, and making connections etc. complete in all respects as per directions of the Engineer-in-charge.50 Sq.mm |
| 285 | 25 Sq.mm |
| 286 | 10 sqmm. |
| 287 | 6 sqmm. |
| 288 | Supply and burring of Safe Earthing Electrode T-39 (Hot-Dip Galvanized), Length up to 3000mm, outer pipe 76mm inner Dia 38mm terminal Dia 12 mm ,outer GI pipe of 16 SWG and inner GI pipe of 12 SWG with Hot Dip Galvanization up to 100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30cm square C.I. frame with hinged cover & masonary housing. (From electrode terminal to switch board, cost of 25 X 3 GI. Strip will be extra) |
| 289 | Supplying & Laying of 25mmx3mm G.I. Strip for earthing purpose as required complete in all respects. |
| 290 | Supply and erection of steel tubular pole 7.5 meters long designated 410 SP-6 in 1:3:6 cement concrete foundation including excavation, back filling etc. complete in all respects. |
| 291 | Supply and Fixing ofservice bracket of 50mm. Dia 4 meter long fabricated from class \"\"B\"\" G.I. pipe complete with two bend, socket, wall clamps. 7/3.15 mm G.I. stay wire, stay insulators etc..complete in all respects. |
| 292 | Supply and fixing of LED street light fitting having diecast aluminium body and diffuser/reflector with driver set suitable for 45 watt to 50 Watt confirming to IP 65 protection complete in all respect. |
| 293 | 2.5sqmm aluminium conductor single core wire for connection from cable end box to flourescent tube. |
| 294 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contractors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN complete in all respect. |
| 295 | Providing, laying and fixing following dia RCC pipe NP2 class (light duty) in ground complete with RCC collars, jointing with cement mortar 1:2 (1 cement : 2 fine sand) including trenching (75 cm deep) and refilling etc as required. 100 mm Dia |
| 296 | Supplying and making Indor cable end termination with heat shinkkable jointing kit complete with all accessories including lugs suitable for following sozeof 3 core, XLPE aluminium conductor cable of 11 grade as required. 120 sq mm |
| 297 | Supplying and making Outdorr cable end termination with heat shinkkable jointing kit complete with all accessories including lugs suitable for following sozeof 3 core, XLPE aluminium conductor cable of 11 grade as required. 120 sq mm |
| 298 | Supply, & Erraction of factory fabricated & wired metal clad dust and vermin proof floor mounted,M.S. channel base with bottom and top cable entreis electrical control panel with TPN MCCB\"s (four pole 36 KA with thermal magnatic release ) switches complete and instrument chamber etc. complete in all respects. the instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase votage and single phase voltage, current and other parameters(KVA,PF,KW etc) in each phase with touchtype selector switches for different reading instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium basbar as per IS 8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. the MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc.the job includes the grounting of the board as per directions of Engineer-incharge. All out going of 100 Amp and above shall have an Ammeter. the panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. cubicle type switch board shall be of cat A & B only.Main L.T.Panel Incoming : 630 Amp. /415 Volt ACB - 1No Cat. B Panel Cubicale Type Metering :One (1) No. (0-500V) 96 x 96 Sqmm voltmeter with control fuse & selector switch. One (1) No. (0-630A) 96 x 96 Sqmm CT operated Ammeter with selector switch, CTs etc.One (1) Set of Phase Indication Lamp.Bus Bar :One (1) No.630 A, TPN aluminimum bus bar of suitable length.Outgoing : Phase indication lamps on each outgoing to be provided.200Amp MCCB - 2Nos. And 1 No. Extra @ 17200 63Amp MCCB - 2Nos.32Amp MCCB - 1No.OR outgoing as per site requirment |
| 299 | Making of following size of Cable Chamber made of 230 mm thick brick work in cement mortar (1 cement : 6 sand) with PCC 100 mm thick PCC base plastering of inner and outer surface with cement mortar including providing of Heavy Duty C.I Cover complete with digging, refilling and removal of surplus soil complete as required. 600 mm x 600 mmx 800 mm deep |
| 300 | Providing, laying, testing & Commissioning of\"C\" class heavy duty MS pipe confirming to IS 3589/IS1239 inculding welding, fittings like elbows,tees, langes,tapers,nuts bolts, gaskets etc. and fixing the pipe on the wall/ceiling with suitable clamp/support frame and painting with two or more coats of syntetic enamel paint of required shade complete as required: 25 mm dia |
| 301 | 80 mm dia |
| 302 | 100 mm dia |
| 303 | Supplying Installation testing & Commissioing of Butterfly Value PN-16 slim seal standard lever operated type as per design standard IS:1395 or BS:5155 with required flanges,nut,bolts etc. Complete in all respects. 100 mm |
| 304 | 80 mm |
| 305 | Supplying InstallationCommissioning of dual plate Non Return Value of following sizes PN-10 as per design standard IS:5312 or BS:1868 with companion flanges, nut, bolts etc. Complete in all respect. 150 mm |
| 306 | 100 mm |
| 307 | Supplying Installation testing & Commissioning of Manual Swing type Fire Hose Reel IS:444 complete with heavy duty reel, 19 mm dia 30 Mtr. Long. 2 ply polyster yarn braided rubber pressure hose, Red colored, SS jet nozzle 25 mm isolating value and all other necessary fixing accessories complete in all respect. |
| 308 | Supplying Installation testing & Commissioning of25 mm Air Release valve gunmental having rubber ball and with 25 mm BSP threaded male inlet including necessary accessories and connections complete in all respect. |
| 309 | Supplying InstallationCommissioning of25 mm Ball valve PN-1 gunmental as per IS:778 including necessary accessories and connections. |
| 310 | Providing / Fixing of Fire Hose cabinet box made out of 18 gauge MS sheet including two coats of post office red paint over one coat of primer with 4 mm, thick glass door in front painted \"FIRE\" in red luminous paint. The size of the boxshould be 750 mm X 600 mm X 250 mm size capable of accommodating a pair of hose with coupling and nozzle. The box should be floor mounted type with railway coach lock arrangement and lever for opening the door after breaking the glass complete. |
| 311 | Supplying fixing of Fire hose, RRL hose jacketed with circular woven synthetic fibre conforming to IS:636.88 63 mm dia X15 Mtr. Long with S.S. heavy duty, 63 mm, Painr of male and female instantaneous couling having IS: 903 mark and duly S.S. wire wounded. |
| 312 | Supplying fixing of S.S. Branch pipe, short type with 63 mm male instantaneous intel, male threaded outlet, fitted with 15 mm bore nozzle having IS:903 mark. Gun Metal |
| 313 | Providing / Fixing of Fire Fighting pump set suitable for automatic operation consisting of the following as per the specification. a) Horizontally mounted, centrifugal type single/multi stage fire pump having cast iron body, bronze impeller, stainless steel shaft and capable of delivering 450 LPM, 7.5 H.P against a total head of 52 mtrs. Complete with pressure gauge & gun metal cocks on delivery side including bypass arrangement. Terrace pump |
| 314 | Supplying Installation testing & Commissioning ofvertical air vessel fabricated from 6 mm thick MS plate with dished ends 250 mm dia DN 1.2 m high common for fire and jockey pump complete with spring loaded safety valve. Test pressure 12 kv/Sq.mm) |
| 315 | Supplying InstallationCommissioning ofpressure Gauge ranging from 0 to 14 kg. per sq.mm ISI marked from approved manufactures complete in all respect. |
| 316 | Supplying fixing of Cast iron body 63 mm dia male instantaneous intel coupling with housing cabinet (500X400X400 for 2 way and 600X400 for 4 way) cap and chain for fire brigade correction conforming to IS:904 and making connection with fire fighting pipe or underground water tank completing the work in all respect as per the directions of the Engineer-in-charge. (FIRE BRIGADE CONNECTION) Four way connection (4 way) |
| 317 | Providing/Fixing of cubical type floor mounted Fire pump control panel fabricated from 16 G M.S. sheet duly powder coated finish of approved shade and comprising of: a) One 63 amp. TP-NL M.C.C.B. with rotary handle of beacking capacity 35 KV. b) One Volt meter (0-500 V) with selector swich. c) One set including lamps. |
| 318 | Supplying and laying of Insulated PVC sheathed, Steel Aromed, Copper Aluminium Conductor, 1100V grade Powder Cable. The cable shall be laid in tray / in trenches/on wall/ floor etc. As required (Approx quantities only) 2 crore x 1.5 sq.mm Cu Cable |
| 319 | 3.5 crore X 25 sq.mm AL Cable |
| 320 | Supply and laying of aluminium conductor PVC insulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc. 150 sq. mm 3-1/2 core |
| 321 | 50 sq. mm 3-1/2 core |
| 322 | 35 sq. mm 3-1/2 core |
| 323 | 10 sq. mm 4 core |
| 324 | Supplying and fixing of Self Glow Exit signage for stairs and exists Complete in allrespects |
| 325 | Fire man axe |
| 326 | Pressure Switch |
| 327 | Supply & fixing of Single way landing/Hydrant / Yard Hydrant valve 63 mm dia.gun metal instantanuous with female coupling with chain etc. complete. |
| 328 | Supplying, installation, testing and commissioning of electric driven pressurisation pump suitable for automatic operation and consisting of following, complete in all respects, as required : (Jockey Pump) Horizontal type, multistage, centrifugal pump of cast iron body and bronze impeller with stainless steel shaft, mechanical seal conforming to IS : 1520. Suitable HP squirell cage induction motor TEFC type suitable for operation on 415 volts, 3 phase 50 Hz AC supply with IP 55 class of protection for enclosure, horizontal foot mounted type with Class-\"F\" insulation, conforming to IS : 325. M.S.fabricated Common base plate, coupling, coupling guard, foundation bolts etc. as required. Suitable cement concrete foundation duly plastered and with anti vibration pads. 300 lpm at 70 m Head. |
| 329 | Supplying InstallationCommissioning Intelligent Addressable 2 loop fire alarm control panel is able to connect 250 devices (Detector or Module) per loop in any combination with 20% spare address for detector in eachloop should have min. 854 char LCD multi-line QVGA LCD display complete with inbuilt additional seven customized pregrammable function switch for direct activation of any device or control along with three programmable LED\"s indication along with 9A power supply inbuilt min three Notification appliance circuit with sufficient power supply to drive sounder cum strobe unit along with inbuilt 50 AH UL listed battery charger along with required SMF batteries for 24 hours in normal condition. |
| 330 | Supplying Installation testing & Commissioning Intelligent Addressable photoele smoke detector with base as per specification with true alarm photo0 sensing technology selectable sensitivity from 0.2% to 3.7% / Ft, obscuration support digital communication and magnetically operated functional test. |
| 331 | Supplying Installation testing & Commissioning Intelligent Addressable type heat Dectector along with base as per specification rate of rise temperature range is at 8.3 dgree c/ 11.1 dgree c per min and fixed temperature sensing is independent of rate of rise sensing to operate at 57.2 dgree c/68 dgree c support digital communication and magnetically operated functional test. |
| 332 | Supplying Installation testing & Commissioning of Remote red LED alarm indicator on single gauge stainless steel plate. |
| 333 | Supplying Installation testing & Commissioning of Intelligent Addressable Manual Call points-double action Break Glass cum pull station suitable for wall/column mounting. |
| 334 | Supplying Installation testing & Commissioning of Intelligent Addressable Hooter cum multi carriar strobe, Unit as per specifications and customization of intensity selection as 15, 30, 75 or 110 cd of strobe unit is possible by panel. Sounder sum strobe will be driven by supervised 24 V DC input and will give 70 db output at 3 m strobe unite will be synchronized 1 Hz strobe flash rate for better evacuation in complete facility. |
| 335 | Supplying Installation testing & Commissioning Intelligent Addressable single Addressable Control Relay Module-Form \"C\" contact type. |
| 336 | Supply laying testing & Commissioning of 2 corex 1.5 sr.mm single standard copper conductor, PVX insulated armoured cable. |
| 337 | CO2 type extinguisher 4.5 kg. |
| 338 | ABC Type extinguisher 4 kg. |
| 339 | Supply and fixing of fire extinguisher ABC type 6.00 kg.capacity (ISI Marked IS : 15683 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper complition of work |
| 340 | Supply and fixing of fire extinguisher CO2 type 4.5.0 kg.capacity (ISI Marked IS : 2878 & TAC approved) complete with initial charge and wall bracket, along with supply of all materials and labour for proper complition of work |
| 341 | Supplying and erecting floor mounting stand for keeping 3 Nos. of FIRE buckets 1500mm in length, 900mm in height frame made out of 30x30x4 mm angle iron with cross supports for legs, welded with 3 hooks and duly painted with one coat of red lead and two coats of silver paint. |
| 342 | SITC of Cat-6 Cable ,4 Pair UTP 23 AWG |
| 343 | SITC of 25 MM PVC Conduit Medium with accessoriesbend & Junction Boxes |
| 344 | SITC of Camera Back Box PVC |
| 345 | SITC of Fix Type Dome Camera Suitable for day Night Operation with all the Accessories on Surface withback plate etc required as per technical specs. And 2MP IP IR Dome Camera 20 MTr IR DistanceFixed Lens2.8MM,Honeywell/Hikvision |
| 346 | SITC of Fix Type Bullet Camera Suitable for day Night Operation with all the Accessories on Surface withback plate etc required as per technical specs. And 2MP IP IR Bullet Cameralens 30MTr IR Distance TDN 12 VDC,4MM Lens Complete as Required MakeHoneywel/Hikvision |
| 347 | SITC of NVR Upto 16 Channel IP Camera Input Bandwith, HDMI/VGA Simultaneos output ,Supports Multi Brand Network Cameras onVIF Supports 2 SATA HDD , Make :Honeywell/Hikvision |
| 348 | 16 PortLayer 2 POE Switch 24 Rj 45,10/100/1000 Mbps (Supports POE )2 SFP ports ,120 watts Poe |
| 349 | SITC of 6U wall Mount Rack with PDU,FAN, Cable Manager, Hardware PktMake: Comrack/Topline/valRack |
| 350 | SITC of HDMI Cable 5 Mtr Make: Andtronics/honeywell |
| 351 | SITC of HDD 2TB Make: Toshiba/seagate/WD |
| 352 | SITC of 32 Inch Monitor Commercial Make: LG/Samsung/Panasonic |
| 353 | Camera InstallationInstallation Charges completeproject |
| 354 | NVR Configuration Charges |
| 355 | Providing Retro-reflective regulatory sign board of size 900 mm dia meter made out of 2 mm thick aluminium sheet, face to be fully covered with high intensity encapsulated lens type retro -reflective sheeting as approved by Engineer-in-charge . Letter, symbols, borders etc.4 m long welded to the frame with adequate anti-theft arrangement .Sheet work to be painted with two or more coats of synthetic enamel paint over an under coat (primer) and back side of aluminium sheet to be painted with two or more coats of epoxy paint including appropriate priming coat complete in all respects as per direction of Engineer-in-charge. |
| 356 | as per IRC : 67-2001 in silver white with blue colour back ground and with high intensity grade, pasted on substrate by pressure sensitive adhesive backing which shall be activated by applying pressure conforming to class II ofASTM-D-4956-01 and fixing the same to the plate of structural frame work by The rate includes the cost of rounding off the corners, lowering down the structural frame work from the gantry, fixing and erecting the same in position all complete as per drawings, specification and direction of the engineer-in-charge.(Structural frame work including M.S. plate to be provided separately. Rectangular area of the sheet only |
| 357 | Double side indicator |
| 358 | single side retro Reflective indicator |
| 359 | Two Seater Sofa, MS Powder Coated Leg, Wooden Frame, Leatherette Tapestry Three Seater Sofa |
| 360 | Conference Table, Particle Board Edge Banded Top, Without Pop Up Box W2100 X D900 X H750 |
| 361 | Executive Table, Particle Board Top W2300 X D1800 X H750 |
| 362 | Seater Sofa, Aluminium Arm And Leg, Powder Coated Cross Beam, Metal Insert PU Seat Back Size in mm - 1625(L) X660(D) X 870(H) , 3 Seater With 4 Arm |
| 363 | COST OF R.O. WITH WATER COOLER |
| 364 | Earth work in surface excavation not exceeding 30 cm in depth but exceeding 1.5 m in width as well as 10 sqm on plan including getting out and disposal of excavated earth upto 50 m and lift upto 1.5 m, as directed by Engineer-in- Charge: |
| 365 | Excavation of foundation in ordinary soil (loam clay or sand)includingliftupto1.50meterandleadupto30 meterandincludingfilling,wateringandrammingof excavatedearthintothetrenchesorintothespace between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earthasdirectedbytheEngineerinchargeuptoa distance of 30 meters from the foundation trenches. |
| 366 | Banking excavated earth in layers not exceeding 20 cm in depth, breaking clods, watering, rolling each layer with ½ tonne roller, or wooden or steel rammers, and rolling every 3rd and top-most layer with power roller of minimum 8 tonnes and dressing up, in embankments for roads,flood banks, marginal banks, and guide banks etc., lead upto 50 m and lift upto 1.5 m |
| 367 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete |
| 368 | Antitermite |
| 369 | Providing & making Drain on outer side of field . |
| 370 | Providing & making Drain on outer side of field . |
| 371 | Supply & Fixing Of Aluminium Goal Post Of FIH Aproved Drawing And Design Including Fitting & Net. |
| 372 | Preparation and consolidation of sub grade with power road roller of 8 to 12 tonne capacity after excavating earth to an average of 22.5 cm depth, dressing to camber and consolidating with road roller including making good the undulations etc. and re-rolling the sub grade and disposal of surplus earthwith lead upto 50 metres. |
| 373 | Providing,laying,spreadingandcompactingstoneaggregatesof specific sizes to GSB specification including spreading in uniform thickness, hand packing, rolling with 3 wheeled steel/ vibratory rollerin stages to proper grade and camber, applying and brooming requisite type of screening/ binding Materials to fill up the interstices of coarse aggregate, watering and compacting to the required density |
| 374 | Surface dressing on new surface in two coats with bitumen of gradeVG -10 of approved quality using 1.8 kg of bitumen per sqm with 1.5cum of stone chippings 13.2 mm nominal size per 100 sqm of roadsurface for first coat and 1.1 kg. of bitumen per sqm with 1.00 cu.metre of stone chippings 11.2 mm nominal size per 100 sqm ofroad surface for second coat, including consolidation of each coatseparately with road roller of 6 to 8 tonne capacity etc. complete |
| 375 | Providing and applying tack coat using hot straight run bitumen of grade VG - 10, including heating the bitumen, spraying the bitumen with mechanically operated spray unit fitted on bitumen boiler, cleaning and preparing the existing road surface as per specifications : On W.B.M. @ 0.75 Kg / sqm |
| 376 | Providing and laying seal coat over prepared surface of road with bitumen heated in bitumen boiler fitted with the spray set spraying using 98 kg of bitumen of grade VG - 10 and blinding surface with 0.90 cum of stone aggregate of 6.7 mm size (Passing 11.2 mm sieve and retained on 2.36 mm sieve) per 100 sqm of road surface, including rolling and finishing with power road roller all complete. |
| 377 | Dense Graded Bituminous Macadam Grading 2 Providing and laying dense graded bituminous macadam with higher capacity batch type HMP using crushed aggregates of specified grading, premixed with bituminous binder @ 4.5 per centby weight of total mix and filler, transporting the hot mix to work site, laying with a hydrostatic paver finisher with sensor control to the required grade, level and alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compaction as per MoRTH specification clause No. 505 complete in all respects. |
| 378 | Bituminous Concrete Grading 2Providingandlayingbituminousconcretewith highercapacitybatchtypehotmixplantusing crushed aggregates of specified grading, premixed with bituminous binder @ 5.4per cent of mix and filler, transporting the hot mix to work site,layingwithahydrostaticpaverfinisherwith sensorcontroltotherequiredgrade,leveland alignment, rolling with smooth wheeled, vibratory and tandem rollers to achieve the desired compactionasperMORTHspecificationclause No. 507 complete in all respects |
| 379 | ProvidingandlayingofAcrylicflooringCategory3 (Mediumpace)8LayersSyntheticAcrylicstandard system i) 1 layer of Primer (8 Layers Synthetic Acrylic Layer System(ii) 1 layers of Re-surfacer (iii) 4 layer of fine cushion (iv) 2 Layers of Acrylic ColourWith Game line marking . |
| 380 | Cost of Carted Earth filling from 5 KM |
| 381 | Cost of Net for Volly Ball court |
| 382 | Supply & Installation sprinkler system specially designed for design for synthetic sports hockey surface including all fittings and acceseries including carriage of material within all leads and lifts other incidental rates are inclusive of all taxes excluding GSTSprinkler |
| 383 | 1\" Size Swing Joint |
| 384 | 1\" Size Brass Quick coupling valve |
| 385 | 1\" Size Brass Q.C.V. key |
| 386 | 1\" Size Brass Swivel Elbow |
| 387 | 2\" Size Isolation valve |
| 388 | 2\" Size Air Release Valve |
| 389 | 12\" Size Rectangular Green cover Plastic valve box |
| 390 | 10\" Size Round Green Cover Plastic Valve Box |
| 391 | 2\" Size Solenoid valve |
| 392 | 14 AWG White Direct Burial copper wire |
| 393 | 16 AWG Red Direct Burial copper wire |
| 394 | Misc. Items i.e., DBY, DBR, Electric tape etc |
| 395 | Pressure Switch |
| 396 | 2\" Size Disc filter 30 Cum/Hr. |
| 397 | Installation testing & commissioning |
| 398 | Trenching & Back filling charges |
| 399 | 150mm dia CPVC Pipe From Tube Well To Outer Ring |
| 400 | 100 mm dia CPVC Pipe ForOuter Ring PN - 10 Pipe, 160 mm OD (SDR-11) |
| 401 | Heavy duty PVC fittings & accessories |
| 402 | S/L SYNTHETIC HOCKEY SURFACE F.I.H. Approved unfilled global category Synthetic hockey surface. Excluding of sub-base , jointing & fixing the same on the asphalt sub base as per F.I.H. requirement and specification for global category F.I.H. competitions. |
| 403 | Providing & Laying Shock pad thickness : 10 mm made on site by mixing rubber granules with Polyurethane binder. |
| 404 | Chain Link Fencing consisting of 3.0 Mt high 12 gauge 2 \" dia pipes of mild steel spaced 10 ft apart on all four sides of the court with one gate. The top and bottom of the chain link will have 1 ½” dia pipes and the chain link will of 3 mm thick GI wire spaced 2\" apart. [A.R.] |
| 405 | Cost of C.C. Interlocking |
| 406 | Excavation of foundation in ordinary soil (loam clay or sand) including lift upto 1.50 meter and lead upto 30 meter and including filling, watering and ramming of excavated earth into the trenches or into the space between the building and sides of foundation trenches or into the plinth and removal and disposal of sur-plus earth as directed by the Engineer incharge up to a distance of 30 meters from the foundation trenches. 0.00 to 1.50 mtr. |
| 407 | 1.50 to 3.00 mtr. |
| 408 | Providing and laying in position ready mixed or site batched designmix cement concrete for plain cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana/Ordinary Portland /Portland Slag cement, admixtures in recommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering and finishing as per direction of the engineer-in-charge; for the following grades of concrete.All works upto plinth level : 4.20.1.1 Concrete of M10 grade with minimum cement content of 220 kg /cum |
| 409 | Providing and laying in position ready mixed or site batched design mix cement concrete for reinforced cement concrete work; using coarse aggregate and fine aggregate derived from natural sources, Portland Pozzolana / Ordinary Portland /Portland Slag cement, admixtures inrecommended proportions as per IS: 9103 to accelerate / retard setting of concrete, to improve durability and workability without impairing strength; including pumping of concrete to site of laying, curing, carriage for all leads; but excluding the cost of centering, shuttering, finishing and reinforcement as per direction of the engineer-in-charge, for the following grades of concrete.: Note: Extra cement up to 10% of the minimum specified cement content in design mix shall be payable separately. In case the cement content in design mix is more than 110% of the specified minimum cement content, the contractor shall have discretion to either re-design the mix or bear the cost of extra cementConcrete of M25 grade with minimum cementcontent of 330 kg /cum As in item no. 3above but for slabs |
| 410 | As in item 3 abovebut inR.C.C.Raft foundation and footingwithapproved stone ballast.M30 grade with minimum cement content of 350 kg /cum |
| 411 | As in item 4 abovebut inColumn withapproved stone ballast. M30 grade with minimum cement content of 350 kg /cum |
| 412 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level. Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 413 | Cement concrete flooring 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate) finished with a floating coat of neat cement, including cement slurry, but excluding the cost of nosing of steps etc. complete.40 mm thick with 20 mm nominal size stone aggregate |
| 414 | Water Proofing of Tank Making angle fillet at wall and bottom junction point of swimming pool by Polymer modified mortar. 3- Supply and apply one coat Dr Fixit polymer or krystline coating, two coats Dr Fixit Fastflex coating with protection plaster and second layer waterproofing with only two coats Dr Fixit Fastflex coating with protection plaster |
| 415 | Centering and shuttering including strutting, propping etc. and removal of form for: Suspended floors, roofs, landings, balconies and access platform. |
| 416 | Foundations, footings, bases of columns, etc. for mass concrete |
| 417 | Columns, Pillars, Piers, Abutments, Posts and Struts |
| 418 | Add Extra For 10 HP CF Pump |
| 419 | P/f Of Sand seprator/ sand filter |
| 420 | Add extra for external pipe fitiings |
| 421 | S/F of Water trays for foot wash at entrance gate |
| 422 | S&F of 63 Amp. 415 V metal clad TPN HRC type switch fuse unit complete with HRC fuse on angle iron bracket complete in all respect. |
| 423 | S&F of SINGALE unit LED aviation obstructin ligth complete with transformer and LED spiral stccomplete in all respect. |
| 424 | Supply and fixing of 25 mtr High mast Pole of approved make with rising system, hot dip Galvanized inside & outside, having pole sheet thickness 4mm,top dia minimum150mm, bottom dia minimum 460mm, base plate 32mm thick, suitable for wind velocity as per IS 875 part 3 &.having no circumferential weld, with accessories for high mast such as head frame suitable for 8 to 12 luminaries & its control gear boxes,1.5 HP Power tool motor, 3 point suspension system with steel wire rope 8 mm dia,double drum winch. Including making suitable Foundation as per manufacture drawing & site requirement along with foundation bolts, nuts, washers, anchor plates etc Complete in all respect as per direction and satisfaction to the Engineer-in-charge. |
| 425 | Supply and burrying of 75 mm Dia 1 Mtrs. Long Electrode casted with maintenance free, conductive concrete, non corrosive mixture ( Ultra low Resistive carbon 0.001 ohm/Mtr) in the ratio of 3:1:1 (marconite : cement : water) on M.S. Rod wiih hole (16 mm diameter X3 Mtrs ) will be vertically installed for earthing with 1 Mtr G.I strip (25 mm X 2.5mm) connected with SS nut bolt. The earth electrode will be installed into the 100 mm pit up to 3000 mm depth. noraml soil will be used as backfill material. Make : As approved in U.P.P.W.D & C.P.R.I. Certified. |
| 426 | Supply of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following sizesas required complete with in all respect. 70 sq. mm 3-1/2 core |
| 427 | Supply and fixing of brass nickle plated compression gland for PVC insulated & armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer-Incharge Size 50 Sq mm x 3.5 core |
| 428 | Supply and fixing of plain or pin type copper tin plated cable socket ( lug ) to the cable leads, insulating with tape and making connection etc. complete in all respect as per direction of the Engineer-Incharge.70 sq. mm |
| 429 | Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect |
| 430 | Supply and fixing following capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with box with CTs etc. in case of TPN, complete in all respect.40 A TPN |
| 431 | Supply & Erracetion of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entreis Electrical control panel with TPN MCCB\"s (Four Pole 36 KA with thermal magnatic release)Switches Complete and instrument chamber etc.complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic alumininum busbars as per IS8623 or above istulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with deteachable side covers and shall be suitable for extension on the sides. The MCCB\"s shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat A & B Only.Incoming 400 Amp. MCCB-1 Nos. Outgoing 100 Amp.MCCB-3Nos. & 63 Amp.MCCB-2Nos.Cat. B. Pannel Cubicle Type |
| 432 | Providing, laying and fixing following dia G.I. pipe (medium class) in ground complete with G.I. fittings including trenching (75 cm deep)and re-filling etc as required |
| 433 | Supply and fixing of Of BVP485 LED 370 CW FLNB PSU SPD GR (philips) |
| 434 | Wiring pointfor light & Plug with 1.5 Sq.mm FR PVCinsulated multistrand single core copper conductor cable in PVCconduit with 1.5 Sq. mm FRLSH PVC insuleted multisand copper conductor cable as earth wire drawn inside.continuity wire. Modular typeswitch & socket etc. complete in all respect. withModular Box & Cover plate. |
| 435 | Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. |
| 436 | S/F of 6 To 32 amp MCB Complete in all respect. |
| 437 | S/F of DP MCB 40 Amp Complete in all respect. |
| 438 | Supply and wiring of 4 number 25 sq. mm. PVC insulated 1100V grade single core copper conductorcable in 50 mm dia PVC conduit concealed in wall, with two number 16sq mm single core copper conductor cable as earth continuity wire drawn in coudit including matching colour wash etc. complete in all respect. |
| 439 | Supply & fixing of plain type aluminium lug to the cable leeds included with tape and making connection etc. |
| 440 | Same as above but wiring on surface with copper cable in steel conduit. |
| 441 | S&F ofKit Katfuse 500 AMP Havells / Anchor make WithNutral Link |
| 442 | Supply&fixingof10mtrGIOctagonal Pole of approved make (top dia 100 mm, Bottom dia 200 mm and base plate 16mm thick) having 3 mm thikness with Double arm bracket 1 Mtr length in 1:2:4 RCC foundation bolt including the cost of foundation, excavation & back filling and Required T&P completee in all respect |
| 443 | Supply and burying of safe earthing electrode T-19 (Hot Dip Galvanized) length upto 3000 mm, outer G.I. Pipe 76 mm, Inner Pipe Dia 25, terminal dia 12mm,outerG.I.pipeof16SWGand inner G.I. pipeof 12SWG withHot Dip Galvanizedupto100micronfilledwith crystalline conductive mixture (CCM) having anti corrosive and conductive property with 50 Kgs activated soil (BFC) capableofreducingthesoilresistivity withgoodmixtureofretainingcapacity andoneearthingleadof 25mm x3 mmG.I.strip uptoswitchboard(from apron to switch board the cost G.I. strip willextra)alongwith30cmsquareC.I. frame with hinged over & masonry husing . |
| 444 | SupplyofonenumberPVCinsulated andPVC sheathed/ XLPE power cable of1.1KVgradeoffollowingsizes as required complete with in all respect. 25 sq. mm 4 core |
| 445 | Supplyandfixingofbrassnickleplated compressionglandforPVCinsulated& armoured served sheathed, underground cable including rubber ring etc. complete in all respect. The armouring of the cable shall be properly connected with the earth as per direction of Engineer- Incharge. Size25 Sq mm x 3.5core |
| 446 | Supplyandfixingofplainorpintype copper tin plated cable socket ( lug) to the cable leads, insulating with tape and makingconnectionetc.completeinall respect as per direction of the Engineer- Incharge.Size25 Sq mm |
| 447 | Supply and laying of 32mm x 6mm copper strip from earth electrode directly in the ground as required complete in all respect |
| 448 | Providing, laying and fixing following diaG.I. pipe (medium class) in ground completewithG.I.fittingsincluding trenching(75cmdeep)andre-fillingetc as required |
| 449 | Supply and fixing of Of BVP485 LED 560 CW NB PSU SPU GR (Philips) |
| 450 | Supplyandfixingfollowingcapacityof automatic street light cubicle control panelpaintedwithanticorrosivealkali andacidproofpaintconsistingoftime switchTSO100serieswithcontactors, HRC fuses, isolating switch metering instrument&instrumentboxwithbox with CTs etc. in case of TPN,complete in all respect.40 A TPN |
| 451 | Wiringforcircuit/submainwiring alongwithearthwirewiththefollowing sizesof FRLSPVCinsulatedcopper conductor,singlecorecableinsurface/ recessed medium class PVC conduit as required. 2 X 4 sq. mm + 1 X 4 sq. mm earth wire |
| 452 | S&F of 32 Amp. 415 Vmetal clad TPN rewireable type switch fuse unit onM.D.F.E.G. / Teak wood board complete in allrespect. Cat B |
| 453 | M.S. Pole for Net including foundation as per drawing & design |
| 454 | Transportion of camp. Shifting of rig M/C & its allied equipts. |
| 455 | Drilling of 350 mm to 450 mm dia hole by direct rotary rig M/c |
| 456 | Lowering of 12\" housing pipe Threaded |
| 457 | Lowering of 10\"B.P. Threaded |
| 458 | Lowering of 10\"slotted mtr. pipe Threaded |
| 459 | P/F Of 12\" M.S. Socket |
| 460 | P/F Of 10\" M.S. Socket |
| 461 | P/F Of 12\"\"/10\" M.S. Reducer |
| 462 | P/F of 12\"\" M.S. wall cap. |
| 463 | P/F of 10\"\" M.S. Bail plug. |
| 464 | Strata sample box of polythene bags. |
| 465 | P/F of Pea gravel. |
| 466 | Devolopment by air compr. 250 P.S.I. |
| 467 | Devolopment by O.P. unit |
| 468 | Transportion charge of air compr. & O.P. unit |
| 469 | Logging charge |
| 470 | Installation of pump set 17.5 Hp. K.S.B. make with 4\"\" M.S. column pipe starter 12.5 H.P.V. meter, A meter etc. |
| 471 | SITC Of Pannel As Per Design |
| 472 | SITC Of 35 Sqmm Cable 3core |
| 473 | Supply and Installation of 100.0 KVA D.G. SET |
| 474 | Providing & Fixing and Making SELFI POINT |
| 475 | Providing & Fixing and Making ARMY SCULPTURE |
| 476 | Supply & Providing Make Sintex DUSTBIN |
| 477 | Supply and Installation of SPLIT A.C. FOR OFFICE 1.5 TON |