Tender for 33Kv Link Line Between Chithera Kot S/S Replacement 05 Nos St 13 Mtr Pole Work Lt Lines Strengthening Works - 33KV Link Line between Chithera & Kot S/S Replacement 05 Nos ST 13 Mtr Pole Work & LT Lines Strengthening works 2 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 3 to 15 3 ST POLE 11MTR 4 STONE PAD 5 33KV CROSS ARM 6 33KV PIN INSULATOR 7 33 KD DISC INSULATOR 8 33 KV TPMO SET 9 33KV CONTROL PANEL I/C 10 33KV CT STRUCTURE WITH CT 200/1A 11 33KV CIRCUIT BREAKER WITH STRUCTURE 12 CONTROL CABLE 4X2.5SQMM 13 EARTHING COMPLETE 14 STAY SET COMPLETE WITH CONCRETING 15 DOG CONDUCTOR 16 Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO. 17 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)ST POLE 11MTR 18 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, F bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required.Single Pole(a) ST POLE 11 MTR AND PCC POLE 8.5MTR 19 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a)ST POLE 11 MTR AND PCC POLE 8.5MTR 20 FIXING OF PIN INSULATOR WITH PIN, COMPLETE WORK IN ALL RESPECT. 21 FIXING OF CROSS ARM AS PER SITE REQUIREMENT. 22 FIXING OF STONE PAD AS PER SITE REQUIREMENT. 23 FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT. 24 INSTALLATION AND COMMISSIONING OF 33KV TPMO WITH STRUCTUREWITH MAKING OF FOUNDATION AND PLINTH AT SITE AND COMPLETE CONNECTIONS IN ALL RESPECT. 25 INSTALLATION AND COMMISSIONING OF 33KV I/C CONTROL PANEL WITH MAKING OF FOUNDATION AND PLINTH AT SITE AND PROPER CONNECTIONS IN ALL RESPECT. 26 INSTALLATION AND COMMISSIONING OF 33KV CT 200/1AMP WITH STRUCTURE WITH MAKING OF FOUNDATION AND PLINTH AT SITE AND PROPER CONNECTIONS IN ALL RESPECT. 27 INSTALLATION AND COMMISSIONING OF33KV CIRCUIT BREAKER WITH STRUCTURE WITH MAKING OF FOUNDATION AND PLINTH AT SITE AND PROPER CONNECTIONS IN ALL RESPECT. 28 FIXING AND CONNECTION BY CONTROL CABLE 4X2.5SQMM AS PER SITE REQUIREMENT WITH COMPLETE WORK IN ALL RESPECT. 29 Driving of MSearth rod of size20x2500 mm in earth andjointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballastin ration 1:4:8 in Block 600*600*300 mm with binding & nuzzlingincluding providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor) 30 Fixing, tightening & nozzling of stay set with wire and stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps and Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc. 31 Laying, spreading, lifting and final sagging of 3 OR 4phases ACSR Dog conductor in accordance with Line chart includidng binding and fixing of all accessories in 03Nos OR 04 Nos. Conductor in parallel as per site requirement. 32 PROVIDING AND FIXING OF COPPER BUS BAR FOR 10MVA POWER AT S/S CHITHERA WITH COMPLETE WORK IN ALL RESPECT. 33 PROVIDING AND FIXING OF HOLDING CLAMP AS PER REQUIREMENT. 34 PROVIDING AND FIXING OFPG CLAMP AS PER REQUIREMENT 35 PROVIDING AND FIXING OFNUT BOLT AND WASHERS AS PER REQUIREMENT 36 PROVIDING AND FIXING OFPG CLAMP (DOG TO DOG) AS PER REQUIREMENT 37 PROVIDING AND FIXING OFF BRACKETAS PER REQUIREMENT 38 MAINTENANCE, STRENGHTING WORKS AND PROPER SAGGING OF LT LINE OF CHITHERA & KOT. 39 Removal and Dismentaling of old and used Conductor from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends. 40 Removal and Dismentaling of old and Damaged ST Pole from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends. 41 Removal and Dismentaling of old and Damaged Cross Arm from the site and safe carriage of its from the site to any store of PVVNL DISCOM including loading and un-loading both ends. 42 11 kv industrial feeder emanting from 33/11KV Chithera S/S Replacement of 350 mtr LT line Bare conductor to ABC Cable3x50sqmm 43 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 44 TO 52 44 PCC POLE 8.5MTR 45 STONE PAD 46 STAY SET WITH CONRETING 47 DISTRIBUTION BOX 48 LT ABC 1X35SQMM 49 EARTHING COMPLETE 50 LT ABC 3X50SQMM 51 LT ABC 3X95SQMM 52 LT ABC 3X120SQMM 53 Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO. 54 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)PCC POLE 8.5MTR 55 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, F bracket 75x10mm, G.I.Nut bolt & washer, Stone Pad Al. Binding wire and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as an fabrication work if required.Single Pole(a) ST POLE 11 MTR AND PCC POLE 8.5MTR 56 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a)ST POLE 11 MTR AND PCC POLE 8.5MTR 57 FIXING OF 11KV STONE PAD AS PER SITE REQUIREMENT. 58 Fixing, tightening & nozzling of stay set with wire and stay rod with the poles of required tension as per drawing, including providing & fixing of Stay Insulators of 11KV and Stay Clamps and Grouting of stay rods (20x1800)mm including all work of excavation, cement concrete in size (0.60x0.60x0.30)m in ratio 1:3:6 cement, sand, 20mm Stone grift) as per drg. Including back filling of soil and proper ramming etc. 59 INSTALLATION AND FIXING OF DISTRIBUTION BOX AT POLE WITH PROPER CONNECTION AND LOCK AND COMPLETE WORK IN ALL RESPECT. 60 Driving of MSearth rod of size20x2500 mm in earth andjointing through G.I. wire of 6 SWG between support and earth electrode by providing proper size of bolts and nuts for pole earthing. Supply Erection, fixing, grouting of stay rod in cement, sand and brick ballastin ration 1:4:8 in Block 600*600*300 mm with binding & nuzzlingincluding providing & fixing of stay insulator complete in all respect with grouting. (All Work and Material in the scope of Contractor) 61 Laying, Sagging, connecting, Re-sagging of LT ABC 1X35Sq.mm Cable WITH making connection complete at both ends as per site requirement. 62 Laying, Sagging, connecting, Re-sagging of LT ABC 1X50Sq.mm Cable WITH making connection complete at both ends as per site requirement. 63 Laying, Sagging, connecting, Re-sagging of LT ABC 1X95Sq.mm Cable WITH making connection complete at both ends as per site requirement. 64 Laying, Sagging, connecting, Re-sagging of LT ABC 1X120Sq.mm Cable WITH making connection complete at both ends as per site requirement. 65 PROVIDING AND FIXING OF HOLDING CLAMP AS PER REQUIREMENT. 66 PROVIDING AND FIXING OFNUT BOLT AND WASHERS AS PER REQUIREMENT 67 PROVIDING AND FIXING OFPEARCING CLAMP AS PER REQUIREMENT 68 PROVIDING AND FIXING OFSUSPENSION CLAMP AS PER REQUIREMENT 69 PROVIDING AND FIXING OFALU. LUG 35SQMM AS PER REQUIREMENT