Power Boards / Undertakings / PSU Closing in 0 days TDR #46143991

Tender For Vi Work At Choyimadamunder Es-Kuttiyadi[Cw-6629-202425-42]

Issued by Boards / Undertakings / PSU · vadakara, Kerala
Tender Value
8.15 Lakhs
Estimated cost
Bid Submission
26 Nov 2024
0 days left
EMD
20400
Bank guarantee accepted
Document Fee
2006
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
vadakara → Kerala
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For VI WORK AT CHOYIMADAMUNDER ES-KUTTIYADI[CW-6629-202425-42]- 1 Providing Strut using LT PSCpole incl. digging & backfilling pit. 2 Loading LT PSC pole fromthe stacking place andunloading the same at worksite (transport by vehicle). 3 Providing Fly stay for LTpole using LT PSC pole incl.digging & back filling pit. 4 Providing Stay for LT polesincl. digging & back fillingPit. 5 Installation of Insulationpiercing connector for mainto service line main :16-95sqmm, Tap 16-95 sqmm 6 Erection of Anchor clamp /dead end clamp for LT ABCof any size 7 Erection of suspension clampfor LT ABC of any size 8 Transporting LT ABC byhired vehicle to a distance upto 5 km and carring up to 2drum including loading andun loading using crane 9 Stringing of 1.1 kV Aerialbunched cable of size 3 x 70+ 1 x 16+1x 50 sqmm withbare/insulated Messengerthrough existing poles 10 Dismantling (withoutdamage) one km LT 3ph 4wire OH line, cross arms,insulators and stacking theconductors in rolls. 11 Dismantling (withoutdamage) one km LT Sph 2wire OH line, cross arms,insulators and stacking theconductors in rolls. 12 Fitting one No. Section fuseon LT line with droppingcables, crimping sockets,connecting with bolt&nut etc. 13 Erection of LT 2 waydistribution box on existingcross arm giving connectionincl. cable and earthconnection (excludingEarthing). 14 Providing concrete muffing(0.45x0.45x1.5m) inclusiveof cost of all material (as perSpecification). 15 Fitting one Additional75x40mm, 1.8m Channelcross arm in existing singlepole incl. conveyance ofMaterials. 16 Fitting and providing one HTStay for 11kV pole incl.digging & back filling pit. 17 Drilling hole of various sizeson existing Channel/CrossArm. 18 Fitting one additional Fuseunit and giving connectionfrom Transformer to fuse andDB to LT OH line. 19 Providing Transformerfencing , using 50x50x6mmAngle iron, 40 x 6 mm MSflat and 8 mm MS rod asspecified, incl cost of transportation & foundation 20 Providing yard metalling with6mm & 40mm thick bluemetal as specified afterconstructing a curb wall. 21 Providing one Earth usingearth pipe incl. digging &backfilling pit and supply ofcharcoal, salt, sand etc. 22 Fitting one Additional2.4m/3m Channel cross arm(100x50x6mm), in existing11kV DP incl. conveyance ofMaterials. 23 Transporting poles by hiredvehicle to a distance upto5km and carrying upto 4poles excluding loading &Unloading. 24 Stringing of 11 kV Aerialbunched cable of size 3 x 120+ 1 x 95 sqmm withbare/insulated Messengerthrough existing poles 25 Fiting One no MVT onexisting cross arm including 2nos end termination (for Onephase) of any rating for 11 kVAB Cable 26 Fiting One no MVT onexisting cross arm excludingtermination work (for Onephase) of any rating for 11 kVAB Cable 27 Erection of Anchor clamp /dead end clamp for 11kVABC of any size 28 Erection of suspension clampfor 11KV ABC of any size 29 Dismantling and reconnecting3ph service connection fromthe OH line incl. loweringdown the WP portion. 30 Loading HT PSC pole fromthe stacking place andunloading the same at worksite (transport by vehicle). 31 Fitting and erecting one HTPSC Pole in position incl.fitting cross arm, digging &back filling pit, drawing earthLeads. 32 Dismantling and reconnectingSph service connection fromthe OH line incl. loweringdown the WP portion 33 Transferring LT Sph 2/3 wireOH line to newly erectedHT/LT pole and refitting allitems to the new pole. 34 Transferring LT 3ph 4/5 wireOH line to newly erectedHT/LT pole and refitting allitems to the new pole. 35 Insertion of one LT PSC polein existing 3ph OH line incl.digging & back filling pit,fitting cross arm, insulator,binding etc. 36 Erecting one LT PSC Pole inposition incl. digging & backfilling pit. 37 Dismantling one damaged LTPSC/RCC pole afterdisconnecting stays, strut etc.and stacking the same 38 Dismantling (without damage) one LT PSC/RCCpole after disconnecting stays,strut etc. and stacking theSame. 39 Installation of Insulationpiercing connector for mainto service line main :16-95sqmm, Tap : 4-35 sqmm 40 Installing One No. 4 waySatellite Connector of sizeMain :16 to 95, Tap:4 to 35Sq.mm to the LT AB cable ofStandard size 41 Erecting one 100kVATransformer to existing DPand giving connections, incl.loading & unloading,excluding transportation. 42 Transporting Transformers byhired vehicle upto 5km andupto 2 No. of 63 to 250kVATransformers / RMUsexcluding loading &Unloading. 43 Installing one DTR Meterwith box on existing polesand giving the completeconnections incl. conveyanceof materials. 44 Fitting and erecting one HTDP using PSC pole inposition incl. fitting 2 channelcross arms, digging & backfilling pit, drawing earthLeads. 45 Fitting 5 channel cross arms,AB switch, DO fuse, LA, HT& LT connections on existingDP, 3 LT fuses. 46 Fitting one set (3No.) 11kVLA and giving connectionsexcluding earthing.

BOQ

Name of Work:- - VI WORK AT CHOYIMADAMUNDER ES-KUTTIYADI[CW-6629-202425-42]
Sl. No. Item Description
1Providing Strut using LT PSCpole incl. digging & backfilling pit.
2Loading LT PSC pole fromthe stacking place andunloading the same at worksite (transport by vehicle).
3Providing Fly stay for LTpole using LT PSC pole incl.digging & back filling pit.
4Providing Stay for LT polesincl. digging & back fillingPit.
5Installation of Insulationpiercing connector for mainto service line main :16-95sqmm, Tap 16-95 sqmm
6Erection of Anchor clamp /dead end clamp for LT ABCof any size
7Erection of suspension clampfor LT ABC of any size
8Transporting LT ABC byhired vehicle to a distance upto 5 km and carring up to 2drum including loading andun loading using crane
9Stringing of 1.1 kV Aerialbunched cable of size 3 x 70+ 1 x 16+1x 50 sqmm withbare/insulated Messengerthrough existing poles
10Dismantling (withoutdamage) one km LT 3ph 4wire OH line, cross arms,insulators and stacking theconductors in rolls.
11Dismantling (withoutdamage) one km LT Sph 2wire OH line, cross arms,insulators and stacking theconductors in rolls.
12Fitting one No. Section fuseon LT line with droppingcables, crimping sockets,connecting with bolt&nut etc.
13Erection of LT 2 waydistribution box on existingcross arm giving connectionincl. cable and earthconnection (excludingEarthing).
14Providing concrete muffing(0.45x0.45x1.5m) inclusiveof cost of all material (as perSpecification).
15Fitting one Additional75x40mm, 1.8m Channelcross arm in existing singlepole incl. conveyance ofMaterials.
16Fitting and providing one HTStay for 11kV pole incl.digging & back filling pit.
17Drilling hole of various sizeson existing Channel/CrossArm.
18Fitting one additional Fuseunit and giving connectionfrom Transformer to fuse andDB to LT OH line.
19Providing Transformerfencing , using 50x50x6mmAngle iron, 40 x 6 mm MSflat and 8 mm MS rod asspecified, incl cost of transportation & foundation
20Providing yard metalling with6mm & 40mm thick bluemetal as specified afterconstructing a curb wall.
21Providing one Earth usingearth pipe incl. digging &backfilling pit and supply ofcharcoal, salt, sand etc.
22Fitting one Additional2.4m/3m Channel cross arm(100x50x6mm), in existing11kV DP incl. conveyance ofMaterials.
23Transporting poles by hiredvehicle to a distance upto5km and carrying upto 4poles excluding loading &Unloading.
24Stringing of 11 kV Aerialbunched cable of size 3 x 120+ 1 x 95 sqmm withbare/insulated Messengerthrough existing poles
25Fiting One no MVT onexisting cross arm including 2nos end termination (for Onephase) of any rating for 11 kVAB Cable
26Fiting One no MVT onexisting cross arm excludingtermination work (for Onephase) of any rating for 11 kVAB Cable
27Erection of Anchor clamp /dead end clamp for 11kVABC of any size
28Erection of suspension clampfor 11KV ABC of any size
29Dismantling and reconnecting3ph service connection fromthe OH line incl. loweringdown the WP portion.
30Loading HT PSC pole fromthe stacking place andunloading the same at worksite (transport by vehicle).
31Fitting and erecting one HTPSC Pole in position incl.fitting cross arm, digging &back filling pit, drawing earthLeads.
32Dismantling and reconnectingSph service connection fromthe OH line incl. loweringdown the WP portion
33Transferring LT Sph 2/3 wireOH line to newly erectedHT/LT pole and refitting allitems to the new pole.
34Transferring LT 3ph 4/5 wireOH line to newly erectedHT/LT pole and refitting allitems to the new pole.
35Insertion of one LT PSC polein existing 3ph OH line incl.digging & back filling pit,fitting cross arm, insulator,binding etc.
36Erecting one LT PSC Pole inposition incl. digging & backfilling pit.
37Dismantling one damaged LTPSC/RCC pole afterdisconnecting stays, strut etc.and stacking the same
38Dismantling (without damage) one LT PSC/RCCpole after disconnecting stays,strut etc. and stacking theSame.
39Installation of Insulationpiercing connector for mainto service line main :16-95sqmm, Tap : 4-35 sqmm
40Installing One No. 4 waySatellite Connector of sizeMain :16 to 95, Tap:4 to 35Sq.mm to the LT AB cable ofStandard size
41Erecting one 100kVATransformer to existing DPand giving connections, incl.loading & unloading,excluding transportation.
42Transporting Transformers byhired vehicle upto 5km andupto 2 No. of 63 to 250kVATransformers / RMUsexcluding loading &Unloading.
43Installing one DTR Meterwith box on existing polesand giving the completeconnections incl. conveyanceof materials.
44Fitting and erecting one HTDP using PSC pole inposition incl. fitting 2 channelcross arms, digging & backfilling pit, drawing earthLeads.
45Fitting 5 channel cross arms,AB switch, DO fuse, LA, HT& LT connections on existingDP, 3 LT fuses.
46Fitting one set (3No.) 11kVLA and giving connectionsexcluding earthing.

AI Tender Summary

OUR REF NO 46143991
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 8.15 Lakhs
LAST DATE 26-11-2024
Authority
Authority Name Kerala State Electricity Board
Work Description Tender For VI WORK AT CHOYIMADAMUNDER ES-KUTTIYADI[CW-6629-202425-42]- 1 Providing Strut using LT PSCpole incl. digging & backfilling pit. 2 Loading LT PSC pole fromthe stacking place andunloading the same at worksite (transport by vehicle). 3 Providing Fly stay for LTpole using LT PSC pole incl.digging & back filling pit. 4 Providing Stay for LT polesincl. digging & back fillingPit. 5 Installation of Insulationpiercing connector for mainto service line main :16-95sqmm, Tap 16-95 sqmm 6 Erection of Anchor clamp /dead end clamp for LT ABCof any size 7 Erection of suspension clampfor LT ABC of any size 8 Transporting LT ABC byhired vehicle to a distance upto 5 km and carring up to 2drum including loading andun loading using crane 9 Stringing of 1.1 kV Aerialbunched cable of size 3 x 70+ 1 x 16+1x 50 sqmm withbare/insulated Messengerthrough existing poles 10 Dismantling (withoutdamage) one km LT 3ph 4wire OH line, cross arms,insulators and stacking theconductors in rolls. 11 Dismantling (withoutdamage) one km LT Sph 2wire OH line, cross arms,insulators and stacking theconductors in rolls. 12 Fitting one No. Section fuseon LT line with droppingcables, crimping sockets,connecting with bolt&nut etc. 13 Erection of LT 2 waydistribution box on existingcross arm giving connectionincl. cable and earthconnection (excludingEarthing). 14 Providing concrete muffing(0.45x0.45x1.5m) inclusiveof cost of all material (as perSpecification). 15 Fitting one Additional75x40mm, 1.8m Channelcross arm in existing singlepole incl. conveyance ofMaterials. 16 Fitting and providing one HTStay for 11kV pole incl.digging & back filling pit. 17 Drilling hole of various sizeson existing Channel/CrossArm. 18 Fitting one additional Fuseunit and giving connectionfrom Transformer to fuse andDB to LT OH line. 19 Providing Transformerfencing , using 50x50x6mmAngle iron, 40 x 6 mm MSflat and 8 mm MS rod asspecified, incl cost of transportation & foundation 20 Providing yard metalling with6mm & 40mm thick bluemetal as specified afterconstructing a curb wall. 21 Providing one Earth usingearth pipe incl. digging &backfilling pit and supply ofcharcoal, salt, sand etc. 22 Fitting one Additional2.4m/3m Channel cross arm(100x50x6mm), in existing11kV DP incl. conveyance ofMaterials. 23 Transporting poles by hiredvehicle to a distance upto5km and carrying upto 4poles excluding loading &Unloading. 24 Stringing of 11 kV Aerialbunched cable of size 3 x 120+ 1 x 95 sqmm withbare/insulated Messengerthrough existing poles 25 Fiting One no MVT onexisting cross arm including 2nos end termination (for Onephase) of any rating for 11 kVAB Cable 26 Fiting One no MVT onexisting cross arm excludingtermination work (for Onephase) of any rating for 11 kVAB Cable 27 Erection of Anchor clamp /dead end clamp for 11kVABC of any size 28 Erection of suspension clampfor 11KV ABC of any size 29 Dismantling and reconnecting3ph service connection fromthe OH line incl. loweringdown the WP portion. 30 Loading HT PSC pole fromthe stacking place andunloading the same at worksite (transport by vehicle). 31 Fitting and erecting one HTPSC Pole in position incl.fitting cross arm, digging &back filling pit, drawing earthLeads. 32 Dismantling and reconnectingSph service connection fromthe OH line incl. loweringdown the WP portion 33 Transferring LT Sph 2/3 wireOH line to newly erectedHT/LT pole and refitting allitems to the new pole. 34 Transferring LT 3ph 4/5 wireOH line to newly erectedHT/LT pole and refitting allitems to the new pole. 35 Insertion of one LT PSC polein existing 3ph OH line incl.digging & back filling pit,fitting cross arm, insulator,binding etc. 36 Erecting one LT PSC Pole inposition incl. digging & backfilling pit. 37 Dismantling one damaged LTPSC/RCC pole afterdisconnecting stays, strut etc.and stacking the same 38 Dismantling (without damage) one LT PSC/RCCpole after disconnecting stays,strut etc. and stacking theSame. 39 Installation of Insulationpiercing connector for mainto service line main :16-95sqmm, Tap : 4-35 sqmm 40 Installing One No. 4 waySatellite Connector of sizeMain :16 to 95, Tap:4 to 35Sq.mm to the LT AB cable ofStandard size 41 Erecting one 100kVATransformer to existing DPand giving connections, incl.loading & unloading,excluding transportation. 42 Transporting Transformers byhired vehicle upto 5km andupto 2 No. of 63 to 250kVATransformers / RMUsexcluding loading &Unloading. 43 Installing one DTR Meterwith box on existing polesand giving the completeconnections incl. conveyanceof materials. 44 Fitting and erecting one HTDP using PSC pole inposition incl. fitting 2 channelcross arms, digging & backfilling pit, drawing earthLeads. 45 Fitting 5 channel cross arms,AB switch, DO fuse, LA, HT& LT connections on existingDP, 3 LT fuses. 46 Fitting one set (3No.) 11kVLA and giving connectionsexcluding earthing.
Basic Detail
Tender No e-Tender/01/24-25/dtd12-11-24
Bidding Type Tender
Location
City vadakara
State Kerala
Key Dates
Publish Date 12 Nov 2024
Submission Date 26 Nov 2024
Open Date 28 Nov 2024
Finance
Tender Value 8.15 Lakhs
Tender Fee 2006
EMD 20400
Exemption Not Available
Document List
BOQ_1102810.xls
Biddocument.pdf
Tendernotice_1.pdf
a7ae93e1-1607-495a-8b4c-ac2fe93f78ba.html

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 12, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 28, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_1102810.xls

pdf

Biddocument.pdf

pdf

Tendernotice_1.pdf

html

a7ae93e1-1607-495a-8b4c-ac2fe93f78ba.html

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders