Power Boards / Undertakings / PSU Closing in 0 days TDR #46273191

Tender For Installation Of Additional 05 Mva Power Transformer At 33/11 Kv S/S Rajajipuram Old From Increasing Capacity From 3X10 Mvato 3X10+1X5 Mva. & Installation Of Additional 05 Mva Power Transformer At 33/11 Kv S/S Rdso From Increasing Capacity From

Issued by Boards / Undertakings / PSU · rajajipuram, Uttar Pradesh
Tender Value
Ref. Documents
Estimated cost
Bid Submission
25 Nov 2024
0 days left
EMD
31250
Bank guarantee accepted
Document Fee
3540
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
rajajipuram → Uttar Pradesh
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Installation of Additional 05 MVA Power Transformer at 33/11 KV S/S Rajajipuram Old from increasing capacity from 3x10 MVAto 3x10+1x5 MVA. & Installation of Additional 05 MVA Power Transformer at 33/11 KV S/S RDSO from increasing capacity from 2x10 MVAto 2x10+1x5 MVA.

BOQ

Name of Work:Installation of Additional 05 MVA Power Transformer at 33/11 KV S/S Rajajipuram Old from increasing capacity from 3x10 MVAto 3x10+1x5 MVA. & Installation of Additional 05 MVA Power Transformer at 33/11 KV S/S RDSO from increasing capacity from 2x10 MVAto 2x10+1x5 MVA.
Sl. No. Item Description
1Dragging, loading, carriage and unloading of following store materials with proper stacking from ESC Daliganj to JE dumps store and from JE dump store to work site within municipal area.
233 KV VCB 800 Amp. 750 MVA
333 KV Control Pannel single circuit Transformer
433 KV Lightening Arrester 400 Amp.
533 KVBus Isolator
633 KV 3x300sqmm XLPE cable
733 KV Jointing Kit Outdoor 3X300sqmm XLPE Cable.
833KVCurrent Transformer 200/100/1
911 KV Incoming VCB 600/300/5A, 350 MVA
1011 KV Out going VCB 200/100/5A, 350 MVA
1111 KV VCB Bus coupler, 350 MVA
12Battery charger 24 Volt
13Battery set 24 Volt
14ACSR Panther Conductor for Bus Bar
1511 KV 3x300mm2 XLPE Cable
1611 KV3x300mm2Outdoor Termination Kit
1711 KV3x300mm2Indoor Termination Kit
1811 KV3x185mm2 XLPE Cable
1911 KV3x185mm2Outdoor Termination Kit
2011 KV3x185mm2Indoor Termination Kit
2111 KV3x185mm2Straight though
22ST pole 11 mtr long
23M.S.channel 100x50 sq mm
24M.S.Angle 65x65x6 sq mm
2511 kv pin insulator
26M S Earthing Rod 20x2500 mm
2711 kv pin with nut
281x240 LT XLPE Cable
29MS Channel 125x65mm 3.5m long 4 Nos Pieces [email protected] Kg. Mtr. With wastage
30MS Angle 75x75x6, 2.6M 2 Nos Total [email protected] Kg./M with wastage
31Copper Control Cable 2x2.5 Sq. mm.
32Copper Control Cable 4x2.5 Sq. mm.
33Rail 105 lb 9 mtr long
34MS Angle 50x50x6 mm
35MS Round of 32 mm dia for laying of main earthmat in switch yard & for panel earthing bridge [email protected] Kg./M
36Earthing of substation Switchyard.
37Earthing of substation Switchyard complete by round bar 32 mm dia exavation of earth for laying of earth mat 750mm deep and proper leveling after laying of earth mat Complete as per specification and connecation of all switchyard equipment by GI Flat 50x6 mm (The contractor shall arrange all the material except MS Round Bar 32 MM)
38Cutting ,fabrication and driving of earth electrode of size 32x3000 mm
39Cutting shaping, laying and welding of riser strip size 50x6mm G.I strip of size 50x6 mm in between earth mat and equipments /structure/body of T/F for earthing (two nos Riser for each structure equipment individually GI strip shall be provided contractor )
40Earthing of Indoor Equipment by making of 2 Nos. Quard of round bar 32 mm dia as per norms.
41Fabrication & Erection of cable stand made of two nos MS channel 100x50x3 mtr. Long jointed to each other by means of 05 nos MS strip 50x6 mm of size 150 mm Long each by welding at equal distance interval as per norms and grouting in block of 300x300x700 completely providing two nos cable clamp also.(All materials will provide by contractor except MS channel).
42Painting of all structures equipment.
43Construction of Power T/F plinth suitable for 33/11KV 05 MVA power T/F of size 4x3x1.3 having 0.4 mtr height above ground level. The work includes excavation of foundation base concreting in cc ratio 1:6 Mas 12 1st class brick work in ratio 1:4 with coarse sand ,foundation cc in ratio 1:4:8using M.S bar of 12 mm dia for reinforcementthe work includes laying of 2 nos rail pieces 4 mtr long as per drawing/practice the plinth shall be finished in all respect. (only rail piece and M.S angle provided by the department)
44Construction of masonry type plinth for 33KV VCB of size 1.6x1.6x1 M brick, sand, cement and stone grit including grouting of 4 Nos foundation Bolts for erection of 33KV VCB.
45Isolator Structure-Fabrication of Isolator structure minimum 3.5 mtr overall height and 2.5 mtr above ground level as per RESSPO drawing, with help of M.S channel 125x65 mm two pieces of M.S channel joined to each other by M.S flat 50x6 mm, diagonally at the interval of 0.5 mtr and top & bottom of the structure. Grouting of Isolator structure in CC (cement ,coarse sand and stone grit of 20 mm gauge) including supply of necessary T&P and painting os structure complete.(only M.S channel and angle provided by the deptt)
46Lightning Arrestor/ CT structure : - Fabrication of lightning arrestor/CT structureas per RESSPO drawing with the help of 2 nos M.S channel 125x65 mm minimum 3.5 mtr long grouting 1 mtr deep from ground level in cc in ratio 1:4:8. complete in all respect.
47Erection of structures, grouting, plinthing of ALL structuresequipment.
48Mounting of accessories/equipment on fabricated structure complete work with making proper alignment and tightening the work includes fabrication work if required for proper operation of equipment .
4933 KV VCB
50CT 200/100/1-A
5133 KV lightning Arrestors
52Bus/Line Isolator
53Fabrication & Erection of Neutral Stand structure with foundation
54Erection commissioning and Testing of 05 MVA T/F mounting of radiator conservator tank exposure vent etc. Filling of T/F oil in radiator conservator tank with complete work as per RESPO Norms.
55Jumpering complete T/F bay with ACSR panther Cond. and required clamp with nut & Bolts from 33KV existing bus bar to T/F complete work.(01 no. T/F bay) ( Except Panther Conductor all required material provided by Contractor.)
56Laying of double circuit 11 KV 3x300 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench.
57Hoisting, jumpering, clamping of 11KV 3x300 sq mm XLPE cable on cable stand and 11 KV VCB panelwith proper taping with the help of empire tape. PVC tape and connectors.
58Construction of Control cable trench of size 150 mm wide 300 mm deep with brick work along with provision trench cover M.S strip at the interval of 0.30 M and M.S angle at both the edge of the trench.
59Construction and fixing of trench cover0.5 M wide 0.75 mm thick with cement, coarse sand & stone grit in ratio 1:2:4 for covering of cable trench150 mm wide with provision of M.S Angle and MS Bar as per RESPO Norms
60Laying of copper control cable of following sizes its proper dressing ,ferruling and connection with the system as per Site Condition with cleaning of Existing Trench.
61Copper Control Cable 2x2.5 Sq. mm.
62Copper Control Cable 4x2.5 Sq. mm.
63Pipe boring type earthing minimum 20 mtr deepfrom ground level or upto water level with B class G.I. pipe 2 \" dia. Connection of equipment with earthing by GI strip 50x6 mm included in the job as per specification/norms for power transformer, VCB, CT/LA and other. (All materials will be Provided by contractor)
64Extension of 33 kV Bus Bar Gantary complete with structure and other required work. (Except rail/angle/channel/panther conductor all required materials provided by contractor)
65Dragging of following panels (Control and feeder pannel) from unloading place upto control room and placement erection and grouting, commissioning & testing of the same as per RESPO Norms
6633 kV T/F Control panel
6711 KV Incoming VCB 600/300/5A
6811 KV Out going VCB 200/100/5A
6911 KV VCB Bus coupler, 350 MVA
70Interloking Soling and gravels in switch yard as per Norms.
71Supply of following auxiliary material
72Rabber mat 2x1.5 Mtr.
73Erection of 24 V batteries set with charger including stand (Except batteries set with charger all material and stand shall be provided by contractor) & initial charging complete set.
74Grouting,Plinthing and Painting of new erected 11M long ST poles of single pole support,double pole cableexposures
75Digging of Pit in kachcha/Pakka land in depth upto 1/6 length of Pole, Dragging of STP from near by place/Dump, Erection of Single pole along with stone pad in bottom with proper alignment of line for 11 KV line on 11 M long ST Pole and refilling with ramming of earth.
76Grouting of pole in depth of 1/6 the length of pole in ratio 1:4:8 in cement sand and brick balast as per RESPO norms.
77Construction of pole plinth 300mm x 450 mm above ground levelin 1:2:4 in cement, coarse sand and stone gritt as per RESPO norms.
78Painting of new erected ST pole with two coat of red oxide paint,PO red paint at top of pole 2 M& balance by twocoats ofbest quality aluminium paint ISI of Burger/Nerolac/Asian mark as pernorms.
79Fabrication & erection of 11 KV cable exposure type double pole with the provission ofcable with fixing of necesory clamps and other acessories like danger board,number plate,barbed wire,2 no. channels 100x50mm (1600mm each),1 no.MS channel 100x50mm(3200mm in length) for supporting the hoisting of cable & poles.its jumpering by single core PVC aluminium cable with proper size Al.lug after making three phase busbar with help of 11 KV pin,pin insulator and PVC cable. (all material arranged by contractor except steel,pole & insulator).as per RESPO norms.
80Hoisting of 11KV3X185 sqmm XLPE cable on double pole with MS pipe/GI pipe of size 5/6\" dia 3 M longincluding its jumpering complete with clamps, nuts and bolts(all material arranged by contractor).
81Laying of Single circuit 11 KV 3x185 sq mm XLPE cable in normal soil/already Constructed trench/As per Site Condition by digging of suitable size of trench as per site condition cable should be covered by bricks and sand with cleaning of Existing Trench.
82Hoisting, jumpering, clamping of 11KV 3x185 sq mm XLPE cable on 11 KV panelswith proper taping with the help of empire tape. PVC tape and connectors.
83High Pressure Testing
84Provided NOC from Electrical Safety department for Energization of 5 MVA Transformer. (The amount will be reimbursed as per actual expenditure/receipt issued by concerned department upto maximum limit of Rs. 50000.00)
85Note :-Return balance materials to LESA store daliganj and other work in site area.

AI Tender Summary

OUR REF NO 46273191
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 25-11-2024
Authority
Authority Name Madhyanchal Vidut Vitran Nigam Limited
Work Description Installation of Additional 05 MVA Power Transformer at 33/11 KV S/S Rajajipuram Old from increasing capacity from 3x10 MVAto 3x10+1x5 MVA. & Installation of Additional 05 MVA Power Transformer at 33/11 KV S/S RDSO from increasing capacity from 2x10 MVAto 2x10+1x5 MVA.
Basic Detail
Tender No 11/EUCC-V/LESA/2024-25
Bidding Type Tender
Location
City rajajipuram
State Uttar Pradesh
Key Dates
Publish Date 20 Nov 2024
Submission Date 25 Nov 2024
Open Date 26 Nov 2024
Finance
Tender Value Ref. Documents
Tender Fee 3540
EMD 31250
Exemption Not Available
Document List
5f5e0355-a627-4927-bbbe-fba7698db93f.html
BOQ_1711546.xls
documentup.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 20, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 25, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 26, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

5f5e0355-a627-4927-bbbe-fba7698db93f.html

xls

BOQ_1711546.xls

pdf

documentup.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail