Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #46276293

Tender For Equipment

Issued by Boards / Undertakings / PSU · coimbatore, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
04 Dec 2024
0 days left
EMD
28000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
coimbatore → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Equipment , Total Organic Carbon(Toc) Analyser , Flow Injection Toc (With Tnb) Analyzer: Measurement Parameters: Direct Determination Of Tc, Tic, Toc, Npoc, Npoc Plus, Toc In Liquids And Solids And Tnb With Software For Control And Evaluation And Total Nitrogen Estimation By Maintenance Free Chemodetector (Chd)(For Detecting 50 Ppb Or Above); Digestion Mode: Catalytic High Temperature Combustion Of Up To 950°Cor Better;Measurement Range: 0-30,000 Mg/L Or Better; Detection Limit: 4 ?G/L C Or Better; Reproducibility : Cv 1–2%; Measurement Time: Approximately 3-5 Min For Each Parameter; Sample Injection: Automatic Flow Injection With Intelligent Rinsing; Injection Volume: 100–1,000?L Variable Or Better; Particle Handling : 0.7 ?M Or Better; With Automatic Leak Check: Automatic Or Manual Data Export In Different Formats (Lims, Csv, Pdf);Ambient Operating Temperature: 10 °C - 35 °C; Humidity: 5 - 90; Multi-Point Calibration From A Single Standard;Up To 3 Calibration Ranges Each Parameter And Method Can Be Usedwithtoc-Blank Determination And Automatic Result Correction; Self-Check-System-Automatic Monitoring Of Maintenance Intervals, Gas Flows And Pressures, Temperatures And Detector Status;Solids Combustion Module For Solid Samples For Tc/Toc Analysis: High Temperature Combustion Furnace For The Analysis Of Carbon (Tc/Toc) In Solid Samples; Furnace Temperature:1300 Deg C Or Better; Autosampler: Autosampler For Up To 20 Samples Or Better With Sample Vials Of 50 Ml Capacity; Sample Homogenization By Integrated Magnetic Stirrer; Installation Start-Up Package: Final Inspection + Quality Certificate, User Manual Including Trouble Shooting; Consumable Start-Up Kit; Combustion Tube, Catalyst For One Filling; Quartz Wool, Quartz Chips,Required Mats Etc; Required Essential Accessories: A Suitable Pc With Minimum I5 Configuration Or Better; Gas Cylinder – 2 Numbers Of Oxygen Cylinder (99.5% Purity); Suitable Brassregulators; Consumables For 2 Years Of Operation For Both Liquid And Solid Samples For Toc And Tnb Estimation; Required Ups For The Entire Pc Unit. Warranty: 2 Year Warranty For The Full System; Minimum 5-Year Warranty Or Better For Ndir Detector And Furnace Unit From The Date Of Installation, Should Be Provided Only By Oem (Original Equipment Manufacturer). The Quoted Price Should Include All The Above Things As Per The Technical Specification Given And The Same Should Be Supplied To Our Lab In Bharathiar University, Coimbatore, Tamilnadu.

BOQ

Name of Work: Total Organic Carbon(TOC) Analyser
Sl. No. Item Description
1Total Organic Carbon(TOC) Analyser
2Flow injection TOC (with TNb) analyzer: Measurement parameters: Direct determination of TC, TIC, TOC, NPOC, NPOC plus, TOC in liquids and Solids and TNb with software for control and evaluation and Total Nitrogen estimation by maintenance free Chemodetector (ChD)(for detecting 50 ppb or above); Digestion mode: Catalytic high temperature combustion of up to 950°Cor better;Measurement Range: 0-30,000 mg/L or better; Detection limit: 4 µg/L C or better; Reproducibility : CV 1–2%; Measurement time: Approximately 3-5 min for each parameter; Sample injection: Automatic flow injection with intelligent rinsing; Injection volume: 100–1,000µL variable or better; Particle handling : 0.7 µm or better; With Automatic leak check: Automatic or manual data export in different formats (LIMS, CSV, PDF);Ambient operating temperature: 10 °C - 35 °C; Humidity: 5 - 90; Multi-point calibration from a single standard;Up to 3 calibration ranges each parameter and method can be usedwithTOC-Blank determination and automatic result correction; Self-Check-System-Automatic monitoring of maintenance intervals, gas flows and pressures, temperatures and detector status;Solids combustion module for solid samples for TC/TOC analysis: High temperature combustion furnace for the analysis of carbon (TC/TOC) in solid samples; Furnace Temperature:1300 deg C or better; Autosampler: Autosampler for up to 20 samples or better with sample vials of 50 mL capacity; Sample homogenization by integrated magnetic stirrer; Installation start-up package: Final inspection + quality certificate, User manual including Trouble shooting; Consumable start-up kit; Combustion tube, Catalyst for one filling; Quartz wool, quartz chips,required mats etc; Required Essential Accessories: A suitable PC with minimum i5 configuration or better; Gas cylinder – 2 numbers of Oxygen cylinder (99.5% purity); Suitable BRASSregulators; Consumables for 2 years of operation for both liquid and solid samples for TOC and TNb estimation; Required UPS for the entire PC unit. Warranty: 2 Year warranty for the full system; Minimum 5-year warranty or better for NDIR detector and furnace unit from the date of installation, should be provided only by OEM (Original Equipment manufacturer). The quoted price should include all the above things as per the technical specification given and the same should be supplied to our lab in Bharathiar University, Coimbatore, Tamilnadu.

AI Tender Summary

OUR REF NO 46276293
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 04-12-2024
Authority
Authority Name Higher Education Commission
Work Description Equipment , Total Organic Carbon(Toc) Analyser , Flow Injection Toc (With Tnb) Analyzer: Measurement Parameters: Direct Determination Of Tc, Tic, Toc, Npoc, Npoc Plus, Toc In Liquids And Solids And Tnb With Software For Control And Evaluation And Total Nitrogen Estimation By Maintenance Free Chemodetector (Chd)(For Detecting 50 Ppb Or Above); Digestion Mode: Catalytic High Temperature Combustion Of Up To 950°Cor Better;Measurement Range: 0-30,000 Mg/L Or Better; Detection Limit: 4 ?G/L C Or Better; Reproducibility : Cv 1–2%; Measurement Time: Approximately 3-5 Min For Each Parameter; Sample Injection: Automatic Flow Injection With Intelligent Rinsing; Injection Volume: 100–1,000?L Variable Or Better; Particle Handling : 0.7 ?M Or Better; With Automatic Leak Check: Automatic Or Manual Data Export In Different Formats (Lims, Csv, Pdf);Ambient Operating Temperature: 10 °C - 35 °C; Humidity: 5 - 90; Multi-Point Calibration From A Single Standard;Up To 3 Calibration Ranges Each Parameter And Method Can Be Usedwithtoc-Blank Determination And Automatic Result Correction; Self-Check-System-Automatic Monitoring Of Maintenance Intervals, Gas Flows And Pressures, Temperatures And Detector Status;Solids Combustion Module For Solid Samples For Tc/Toc Analysis: High Temperature Combustion Furnace For The Analysis Of Carbon (Tc/Toc) In Solid Samples; Furnace Temperature:1300 Deg C Or Better; Autosampler: Autosampler For Up To 20 Samples Or Better With Sample Vials Of 50 Ml Capacity; Sample Homogenization By Integrated Magnetic Stirrer; Installation Start-Up Package: Final Inspection + Quality Certificate, User Manual Including Trouble Shooting; Consumable Start-Up Kit; Combustion Tube, Catalyst For One Filling; Quartz Wool, Quartz Chips,Required Mats Etc; Required Essential Accessories: A Suitable Pc With Minimum I5 Configuration Or Better; Gas Cylinder – 2 Numbers Of Oxygen Cylinder (99.5% Purity); Suitable Brassregulators; Consumables For 2 Years Of Operation For Both Liquid And Solid Samples For Toc And Tnb Estimation; Required Ups For The Entire Pc Unit. Warranty: 2 Year Warranty For The Full System; Minimum 5-Year Warranty Or Better For Ndir Detector And Furnace Unit From The Date Of Installation, Should Be Provided Only By Oem (Original Equipment Manufacturer). The Quoted Price Should Include All The Above Things As Per The Technical Specification Given And The Same Should Be Supplied To Our Lab In Bharathiar University, Coimbatore, Tamilnadu.
Basic Detail
Tender No C7/CRTD/EVS/DST-SERB/2306/3726
Bidding Type Tender
Location
City coimbatore
State Tamil Nadu
Key Dates
Publish Date 20 Nov 2024
Submission Date 04 Dec 2024
Open Date 05 Dec 2024
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 28000
Exemption Available
Document List
9e18ddce-0818-4f39-b09f-c063aecd69be.html
BOQ_598026.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 04, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 05, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

9e18ddce-0818-4f39-b09f-c063aecd69be.html

xls

BOQ_598026.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders