| Sl. No. | Item Description |
| 1 | SCHEDULE \"A\" E/M |
| 2 | Taking down carefully burnt out aluminium/copper point wiring (light, fan, socket or power) complete (fittings such as switches, ceiling roses, pendent, regulators, sockets, fluorescent tube light fittings etc., to be measured and paid for separately) removing materials to store for schedule of credit and making good to the disturbed surfaces of walls ceilings and floors etc., Complete all as specified and directed by Engineer-in-Charge. |
| 3 | Disconnecting of unserviceable sub main wiring of any size and including steel conduit and accessories & removing from site and making good the disturbed surfaces including painting, complete all as specified and directed by Engineer-in-Charge. |
| 4 | Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors in existing conduit/ Provision of PVC casing capping as per site requirement size conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed casing capping, modular cover-plates and frame, complete all as specified in IS: 732- 1989, Complete all as specified and directed by Engineer-in-Charge.NOTE: Circuit wire from DB to switch boards shall be included in quoted rate. Note (i) Existing Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of existing size is to be replace and rate are deemed to be included in quoted rate.(iii) PVC casing capping measured and paid under relevant Item. |
| 5 | One light/ Bulb Holder/fan/exhaustpoint / bell point controlled by one, one way switch |
| 6 | One light point controlled by 2, Two way switch |
| 7 | One 5 pin socket outlet 5/6 amps on thesame board. |
| 8 | One 5 pin socket oulet 5/6 amps on independent board. |
| 9 | Material & Labour for point wiring using ISI marked 1.1 kV grade single core FR-LSH flexible cable, conforming to IS: 694- 1990, having multi drawn thin strands of electrolytic copper conductors, conforming to IS: 8130- 1984 and insulation conforming to IS: 5831- 1984, for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size PVC medium grade surface/recessed casing capping conforming to IS: 537 (Part 3)- 1983, colour-coded as specified in IS: 11353- 1985, and including modular cover plates complete all as specified in IS: 732- 1989, Complete all as specified and directed by Engineer-in-Charge. Note:- (i) Existing Modular sheet metal box should not be removed (ii) Mounting plate and cover plate of existing size is to be replace and rate are deemed to be included in quoted rate. |
| 10 | One 16 A socket outlet, independent, with cables 2.5 mm² size |
| 11 | Supply & fixing in replacement ofmodular type 6 A one-way SP switch, conforming to IS: 3854-1997 with finger proof terminal, Complete all as specified and directed by Engineer-in-Charge. |
| 12 | Supply & fixing replacement of modular type 16 A one-way SP switch, conforming to IS: 3854- 1997 with finger proof terminal, Complete all as specified and directed by Engineer-in-Charge. |
| 13 | Supply & fixing replacement of modular type 2/3 pin combined shuttered type 6 A socket conforming to IS: 1293- 2005, Complete all as specified and directed by Engineer-in-Charge. |
| 14 | Supply & fixing replacement of modular type 2/3 pin combined shuttered type 6/16 A socket conforming to IS: 1293- 2005, Complete all as specified and directed by Engineer-in-Charge. |
| 15 | Supply & fixing replacement of modular type 6 A bell-push conforming to IS: 8884- 1978 with finger proof terminal, Complete all as specified and directed by Engineer-in-Charge. |
| 16 | Supply & fixing replacement of Bell multi music type 230 Volt, Complete all as specified and directed by Engineer-in-Charge. |
| 17 | Supply & fixing in replacement of modular type 120 W step fan regulator of 2 module size, conforming to IS: 11037-1984, Complete all as specified and directed by Engineer-in-Charge. |
| 18 | Supply & fixing in replacement of 6 A, 250 V high quality robust surface/flush type polycarbonate/PVC ceiling rose, conforming to IS: 371- 1979, having 2/3 terminals and outside diameter not less than 63.5mm, Complete all as specified and directed by Engineer-in-Charge. |
| 19 | Supply & fixing in replacement of Modular switch 2 way 6A, 1 module, Complete all as specified and directed by Engineer-in-Charge. |
| 20 | Supply & fixing in replacement of PVC Modular surface box, Complete all as specified and directed by Engineer-in-Charge.Surface box of following sizes:- |
| 21 | 1 or 2 Module of size 85x 85 mm |
| 22 | 3 Module of size85x 115 mm |
| 23 | 4 Module of size 85x 145 mm |
| 24 | 6 Module of size 132x 135 mm |
| 25 | Supply & fixing in replacement of Modular cover plate with frame, Complete all as specified and directed by Engineer-in-Charge.Cover plate with frame of following sizes:- |
| 26 | 1 or 2 Module of size 85x 85 mm |
| 27 | 3 Module of size85x 115 mm |
| 28 | 4 Module of size 85x 145 mm |
| 29 | 6 Module of size 132x 135 mm |
| 30 | Supply & fixing in replacement of switch piano flush button, 240 volts, 6 amps, single pole, one way (ISI marked), Complete all as specified and directed by Engineer-in-Charge. |
| 31 | Supply & fixing in replacement of Socket outlet 2 in 1, 3 pin, 5amp flush type(ISI marked), Complete all as specified and directed by Engineer-in-Charge. |
| 32 | Supply & fixing in replacement of Socket outlet 3 pin, 16 Amp, flush type, Complete all as specified and directed by Engineer-in-Charge. |
| 33 | Supply & fixing in replacement of switch piano flush button 230 V, 16 Amps, Single pole, oneway ISI marked complete all as specified and directed. |
| 34 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 12 way type, Complete all as specified and directed by Engineer-in-Charge. |
| 35 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, single pole and neutral 240V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for 8 way type, Complete all as specified and directed by Engineer-in-Charge. |
| 36 | Supply & Fixing in replacement of MCB DB sheet enclosure double door type, Triple pole and neutral 415V with standard bus bar of suitable size plate and common neutral link all enclosed in standard steel sheet flush mounting type factory fabricated complete without MCB and with enclosure blank plates for unused way suitable for TPN 4 way type, Complete all as specified and directed by Engineer-in-Charge. |
| 37 | Material & Labour for sub main wiring using ISI marked 1.1 kV grade single core FRLS flexible cable, conforming to IS: 694- 1990, having multi-drawn thin strands of electrolytic copper conductors and insulation conforming to IS: 5831- 1984, type C, HR 85° C + FR for phase, neutral and earth continuity conductor connecting to earth dolly, drawn in not less than 25mm size in existing conduits / PVC Casing capping surface/recessed conforming to IS: 9537 Part- 3, colour-coded as specified in IS: 732- 1989, including making good of disturbed surfaces of wall/ceiling/floor with painting, Complete all as specified and directed by Engineer-in-Charge.NOTE: 01 run of phase conductor, 01 run of neutral conductor, 01 run of earth continuity conductor and 01 run of PVC Casing capping shall be measured as one length. |
| 38 | 2 x 6.0 Sqmm + 1 x 6.0 Sqmm earth wire |
| 39 | 2 x 4.0 Sqmm + 1 x 4.0 Sqmm earth wire |
| 40 | Supply & fixing in replacement of casing capping of 25x 12 mm size, Complete all as specified and directed by Engineer-in-Charge. |
| 41 | Supply & fixing in replacement of casing capping of 32x16 mm size, Complete all as specified and directed by Engineer-in-Charge. |
| 42 | Taking down ceiling fan 1200mm/1400mm sweep and Exhaust fan upto 250mm sweep complete servicing, repair of fan motor and replacement of worn out parts such as bearing and hanging of ceiling fan/Exhaust fan in situ, Complete all as specified and directed by Engineer-in-Charge.Note: (i) Rewinding of fan motor will be measured and paid separately. |
| 43 | Dismantling of fan (1200mm sweep) motor, cutting of burnt winding of rotor and rewinding with same gauge copper wire winding with insulated material andreassembling, Complete all as specified and directed by Engineer-in-Charge. |
| 44 | Dismantling ofExhaust fan 250/300mm sweep motor, cutting of burnt winding of rotor and rewinding with same gauge copper winding wire with insulated material and reassembling, Complete all as specified and directed by Engineer-in-Charge. |
| 45 | Supply & fixing in repair of wall mounted LED Tube light fitting 1 x 10W LED (6500K), 2 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, Complete all as specified and directed by Engineer-in-Charge. |
| 46 | Supply & fixing in repair of wall mounted LED Tube light fitting 1 x 20W LED (6500K), 4 feet, Sleek and seamless profiled extruded aluminium batten with an efficient diffuser to illuminate work, including making connections with 2 core flexible copper wire 0.50 Sqmm from ceiling rose after fixing fitting, Complete all as specified and directed by Engineer-in-Charge. |
| 47 | Supply & Fixing in replacement of LED Luminaires recessed mounted down lighter 18 watt 5700K system efficiency not less than 100lm/watt, thd<10% single phase including connecting cable from ceiling rose to terminal block of luminaires, Complete all as specified and directed by Engineer-in-Charge. |
| 48 | Supply & Fixing in replacement of 6 W LED spot light with multiple beam tilting angles, no UV radiation and dimmable ballast, complete all as specified and directed by Engineer-in-Charge. |
| 49 | Supply & fixing in repair of square shape slim recessed mounted LED down light of capacity 36 Watt (2ft x 2ft) with die cast housing finished in white powder coating, Complete all as specified and directed by Engineer-in-Charge. |
| 50 | Supply & fixing in replacement of Bldg Security light fitting LED type 25 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and including driver unit etc., Complete all as specified and directed by Engineer-in-Charge. |
| 51 | Supply & Fixing in replacement of LED flood lights 100W, aluminium die cast housing withpurity lenses for facade lightning with glare free light distribution enhancing accent lighting,including fixing arrangements etc., Complete all as specified and directed by Engineer-in-Charge. |
| 52 | Supply & fixing in replacement street light fitting LED type 70 watts with Pressure die cast aluminium housing with high power LED as lighting source and lens embedded PC cover having TOP Opening separate driver compartment with IP66 protection and including driver unit etc., Complete all as specified and directed by Engineer-in-Charge. |
| 53 | Supply & Fixing in replacement of LED Bollard 11W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, 50 Hz, pole mounted, including PCC 1:2:4 type B1 (20mm graded aggregate) base of size 300mm x 300mm and depth 600mm for fixing of Bollard with nuts bolts etc required as per site, Complete all as specified and directed by Engineer-in-Charge.Note: Apply for single coat of suitable colour distempering for bollard foundation shall deemed to be included in the quoted rate. |
| 54 | Supply & Fixing in replacement of LED Bollard 10W, IP 65, Die cast aluminium housing with polycarbonate cover, operating voltage 220-240 V, pole mounted,including PCC 1:2:4 type, base of size 300mm x 300mm and depth 500mm for fixing of Bollard with nuts bolts etc required as per site, Complete all as specified and directed by Engineer-in-Charge. |
| 55 | Supply & Fixing in replacement of automatic street light switch (5 KW to 8 KW) Amps rating 20 Amps NATURE SWITCH for automatic switching of streets lights based on lux level of natural light. The sensor (nature switch) along with suitable power contactor, MCB and support terminals should be enclosed in pole /wall mountable enclosure made out of rust proof, electric shock proof, termite proof and FR grade special moulding compound conforming to IP-54. The contactor, MCB and circuit wiring 16/10 sqmm copper shall be suitable, Complete all as specified and directed by Engineer-in-Charge. |
| 56 | Supply & Fixing in replacement of Pole box with 6 Amps MCB provision and suitable connector for single hose connections loop in and out 10 to 16 Sqmm 4 core aluminium armoured cable branch out 1.5 Sqmm single core copper PVC insulated cable enclosed in a thermoplastic polycarbonate enclosure which should be shock proof safe IP 66/67 weather proof, rust proof, dust proof, water proof, internally embedded gasket with provision for cable entry through IP 66/67 thermoplastic metric size glands and/or grommets enclosure size (155 x 210 x 92mm ), fixing arrangement and clamps including making connections, Complete all as specified and directed by Engineer-in-Charge.(Cat Part No KF 1616 Gof Make :Hensel or equivalent model of Sintex) |
| 57 | Material & Labour for apply two coat of epoxy paint on LT Panels of any size, including preparation of rusted surface of panel by means of sand paper/scrubbing of dust etc and apply one coat of epoxy based primer before painting,Complete all as specified and directed by Engineer-in-Charge.Note: Minor repair/ replacement of hinges suitable for screw fasteners and fixed in original position deemed to be included in unit rate. |
| 58 | Material & Labour for preparation of old painted surfaces of Steel Tubular pole upto 9 Mtr long by scarping old paint and applying Single coat of Aluminium paint including numbering of pole with black oil paint and painting the base of the pole in alternate black and Blue stripes each 30 cm (5 Strips) apart up to 1.5 Mtr height and including one coat white distempering for pole foundation above ground level shall deemed to be included in the quoted rate etc., Complete all as specified and directed by Engineer-in-Charge. |
| 59 | Dismantling and taking down the existing defective street light fitting of any type and any capacity LED street light from steel tubular pole, opening the street light fitting, checking the serviceability, remove the cable carbon and replacement of 3 Core 1.5 Sqmm size multi-stranded copper conductor including taking down old Unserviceable 3 Core 1.5 Sqmm size copper conductor, Complete all as specified and directed by Engineer-in-Charge.Note:- 1.5 Sqmm 3 core size multi-stranded copper conductor etc will be measured and paid separately. |
| 60 | Supply & fixing in replacement of Multi standard Copper Conductor cable of size 1.5 Sqmm 3 Core, inclusive of all tees, bends, elbows, reducers and fixing accessories such as couplers, lock nuts, saddles, pipe hooks etc. for interconnection of cable light/looping box to street light fitting etc., Complete all as specified and directed by Engineer-in-Charge. |
| 61 | Supply & fixing in replacement of Digital time switches (SST 15 min) for street light 215 V single Phase, Complete all as specified and directed by Engineer-in-Charge. |
| 62 | Supply & fixing in replacement of Aluminum lugs long barrel of size 300 Sqmm, Complete all as specified and directed by Engineer-in-Charge.Make: Dowells or equivalent |
| 63 | Supply & fixing in replacement of Aluminum lugs long barrel of size 185 Sqmm, Complete all as specified and directed by Engineer-in-Charge.Make: Dowells or equivalent |
| 64 | Supply & fixing in replacement of Aluminum lugs long barrel of size 150 Sqmm, Complete all as specified and directed by Engineer-in-Charge.Make: Dowells or equivalent |
| 65 | Supply & fixing in replacement of Aluminum lugs long barrel of size 120 Sqmm, Complete all as specified and directed by Engineer-in-Charge.Make: Dowells or equivalent |
| 66 | Supply & fixing in replacement of Aluminum lugs long barrel of size 95 Sqmm, Complete all as specified and directed by Engineer-in-Charge.Make: Dowells or equivalent |
| 67 | Supply & fixing in replacement of Aluminum lugs long barrel of size 70 Sqmm, Complete all as specified and directed by Engineer-in-Charge.Make: Dowells or equivalent |
| 68 | Supply & fixing in replacement of Aluminum lugs long barrel of size 50 Sqmm, Complete all as specified and directed by Engineer-in-Charge.Make: Dowells or equivalent |
| 69 | Supply & fixing in replacement of Aluminum lugs long barrel of size 25 Sqmm, complete all as specified and directed by Engineer-in-Charge. Make: Dowells or equivalent |
| 70 | Supply & fixingin replacement MCB/MCCB FP, 415 V fixed type, including taking down of old Unserviceable panel after disconnecting Existing cables and reconnecting the cables with proper lugs and glands, Complete all as specified and directed by Engineer-in-Charge.of following:- |
| 71 | MCCB 63/100 Amp FP, 415 V breaking capacity25 KA |
| 72 | MCCB 200 Amp FP, 415 V breaking capacity50 KA |
| 73 | MCCB 250 Amp FP, 415 V breaking capacity 50 KA |
| 74 | MCCB 320 Amp FP, 415 V breaking capacity 50 KA |
| 75 | MCCB 400 Amp FP, 415 V breaking capacity 50 KA |
| 76 | MCCB 630 Amp FP, 415 V breaking capacity 70 KA |
| 77 | MCB 40/63 Amps FP, 415 V breaking capacity 10 KA |
| 78 | MCB 6 TO 32Amps SP, 240 V breaking capacity 10 KA |
| 79 | Supply & Fixing in replacement AC Single Phase Static Energy meter of Accuracy Class 1.0, 240V, 50Hz, with Backlit LCD Display, of rating 10-60A (Measures & Displays kWh, kVAh, V, I, kW, PF, six month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in Absence of Power, Complete all as specified and directed by Engineer-in-Charge. |
| 80 | Supply & Fixing in replacement AC Three Phase Static Energy meter of Accuracy Class 1.0, 3 X 240V, 50Hz, with Backlit LCD Display, of rating 10-60A (Measures & Displays kWh, V, I, kW, PF, Hz, Last month history of kWh & MD in kW) with special features like TOD, Tamper logging, Optical Communication Port & Display in absence of Power, Complete all as specified and directed by Engineer-in-Charge. |
| 81 | Material and labour for painting of the transformer 250 KVA to 630 KVA, RMU, VCB and CSS Body complete by removing old paint by scrapping and providing spray painting with epoxy paint of approved (suitable for existing colour) make duly marking/writing MES/SM No., Complete all as specified and directed by Engineer-in-Charge. |
| 82 | Taking out UNSV HT UG cables of any sizes from trenches, Complete all as specified and directed by Engineer-in-Charge. |
| 83 | Supply, Laying, connecting, testing and commissioning and jointing, HT under-ground cable of size 185 Sqmm 3 core, 11000 volts grade, XLPE insulated screened PVC bedded, armoured with galvanised round steel wire or steel strip, electric power cables heavy duty, with multi stranded aluminium conductor, laid in Trenches, ducts, fixed on poles/walls with proper size saddles and clamp laid under roads/ path/drain/ culverts or encased in GI pipe fixed & testing and commissioning, Complete all as specified and directed by Engineer-in-Charge. |
| 84 | Supply & fixing Cable jointing kit for 11 KV (Earthed) grade cable for Straight through Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to 185 Sqmm, Complete all as specified and directed by Engineer-in-Charge. |
| 85 | Supply & fixing Cable jointing kit for 11 KV (Earthed) grade cable for Indoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size 120 to185 Sqmm, complete all as specified and directed by Engineer-in-Charge. |
| 86 | Supply & fixing Cable jointing kit for 11 KV (Earthed) grade cable for Outdoor type termination Heat shrink type joint complete with jointing material and accessories suitable for 3 core XLPE armoured aluminium conductor cable of size120 to185 Sqmm, Complete all as specified and directed by Engineer-in-Charge. |
| 87 | Supply & fixing in replacement air break switch triple pole, 11KV, mechanically operated mounted on insulators and steel frame, with operating mechanism worked from ground level, for current rating up to 200 amps complete withincluding insulators horizontal /vertical rod and operating pipe of suitable size and length including jumper connections and reconnecting of suitable size and length and making connection to new AB switch gang operated, Complete all as specified and directed by Engineer-in-Charge. |
| 88 | Preventive Maintenance and Servicing, 11/0.433 KV Step down Transformer Indoor and Oil Cooled type by disconnecting carefully electric connection on primary & secondary side, checking both side HT bushing, bushing rod, opening top cover of the transformer by unscrewing nuts, bolts, washers etc, rectify the oil leakages issues, if noticed any from the entire body of the transformer, during servicing and re-fixing the top cover of transformer according to previous system. Servicing of the transformer must be done through OEM or authorised personnel including maintaining and submitting the inspection and testing records of each transformer to the Engr-in-Charge.Note 1. :-Inspection of transformer shall involve :-(a)Checking of all clamps, nuts, bolts including core bolts & cover fixing bolts etc. (b)Checking all brazing’s, joints, tap heads, gaskets and connection joints.(c)Checking all terminations / connections inside/outside the transformer.(d)Checking of off load tap changer assembly, checking the moving and fixed contacts for contact wear and connection to winding. (e)Conducting the test on core and windings as per IS like ratio, magnetic imbalance, short circuit, IR Value, High Voltage Test etc. in presence of Engr-in-Charge. Note 2. :Spares usedbushes studs HT/LT, bushing rod HT/LT, transformer oil, filtration of oil, buchholtz relay, Gaskets set, Off Load Change over switch etc will be measured and paid separately under respective item of BOQ.Note 3 :- The rates quoted against the item is deemed to be included for cost of Labour for lifting/transporting to civil workshop and vice-versa, if required as per site requirement. Locations CGRA Dharampur |
| 89 | 250 to 630 KVA |
| 90 | Material & Labour for Dehydration/Filtration of transformer oil at site by means of centrifuging machine in order to improve dielectric strength of oil as per IS-355. Break down voltage should not be less than 50 KV, Complete all as specified and directed by Engineer-in-Charge. |
| 91 | Material & Labour for Transformer oil having di-electric strength of 60 KV as per IS complete for top up/ replacement, complete all as specified and directed by Engineer-in-Charge. (Oil should be supplied in sealed barrel of Power/Transol brand)Note: oil shall be filled in the transformers/stabilizers to be repaired or installed at site at different locations. |
| 92 | Supply & fixing in replacement Silica Gel (Moisture absorbent chemical ) for breather of transformer 11 KV /433 Volt of any make / rating, Complete all as specified and directed by Engineer-in-Charge. |
| 93 | Supply & fixing in replacement oil temperature indicator gauge suitable for transformer of capacity 11KV/433 Volt, Complete all as specified and directed by Engineer-in-Charge. |
| 94 | Supply & fixing in repair of LT bushings with brass studs complete washer with nuts bolts and washers of brass of suitable size for 250 KVA to 630 KVA transformer, Complete all as specified and directed by Engineer-in-Charge. |
| 95 | Supply & fixing in repair of HT bushing with brass studs complete washer with nuts bolts and washers of brass of suitable size for 250 KVA to 630 KVA transformer, Complete all as specified and directed by Engineer-in-Charge. |
| 96 | Material & Labour for Maintenance/Over hauling of RMU (1 No incoming, 2 No’s outgoing) of outdoor type no extensible 11 KV, SF6insulated compact ring main unit (RMU) with short circuit peak making current 50 KA and short circuit breaking current 20 KA fully arc proof metal enclosed free standing floor mounting manually operated fixed type SF6 insulated, 2 Nos. Load break switches 400 Amps (as incoming) and 1 No SF6 circuit breaker 200 Amps (as outgoing), by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioningof HT RMUby employingthe Skilled trades man and helper, Complete all as specified and directed by Engineer-in-Charge. Note: Rate Include following:- (i) Replacement of Mechanical indication in the front in the mimic for open & close breaker/isolator/ earth switch and Manual push button for emergency trip. etc., all as specified and as directed by Engineer - In - Charge.(ii) Disconnect the HT cables in Test position, Check the megger value of RMU terminals with body by suitable HT megger of range 5000 Volt and check the serviceability of Earthing connection by Earth megger note down the readings. |
| 97 | Material & Labour for Maintenance/Over hauling of Compact Substation outdoor type (CSS), 630 kVA Transformer,11kV Ring Main Unit consisting of 2 Nos (01 No In Coming & 02 Nos Out Going) &630A at 11kV fault making load breaking switch with one no SF6 insulated Vacuum Circuit Breaker & with LT Panel comprising of 1000 Amp ACB as secondary side, by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioningof HT RMUby employingthe Skilled trades man and helper, Complete all as specified and directed by Engineer-in-Charge.Note: Rate Include following . (i) Replacement of Mechanical indication in the front in the mimic for open & close breaker/isolator/ earth switch and Manual push button for emergency trip. etc., all as specified and as directed by Engineer - In - Charge.(ii) Replacement of Digital volt meter, Amp Meter , Power factor meter and CT of Ratio 1000/5 for RYB Phase in LT Panel |
| 98 | Material & Labour for Maintenance/Over hauling of HT VCB 11 KV (1 No incoming, 3 Nos outgoing) by taking shunt down with prior intimation and cleaning of HT VCB by using air blower, tightening the control circuit, Checking the all fuses, to ensure the smooth functioningof HT VCBby employingthe Skilled trades man and helper, Complete all as specified and directed by Engineer-in-Charge.Note: Rate Include following (i) Replacement of small piece of wire of sq area up to 1.5 sqmm Control Ckt cable) of Max length 5 Mtrs and replacement of Unserviceable indicator lamps asper colour code all as specified and as directed by Engineer- In - Charge. (ii) Rack out /Down the HT VCB kept in Test position, Check the megger value of VCB terminals with body by suitable HT megger of range 5000 Volt and check the serviceability of Earthing connection by Earth megger note down the readings. |
| 99 | Supply & fixing in replacement of charging motor suitable for 11 KV VCB 400 Amps as per existing make and model,Complete all as specified and directed by Engineer-in-Charge. |
| 100 | Supply & fixing in replacement of closing coil 24Volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge. |
| 101 | Supply & fixing in replacement of Tripping coil 24 Volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge. |
| 102 | Supply & fixing in replacement of Finger contacts for 2 Nos suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge. |
| 103 | Supply & fixing in replacement of auxiliary metal contacts suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge. |
| 104 | Supply & fixing in replacement ofindication LED lights for each phase of 230Volt, Complete all as specified and directed by Engineer-in-Charge. |
| 105 | Supply & fixing in replacement of automatic selector switch 230Volt 6 Amp, complete all as specified and directed by Engineer-in-Charge. |
| 106 | Supply & fixing in replacement of master Trip Relay 110volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge. |
| 107 | Supply & fixing in replacement of Auxiliary Relay 110 Volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, complete all as specified and directed by Engineer-in-Charge. |
| 108 | Supply & fixing in replacement of protection Relay (over short Circuit /earth fault) 110 volt DC suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge. |
| 109 | Supply & fixing in replacement of space heater and Thermostat set suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge. |
| 110 | Supply & fixing in replacement of Multifunction Meters (MFM) suitable for 11 KV VCB 400 Amps as per existing make and model, Complete all as specified and directed by Engineer-in-Charge. |
| 111 | Excavation in trenches not exceeding 1.5 Metre wide and not exceeding 1.5 Metre in depth and getting out in hard/dense soil, Complete all as specified and directed by Engineer-in-Charge. |
| 112 | Returning filling in including spreading levelling watering and well Ramming in layers not exceeding 25 cm thick , Complete all as specified and directed by Engineer-in-Charge. |
| 113 | Removing excavated material not exceeding 50 Metre and depositing where directed at a level not exceeding 1.5 Metre above the starting point, Complete all as specified and directed by Engineer-in-Charge. |
| 114 | Laying only un-reinforced precast concrete cable cover class HV, type-I, flat size 300mm x l80mm x 40mm laid cable cover to be reused, Complete all as specified and directed by Engineer-in-Charge. |
| 115 | Material & Labour for cutting existing road/hard standing not exceeding 45 x 45 cm in wide & depth getting out excavated material for laying cable/GI tube, returning filling & well ramming watering finish surface 10 cm from top using PCC 1:2:4; including removal of surpluses soil, Complete all as specified and directed by Engineer-in-Charge. |
| 116 | Comprehensive maintenance and repair of APFC panel by replacement of worn out spare parts and cleaning of the serviceable contactors and tightening/ checking of all internal electrical connections and accessories to maintain PF not less than 0.99 by adjusting/ calibrating the APFC relay of any type, complete all as specified and directed by Engineer-in-Charge. Note:Defective parts if any will be measured and paid separately. |
| 117 | Supply & fixing in replacement of heavy duty gas filled Capacitor 5 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified and directed by Engineer-in-Charge. |
| 118 | Supply & fixing in replacement of heavy duty gas filled Capacitor 10 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified and directed by Engineer-in-Charge. |
| 119 | Supply & fixing in replacement of heavy duty gas filled Capacitor 15 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified and directed by Engineer-in-Charge. |
| 120 | Supply & fixing in replacement of heavy duty gas filled Capacitor 20 KVAR, 440V, 3 phase, 50 Hz, Complete all as specified and directed by Engineer-in-Charge. |
| 121 | Supply & fixing in repair 4 pole power contactor MNX-A1/MCX-13/MCX-22, 50 Hz, Complete all as specified and directed by Engineer-in-Charge.Make : L&T or equivalent |
| 122 | Supply & fixing in repair power Relay MNX - A1,/MNX - A2, 50 Hz, Complete all as specified and directed by Engineer-in-Charge.Make : L&T or equivalent |
| 123 | Material & Labour Cable jointing kit for 1.1 KV grade cable for straight through joint complete with Jointing material (heat shrinkable) and accessories suitable for 3½/ 4 core XLPE armoured Al conductor cable offollowing sizes:- |
| 124 | 25 Sqmm to 50 Sqmm |
| 125 | 70 Sqmm to 150 Sqmm |
| 126 | 185 Sqmm to 300 Sqmm |
| 127 | 400 Sqmm |
| 128 | Taking out UNSV LT UG cables of any sizes from trenches, Complete all as specified and directed by Engineer-in-Charge. |
| 129 | Supply & Laying XLPE insulated, armoured heavy duty electric cable with aluminium conductor, 1100 volts grade of cross-sectional area, complete all as specified and directed by Engineer-in-Charge. Cable of following sizes:- |
| 130 | 16 Sqmm 4 Core |
| 131 | 25 Sqmm 4 Core |
| 132 | 35 Sqmm 3.5 Core |
| 133 | 50 Sqmm 3.5 Core |
| 134 | 95 Sqmm 3.5 Core |
| 135 | 150 Sqmm 3.5 Core |
| 136 | 185 Sqmm 3.5 Core |
| 137 | 400 Sqmm 3.5 Core |
| 138 | Material and Labour for DWC pipe laying in trenches/ under floor/on walls for protection of UG cables, complete with coupler and connected accessories, Including taking down old unserviceable DWC pipe, Complete all as specified and directed by Engineer-in-Charge. Note: Cutting of floor/ road and making good with PCC deemed to be included in itemrate.DWC pipe of following sizes:- |
| 139 | 50/38 mm |
| 140 | 63/50 mm |
| 141 | 90/76 mm |
| 142 | 110/95 mm |