| 1 | Design drawing construction,commissioning & testing of 8.0 meter diameter RCC Intake well(upto 20m depth)including dewatering,cofferdam ,5m height pump house on the well,EOT crane ( 8 Ton capacity) arrangement, 3.5 mtr wide RCC walk way50 RM (as per requirement to intake pump house but excluding external electrification,raw water pump approach to site,spur and cutoff wall. |
| 2 | Design,Drawing, construction of Stone pitching at Intake well as per drawing and complete in all respect as per technical specification and as per direction ofEngineer-In-Charge..Supplying all labour, T&P and Earth work in excavation of all kinds of Soil with in 50m intial lead and 1.5m intitial lift including rough dressing and breaking the clods to maximum 5cm to 7cm and laying in layers not exceeding 0.30m in depth as per direction of Engineer-In-Charge. |
| 3 | Random rubble H.G. stone Masonry in cement mortar (1:6) in foundation and plinth. |
| 4 | 2.5cm. Dam proof course with C.C (1:2:4) using 12mm. size hard broken granite chips |
| 5 | Supplying all labour, T&P forEarth fillingby mechanical means from approved quarry , compacting , watering including transportation, royalty all complete as per direction iof EIC |
| 6 | Dry stone masonry or rough stone dry masonary for guard walls and retaining walls with granite |
| 7 | Cement flush pointing to brick masonry ( 1 : 3) |
| 8 | Design,Drawing, construction of Leading Channel for Intake well as per drawing and complete in all respect as per technical specification and as per direction of Engineer-IN-Charge.(Detailed estimate enclosed)Earth work in all kinds of soil within 50mtr initial lead and 1.5mtr initial lift including rough dressing and breaking of clods to maximum 5cm to 7cm and laying in layers not exceeding 0.3mtr in depth as per direction of Engineer-in-charge.(per%cum) |
| 9 | Cement concrete (1:3 :6) with 4cm size hard granite metal. |
| 10 | R.C.C work in ground floor of M-20 gradewith 20mm & down grade crusher broken Granite chips |
| 11 | Providing, Cutting,Bending. Binding, Hooking, Tying, & Placing in proper position with TOR Steel with cost conveyance and taxes of all material with cost of all labour& T&P required for the work etc. complete |
| 12 | Supplying all materials, labour, T&P and providingrigid andSmooth centering and shuttering for R.C.C. works including False work and dismantling them after casting including Conveyance of all materials to Work site, payment of royalty,contractor profit & labour cessetc all complete as per specification and direction of Engineer-in-charge.Rigid smooth centring and shuttering Slabs |
| 13 | Walls |
| 14 | Supply Instalation, Testing and commissioning of approved makeVFDcompatibleV.T pump set of given capacityand head, TEFC squirrelcage solid shaft inductionmotor working on 3- Phase50 Hz ± 5%, 0.4KV ± 10%,complete set as per relevantIS andfollowingmaterialof Construction:ImpellerwithwearingringCF8M, Shaft with sleeve S.S., Casing- C.I., Columnpipe - M.S, Base frame M.S With 2 No. Stand by and 1440 RPM-(4 nos)including third party inspection such as RITES/TUV /PDIL/CIPET/Govt.approved agencyDuty condition: discharge-42 lps, head-145 meter |
| 15 | Construction,Design & drawing of Buildingfor Indoor HT meter Cubicle Roomfor Intake and complete in all respect as per technical specification and as per direction of Engineer-IN-Charge |
| 16 | Providing, installation, testing and commissioning of Electromagnetic Flow Meter etc. including all materials(excluding CI/DI fittings) andmaking connection with existing pipeline required forElectromagnetic Flow Meter including cutting the existing pipe line etc. complete in all respect as per technical specification and as per direction of Engineer.(KROCHE MARSHALL,E & H,ADEPT,SIEMENS)400mm at Inlet to WTP |
| 17 | 500 mm At outlet of Intake |
| 18 | Supply with fitting and fixing of of D.I. Mechanical dismentaling joint for use to main uninterrupted water supply in the pipeline in case eof rpair of Flow meter as per specification and direction of Enginer - in - charge400mm |
| 19 | 500 mm |
| 20 | Supplying, Fitting,Commissioning,Fixing double chamber DI PN 16 control valve,hydraulically operated, single diaphragm actuated, globe pattern. The valve shall consist of three major components; the body with the seat installed; the cover with the bearing installed and the diaphragm assembly. The diaphragm assembly shall be the only moving part and shall form a sealed chamber in the upper portion of the valve, separating the operating pressure from line pressure. Packing glands, stuffing boxesand there shall be no piston operating the main valve or pilot controls. No fabrication or welding shall be used in the manufacturing process.The control will be achieved by operating a Stainless Steel Float connected from OGR / UGR to the main Valve, integral oriface plate assembly, differential control, reverse flow control, restriction orifice.The Connecting tubing on the Main Valve will be PU or SS with SS fitting from reputedmake. The valve shall be working up to 3.0 kg/cm2 operating pressure, Body DIintegrated with PLC pannel for operation (local/remort and web enabled with command and control) make CLA/SINGER/HAWLE to control or open & close water supply,including the cost of valve cutting the pipeline & making good to the damagesincludingcost ofall labours, T&P etc. all completeas per the direction of Engineer-in-charge. (globe type)150mm dia D/F actuatorSluice Valve (PN1.6) (KIRLOSKAR/VAGUE/TALIS/HAWLE) |
| 21 | 150mm dia D/F Non Return Valve (PN1.6)(KIRLOSKAR/VAGUE/TALIS) |
| 22 | Enclosure for the LT 630A CapacityACB control panel board with APFC made out of CR sheet having Size-Height-2000MM X Breadth-4250MM X Depth-1000, Floor mounting with primer coated with Powder coated paint and provided with required gasket for dust / vermin proof with degree of protection IP42 suitable for 415V ,3 phase, 50Hz, 4 wire system fabricated up to 2MM thick (1.6 mm for doors) with panel accessories.{Panel weight consider from analysis}, 630A,4Pole,50kA/EDO, Microprocessor Based Air Circuit Breaker For Main Incomer(Make-SIEMENS/ L&T/ SCHNEIDER/ABB/BCH/C&S), 25A, Breaker control switches (Trip-Neutral-Close).(Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/ SCHNEIDER/ ANCHOR), 25A,Local-Remote, Auto-Manual Switches.(Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/ SCHNEIDER/ ANCHOR), Indicator(Red/Yellow/Green).(Make-L&T/ C&S/ABB/BCH), Indicator(Blue).(Make-L&T/C&S/ABB/BCH), Three phase Digital Ammeter Accuracy class-1.0.(96 x 96 MM/MAKE--SECUR/ C&S/ TECHNO) (l.S), Three phase Digital Volt meter Accuracy class-1.0.(96 x 46 MM/MAKE--SECURE/ C&S/ TECHNO) (L.S), 10A/AC3 Auxiliary Contactor/ 230V .(Make-L&T/ BCH/ TC/ABB/ C&S /SIEMENS/SCHNEIDER/ANCHOR), 6A /4Pole M.C.B.for meter wiring. (Make-L&T/BCH/TC/ABB/C&S), 6A /2Pole M.C.B.for fan & relay wiring. (Make-L&T/BCH/TC/ABB/C&S). Copper Bus-Bar(40MM X10MM)/ (50MM X8MM).Weight consider from analysis,600/5A VA-15,CL-1,ID-70MM C.T.(Make-KAPPA/AE/ELMEX) (L.S), 50-63A/4PoleM.C.C.B,36kA{For light load-1nos & ancillary load-1nos}.(Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/SCHNEIDER), 1.5MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI)(L.S), 4MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI)(L.S), 10MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI)(L.S) and 1.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/ DOWELLS) (L.S), 4-6MM² Cable Socket (Cop). (Make-KAYCEE/PTR/ DOWELLS) (L.S), 10MM² Cable Socket (Cop). (Make-KAYCEE/PTR/ DOWELLS) (L.S), 25 X 25 MM PVC Cable Ducts.(Make-L&T/SALZER/ KAYCEE), 25 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER /KAYCEE), 150MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), 200MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), PVC Tape(Make-STEELGRIP/ ANCHOR/CONA), MCB fixingIron Channel / DIN 15/5.5MM - 1M ( suitable for M4 Terminal).(Make-WAGO/SALZER), Finger Type Insulator/one Bus -Bar SupportFor Capacitor Bank.(Make-RAMANUJ/ WAGO), Bakelite sheet(Thick-4MM, Required size - 10\" X 28\" = 4nos, 10\" X 18\" = 10nos, 10\" X 8\" = 2nos, 28\" X 28\" = 4nos,35\" X 28\" = 2nos),12MM PVC Spiral (L.S.),25MM X 25MM PVC Mount (L.S.),2.5MM² Ferrules. 73MM Colour Insulated HeatShrinkable Sleeves.(Make- RAMANUJ) (L.S), Galvanized coated nut-bolt,Plain washer,Spring washer (L.S.) -All quantity as per requiement. |
| 23 | 110KW VFD, following specification:- Ambient temperature - -10 to + 50°C; up to + 60°C with derating at 2% per degree rise in temperature. Protection design - IP20 standard, NEMA Type 1-Kit ( optional), IP55/NEMA Type 12 external heatsink ( factory option). Mounting - Horizontal ( 0.75 KW to 75 kW (HD). Overload capacity - 150 % 1 min. (HD, heavy duty) or 110% / 1min. (ND, normal duty. Rated voltage - 200 to 240 VAC, -15 to +10 % 50 / 60 Hz +/-5 %. Output frequency - 0 to 590 Hz. Carrier frequency - 400V Class; 2-15 kHz up to 55KW (ND) ; 2-10 kHz from 75 kW (HD); 2 kHz from 250 kW to 355 kW (ND).Control inputs - 8 digital (sink / source), 3 analog (current/voltage), 1 pulse (HTL, max. 32 kHz), Control output - 4 relay 2 analog ( current/voltage), 1 pulse (HTL, max. 32kHz), 24 Vdc for external sensors available (max. 150 mA) Motor types - Induction Motor ( IM), permanent Magnet Motor (IPM/SPM), Synchronous Reluctance Motor(S (SynRM).Protective functions - Stall prevention, overload prevention,overtemperature prevention - and further protective functions for the motor,the application and the inverter drive. Self-monitoring - Monitoring of main components ( fans, IGBTs, capacitors, charging circuit) with alarm when reaching a certain lifetime.(Make-SIEMENS/ L&T/ SCHNEIDER /ABB/ YASKAWA), 160A/3pole MCCB 50k(Make-L&T/ABB/SIEMENS/BCH/C&S/SCHNEIDER), 250-320A/3PoleM.C.C.B,36kA (Make-L&T/ ABB/ SIEMENS/ BCH/ C&S/ SCHNEIDER), Three phase Digital Ammeter Accuracy class-1.0.(96 x 48MM/MAKE--SECUR/C&S/TECHNO), Three phase Digital Volt meter Accuracy class-1.0.(96 x 48 MM/MAKE--SECURE/ C&S/ TECHNO),Indicator(Red/Yellow/Green).(Make-L&T /C&S /ABB /BCH /TC), Indicator(Blue).(Make-L&T/C&S/ABB/BCH/TC), 10\"Cooling fan(MAKE-HIGH COOL / SALZER/ KAYCEE), 6A /4Pole M.C.B.for meter wiring. (Make-L&T/BCH/TC/ABB/C&S), 6A /2Pole M.C.B.for control wiring (Make-L&T/BCH/TC/ABB/C&S), and 10A/AC3 Auxiliary Contactor/ 230V .(Make-L&T/ BCH/ TC/ABB/ C&S /SIEMENS/SCHNEIDER/ANCHOR), 315A, Din Type HRC Fuse Links. (Make-L&T/ SIEMENS/ ABB/ BCH/ C&S/SCHNEIDER), 200-800A, Din Type HRC Fuse Base.(Make-L&T/ SIEMENS/ ABB/BCH/ C&S/SCHNEIDER), 1kva(as per VFD control voltage required) Control transformer.-1No, Copper Bus-Bar(30MM X6MM) weight consider from analysis, 300/5A VA-15,CL-1,ID-55MM C.T.(Make-KAPPA/ AE/ ELMEX), Push-Button with Indicator(Make-L&T/BCH/TC/ABB/C&S), Contact Eliment-NO/NC.(Make-L&T/BCH/TC/ABB/C&S), 1.5MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX / KEI)(L.S), 1.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/DOWELLS) (L.S), Single Pole Bus-Bar Support (Make-RAMANUJ/WAGO), 25 X 25 MM PVC Cable Ducts.(Make-L&T/ SALZER/ KAYCEE), 25 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER /KAYCEE), 150MM cable Tie.(Make-HOODS/ ELETTRO) (L.S.), 200MM cable Tie. (Make-HOODS/ ELETTRO) (L.S.), PVC Tape(Make-STEELGRIP/ ANCHOR/CONA)(L.S.), MCB fixingIron Channel / DIN 15/5.5MM - 1M ( suitable for M4 Terminal). (Make-WAGO/SALZER), 12MM PVC Spiral (L.S.), 25MM X 25MM PVC Mount , 2.5MM² Ferrules, 55MM Colour Insulated HeatShrinkable Sleeves.(Make- RAMANUJ), Galvanized coated nut-bolt,Plain washer,Spring washer (L.S.)-All quantity as per requiement. |
| 24 | 250-320A/3PoleM.C.C.B,36kA (Make-L&T/ ABB/ SIEMENS/BCH/C&S/SCHNEIDER), 400A/3P/1set of 6 Spreader Terminals. (Make-L&T/ C&S/ BCH/ TC/ABB/SCHNEIDER/SIEMENS), 6A /4Pole M.C.B.for meter wiring. (Make-L&T /BCH /TC/ABB/C&S), 6A /2Pole M.C.B.for fan & relay wiring. (Make-L&T/BCH/TC/ABB/C&S), 10A /3Pole M.C.B.for 5KVAR capacitor(Make-L&T/ ANCHOR /C&S/ABB/BCH/SIEMENS), 20A /3Pole M.C.B.for 10KVAR capacitor(Make-L&T/ MARU/ C&S /ABB/BCH/ANCHOR/LEGRAND), 32A /3Pole M.C.B.for 15KVAR capacitor(Make-L&T/ MARU/ C&S /ABB /BCH /ANCHOR /LEGRAND), 40A /3Pole M.C.B.for 20KVAR capacitor(Make-L&T/ MARU/ C&S /ABB/BCH/ANCHOR/LEGRAND), 1.5MM² single core copper cable. (Make-POLYCAB/ HAVELLS /FINOLEX/KEI) (L.S), 2.5MM² single core copper cable {For 5KVAR Capacitor} (Make-POLYCAB/ HAVELLS /FINOLEX/ KEI) (L.S.), 6MM² single core copper cable {For 20KVAR Capacitor} (Make- POLYCAB/HAVELLS /FINOLEX/ KEI) (L.S.), 4MM² single core copper cable {For 15KVAR Capacitor} (Make- POLYCAB/HAVELLS /FINOLEX/ KEI) (L.S.), Indicator(Red/Yellow/Green).(Make-L&T/C&S/ABB/ BCH), Indicator(Blue).(Make-L&T/C&S/ABB/BCH), Three phase Digital Ammeter Accuracy class-1.0.(96 x 48 MM/MAKE--SECURE) (L.S), Three phase Digital Volt meter Accuracy class-1.0.(96 x 48 MM/MAKE--SECURE) , 1.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/DOWELLS) , 2.5MM² Cable Socket (Cop). (Make-KAYCEE/PTR/DOWELLS (L.S) , 4-6MM² Cable Socket(Cop).(Make-KAYCEE/PTR/DOWELLS), 200/5A VA-15,CL-1,ID-55MM C.T.(Make-KAPPA/AE/ELMEX),12 Steps APFC Relay,230V (Make-EPCOS/L&T/C&S), 21kva/0-280V Control transformer, 7KVAR Capacitor duty contactor.(Make-EPCOS/L&T/ C&S), 10KVAR Capacitor duty contactor(Make-EPCOS/ L&T/ C&S) and 20KVAR Capacitor duty contactor(Make-EPCOS/ L&T/ C&S), 5KVAR Capacitor,440V(Make-EPCOS/C&S/L&T), 10KVAR Capacitor,440V(Make-EPCOS/L&T/C&S), 15KVAR Capacitor,440V(Make-EPCOS /L&T /C&S) , 20KVAR Capacitor,440V(Make-EPCOS/L&T/C&S), 4\"Cooling fan(MAKE-HIGH COOL / SALZER/ KAYCEE), Copper Bus-Bar(40MM X6MM). (Weight consider from analysis), Single Pole Bus-Bar Support(Make-RAMANUJ /WAGO), Base 2pole connector(Make-RAMANUJ/WAGO) , MCB fixingIron Channel / DIN 15/5.5MM - 1M ( suitable for M4 Terminal).(Make-WAGO/SALZER), 25 X 25 MM PVC Cable Ducts.(Make-L&T/SALZER / KAYCEE), 45 X 30 MM PVC Cable Ducts.(Make-L&T/SALZER /KAYCEE), 25 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER /KAYCEE), 45 MM PVC Cable Ducts Cover.(Make-L&T/ SALZER/ KAYCEE), 150MM cable Tie.(Make-HOODS/ELLETRO), 200MM cable Tie.(Make-HOODS/ELLETRO), PVC Tape(Make-STEELGRIP/ ANCHOR/ CONA), 12MM PVC Spiral.(L.S.), 25MM X 25MM PVC Mount, 2.5MM² Ferrules, 73MM Colour Insulated HeatShrinkable Sleeves. (Make- RAMANUJ), Galvanized coated nut-bolt,Plain washer,Spring washer.(L.S.)-All quantity as per requiement. |
| 25 | L.T 300MM²,3½Core/ X 1R,Armoured,Aluminium Cable.(Make-HAVELLS/POLYCAB /FINOLEX/KEI) {For transformer to panel DG to panel) |
| 26 | L.T 25MM²,3.5Core/ ,Armoured, Aluminium Cable.(Make-HAVELLS/ POLYCAB /FINOLEX/KEI) {For transformer to panel DG to panel) |
| 27 | L.T 10MM²,4Core/ ,Armoured, Aluminium Cable.(Make-HAVELLS/ POLYCAB /FINOLEX/KEI) {For transformer to panel DG to panel) |
| 28 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/HUME/ METAL pipe as required.Above 185MM² and upto 400MM² |
| 29 | Upto 35MM²AND up to 95MM2(For 4core/10MM²-100Mtr + 16core / 2.5MM²-800Mtr) |
| 30 | Upto 35MM² (For 4core/10MM²-100Mtr + 16core / 2.5MM²-800Mtr) |
| 31 | 95MM² single core/ X 3R flexible copper cable.(Make-Havells/Polycab/ Finolex/KEI) |
| 32 | Laying and fixingof one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on cable tray as required.Above 35MM² and upto 95MM²(cop) |
| 33 | 50MM² Cable Socket(Cop). (Make-KAYCEE/PTR/DOWELLS)(L.S.) |
| 34 | Supplying and installing following size of perforated painted with powder coating M.S cable trays with perforation not more than 17.5%, in convenient section, joined with connectors, suspended from the celling with M.S suspenders including bolts & nuts, painting suspenders etc as required.200 mm width X 50 mm depth X 1.6 mm thickness. |
| 35 | 300 mm width X 50 mm depth X 1.6 mm thickness. |
| 36 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 240MM² (62mm) {Alu} |
| 37 | 3 X 95MM² (45mm) {cop} |
| 38 | Supplying and making outdoor endtermination with cast resin compound including aluminium lugs and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required.3½ X 240MM²{Alu} |
| 39 | Desiging, supplying, installing, commissioning & testing of CCTV IR water proof camera suitable for upto 100ft. with control key board, DVR, Hard Disk,cables, UPT transreceivers etc. complete with not less than following specifications 1. Four numbers of IP Camera with night vision functionality with range up to 30 meters. Camera construction shall be suitable for weather proof outdoor installation. 2. Eight Channe DVR withmetal body consturction, having software features of motion detect recording. 3. 3.5 inch 2 GB HDD 4. 8 port POE Switch 5. 32 inch LED Screen, Keyboard & mouse .Make- Hikvision, CP Plus, Evision, Honeywell all completeas per specification anddirection of Engineer-in-charge. |
| 40 | Supply, installation and testing of Maintenance free safe Earthing Electrodes with ISI G.I pipe dia75mm as Secondary electrode with wall thickness of 2.6 mm and the Primary Earthing Electrode will be 50mm X 6mm X 1no M.S hot dipped galavanized strip filled with a highly conductive & non-corrosive compound inbetween the Primary Earthing and the secondary Earthing, the surface Area in will be 7,06,500sqmm for 3mtrs length and cross sectional primary conducting area is 300 sq.mm An Solid G.I Base plat seals the unit at the bottom and providing of masonry enclosure with cover plate.as per direction of Engg.-in-charg (MES- GFC ground Filling compound will be provided in 25 kgs Bags.) (MES-GFC ground Filling compound will be provided in 25 kgs Bags.) (2 bags required for each earthing electrode.) 2nos earthing connection all motors and 2nos earthing connect in all panel. |
| 41 | Providing and fixing 25 mm X 5 Mm G.I . Strip on surface or in recess for connections etc. as required. |
| 42 | First aid Box, Shock treatment chart.(Odia / Hindi & English ), 8MM thick Rubber Mat, Danger Board.(200MM X1500MM) |
| 43 | Providing & Fixing of IK07 IP 66 protected LED Street Light Luminaire on existing bracket/pole. Fixture made of powder coated single piece pressure die cast aluminum LM6/ ADC12 material with heat dissipation fins on housing with UV stabilized PC/Toughened Glass cover (UV stablzation report submitted for UV cover ) and secondary lens on each LED & should be SMD type . The System level Luminaire efficacy >=120 lm/ wt with High Power LEDs is to be used and potted driver must be potted & has a unique BIS R number with Input Voltage AC 120 to 270 V AC with High voltage Cutoff @>=300 V AC and Auto resetting Safety ,Input Frequency 50Hz±3% Power Factor >0.95 driver Efficiency >85% ,THD(I) 70 and CCT 5700K +355K. Surge protection shall be min ≥ 4 KV internal and min 10 KV external. driver should be Phase to phase protection of 440 V for 4 Hrs. Manufactures Word Mark/Name Engraved/Embossing on die cast housing to allow traceability/authenticity. Fixture shall be AS PER IS 10322 Complianced.LED Street Light fixture 60 Watt |
| 44 | Supply and erection of M.S. Galvanized Octagonal pole ( as per BSEN 40-3-3:2003 /BSEN 10025/IS 2062 IS:875 Part-1 – 2015/ for MS plate for base flange )of following length and dimension as per table P-01 with base plate on the cement concrete foundation of M20 grade (1:1.5:3) as per IS 456/IS 2911. with the help of anchor bolts of grade 6.8 (IS: 1367 P III ). The pole shall have a weatherproof flush door and locking arrangements. complete in all respect. All as per pre approved by Engineer in charge. For additional technical parameters of products/ work , refer Annexure\"A\" attached with this BSR .Octagonal MS Poles made of S-355JO grade steel sheet , folded lengthwise to obtained Octagonal shape, having single longitudinal seam weld and hot dipped galvanised internally & externally in accordance with IS 2629(5.0METER HEIGHT) |
| 45 | Construction,Design & drawing of Electrical and MCC Control Room single Storey Building complete in all respect as per technical specification and as per direction of Engineer-IN-Charge |
| 46 | (5 year )five year operation and maintenance)(Including contribution towards EPF, ESI, Labour cess, Contractors Profit & OH Charges but excluding cost of chemicals & Energy charges) Supply ofmanpower consisting of 2 no ofNumbers of pump driver and 3 no of helper manpower in daily baisincluding materials require for repairand maintenance of Pump set,VFD Panel, APFC Panel, pipe lines , Sluice valves,air valves,NR Valves, MS pipelaid under this project including painting, repair and replacement of damageditems, spares etcfor the item of the works executed under this project .as per specification and direction of the Engineer-in-charge. |