| 1 | Supply, Installation and Commissioning of MRL Lift as per following Specification : |
| 2 | TECHNICAL SPECIFICATION :- THREE PHASEMRL |
| 3 | Quantity:One (01) |
| 4 | Type: 08(Eight) Passengers |
| 5 | Load : 544 kgs |
| 6 | Speed :1.0Mts /Sec |
| 7 | Control:Microprocessor with V3F Drive |
| 8 | Car Travel :Ground to 1st to 2nd to 3rdFloor |
| 9 | Floor rise (about) :9.00 Meters |
| 10 | No. of Opening :4 (Four) |
| 11 | No. of Stops:4 (Four) |
| 12 | Operations:Simplex CollectiveSelective Control |
| 13 | Landing Entrance :Stainless Steel Automatic Telescopic Door withSmall Vision Panel |
| 14 | Car Enclosure :Stainless Steel Cabin( Hairline Finished) |
| 15 | Car Entrance Door :Stainless Steel Automatic Telescopic Door with Small Vision Panel |
| 16 | Car Flooring:Vinyl Flooring |
| 17 | Clear Door Opening:(about)800 mm wide2000mm high |
| 18 | # Lift Well (Inside):(about)1800mm wide *1550mm deep |
| 19 | Door Operation :Automatic |
| 20 | Car Inside:(about)1200 mm wide *1200 mm deep |
| 21 | Reduction Gear:As Per Std. MRL Application Design |
| 22 | Motor :3 Phase Lift Duty Motor |
| 23 | Power Supply :415 volts, 3 Phase, 50 Hz. A.C./220 V, 1 Phase 50 Hz. A.C. |
| 24 | Wire – Ropes:UshaMartin Ropes |
| 25 | Installation:Indoor |
| 26 | Overhead :4500 |
| 27 | Pit :1600mm |
| 28 | Construction of Lift well:RCC |
| 29 | Load Bearing Position :Left &Right |
| 30 | Machine Room Sizes :NA |
| 31 | MAIN FEATURES: - |
| 32 | (i) Emergency Alarm bell Switch in Cabin : YES |
| 33 | (ii) Emergency Light Display in Cabin: YES |
| 34 | (iii) Call Buttons with Floor Position Indicatorin Cabin and all Landings: YES |
| 35 | (iv) Emergency Stop Switch, Fan / Light Switch ,Auto/ Attendant Switchin Cabin :YES |
| 36 | (v) Door Open Bell in Cabin in case of MCD :NO |
| 37 | (vi) Auto On/ Off (Energy Savings) Fan & Light:YES |
| 38 | (vii) Auto Door Open / Closing Button: YES |
| 39 | SAFETY FEATURES:- |
| 40 | (i) Over Speed Protection by OSG:YES |
| 41 | (ii) Motor Overload Protection :YES |
| 42 | (iii) Single Phase Protection: YES |
| 43 | (iv) Phase Failure Protection:YES |
| 44 | (v) Terminal Limit Switch in Pit and Overhead:YES |
| 45 | (vi) Door Electrical and Mechanical Interlocking Switches: YES |
| 46 | (vii) Fireman’s Switch at Main Lobby : YES |
| 47 | OPTIONAL FEATURES:- |
| 48 | (i) ARD System :YES |
| 49 | (iI) Voice Announcement System: YES |
| 50 | # Lift Well – Changes in well sizes if therein, will be incorporated in layout drawing.Car size may get changed according to the feasibility, to match with our design. |