| 1 | Supply and fixing in replacement of LED street light fitting 90 Watts, IP 66, having pressure die cast aluminium alloy housing with heat resistant toughned glass with individual peanutLED lenses and Driver shall be IP-66for water protection, having surge protection device 10 KV, including making connectionscomplete all as specified and directed. Make: Havells Cat Ref -ENDURASUNDOWNSL90 WLED765PASYBOTG/Orient Cat No :LSFS-090-C/Cromption RAPTOR PRO 90W |
| 2 | Supply and fixing in replacement of LED street light fitting 60 Watts, IP 66, having pressure die cast alumnium alloy housing with heat resistant with individualpeanut LED lenses and Driver shall be IP-66 for water protection, including surge protection device 10 KV including making connectionscomplete all as specified and directed. Make: Havells Cat Ref :- ENDURASUNDOWNSL45WLED765PASYBOPC/Orient Cat No: LSFS-060-C//Cromption RAPTOR PRO 60W |
| 3 | Supply and fixing in replacement of LED flood light fitting 120 Watts, IP 66, having pressure die cast alumn alloy housing with heat resistant toughned glass with individual LED lenses, having surge protection device 10 Kv and Driver shall be IP-67 for water protection, including making connections complete all as specified and directed. Make: Havells Cat Ref JETAIRISFL120WLED757APWBLTG/Orient Cat No :LFSMP-120-C/Cromption Rover Plus 120 W |
| 4 | Excavating in trenches not exc. 1.5m wide and not exc. 1.5m in depth for foundation etc or for laying for cables etc not exc 10 sqm on plan and not exc 1.5m in depth and getting out in any type of soil including removal of sand, bricks/PCC covers laid for cable proection complete all as specified and directed. |
| 5 | Returning, filling in, trenches including spreading, levelling, watering and well ramming in layers not exc. 25cm in any type of soil complete all as specified and directed. |
| 6 | Removing surplus excavated material n.exc 50m and depositing where directed at a level n.exc 1.5m above the starting point complete all as specified and directed. |
| 7 | Supply and laying in replacement of brick, double walled corrugated (DWC) HDPE duct pipe, 6 mtr length with socket, rubber ring ectconforming to IS 16205 Pt -24 of approved color complete with fittings for cable protectionofsize 50mm outer dia and 38 mm inner dia complete all as specified and directed. |
| 8 | S&L XLPE LT UG cable PVC insulated, beddedarmoured heavy duty electric cable 1100 volts grade with aluminum conductor of of cable 16 Sqmm 4 Core, including taking down the unserviceable UG cable complete all as specified and directed. |
| 9 | Supply and fixing in replacement thermoplastic polystyrene /polycarbonate enclosurebus bar chamber of cap aluminium busbar 100 Amps of out side dimension 300X200X105 mm, shock proof, vermin proof and dust proof complete with04 Nos with colour coded heat shrinkable sleeves and shall be mounted on F class insulators of capacity 100 amps with 01 No 20Amp SPN MCB including 02 Nos non metalic clamps and GI nut bolts and washers of suitable size and fixed on pole/wallincluding taking down old unsv complete all as specified and directed. |
| 10 | M & L for locating and repairing LT feederfaults ( OH lines or UG cables) such as short circuiting, snapping of conductors, phase/neutral loss in UG cables etc and making the defective circuit serviceable in all respects complete all as specified and directed. Note :- (a). Repairing offault in one circuit , irrespective of any no of street lights/poles/junction boxes etc ,at any location shall be treated as one job only. (b). Earth work, if required, shall be measured and paid separately. (c). All type of T & P ,PVC insulation tapes, minor nuts/bolts/washers etc requiredshall be provided by the contractor without any extra cost to department. (d) Any loosened/broken overhead conductor shall be restringed/repaired to make the system functional in all respects & unit rate quoted shall be deemed to include the cost of the same. |
| 11 | M & L for disconnecting of burnt/damaged cables from panels/junction boxes etc , cutting out the burnt out ends , making new end joints by supply and fixing new aluminium lugs/insulation tapes etc and reconnecting using new nuts/bolts/washer etc and restoring three phase and neutral in the junction boxcomplete all as directedfor the 10/16/25 sqmm 2/3.5/4 core size of LT underground armoured cables complete all as specified and directed. Note - Earth work required for extending the incoming/outgoing cable in junction box/panel board etc shall be deemed to be included in the unit rate quoted. |
| 12 | Supply Laying /fixing in replacement 1100 volts grade heavy duty PVC insulated aluminium conductor, bedded unarmoured cable of size 4 Sqmm 2 core fixed on wall/floor/polescomplete all as specified and directed. |
| 13 | Supply and fixing in replacment of natureswitch complete with timer( Swadeep), contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosure of three phase integrated models of capacity 8 KW to 10KW complete all as specified and directed. (Make-Swadeep Cat Part No Sugam-66-8kW3P/ABB/Siemens) |
| 14 | Supply and fixing in replacment of natureswitch complete with timer( Swadeep), contactor, relays and suitable rating MCBs for incoming and out going in built in suitable IP 66 enclosureof single phase integrated models of capacity 8 KW to 10 KW, complete all as specified and directed. (Make-Swadeep Cat Part No Sugam-66-8kW1P/ABB/Siemens) |
| 15 | Material and labour forDismantling concrete poles/ struts, any size complete all as specified and directed. |
| 16 | Supply, installation, testing and commissioning in replacement of 12 Mtr High mast system with solar LED light and accessories, Mast having hot top dip galvanised inside and outside in single dip with bottom 360mm and top 150mm and 3mm thick without any circumperential welding including accessories for high mast with led frame of 40 NB ERW class-B-MS pipe having suitable arrangement for 6 luminaries.Supply of 06 Nos 24mm dia, 850mm long foundation bolts manufactured from special steel along with nuts, washers anchor plates and templates including earthwork 2.5mX2.5mX1.5m returning filling , PCC 1:4:8 approx 0.75 Cum, RCC 1:2:4 approx 3 Cum steel TMT bars approx 125 Kg anchor plate 8mm square with holes, required for making foundation as per maufacturer instruction and drawing and as directed at site. Lithium based Energy Efficient integrated Solar street lights of 60 Watt - 06 Nos in Single FRP Body with duly polylurethane coating (white color), Luminous Flux 9000 lm, encases with Monocrystalline solar PV Panel135W (Mono-crystalline of 64/66Wp, lithium battery 11.1/12.8V, 78 AH with inbuilt BMS, IP67, high brightness W-LED160-180lm/watt) lamp with Aluminium reflector for better light distribution, CRI>70, Colour Tempeture 5700K-6500K micro controller based charge controller curm driver automatic dimming function (first four hours at full brightness & rest of the time at lower light level with PIR Motion sensor), dust to dawn operation, suitable to working temperature ;-30C to +65C, weight more than 22-25Kg with adjustable MS clap suitable for high mast pole complete all as specified and directed.Protection : short circuit over load reverse plolarity and battery protections. firm should provide Vital parameters test report from NABL accredited lab and should be of made in India CE & ROHS compliant. |