}

Tender For Supply & Erection Of Factory Fabricated & Wired Metal Clad Dust And Vermin Proof Floor Mounting, M.S. Channel Base With Bottom And Top Cable Entries Electrical Control Outdoor Lt Panel With Tpn Mccbs (Four Pole 36 Ka With Thermal Magnetic R, Lucknow-Uttar Pradesh

Irrigation Department has published Tender For Supply & Erection Of Factory Fabricated & Wired Metal Clad Dust And Vermin Proof Floor Mounting, M.S. Channel Base With Bottom And Top Cable Entries Electrical Control Outdoor Lt Panel With Tpn Mccbs (Four Pole 36 Ka With Thermal Magnetic R. Submission Date for this Tender is 30-11-2024. Overhead Line Tenders in Lucknow Uttar Pradesh. Bidders can get complete Tender details and download the document.




Tender Notice

46331519
Tender For Supply & Erection Of Factory Fabricated & Wired Metal Clad Dust And Vermin Proof Floor Mounting, M.S. Channel Base With Bottom And Top Cable Entries Electrical Control Outdoor Lt Panel With Tpn Mccbs (Four Pole 36 Ka With Thermal Magnetic R
Open Tender
Indian
Uttar Pradesh
Lucknow
30-11-2024

Tender Details

Tender For Supply & Erection Of Factory Fabricated & Wired Metal Clad Dust And Vermin Proof Floor Mounting, M.S. Channel Base With Bottom And Top Cable Entries Electrical Control Outdoor Lt Panel With Tpn Mccbs (Four Pole 36 Ka With Thermal Magnetic Release)Switches Complete And Instrument Chamber Etc. Complete In All Respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc.) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium bus bars as per IS8623 or above insulated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with detachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounting of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat B Only. Above assembly is erected on the raised platform upto 45cm height including other civil works ( Foundation, Brickwork and Plaster etc.) A Incoming 800A MCCB- 01 No. Outgoing 630A MCCB 01 No, 250A MCCB 2 Nos, 63A MCCB 1No. Job 01 B Incoming 800A MCCB- 01 No. Outgoing 630A MCCB 01 No, 320A MCCB 1 No, 200A MCCB 1No 63A MCCB 1No. Job 01 C Incoming 400A MCCB- 01 No. Outgoing 200A MCCB 02 Nos, 100A MCCB 1 No, 63A MCCB 1No. Job 01 D Incoming 250A MCCB- 01 No. Outgoing 200A MCCB 02 Nos, 100A MCCB 1 No, 63A MCCB 1No. Job 01 E Incoming 400A MCCB- 01 No. Outgoing 320A MCCB 01 No, 100A MCCB 2Nos, 63A MCCB 1No. Job 01 F Incoming 100A MCCB- 01 No. Outgoning 63A MCCB 02 Nos. Job 01 G Incoming 200A MCCB- 01 No. Outgoing 100A MCCB 01No, 63A MCCB 02 Nos. Job 01 H Incoming 200A MCCB- 01 No. 200A FP Changeover 01 No. Outgoing 100A MCCB 01No, 63A MCCB 04 Nos. Job 01 I Incoming 200A MCCB- 01 No. Outgoing 100A MCCB 01No, 63A MCCB 03 Nos. Job 01 J Incoming 100A MCCB- 01 No. Outgoing 63A MCCB- 02 Nos. Job 01 starter with having contactor, over load relay with voltage based single phase preventor with On/Off/Trip indication lamp and push button digital Ammeter with CTs and selector switch and Auto manual selector switch etc. K Incoming 200A MCCB- 01 No. Outgoing 63A MCCB- 01 No. 01 No. 10 HP Star -Delta starter, 03 Nos. 7.5 HP Star -Delta starter, 02 No. 05 HP DOL starter & 01 No. 03 HP DOL starter with having contactor, over load relay with voltage based single phase preventor with On/Off/Trip indication lamp and push button digital Ammeter with CTs and selector switch and Auto manual selector switch etc. Job 01 L Incoming 100A MCCB- 01 No. Outgoing 63A MCCB- 01 No. 02 Nos. 10 HP Star -Delta starter, 02 Nos. 7.5 HP Star -Delta starter with having contactor, over load relay with voltage based single phase preventor with On/Off/Trip indication lamp and push button digital Ammeter with CTs and selector switch and Auto manual selector switch etc. Job 01 M Incoming 100A MCCB- 01 No. Outgoing 63A MCCB- 01 No. 02 Nos. 10 HP Star -Delta starter, with having contactor, over load relay with voltage based single phase preventor with On/Off/Trip indication lamp and push button digital Ammeter with CTs and selector switch and auto manual selector switch etc. Job 01 N Incoming 100A MCCB- 01 No. Outgoing 63A MCCB- 01 No. 01 Nos. 20 HP Star -Delta starter with having contactor, over load relay with voltage based single phase preventor with On/Off/Trip indication lamp and push button digital Ammeter with CTs and selector switch and Auto manual selector switch etc. Job 01 2 Supply & Erection of factory fabricated & wired metal clad dust and vermin proof floor mounting, M.S. Channel Base with bottom and top cable entries Electrical control Indoor LT panel with TPN MCCBs (Four Pole 36 KA with thermal magnetic release)Switches Complete and instrument chamber etc. Complete in all respects. The instrument chamber shall be separate and shall comprise of flush type digital metering system for phase to phase voltage and single phase voltage, current and other parameters(KVA,P.F,KW etc.) in each phase with touch type selector switches for different readings, instrument fuses, current transformer etc. The panel board shall have suitable capacity electrolytic aluminium bus bars as per IS8623 or above situated with heat shrink sleeving and mounted on non hygroscopic supports such as CMC/BMC support with detachable side covers and shall be suitable for extension on the sides. The MCCBs shall be complete with suitable cable end boxes, compression glands and indicating lamp on incoming etc. The Job includes the grounding of the board as per directions of Engineer-in charge. All out goings of 100 Amp and above shall have an Ammeter. The panel board shall be fabricated with CRCA sheet with a minimum thickness of 1.6mm/2mm. Cubicle type switch board shall be of cat B Only. Above assembly is erected on the raised platform upto 45cm height including other civil works ( Foundation, Brickwork and Plaster etc.) A Incoming 320A MCCB- 01 No. Outgoing 63A MCCB- 02 Nos. 02 Nos. 75 HP Star -Delta starter, 02 Nos. 10 HP Star -Delta starter with having contactor, over load relay with voltage based single phase preventor with On/Off/Trip indication lamp and push button digital Ammeter with CTs and Job 01 selector switch and Auto manual selector switch etc. B Incoming 320A MCCB- 01 No. Outgoing 63A MCCB- 01 No. 01 No. 85 HP Star -Delta starter, 04 Nos. 20 HP Star -Delta starter ,01 No. 10 HP Star -Delta starter with having contactor, over load relay with voltage based single phase preventor with On/Off/Trip indication lamp and push button digital Ammeter with CTs and selector switch and Auto manual selector switch etc. Job 01 C Incoming 200A MCCB- 01 No. Outgoing 63A MCCB- 02 Nos. 02 Nos. 20 HP Star -Delta starter, 01 No. 10 HP Star -Delta starter with having contactor, over load relay with voltage based single phase preventer with On/Off/Trip indication lamp and push button digital Ammeter with CTs and selector switch and Auto manual selector switch etc. Job 01 D Incoming 100A MCCB- 01 No. Outgoing 63A MCCB- 01 No. 02 Nos. 10 HP Star -Delta starter with having contactor, over load relay with voltage based single phase preventer with On/Off/Trip indication lamp and push button digital Ammeter with CTs and selector switch and Auto manual selector switch etc. Job 01 E Transformer Incoming 1250A MOD ACB- 01 No. DG 01 Incoming 800A MOD ACB- 01 No. DG 02 Incoming 800A MOD ACB- 01 No. Bus-coupler 800A MOD ACB 01 No. Outgoing 800A MOD ACB 2 Nos Job 01 3 Supply ,Installation, testing & commissioning Indoor type 11 KV HT VCB Panel for 630 kva transformer (incoming cum outgoing) board having 800A TP VCB of 18.4 kA rupturing capacity, fabrication with 2 mm thick CRCA sheet. Totally enclosed, air insulated, metal clad housing, floor mounting, horizontal isolation and painting with seven tank process complete in all respects as required.

Key Value

Document Fees
Refer document
EMD
Refer document
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail