Tender For Repair And Maintenance Of Amf, Distribution Panels, Mfp And Sfp Of Bfl Panels Installed At Various Bops In Aor Of 109 Bn Bsf Under Shq Bsf Udaipur
Tender Value
17.97 Lakhs
Estimated cost
Bid Submission
29 Nov 2024
0 days left
EMD
35958
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
Tripura → Tripura
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Repair And Maintenance Of Amf, Distribution Panels, Mfp And Sfp Of Bfl Panels Installed At Various Bops In Aor Of 109 Bn Bsf Under Shq Bsf Udaipur
BOQ
| Sl. No. | Item Description |
| 1 | Earthingwith GI earth pipe4.5 mtr long x 40 mm dia including accessories and providing masonry enclosure with cover platehaving locking arrangement and watering pipe etc. (with charcoal or coke and salt)as required |
| 2 | Providing and laying earth connection from earth electrode with 6 SWG dia G I wire in 15mm dia G I pipe from earth electrode including connection with G. I. Thimble excavation and re-filling as required. |
| 3 | Providing and fixing MCX32, 4 pole contactor, 160 amp in existing panel board including drilling holes in existing cubical panel, making connections including dismantling of defective contractor etc as reqd.make L&T code No,CS97020, frame size 4 or its compatible to Havells/Standard/Legrand/C&S. (including less of retrive/scrapped material, dismentle Contractor will not be taken back). |
| 4 | Providing and fixing 160 amp MCCBs, 4 pole with breaking capacity 36 KA, 415 volts with suitable operating mechanism extended rotary handle and spreader terminal in existing cubical panel board including drilling holes in cubical panel, making connections (Including deducting the cost of old scapped material) etc as reqd.Make-L&T Cat No.CM98065OONO or its equivalent make ofHavells/Standard/ Legrand/ ABB/ C&S. |
| 5 | Providing and fixing 32 amps, 415 volt, TPN Disconnector fuse switch unit open execution with suitable HRC fuse link, for fixingin existing SS enclosure with door interlock facility including dismantling of defective one, drilling holes complete with connections, testing, commissioning etc as reqd. L&T make cat no.SK95703or its compatible to Havells/or its equivalent make ofHavells/Standard/ Legrand/ABB/C&S. |
| 6 | Providing and fixing 63 amps ,415 volt ,TPN Disconnector fuse switch unit open execution with suitable HRC fuse link,for fixingin existing SS enclosure with door interlock facility including dismantling of defective one, driliing holes complete with connections,tetsing, commisioning etc as reqd.L&T make cat no.SK95704 or its compatible to Havells/or its equivalent make of Havells/Standard/legrand.(including less of retrive/scrapped material, dismentle TPN disconnector fuse switch will not be taken back) |
| 7 | Providing and fixing 125 amps, 415 volt, TPN Disconnector fuse switch unit open execution with suitable HRC fuse link, for fixingin existing SS enclosure with door interlock facility including dismantling of defective one, drilling holes complete with connections, testing, commissioning (Including deducting the cost of old scapped material) etc as reqd. L&T make cat no.SK95001 or its compatible to Havells/or its equivalent make of Havells/ABB/Standard/Legrand. |
| 8 | Providing and fixing 250 amps, 415 volt, TPN Disconnector fuse switch unit open execution with suitable HRC fuse link, for fixingin existing SS enclosure with door interlock facility including dismantling of dfective one, driliing holes complete with connections, tetsing, commisioning etc as reqd. L&T make cat no.SK95642or its compatible to Havells/or its equivalent make ofHavells/Standard /Legrand/C&S (including less of retrive/scrapped material, dismentle TPN disconnector fuse switch will not be taken back)make of Havells/ABB/Standard/Legrand. |
| 9 | Providing and fixing Combined Digitaltype display meter suitable for measuring Ac voltage, current, KWH, KW, PFFrequency etc having three line display3 phase multifunction meter in existing cubical panel board including, making connections (Including deducting the cost of old scapped material) etc as reqd. Make L&T code No.WL441010OOOO or its equivalent make of havells/ABB/seimens/Legrand/C&S. |
| 10 | Replacement of defective spare contact coil for 160 amp,240 volt MCX32, 4 pole contactor, making connections including dismantling of defective contractor kit(Including deducting the cost of old scapped material) etc as reqd.make L&T code No,CS94196 or its compatible to Havells/Standard/Legrand/C&S. |
| 11 | Providing and fixing of 250 amps , 415 volt, Bolted fuse link suitable for 125 amps disconnector fuse unit, size B3 conf. IS/IEC 60947-3 and testing , commissioning and dismantling of existing fuse etc. as required Make-L&T cat no ST30781 or its compatible to Havells/Standard/Legrand/Schneider |
| 12 | Providing and fixing of 125 amps , 415 volt, Bolted fuse link suitable for 125 amps disconnector fuse unit, size A4 conf. IS/IEC 60947-3 and testing , commissioning and dismantling of existing fuse etc. as required Make-L&T cat no ST30769 or its compatible to Havells/Standard/Legrand/Schneider . |
| 13 | Providing and fixing of 63 amps , 415 volt, Bolted fuse link suitable for 63 amps disconnector fuse unit, size A1L, conf. IS/IEC 60947-3 and testing , commissioning and dismantling of existing fuse etc. as required Make-L&T cat no ST35828 or its compatible to Havells/Standard/Legrand/Schneider . |
| 14 | Providing and fixing of 32 amps , 415 volt, Bolted fuse link suitable for 32 amps disconnector fuse unit, size A1L, conf. IS/IEC 60947-3 and testing , commissioning and dismantling of existing fuse etc. as required Make-L&T cat no ST34529 or its compatible to Havells/Standard/Legrand/Schneider . |
| 15 | Providing & Fixingofanalog Ammeter (0-200 amp) size- 96x96 Switch for suitableall accessories of three phase 415 volt 50 Hz inexisting electrical panel as per details specification make - L&T/ Havells/AE |
| 16 | Providing & Fixingofanalog voltmeter (0-500 volt) size- 96x96 Switch for suitableall accessories of three phase 415 volt 50 Hz inexisting electrical panel as per details specification make - L&T/ Havells/AE |
| 17 | Providing & FixingofAmmeter selectorSwitch for suitableall accessories of three phase 415 volt 50 Hz inexisting electrical panel as per details specification make - L&T/ Havells/AE |
| 18 | Providing & FixingofVoltmeter selectorSwitch for suitableall accessories of three phase 415 volt 50 Hz inexisting electrical panel as per details specification make - L&T/ Havells/AE |
| 19 | Supplying & fixing ofLED indicator 16 mm surface mounted low power consumption, surge & low voltage glow protection cat no SIL, in the yellow and Blue colours, L&T make, including connections with 0.75 sqmm FRLS single copper conductor cable etc. as reqd. |
| 20 | Supplying and making interconnections with 16 sqmm size of single core, Heavy duty (unsheathed)PVC insulated 1.1 KV grade copper conductor cable betweenswitch gears, bus bars and connector etc of existing panel including providing suitable size cable lugs/ thimblesetc complete as required.(Finolex/KEI /Havells/L&T) (including less of retrive/scrapped material will not be taken back) |
| 21 | Supplying and making interconnections with 35 sqmm size of single core, Heavy duty (unsheathed)PVC insulated 1.1 KV grade copper conductor cable betweenswitch gears, bus bars and connector etc of existing panel including providing suitable size cable lugs/ thimblesetc complete as required.(Finolex/KEI /Havells/L&T) (including less of retrive/scrapped material will not be taken back) |
| 22 | Providing and fixing of Bakelite open connector 4P,suitable for125 ampsin existing cubical panel board including, making connections etc. as reqd |
| 23 | Providing & fixing of capsule type metal panel hinges (plain electric panels) size 16 mm X 2.5 inch for main/sub feeder pillar door/cover installed at BFLs pole, includingfixing by gas/ arc welding on existing looping box/bus bar chamber etc. as required. |
| 24 | Add GST@ 18 % on DSR Item 2022 instead of 12% (Multiplying Factor 1.0633) |
| 25 | Add Labour cess @ 1% on Total) |
AI Tender Summary
Tender Timeline
Nov 19, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedNov 29, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedDec 02, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender