| 1 | Removing interlock paver blocks in floors andlaid in cement mortar including refixing of interlocking paver blocks. For thickness of tiles above 25 mm and up to 60 mm as directed by the Engineer-In-Charge. |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 3 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level :1:5:10 (1 Cement : 5 coarse sand (zone-III) derived from natural sources : 10 graded stone aggregate 40 mm nominal size derived from natural sources) |
| 4 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:2:4 (1 cement : 2 coarse sand (zone-III) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Providing and fixing \"J\" bolts including nuts and washers complete. |
| 6 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc., including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 7 | Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture. |
| 8 | Painting runway/taxi track/apron marking with adequate nos of coats to give uniform finish with road marking paint of superior make as approved by the Engineer-in-charge, i/c cleaning the surface of ail dirt, scales, oil, grease and other foreign material etc. and lining out complete.New work (Two or more coats) |
| 9 | Providing and fixing/erecting the Tensile membrane fabric of Ferrari make PVDF coated 750 GSM Polyster fabric with PVDF top coat similar to \"PRECONTRAINT 702 S2\" as roof Covering to the existing framework of Canopy, Arches, sheds etc., to the shape and geometry as approved by the Engineer-in-charge including cutting the membrane seaming, errection tensioning with chain pulley and clamping to the base structure with all contractor\"s materials men, transportation all lead and lift, taxes etc., as per the specification and as directed by the Engineer-in-charge. Specification to the Tensile membrane fabric:- Polyster fabric with PVDF (polyvinyl indene flouride) top coat 240 microns thick yarn, 1100 dtx PES HT weight 750 gm/Sg. Mconfirming to EN ISO 2286-2Tensile strength : (Warp/weft) 280/280 daN/5 Cm confirming to EN53.363 Adhesion 10/10 daN/5cm confirming to (Warp/Weft) EN ISO 2411 Surface Treatment: Formula weldable Fluorinated varnish Light Transmission : 13.5% confirming to NFP 38 511 Flame retardancy : M2/NFP 92-507,CSFM T19B1/DIN 4102-1. Including all necessary screws fittings etc., complete as directed by the Engineer-In-Charge. |
| 10 | Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 volts, on surface/ recess,complete with tinned copper bus bar, neutral bus bar, earth bar,din bar, interconnections, powder painted including earthing etc.as required.(But without MCB/RCCB /Isolator).12 Way, Double door |
| 11 | Supplying and fixing TP sheet steel enclosure on surface/ recess along with 16/25/32 A 415 V \"C\" curve TP MCB complete with connections, testing and commissioning etc. as required. |
| 12 | S/F \"C\" series MCB: Supplying and fixing 5 amps to 32 amps rating, 240/415 volts,\"C\" curve, miniature circuit breaker suitable for inductive load offollowing poles in the existing MCB DB complete withconnections, testing and commissioning etc. as required. Make:Legrand |
| 13 | (i)Single pole |
| 14 | (ii)Double pole |
| 15 | Supply offollowing aluminium armoured XLPE insulated under ground cable as per IS standards etc., as required and as directed by the engineer in charge. Make : Havells/ Gloster /Finolex4x16Sq.mm |
| 16 | Supplying and making indoor end termination with brass compression gland and aluminium lugs for following size of PVCinsulated and PVC sheathed / XLPE aluminium conductor cableof 1.1 KV grade as required.4 X 16 sq. mm (28mm) |
| 17 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required.Upto 35 sq. mm |
| 18 | Supply of 1 x 22wattsLED Tube fittingsfixture with tube and complete set consisting all accessories etc., as required Type:TMC501PXT-LED22WP3241. Make:Philips |
| 19 | Supply of out door IP66 Flood LightLED Luminaire of 70 Wattwith all required accessoriesandcomplete and as directed by the engineer incharge. Make:Crompton/ Philips |
| 20 | Installation, testing and commissioning of pre-wired, fluorescentfitting / LED Fittings compact fluorescent fitting/LED Fittingsof all types, complete with all accessories and tube etc. directly on ceiling/ wall, including connection with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 21 | Wiring in existing conduit: Supplying and drawing following sizes of FRLS PVC insulated copper conductor single core cable in the existing surface/recessed steel/PVC condit/PVC Casing and Caping as required. Make: Please refer List of Approved makes |
| 22 | (i)3 x 1.5 sq.mm |
| 23 | (ii)3 x 2.5 sq.mm |
| 24 | S/F Modular boxes, base & cover plate: Supplying and fixing of following size/modules, GI/PVC box along with modular base & cover plate for modular switches in recess etc., as required Make: Please refer List of Approved makes6 module |
| 25 | S/F Modular type switch / socket / fan regulator / call bell: Supplying and fixing of following modular switch/socket on the existing modular plate & switch box including connections but excluding modular plate etc., as required Make:Please refer List of Approved makes |
| 26 | (i)5/6A One way Switch |
| 27 | (ii)3pin 5/6A power socket outlet |
| 28 | (iii)15/16A One way Switch |
| 29 | (iv)6pin 16A/6A power socket outlet |
| 30 | S/F PVC Conduit: Supplying and fixing of following sizes of PVC conduit along with accessories in surface/recess cutting the wall and making good the same in case of recessed conduitas required.(Make:Sudhakar)25mm |
| 31 | Supplying and fixing 3 pin, 5 A ceiling rose on the existing junction box/ wooden block including connections etc. as required. |
| 32 | Supply of Astronomical Timer for Street light control |