| 1 | Comprehensive maintenance of Central Gas supplySystem complete and its allied equipments including minor repair of manifold panel for Oxygen- 300 Points,Nitrous Oxide-14 and vaccum system- 300 Points,Air-51 points, CO2 -07 points, pipe line, Two nos Air Compressor pump/motor ,two nos. vaccum pump and cylinder and empty indication system for a period of 11 calender months.NOTE: Unit rates shall deemed to be inclusive of taking down unserviceable defective parts/accessories and replacement with new one, including fixing of spare parts as and when required including welding/soldering etc for smooth and efficient functioning of the system ,changing of lubricating oil (Castor-30) of two nos vaccum pump once in a year ,complete all as specified and directed at site.(New spare parts shall be measured and paid separately as supply only under relevent item here-in-after) and if any spare required except undermentioned here-in-below is included with the quoted rates. |
| 2 | Supply onlyOR - 14 regulator for oxygen& Nitrious control panel as per sample. |
| 3 | Supply only gauge for oxygen & Nitrious 0 to 14 Kg as per sample. |
| 4 | Supply only non Return valve ,which issuitable used oxygen,nitrious& CO2 manifoldas per sample. |
| 5 | Supply only self seal double lock valve for oxygen as per sample. |
| 6 | Supply only self seal double lock valve for Nitrious as per sample. |
| 7 | Supply only self seal double lock valve for vaccumas per sample. |
| 8 | Supply only safety keyed plug for oxygen as per sample. |
| 9 | Supply only safety keyed plug for Nitriousas per sample. |
| 10 | Supply only safety keyed plug for Vaccum as per sample. |
| 11 | Supply, Installation, Jointing, Testing and Commissioning in repair of following Medical grade Copper Pipe line with suitable fiittings. .Copper pipe shalll be solid drawn,seamless,deoxidized,non arsenical,half hard,tempered and degreased material conforming to BS:EN:13348:2001+A1:2005. Fittings would be made of copper and suitable for a steam of working pressure of 17 bar and conforming to BS:864 with specially made for brazed socket type connection.Complete all as specified and as directed. (Certified 18-04-57). Make- Metal Alloys/Max flow or equivalnet make as approved by GE. |
| 12 | 42mm OD X 1.2mm wall thickness |
| 13 | 28mm OD X 0.9mmwall thickness |
| 14 | 22mm OD X 0.9mm wall thickness |
| 15 | 15mm OD X 0.9mmwall thickness |
| 16 | 12mm OD X 0.7mmwall thickness |
| 17 | Supply, installation, testing and commissioning in repair of Gas outlet points/terminal units withmatching probes for Oxygen, Nitrous Oxide, Medical Air 4 Bar/7 Bar, CO2, front loading type, BS type.Complete all as specified and as directed of following- |
| 18 | Oxygen Port. |
| 19 | Vacuum Port. |
| 20 | Supply and fixing in repair LINE ISOLATION VALVES Complete all as specified and as directed for following sizes of valves :-Make:- Matrix/Hospitech service and sales/ Zoloto/ RN/ JSIor equivalent make as approved by GE. |
| 21 | 15 mm valve |
| 22 | 22 mm valve |
| 23 | 28 mm valve |
| 24 | 42mm valve |
| 25 | 54 mm valve |
| 26 | 12mm valve |
| 27 | Supply onlyin repair copper tail pipe for oxygen/nitrous gas including 5/8 Hex-nut, nipple, head connection with KE nipple Complete all as specified and as directed. |
| 28 | Supply only humidyfire bottle including BPC flowmeter for oxygen complete as per sample. |
| 29 | Supply only ward vaccum unit including regulator, gauge for showing negative pressure and 600ml receiver jar complete as per sample. |
| 30 | Supply only receiver Jar for ward vaccum unit 0 - 600 ml complete as per sample. |
| 31 | M&L for one coat of syntheticpaint to med gas pipe linefor oxygen, Nitrious & vaccum with proper colour coading (for oxygen- white colour, forNitrious- Blue colour & for Vaccum- Yellow colour) after cleaning/scrapping of old paint all as specified and as directed. |
| 32 | Cutting the existing gas/vaccum pipe line for supply, insertion of suitable size of tee for pipe of dia 22/15 mm for new point / leakage repair as required all as specified and directed including with all necessary arrangement like soldering/welding etc |
| 33 | Cutting the existing gas/vaccum pipe line for supply, insertion of suitable size of tee for pipe of dia 42/28 mm for new point / leakage repair as required all as specified and directed including with all necessary arrangement like soldering/welding etc. |
| 34 | Supply only pork let outlet valve for oxygen as per sample complete all as directed. |
| 35 | Supply only pork let outlet valve for nitrous as per sample complete all as directed. |
| 36 | Supply only pork let outlet valve for vacuum as per sample complete all as directed. |
| 37 | Supply only adaptor pork letfor oxygen /Nitrous/vaccum as per sample complete all as directed. |
| 38 | Supply onlyin repair Operation theatervacuum unit as per sample Complete all as specified and as directed. |
| 39 | Supply onlyin repair line pressure gauge for control panel of O2/N20 as per sample Complete all as specified and as directed. |
| 40 | Supply onlyin repair bonnet for OR-14 regulator for oxygen/nitrous as per sample Complete all as specified and as directed. |
| 41 | Supply onlyin repair spring for OR-14 regulator for oxygen/nitrous as per sample Complete all as specified and as directed. |
| 42 | Supply only in repair diaphgram OR-14 as per sample Complete all as specified and as directed. |
| 43 | Supply onlyin repair diaphgram carrier as per sample Complete all as specified and as directed. |
| 44 | Supply onlyin repair diaphgram plate as per sample Complete all as specified and as directed. |
| 45 | Supply onlyin repair O-ring (big/small) as per sample Complete all as specified and as directed. |
| 46 | Supply onlyin repair nipple inlet flat as per sample Complete all as specified and as directed. |
| 47 | Supply onlyin repair brass ring for OR-14 as per sample Complete all as specified and as directed. |
| 48 | Supply onlyin repair seat nylon as per sample Complete all as specified and as directed. |
| 49 | Supply onlyin repair safety valve as per sample Complete all as specified and as directed. |
| 50 | Supply onlyin repair outlet Iox -69 as per sample Complete all as specified and as directed. |
| 51 | Supply onlyin repair copper tube connection for non return as per sample Complete all as specified and as directed. |
| 52 | Supply onlyin repair gasket for BPC jar as per sample Complete all as specified and as directed. |
| 53 | Supply onlyin repair gasket for vacuum jar as per sample Complete all as specified and as directed. |
| 54 | Supply onlyin repair HP tubing for oxy/nit/vac as per sample Complete all as specified and as directed. |
| 55 | Supply onlyin repair LP tubing for BPC flow meter as per sample Complete all as specified and as directed. |
| 56 | Supply onlyin repair saddle for copper tubing 12 mm dia as per sample Complete all as specified and as directed. |
| 57 | Supply onlyin repair saddle for copper tubing 15 mm dia as per sample Complete all as specified and as directed. |
| 58 | Supply onlyin repair saddle for copper tubing 22 mm dia as per sample Complete all as specified and as directed. |
| 59 | Supply onlyin repair saddle for copper tubing 28 mm dia as per sample Complete all as specified and as directed. |
| 60 | Supply onlyin repair,PB Amico 02 (Wall Mounted) Outlet with 3/8 BSB thread probe Complete all as specified and as directed. |
| 61 | Supply onlyin repair, PB Amico vacuum (Wall Mounted) Outlet with Hose type probe Complete all as specified and as directed. |
| 62 | Supply onlyin repair, PB Amico AIR (Wall Mounted) Outlet with Hose type probe Complete all as specified and as directed. |
| 63 | Supply onlyin repair, PB Amico N2O (Wall Mounted) Outlet with Hose type probe Complete all as specified and as directed. |
| 64 | Supply onlyin repair, PB AmicoCO2 (Wall Mounted) Outlet with Hose type probe Complete all as specified and as directed. |
| 65 | Supply onlyin repair Oxygen BPC flow meter with Humidifier bottle for bed head panels Complete all as specified and as directed. |
| 66 | Supply onlyin repair Ward vacuum unit with 600 ML receiving jar for bed head panels Complete all as specified and as directed. |
| 67 | Dismantling and opening the motor from Air Compressor systemin existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same in original position. Capacity of motor is 15 HP 3 PH. Complete all as specified and as directed. |
| 68 | Dismantling and opening the motor from Air Compressor systemin existing position for carrying out rewinding work with new super enamelled copper wire of suitable gauge as per existing and heat varnishing complete with all other material required for rewinding, re-assembling and refixing the same in original position. Capacity of motor is 10 HP 3 PH. Complete all as specified and as directed. |
| 69 | Supply only Needle bearing with seal LP for Air Compressor (02Sets) as per sample Complete all as specified and as directed. |
| 70 | Supply only Needle bearing with seal HP forAir Compressor (01Sets) as per sample Complete all as specified and as directed. |
| 71 | Supply only Valve LP with packing set forAir Compressor as per sample complete(02Sets) Complete all as specified and as directed. |
| 72 | Supply only Valve HP with packing setforAir Compressor as per sample complete (01Set) Complete all as specified and as directed. |
| 73 | Supply onlyfilter element for Air Compressor as per sample complete (02 nos) Complete all as specified and as directed. |
| 74 | Supply & fix in repair ,2 gas alarm (Digital type)for for2 Gases Complete all as specified and as directed. |
| 75 | Supply & fix in repair ,3 gas alarm (Digital type)for for2 Gases Complete all as specified and as directed. |
| 76 | Supply & fix in repair ,4 gas alarm (Digital type)for for2 Gases Complete all as specified and as directed. |
| 77 | Supply only pendent outlet valve for for oxygen Complete all as specified and as directed. |
| 78 | Supply only pendent outlet valve for for Nitrous oxide Complete all as specified and as directed. |
| 79 | Supply only pendent outlet valve for vaccum. Complete all as specified and as directed. |
| 80 | Supply only pendent outlet valve for CO2. Complete all as specified and as directed. |
| 81 | Supply only pendent outlet valve for for Air Complete all as specified and as directed. |
| 82 | Supply only Brass non Return valve for oxgen & Nitrious for control pannelas per sample. Complete all as specified and as directed. |
| 83 | Supply only Air pressure controlling Regulator valve whith inlet outlet dia20 mmfor (0 to 10 Bar) Air delivery line Complete all as specified and as directed.Make - JANATICS /Hospitech service and sales or equivalent make as approved by GE. |
| 84 | Supply only Brass Non Return valve, dia 50 mm, suitablefor copper pipe line ofvacuum, air ,oxgen & Nitrious gas as per sample. Complete all as specified and as directed. |
| 85 | Supply only tue up kitfor vaccum pump. Complete all as specified and as directed. |