Work related to construction of 06 No. 11/0.400 kV new substations in the area of Electricity Urban Distribution Section III. - Provision of New 250 KVA T/f NEAR E-363 SEC-15, Noida in the area of Substation SECTOR-16 Noida under EUDSD-XI, Noida 2 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 3 to 14 3 8.5 Mtr Long PCC Pole 4 MS Channel (Dropper) 100x50x2028 mm 5 ACSR Weasle Conductor 6 Cable LT ABC 3x120+1x95+1x16 Sqmm 7 MS Top Channel (125x65x2240 mm) 8 11 KV Disc Insulator T&C type 45 KN 9 11 KV Disc Fitting 10 MS Chanel 125x65x1300 mm ( T-Off) 11 11 KV Poly Pin Insulator 12 11/0.4 KV T/f 250 KVA 13 11 KV Fuse Set 14 LT PVC Cable Al 1x400 Sqmm 15 Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO. 16 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)PCC POLE 8.5MTR 17 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a) PCC POLE 8.5MTR 18 FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT. 19 FIXING OFMS TOP CHANNEL COMPLETE WORK IN ALL RESPECT. 20 FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT. 21 FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT. 22 FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT. 23 FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT. 24 CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT. 25 Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connectionswith complete work in all respects. 26 Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement. 27 Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement. 28 Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO. 29 Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect. 30 Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement. 31 Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement. 32 Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement. 33 Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL 34 Fabrication of Plinth/Chair for 250KVA T/F as per site requirement. 35 Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement. 36 Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mmterminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer. 37 Provision of New 250 KVA T/f NEAR D-12, SEC-15 under Substation SECTOR-16 Noida under EUDSD-XI, Noida 38 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 39 to 50 39 8.5 Mtr Long PCC Pole 40 MS Channel (Dropper) 100x50x2028 mm 41 ACSR Weasle Conductor 42 Cable LT ABC 3x120+1x95+1x16 Sqmm 43 MS Top Channel (125x65x2240 mm) 44 11 KV Disc Insulator T&C type 45 KN 45 11 KV Disc Fitting 46 MS Chanel 125x65x1300 mm ( T-Off) 47 11 KV Poly Pin Insulator 48 11/0.4 KV T/f 250 KVA 49 11 KV Fuse Set 50 LT PVC Cable Al 1x400 Sqmm 51 Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO. 52 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)PCC POLE 8.5MTR 53 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a) PCC POLE 8.5MTR 54 FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT. 55 FIXING OFMS TOP CHANNEL COMPLETE WORK IN ALL RESPECT. 56 FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT. 57 FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT. 58 FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT. 59 FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT. 60 CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT. 61 Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connectionswith complete work in all respects. 62 Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement. 63 Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement. 64 Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO. 65 Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect. 66 Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement. 67 Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement. 68 Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement. 69 Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL 70 Fabrication of Plinth/Chair for 250KVA T/F as per site requirement. 71 Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement. 72 Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mmterminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer. 73 New 250 KVA T/f Near SBI, Sector-2, Under 33/11 KV S/s, Sector-16, Noida under EUDSD-XI, Noida 74 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 75 to 86 75 8.5 Mtr Long PCC Pole 76 MS Channel (Dropper) 100x50x2028 mm 77 ACSR Weasle Conductor 78 Cable LT ABC 3x120+1x95+1x16 Sqmm 79 MS Top Channel (125x65x2240 mm) 80 11 KV Disc Insulator T&C type 45 KN 81 11 KV Disc Fitting 82 MS Chanel 125x65x1300 mm ( T-Off) 83 11 KV Poly Pin Insulator 84 11/0.4 KV T/f 250 KVA 85 11 KV Fuse Set 86 LT PVC Cable Al 1x400 Sqmm 87 Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO. 88 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)PCC POLE 8.5MTR 89 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a) PCC POLE 8.5MTR 90 FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT. 91 FIXING OFMS TOP CHANNEL COMPLETE WORK IN ALL RESPECT. 92 FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT. 93 FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT. 94 FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT. 95 FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT. 96 CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT. 97 Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connectionswith complete work in all respects. 98 Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement. 99 Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement. 100 Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO. 101 Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect. 102 Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement. 103 Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement. 104 Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement. 105 Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL 106 Fabrication of Plinth/Chair for 250KVA T/F as per site requirement. 107 Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement. 108 Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mmterminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer. 109 Provision of New 250 KVA T/f Near B-145, Sector-15, Noida, Under 33/11 KV S/s, Sector-16, Noida under EUDSD-XI, Noida 110 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 111 to 122 111 8.5 Mtr Long PCC Pole 112 MS Channel (Dropper) 100x50x2028 mm 113 ACSR Weasle Conductor 114 Cable LT ABC 3x120+1x95+1x16 Sqmm 115 MS Top Channel (125x65x2240 mm) 116 11 KV Disc Insulator T&C type 45 KN 117 11 KV Disc Fitting 118 MS Chanel 125x65x1300 mm ( T-Off) 119 11 KV Poly Pin Insulator 120 11/0.4 KV T/f 250 KVA 121 11 KV Fuse Set 122 LT PVC Cable Al 1x400 Sqmm 123 Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO. 124 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)PCC POLE 8.5MTR 125 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a) PCC POLE 8.5MTR 126 FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT. 127 FIXING OFMS TOP CHANNEL COMPLETE WORK IN ALL RESPECT. 128 FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT. 129 FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT. 130 FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT. 131 FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT. 132 CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT. 133 Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connectionswith complete work in all respects. 134 Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement. 135 Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement. 136 Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO. 137 Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect. 138 Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement. 139 Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement. 140 Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement. 141 Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL 142 Fabrication of Plinth/Chair for 250KVA T/F as per site requirement. 143 Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement. 144 Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mmterminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer. 145 Provision of New 250 KVA T/f Near A-20, Sector-16, Noida, Under 33/11 KV S/s, Sector-16, Noida under EUDSD-XI, Noida 146 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 147 to 158 147 8.5 Mtr Long PCC Pole 148 MS Channel (Dropper) 100x50x2028 mm 149 ACSR Weasle Conductor 150 Cable LT ABC 3x120+1x95+1x16 Sqmm 151 MS Top Channel (125x65x2240 mm) 152 11 KV Disc Insulator T&C type 45 KN 153 11 KV Disc Fitting 154 MS Chanel 125x65x1300 mm ( T-Off) 155 11 KV Poly Pin Insulator 156 11/0.4 KV T/f 250 KVA 157 11 KV Fuse Set 158 LT PVC Cable Al 1x400 Sqmm 159 Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO. 160 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)PCC POLE 8.5MTR 161 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a) PCC POLE 8.5MTR 162 FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT. 163 FIXING OFMS TOP CHANNEL COMPLETE WORK IN ALL RESPECT. 164 FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT. 165 FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT. 166 FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT. 167 FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT. 168 CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT. 169 Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connectionswith complete work in all respects. 170 Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement. 171 Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement. 172 Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO. 173 Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect. 174 Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement. 175 Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement. 176 Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement. 177 Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL 178 Fabrication of Plinth/Chair for 250KVA T/F as per site requirement. 179 Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement. 180 Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mmterminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer. 181 Provision of New 250 KVA T/f Near A-1D, Sector-16, Noida Under 33/11 KV S/s, Sector-16, Noida under EUDSD-XI, Noida 182 Safe carriage of following stock material, from any of the Store Center of PVVNL to work siteincluding Loading from Store and safe unloading at site for Item No. 183 to 18 183 8.5 Mtr Long PCC Pole 184 MS Channel (Dropper) 100x50x2028 mm 185 ACSR Weasle Conductor 186 Cable LT ABC 3x120+1x95+1x16 Sqmm 187 MS Top Channel (125x65x2240 mm) 188 11 KV Disc Insulator T&C type 45 KN 189 11 KV Disc Fitting 190 MS Chanel 125x65x1300 mm ( T-Off) 191 11 KV Poly Pin Insulator 192 11/0.4 KV T/f 250 KVA 193 11 KV Fuse Set 194 LT PVC Cable Al 1x400 Sqmm 195 Errection of above Following material and Supply and errection of the DE-CENTRALISED material for completing the works as per RESPO. 196 The excavation of foundation pit in mix soil/normal soil/soft soil & hard rock as per site condition and its back filling and leveling etc. The size of the pit will be (750x450)mm and having depth of 1/6th of the full length of the support. Erection of support, complete with providing & fixing of all G.I.Clamps size of 75x10mm, 65x8mm, G.I.Nut bolt & washer, P.G.Clamp, Stone Pad, Al. Binding wire, E bracket 75x10mm, and other accessories as per drawing. The work includes carriage and handling of supports from sectional store to pit site as well as any fabrication work if required & fixing of cross bracing sets 4.3mtr long, from G.I.Angle 65x65x6mm. The work includes cutting holes and providing G.I.Bolt of 16x40mm size, in the middle of the cross bracing with 01No. spring washer of proper size as per drawing/ as per schedule.Double Pole Structures(a)PCC POLE 8.5MTR 197 Grouting of supports in CC 1:3:6 (Cement, sand & 20mm stone grift). Grouting will be done in the block of size (450x450)mm x1/6th of full length of the support, upto ground level, 300mm plinth above the ground level with C.C. 1:3:6 (Cement, Course sand and Stone grift) with muffing as per RESPO. Work includes back filling and proper ramming.Single Pole and Double Pole(a) PCC POLE 8.5MTR 198 FIXING OF MS CHANNEL (DROPPER) 100X50X2028 COMPLETE WORK IN ALL RESPECT. 199 FIXING OFMS TOP CHANNEL COMPLETE WORK IN ALL RESPECT. 200 FIXING OF DISC INSULATOR WITH FITTINGS AS PER SITE REQUIREMENT. 201 FIXING OF T-OFF CHANNEL AS PER SITE REQUIREMENT. 202 FIXING OF PIN INSULATOR WITH PIN AS PER SITE REQUIREMENT. 203 FIXING OF 11KV FUSE SET AS PER SITE REQUIREMENT. 204 CONNECTING OF LT PVC CABLE ALU. 1X400SQMM AS PER SITE REQUIREMENT. 205 Installation and Commissioning of 11/0.4 KV, 250 KVA T/F Mounted on Plinth as per site requirement and providing & fixing of Lugs & copper L-piece (04 No.) of size 400x50x6mm and making of L.T.Connectionswith complete work in all respects. 206 Laying, Sagging and Re-Sagging of AB Cable 3x120sqmm at different locations of T/F as per site requirement. 207 Laying, Sagging and Re-Sagging of Weasel Conductor as per site requirement. 208 Providing and Fixing of J HOOK FOR CABLE HANGING AS PER RESPO. 209 Providing and Fixing of Clamp with Nut Bolt and Washer with complete work in all respect. 210 Providing and Fixing of Clamp for 3Phase Distribution Box as per site requirement. 211 Providing and Fixing of Pad Lock for 3Phase Distribution Box as per site requirement. 212 Providing and Fixing of Clamp of LT (T-off) with nut & bolts as per site requirement. 213 Providing, Installation and Commissioning of LT ACB 400Amp. As per GTP approved of PVVNL 214 Fabrication of Plinth/Chair for 250KVA T/F as per site requirement. 215 Fabrication of Wiremes Fencing for 250KVA T/F as per site requirement. 216 Chemical Earthing of BODY AND NEUTRAL OF DISTRIBUTION T/F : Providing of earth elctrode strip in pipe terminal type chemical earthing proper hot deep galvanization dia 50 mm length 3 mtr down conductor size - 32mm x 6mmterminal connection hole dia 8mm The cavity between the strip & pipes is filled with condutive mixture - for hermetically filling inside the cavity i.e. between secondary conductor & primary conductor, crystline compound is to be injected in the electrode assembly. It is a combination of high conductivity metal alloys, copper & aluminum power, conductive carbon / cement and bonding material etc the electrode should be sealed from both the ends. The outer pipe of the elctrode should be zinc coated the characteristics of this compound is highly cnductive, non magnetic & non corrosive in G.I. Including providing of Pgs backfill compound each elctrode should be supplied with bags of 25 kg x 2 bfc compound (ground resistance enhancement powder 50 kgs each CPRI tested to connect the above chemical earthing with the GI strip of size 32 mm x 6 mm suitable for distribution transformer.