| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 05-12-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 12-12-2024 |
| Sl. No. | Item Description |
| 1 | Disconnecting,dismantling and taking out the defective/ non functional desert cooler of any description and in any position and any location , strip opening of desert cooler, cleaning servicing oiling & greasing etc of desert cooler taking out and removing unserviceable/defective parts and internal wiring, replacement of unserviceable & damaged parts and internal wiring, reassembling & testing of the desert cooler complete all as specified and directed.Note :- (i) The replacement of defective/ nonfuctional parts shall be measured & paid separatly as ` supply only\" under respective item of schedule A and fixing charges for new items are deemed to be included under quoted rate.(ii) The rate for above items are deemed to included for transportation to & from of vertical pumps/fan motor to workshop as approved by Engr-in-charge for necessary repairs, alignment and testing of pump and motor at workshop & replacement of necessary unserviceable screws/nuts, bolts/washer/packing etc with new one. |
| 2 | Supply only of the following parts for existing desert cooler of any description, any capacity, any make and in any position complete all as specified and directed.Note :- (i) Make of the parts must be same as per existing desert cooler (ii) The cost of fixing and testing of spare parts is deemed to be included under respective item of schedule A here-in-before |
| 3 | 15 mm dia PVC flexible water pipe complete set for one desert cooler |
| 4 | PVC distributor 3 way for 15 mm dia water distribution. |
| 5 | 1.5 sqmm 3 core PVC insulated copper cable round type suitable for 1100 volts grade. |
| 6 | 2.5 sqmm 3 core PVC insulated copper cable round type suitable for 1100 volts grade. |
| 7 | Regulator for three speed motor as per site requirement. |
| 8 | Submersible pump PVC body for desertcooler single phase, 230 volt AC flow rate 1100LPH, Max head 1850 mm Make:- Balaji or equivalent as approved |
| 9 | Desert Cooler evaporation panels (side and back panels) of any description and sizes for different size of desert coolers made to shape and size with using 20 SWG guage PGI sheets as per requirement incl necessary moulding etc to suit the existing desert cooler openings complete all as specified and directedas per site requirment. |
| 10 | Aluminium fan blade (set of three blades) for desert cooler motor of any description suitable for existing motor. |
| 11 | Wood wool pads of required size as apporved (three in each) for desert cooler of any size. |
| 12 | Desert cooler fan motor copper winding of existing make/model/ capacity/sweep, 900 RPM as per site requirement including making connection complete all as specified and directed Make - Crompton. |
| 13 | Desert cooler fan motor copper winding of existing make/model/ capacity/sweep, 1200 RPM as per site requirement including making connection complete all as specified and directed Make - Crompton. |
| 14 | Desert cooler fan motor copper winding of existing make/model/ capacity/sweep 1400 RPM (Exhaust fan kit with fan blade) including making connection complete all as specified and directed Make - Cromption |
| 15 | Chicken wire mess having hexagonal wire mesh (three for each cooler front and both side) 15mm size mesh and 0.5mm dia of wire for supporting to the wood wool pads of existing size suitable for any desert cooler. |
| 16 | Front grills of existing shape and size and made out of 20 SWG PGI sheet suitable for any desert cooler as required on site. |
| 17 | 15mm bore ball brass valves high pressure with polythene float and fly nut complete |
| 18 | 15mm bore Gun metal gate valve with iron wheel head, screwed both end for iron pipe Make NMC/BIR/Leader |
| 19 | PVC connection pipe 15mm size 450mm length complete with PTMT nuts on both ends. |
| 20 | 5A plug top as per requirement, Make : Anchor or equavalent. |
| 21 | 15 A plug top as per requirement, Make : Anchor or equavalent. |
| 22 | Disconnecting,dimanling and taking out the non functional Water Coolers of any description, any capacity toworkshop cleaning , servicing, checking,replacement of unserviceable parts including testing to the entire satisfaction of Engineer - in - Charge complete all as specified and directed.Note :- Nut, bolts, screws are to be replaced and rates are inclusive under quoted rate, Labour for gas charging as required is inclusive under quoted rates . Replacement of new parts shall be measured and paid separately under relevant item of Sch \"A\" as Supply only. |
| 23 | Supply only of the following parts for existing water cooler of any description, any capacity, any make and in any position complete all as specified and directed.Note :- (i) Make of the parts must be same as per existing water cooler (ii) The cost of fixing and testing of spare parts is deemed to be included under schedule A here-in-before |
| 24 | Base tray stainlesssteel for40 ltrs capacity |
| 25 | Base tray stainlesssteel for60 ltrs capacity |
| 26 | Base tray stainlesssteel for150 ltrs capacity |
| 27 | Side cover set of 3 stainless steel for 40/80 ltrs capacity |
| 28 | Side cover set of 3 stainless steel for 60/120 ltrs capacity |
| 29 | Side cover set of 3 stainless steel for 150/150 ltrs capacity |
| 30 | Water Reservior tank with chiller made of stainless steel incl copper tube for 40/80 Ltrs capacity |
| 31 | Water Reservior tank with chiller made of stainless steel incl copper tube for 60/120 Ltrs capacity |
| 32 | Water Reservior tank with chiller made of stainless steel incl copper tube for 150/150 Ltrs capacity |
| 33 | Water tank chiller\"s top cover made of stainless steel for 40/80 ltrs capacity |
| 34 | Water tank chiller\"s top cover made of stainless steel for 60/120 ltrs capacity |
| 35 | Water tank chiller\"s top cover made of stainless steel for 150/150 ltrs capacity |
| 36 | Air cooled condenser with ventury, copper 3 row suitable for existing make and model for 40/80 ltrs capacity |
| 37 | Air cooled condenser with ventury, copper 3 row suitable for existing make and model for 60/120 ltrs capacity |
| 38 | Air cooled condenser with ventury, copper 3 row suitable for existing make and model for 150/150 ltrs capacity |
| 39 | Relay unit currrent type suitable for 40 to 150 Ltr Cap water cooler as per existing make and model. |
| 40 | Relay pin type (Potential type) suitable for 40 to 150 Ltr Capacity water cooler as per existing Make and Model. |
| 41 | Thermostat 220 volts suitable for 40 to 150 Ltr as per existing make and model |
| 42 | Over load protector of existing make suitable for 40 to 150 Ltr water cooler |
| 43 | AC electric condenser motor as per existing make and model suitable for 40 Ltr water Cooler. |
| 44 | AC electric condenser motor as per existing make and model suitable for 60 Ltr water Cooler. |
| 45 | AC electric condenser motor as per existing make and model suitable for 150 Ltr water Cooler. |
| 46 | Brass nipple 15 mm dia for inlet and out let connection of water cooler any type/size incl PVC connection 15 mm dia with brass coupling on both ends |
| 47 | Drain pipe PVC flexible ¼\" dia . |
| 48 | End circle clip for Drainpipe 1/4\" dia |
| 49 | Flexible Wiring kit ofPVC insulated copper condutor cable of existing size. |
| 50 | CP brass push cock 15mm dia (ISI marked) inner/outer threadedas directed |
| 51 | Harmetic sealed unit compresssor of existing make and model suitable for capcity40/80 Ltrs of water cooler incl vaccum testing and filling of refrigerant gas to required pressure is included under relavent item of Sch \"A\"complete all as directed by Engineer - in - Charge. |
| 52 | Harmetic sealed unit compresssor of existing make and model suitable for capcity60/120 Ltrs of water cooler incl vaccum testing and filling of refrigerant gas to required pressure is included under relavent item of Sch \"A\"complete all as directed by Engineer - in - Charge. |
| 53 | Harmetic sealed unit compresssor of existing make and model suitable for capcity150/150 Ltrs of water cooler incl vaccum testing and filling of refrigerant gas to required pressure is included under relavent item of Sch \"A\" complete all as directed by Engineer - in - Charge.Note : The cost of fixing brazing to suction and discharge line and testing of compressor at site is deemed to be included under respective item of schedule \"A\". |
| 54 | Fan blade suitable for 40/80 ltrs capacity |
| 55 | Fan blade suitale for 60/120 ltrs capacity |
| 56 | Fan blade suitable for 150/150 ltr capacity |
| 57 | Disconnecting,dimanling and taking out the non functional Refrigerator of capacity 165 to 340 ltrs of any description, Servicing , checking,replacement of unserviceable parts including testing complete all as specified and directed.Note :- Replacement of new parts and shall be measured and paid separately under relevant item of Sch \"A\" as Supply only. |
| 58 | Supply only of the following new parts for existing refrigerator of any description, any capacity of 165 to 340 ltrs & any make and in any positioncomplete all as specified and directed. |
| 59 | Main door gasket magnetic type |
| 60 | Thermostat switch with knob 230 volt suitable for single door refrigerator |
| 61 | Thermostate switch with knob 230 volts suitable for double door refrigerator of capacity 165 to 360 ltrs |
| 62 | Overload relay suitable for referigerator of capacity 165 to 340 Ltr Capacity as per existing Model. |
| 63 | Freezer Zone door suitable for existing make and Model. |
| 64 | Pin type/screw type bulb Make Philip/bajaj/Crompton |
| 65 | Condensor water drain off tray of pvc same as per existing model complete |
| 66 | Door switch 230 volts |
| 67 | Chiller tray plastic suitable for 165 to 340 Ltr Capacity. |
| 68 | Refrigerator freezer coil suitable for as per existingfor 165 ltr to 230 ltrs capacity |
| 69 | Refrigerator freezer coil suitable for as per existingfor above 230 ltr to 360 ltrs capacity |
| 70 | Bulb holder assembly complete |
| 71 | InnerPUF Insulationfor 165 to 230 ltr capacity |
| 72 | Innter PUF Insulationfor above 230 ltr to 360 ltr capacity |
| 73 | PVC inner cabinet moulded in shape suitable for capacity 165 to 230 ltrs |
| 74 | Condesner coil for 165 to 230 ltrs capacity |
| 75 | Condesner coil for above 230 to 360 ltrs capacity |
| 76 | Fan motor suitable for double door refrigerator as per existing. |
| 77 | Thermostat suitable for referigerator of capacity 165 to 230 ltr as existing |
| 78 | Thermostat suitable for referigerator of capacity above 230 and upto 360 ltr as existing |
| 79 | PCB for 165 to 230 ltrs capacity as per existing Make and Model |
| 80 | PCB for above 230 to 360 ltrs capacity as per existing Make and Model |
| 81 | Timer for double door refrigerator as per existing make. |
| 82 | Capilary suitable for referigerator of Capacity 165 to 360 ltr as per existing |
| 83 | Sealed unit compressor suitable for referigerator of capacity 165 Ltr to 230 Ltr as per existing Make and Model incl vacuum testing and filling of refrigerant gas to the required pressure complete to the entire satisfaction of Engr - in - Charge , Gas charging, brazing to suction and discharge line is included relevant item of Sch \"A\". |
| 84 | Sealed unit compressor suitable for referigerator of capacity above 230 Ltr to 360 Ltr as per existing Make and Model incl vacuum testing and filling of refrigerant gas to the required pressure complete to the entire satisfaction of Engr - in - Charge , Gas charging, brazing to suction and discharge line is included in relevant item of Sch \"A\" . |
| 85 | Vegetable tray of refrigerator suitable for capacity 165 to 360 Ltr Capacity. |
| 86 | Supply of Refrigerant gas (R-134A) in cane complete all as specified and directed. |
| 87 | Supply of Refrigerant gas (R-600A) in cane complete all as specified and directed. |
| 88 | Supply and fixing voltage stablizer electronic typefor automatic operation single phase naturally air cooled, indoor, type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 5.0 KVAcomplete all as specified and directed |
| 89 | Supply and fixing voltage stablizer electronic typefor automatic operation single phase naturally air cooled, indoor type, wall mounted for input variation between 170 V to 250 V with output voltage stablized at 230V with accuracy of + 2.5% and of capacity 4.0 KVA complete all as specified and directed |
| 90 | Taking down old unserviceable PVC cable of any conductor and any core complete all as specified and directed |
| 91 | S&F PVC insulated & sheathed copper round cable 1100 volts of size 4.0 sqmm 3 core incl copper thimble/pin type lugs connecting both side and testing complete all as specified and directed. |
| 92 | All as per item No 10 here-in-before but of Size 4.0 sqmm 4 core |
| 93 | All as per item No 10here-in-before but of Size 4.0 sqmm 5 core |
| 94 | Preventive maintenance & routine servicing of split AC ofany type/size/make /model & capacityup to 3TR in any position / work shop as convenient indoor & out door unit by cleaning of dust from condenser,air filter, cooling coils by pressure pump , liquid line filter/capillary tube /expansion valve, refrigerent inlet /out let pipe by Nitrogen and Ethylene tri chloride(ETC),andchecking of all electrical components and compressor etc.Replacement of minor parts such asnut, bolts, screws, washers, brazing, lugs etc and testing proper cooling all as directed.Note:-(i) Contractor has to provide sufficient manpower minimum 02 Technician and 04 helper for resolving timely complaints.(ii)The replacement of defective / nonfunctional parts except compressors during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging if required, shall be measured and paid separately. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit. |
| 95 | Preventive maintenance & routine servicing of Window type AC ofany type/size/make /model & capacity at any positionincluding cleaning & washing condenser assembly by chemical such as suction air filter & coil, brazing the discharge and suction line andchecking & retightening of all electrical connections.Replacement of minor part such asnut, bolts, screws, washers incl replacment of unserviceable partsof capacity 1.5/2.0 TR of single phase AC etc and testing complete all as specified and directed.NOTE :-(i) The replacement of defective / nonfunctional parts except compressors during servicing shall be measured & paid for separately as “Supply only” under appropriate item of Sch ‘A’ and fixing charges for new items are deemed to be included under quoted rate of this item. (ii) Refrigerant gas for charging if required, shall be measured and paid separately. However, vacuumising and pressure leakage testing with nitrogen (N2), if any required, is deemed to be included under the unit rate quoted by the contractor during one time servicing & preventive maintenance of unit. |
| 96 | Supply only following items ofAir conditioning split/windowtype AC of capacity 1.5/2/3TRof any make/model/ capacity including checking of defects and rectified complete all as specified and directed . |
| 97 | Starting capacitor 80/100 mfd suitable for 240 Volts 50 HZ AC supply. |
| 98 | Supply only in replacement with new Starting capacitor 100/120 mfd suitable for 240 volts 50 HZ AC supply |
| 99 | Supply only in replacement with new Running capacitor of 36 mfd +5/6 mfd suitable for 440 volts 50 HZ ACsupply |
| 100 | Supply only in replacement with new Running capacitor of 45/50/60 + 5/6 mfd suitable for 440 volts 50 HZ AC Supply |
| 101 | Supply only in replacement with new Running capcitor of 10 mfd suitable for 430 volts 50 HZ AC supply |
| 102 | Supply only in replacement with new Running capcitor of 1 to 2.5 mfd suitable for 240 volts 50 HZ AC supply |
| 103 | Supply only in replacement with new Running capcitor of 3 to 4 mfd suitable for 240 volts 50 HZ AC supply |
| 104 | Supply only in replacement with new PVC braded drain pipe of size 15 mm inner dia |
| 105 | Supply only in replacement with new PVC braded drain pipe of size 20 mm inner dia |
| 106 | Supply only in replacement with new PVC braded drain pipe of size 30 mm inner dia |
| 107 | Supply only in replacement with new Electronic sensing unit as per sample (PCB) with hand set suitable for PCB and display unitsuitable for Split AC/Window AC1.5/2.0 TR of capacity, model and make as per existing all as directed. |
| 108 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR inverter type of capacity, model and make as per existing all as directed. |
| 109 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR capacity Non inverter type, model and make as per existing all as directed. |
| 110 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for Split AC 3.0 TR cassete type of any model and make as per existing all as directed. |
| 111 | Supply only in replacement with new Electronic sensing unit (PCB) as per sample with hand set suitable for PCB anddisplay unitsuitable for hot and cool type Split AC 1.5/2 TR of any model and make as per existing all as directed. |
| 112 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 1.5/2TR complete all as specified and directed. |
| 113 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for window type AC 1.5/2TR complete all as specified and directed. |
| 114 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type AC 3TR complete all as specified and directed. |
| 115 | Supply only in replacement with new Air cooled copper condenser coil as per sample suitable for split type Cassete AC 3TR including complete all as specified and directed. |
| 116 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR split AC Single Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 117 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 1.5/2 TR window AC Single Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 118 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Single Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 119 | Supply only in replacement with new Electric fan motor as per sample suitable for out door unit 3 TR Split AC Three Phase complete all as specified and directed at site.Make :- LG/Blue star/ Voltasor as per existing make of AC at site |
| 120 | Supply only in replacement with new capillary tube of size as per sample suitable for split AC 1.5TR/2TR/3TR and window type AC of any make complete all as specified and directed. |
| 121 | Supply only in replacement with new Liquid line copper filter as per sample suitable for 1.5/2 TR split/window AC. |
| 122 | Supply only in replacement with new Liquid line copper filter as per sample suitable 3 TR split AC. |
| 123 | Supply only in replacement with new Over load Relay as per sample suitable for any type split type 1.5/2 TR Capacity. |
| 124 | Supply only in replacement with new Over load Relay as per sample suitable for any type split type 3 TR Capacity. |
| 125 | Supply only in replacement with new Condenser side fan blade as per sample suitable for existing SplittypeAC\"s of Capacity 1.5/2 TR. |
| 126 | Supply only in replacement with new Condenser side fan blade as per sample suitable for existing SplittypeAC\"s of Capacity 3 TR. |
| 127 | Supply only PVC fan blower assembly as per sample for 1.5 /2TR window / split AC\"s any make as existing. |
| 128 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5 /2 TR Capacity as per existing make and model. |
| 129 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TR Capacity as per existing make and model. |
| 130 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 1.5/2 TRcapacity inverter type as per existing make and model. |
| 131 | Supply only in replacement with new Blower motor as per sample suitable for split type AC of 3 TRcapacity inverter type as per existing make and model. |
| 132 | Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 1.5 / 2 TR Capacity. |
| 133 | Supply only in replacement with new Swing Motor suitable for flapper of any type Split AC 3 TR Capacity. |
| 134 | Supply only in replacement with new flapper suitable for Split AC as per sample for capacity 1.5 to 3 TR |
| 135 | Supply only in replacement with new PVC Grills as per sample and for any make window AC. |
| 136 | Supply only in replacement with new Thermostate switch with knob 230 volts for Window AC |
| 137 | Supply only in replacement with new Check valve any dia for upto 3 TR capacity Split AC\"s as per sample. |
| 138 | Supply only in replacement with new Expansion valve complete set as per sample suitable for 1.5 / 2 TR Spllit AC. |
| 139 | Supply only in replacement with new Expansion valve complete set as per sample suitable for 3 TR Spllit AC. |
| 140 | Supply only in replacement with new Ventury as per sample made of thermo-coal insulationsuitable for Window AC . |
| 141 | Supply only in replacement with new Pre-air filter made up of PVC for indoor unit as per sample of split AC suitable for any capacity make and description complete |
| 142 | Supply only in replacement with new Brass service valve of 5/8\" dia with flare unit as per sample for split type AC. |
| 143 | Supply only in replacement with new Brass service valve of 3/8\" dia with flare unit as per sample for split type AC. |
| 144 | Supply only in replacement with new Brass service valve of 1/2\" dia with flare unit as per sample for split type AC. |
| 145 | Supply only in replacement with new Brass service valve of 1/4\" dia with flare unit as per sample for split type AC. |
| 146 | Disconnecting, dismanlting and taking out the functional air conditioner window type of any description any make and in any position 1.5/2.0 TR capacityand reassembling, fixing and testing the dismantled AC in new location / position after making necessary cutting/openingand making good in window frame complete all as specified and directed.Note- (i) The rate for above items are deemed to include for transportation to any distance inside the AF area as appoved by Engr-in-charge(ii) Gas for charging of gas if required shall be measured and paid separatly under appropriate item of schedule `A\". |
| 147 | Disconnecting,dismantling and taking out the functional air conditioner split type of any description, any make, and in any poition single/three phase and reassembling, fixing and testing incl installation of split / window AC in new position/location after making necessary cutting/opening in wall and making good to match with the existing surface complete all as specified and directed Note : (i) The rate for above items are deemed to include for necessary servicing, cleaning and testing of indoor/outdoor unit of AC & replacement of necessary unserviceable screws/nuts/bolts/washer/packing\"s etc with new one, brazing of copper pipe & provn of PVC drain pipe of suitable size & length for split AC, transpotation to any distance inside the AF area as approved by Engr-in-charge.(ii) Gas for charging of gas if required shall be measured and paid seperatly under appropriate item of schedule A |
| 148 | Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 3/8\" bore |
| 149 | Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 5/8\" bore |
| 150 | Supply and fixing in replacement with new copper tubing of special annealed pressure copperof size 1/4\" bore |
| 151 | Supply and fixing in replacement with new copper tubing of special annealed pressure copper of size 1/2\" bore |
| 152 | Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 1.5TR/2TR split AC complete all as specified and directed. |
| 153 | Supply and fixing in replacement with new Evaporator complete indoor unit as per sample body made of PVC with GI base plate suitable for 3 TR split AC complete all as specified and directed . |
| 154 | Supply and fixing in replacement with new Harmetic sealed Reciprocating compressor as per samplecomplete suitable for 1.5 TR Split Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 155 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per samplecomplete all as directed and suitable for 2 TR Split Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 156 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per samplecomplete all as directed and suitable for 3 TR Split AC Single Phase 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\". |
| 157 | Supply and fixing in replacement with newHarmetic sealed Reciprocating compressor as per sample complete all as directed andsuitable for 2 TR Single Phase Window Acs 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 158 | Supply and fixing in replacement with new Rotary compressor as per sample complete and suitable for 1.5 TR Split AC Single phase 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 159 | Supply and fixing in replacement with newRotary compressor as per sample complete all as directed and suitable for 2 TR Split AC Single phase 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 160 | Supply and fixing in replacement with new Rotary compressor as per sample complete all as directed and suitable for 3 TR Split AC Single phase 230 volts of existing make. Vaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" |
| 161 | Supply and fixing in replacement with newRotary compressor as per sample complete all as directedVaccumising and pressure testing is inclusive preventive maintenance of unit under respective item of Sch \"A\" .and suitable for 3 TR Split AC Three phase 230 volts of existing make. |
| 162 | S&Fin replacement with new out door cover at any location and floor made of MS Angle and GI Sheet with proper fixing screw to cover the entire out door unit as per sample , fixed on wall with neccessory grouting MSbolts,washer duly painted and making good of disturbed surfaces, suitable for installing outdoor unit of 1.5/2.0/3.0 TR AC complete all as specified and directed. |
| 163 | Supply and fixing in replacement with new Single pole and neutral enclosure with a two pin and earth plug and socket complete with one single pole MCB. |
| 164 | S & F in replacement with new Triple pole and earth encolsure with a three pin and earth plug with socket complete with one triple pole MCB 32 Amps. |
| 165 | Supply and fixing in replacement with new 240V, 10 KA \"B\" curve miniature circuit breaker (MCB) of single poles and current carrying capacity 5 to 32 AMP, in the MCB DB Complete with connection testing and commissioning. |
| 166 | Supply and fixing in replacement with new SPN 40 to 63 amp rating 240V, 10KA \"C\" curve miniature circuit breaker (MCB) and current carrying capacity in the MCB DB complete with connection testing and commissioning. |
| 167 | Supply and fixing in replacement with new TPN / FP 32 Amp 415V 10KA \"B\" curve miniature circuit breaker (MCB)and current carrying capacity in the DB complete with connection testing and commissioning. |
| 168 | Supply and fixing in replacement with new power contactor MNX-12 of rating 12 amps four pole suitable for 415 volts for AC. |
| 169 | S&F in replacement with new contactor MNX18 Amp rating 18 Amps suitable for 220 Volts with 1 NO+1NC auxilary contactscomplete all as specified and directed. |
| 170 | S&F in replacement with new contactor MNX 40 Amp rating 40 Amps suitable for 220 Volts with 1 NO+1NC auxilary contactscomplete all as specified and directed |
| 171 | M & L necessary tools for finding leakage in condenser coil and rectify defects including welding/brazing as necessary by arranging N2 gas for checking and mutein gas for welding etc all as directed and testing for satisfactory operation of window/split type AC complete all as specified and directed. |
| 172 | S&F inin replacement with new electronic timer including testing time range from 3 seconds to 120 seconds suitable for 240/415 volts 50 HZcomplete all as specified and directed |
| 173 | S & F in repair Voltage Monitor three phase protection device for three phase system having protection against High, Low Voltage , Single Phasing and Reverse phase sequence as per sample Make : Voltas or equavalent. |
| 174 | Repair / Maint of PCB of any type AC as per Sample suitable for 1.5 / 2/ 3 TR split / window AC complete all as specified and directed by Engr - in - Charge. |