Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #46133733

Tender For Maintenance To Air-Conditioning, Water Coolers And Allied E/M Services At Aob Rambilli.

Issued by Statutory Bodies & Commissions/Committees · rambilli, Andhra Pradesh
Tender Value
13.72 Lakhs
Estimated cost
Bid Submission
09 Dec 2024
0 days left
EMD
27400
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
rambilli → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Maintenance To Air-Conditioning, Water Coolers And Allied E/M Services At Aob Rambilli.

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 02-Dec-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 09-Dec-2024

BOQ

Name of Work: Maintenance to Air conditioning,water coolers and allied E/M serviced at AOB Rambilli
Sl. No. Item Description
1Servicing/repairing of the water coolers of capacity40/40, 120/80 ltr & 120/150 ltr from its existing position and refixing of the same after repairing including/cleaning filter removing internal dust by using air blower and vacuum cleaner, oiling, greasing wherever required including checking / testing after completion all as specified and as directed.Note : Unserviceable/defective items which are required to be replaced shall be measured and paid separately.
2All asitem No 1.00 here-in -before but for Split type AC 1.5 ton/2 ton capacity.
3All asitem No 1.00 here-in -before but for Refrigerator 165/310 ltr capacity.
4All asitem No 1.00 here-in -before but for Deep Freezer.
5Finding the leakage in refrigerant system by nitrogen pressure test etc and rectifying the leakage by brazing,welding including installation and complete testing of the Water cooler of capacity 40/40 ltr, 120/80 ltr & 120/150 ltr all as specified and directed.Note: (i)The necessary nitrogen required for leak test deemed to be included in the quoted rates. (ii) The refrigerant gas reqd will be paid under relevant item of BOQ.
6All asitem No 5.00 here-in -before but for Split type AC 1.5 ton/2 ton capacity
7All asitem No5.00 here-in -before but for Refrigerator 165/310 ltr capacity
8All asitem No5.00 here-in -before but for Deep Freezer
9All asitem No5.00 here-in -before but forpackage type Ac plant of 4.8 TR of Hitachi make ofmodel RAS-6.0HNBRQ
10All asitem No6.00 here-in -before but forpackage type Ac plant of 5.5TR
11M&L for Charging of refrigerant gas (R-22/134A/ HCFC/R407/R404 etc ) to existingWindow AC/ Split AC /Deep Freezer/Refrigerator/Package type AC of any description, any make & in any position to makeup required pressure complete all as directed.
12M&L for replacement of the following parts/items of split/window type AC 1.5 ton / 2.0 ton capacity,package AC 4.8 to 5.5 TR, water cooler 80 ltr / 150 ltr capacity, refrigerator 165 ltr / 310 ltr capacity, and desert coolers etc complete all as specified and as directed.
13Starting capacitor of 80/100 mfd capacity Make: Asian/Keltern/Unistar/EPSCO/Keal
14Starting capacitor of 100/120 mfd capacity
15Running capacitor of 4.5 MFD capacity
16Running capacitor of 50 MFDcapacity
17Starting capacitor of capacity 10 MFD/20MFD
18Running capacitorof 4 MFD.
19Thermostat switch for water cooler Make : Renutral/Shriram/Indfoss
20Thermostat switch for AC 1.5 ton/2.0 ton capacity, Split/window type Make : Renutral/Shriram/Indfoss
21Thermostat switchfor Refrigerator Make : Renutral/Shriram/Indfoss
22Wiring kit for water cooler
23wiring kit for window type / split type AC
24PVC air filter for split AC
25PCB for Cooling Only 2 TR Split Ac as per existing make
26Brass service valve for split typeA/C of size5/8” or 3/8\"\" or 11/8\" dia service valve all as approved (Make : CAM)
27Refrigerator Freezer coil & freezer coil type/roll bound type completesuitable for 165 ltr. to 230 ltr. capacity
28Brass Nipple 15 mm dia for inlet and out let connection of water cooler
29Drain Pipe PVC flexible 1¼” dia with one end circle clip
30CP brass Push cock, 15 mm. Dia.
31M&L Chemial servicing of 5.5 TR condenser unit by descaling agent diluted HCL for outdoor units (condensers) and filter cleaning for indoor ductable/split units of the same complete all as specified and directed by Engr-in-Charge.
32All asitem No 31.00 here-in -before but for 4.8 TR Condenser unit
33M&L for replacement of 3 core flexible copper cable of size 40/0.0076 with thimble etc complete all as specified and as directed.
34S&F in replacement plug top 3, pin 5 Amp complete all as specified
35S&F in replacemen plug top 3, pin 15 Amp complete all as specified
36M&L for replacement of condenser unit of 2 TR split type AC unit including necessary brazing, welding complete all as specified and directed by Engr-in-Charge.Note:- The Compressor required shall be paid under relevant item of Schedule \"A\".
37M&L for replacement of indoor evaporator coil unit of 2 TR split type AC unit incl necessary brazing, welding complete all as specified and directed by Engr-in-Charge.
38M&L for replacement of burnt compressor of water cooler 80-150 ltr per hours cooling capacity. including dismantling the unserviceable burnt afterdisconnecting suction/discharge side copper tube bolts rubber pads and washers connecting copper tubing by welding blazing nut flaring and repairing of gas leakage if any completeall as specified and as directed.
39All asitem No 38.00 here-in -before but for Split type AC 2.0/1.5 ton capacity
40All asitem No 38.00 here-in -before but for refrigerator 165 ltr capacity
41All asitem No 38.00 here-in -before but for refrigerator 310 ltr capacity
42All asitem No 38.00 here-in -before but for deep Freezer 200 to 315 ltr capacity
43M&L for replacement of blower fan motor of existing size and capacity in cooling unit of split type AC capacity 2.0/1.5 TR complete all as specified and as directed.
44M&L for replacement of Condensor fan motor of existing size and capacity in outdoor unit of split type AC capacity 2.0/1.5 TR complete all as specified and as directed .
45M&L for replacement of copper tube of size 1/4\" or 3/5\"\" dia for cooling unit to condensing unit for split ACs complete all as specified and as directed.
46All asitem No 45.00 here-in -before butof size 1/2\"\" or 5/8\" dia
47M&L for replacement ofinsulation for copper tube of size 1/4\" or 1/2\" or 3/8\" or 5/8\" dia for cooling unit to condensing unit for split Acs as per existing complete all as specified and as directed.
48M&L for writing/making SL, SM, MES Nos with black/white paint with stencil on indoor and outdoor unit of split Acs window type Acs water cooler desert coolers, stabilizers of any make and anycapacity all as specified and as directed.
49M&L for replacement of PCB ,sensor display unit of 1.5/2 TR inverter type split type AC unit incl necessary joining, welding with necessary bolt & nuts complete all as specified and directed by Engr-in-Charge.
50M&L for replacement in repairs of oscillation motor of 2 TR split type AC unit incl necessary joining, welding with necessary bolt & nuts complete all as specified and directed by Engr-in-Charge.
51M&L for replacement of metal clad socket outlet 3 pin of capacity 20 Amps240V complete all as specified and as directed.
52M&L for replacement of metal clad plug top of capacity 20 Amps, 240Vcomplete all as specified and as directed.
53M&L for replacement of float valve 15mm bore of brass with L type nipple & polythene float valve complete all as specified and as directed.
54M&L for replacementCRCA outer housing/body parts of outdoor unit of 2 TR split type AC unit including necessary joining, welding with bolt & nuts complete all as specified and directed by Engr-in-Charge.
55M&L for replacement outer housing body parts of indoor unit of 2 TR split type AC unit incl necessary joining, welding with necessary bolt & nuts complete all as specified and directed by Engr-in-Charge.
56Servicing/repairing of 11 TR air cooled ductable split air conditioner unit of capacity 5.5 TR with scroll compressor from its existing position and refixing of the same after repairing including/cleaning filter removing internal dust by using air blower and vacuum cleaner, oiling, greasing wherever required including checking / testing after completion all as specified and as directed.Note : (i) Unserviceable/defective items which is required to be replaced shall be measured and paid separately.
57All asitem No 56.00 here-in -before but of 4.8 TR Condenser unit
58M&L forPCB of outdoor unit suitable for 4.8TR capacity for existing AC make Hitachi model No RAS-6.0HNBRQcomplete all as specified and as directed.
59M&L for suitable PCB for 5.5TR capacity existing AC make Bluestar complete all as specified and as directed.
60M&L for Volume control dampers/duct dampers with operating handlesuitable for 09 to 11 TR capacity for supply air duct branches complete all as specified and as directed.
61M&L for canvas connection for ductable units complete all as specified and as directed.
62Supply , assembly and erection of GI sheet with TDF flange rectangular/square duct made out of \"L\" shaped hollow profile, duly factory boxed, includingall accessories such as Corner, Cleat, Carriage bolt, Gasket and appropriate sealant on longitudinal joints etc of size 24 Gauge complete all as specified and as directed.
63All as per item no.62.00 here-in before but of size 22 gauge
64M&L in replacement ofMCCB 4pole 125 Amps 25 KA complete all as specified and as directed.
65S&F in repairs to Voltage stabilizer of 2KVA to 5KVA of any make and model complete all as specified and as directed.
66M&L for replacement ofMNX-25/ 32 Amps Contactor including necessary screws, nuts and bolts complete all as specified and as directed.
67M&L for Contactor suitable to Split Acs of capacity 2TR complete all as specified and as directed.
68M&L for replacement of burnt scroll compressor including dismantling the unserviceable burnt afterdisconnecting suction/discharge side copper tube bolts rubber pads and washers connecting copper tubing by welding blazing nut flaring and repairing of gas leakage if any and completesuitable for 5.5 TR ductable split AC all as specified and as directed.
69All as per item no.68.00 here-in before but off 4.8 TR rotary compressor.
70M&L for rewinding of blower fan motor of existing size and capacity in cooling unit of ductable split type AC capacity 5.5 TR complete all as specified and as directed.
71All as per item no.70.00 here-in before but of 2.0 TR split type unit
72M&L for rewinding of Condensor fan motor of existing size and capacity in outdoor unit of AC capacity 5.5 TR complete all as specified and as directed.
73All as per item No.72.00 here-in before but 4.8 TR capacity
74M&L for HDPE pipes for drain out the drain points 25mm dia (each unit drain out) complete all as specified and as directed.
75M&L for power and control cabling between the indoor unit and out door unit of size 4 core x 1.5 sqmm copper wire complete all as specified and as directed.
76M&L for power and control cabling between the indoor unit and out door unit of size 4 core x 2.5 sqmm copper wire complete all as specified and as directed.
77M &L for duct accoustic insulation 25 mm thick with resin bonded fibre glass wool rigid board covered with tissue paper with 26 gauge GI perforated shee complete all as specified and as directed.
78M &L for duct thermal insulation 50 mm thick with aluminium foil faced fiber glass material of density 24 kg/cum, with factory laminated aluminium vapour barrier 26 guage thickness including (a) M&L for cleaning the duct surface (to be insulated ) by scrapping carefully with wire brush etc. to make the surface completely free of millscale, dirt, dust, grease and other foreign materials, taking special care so that all duct joints are sealed against any leakage. (b) M&L for applying rubber based adhesive CPRX compound. (c) M&L for sealing of all longitudinal joints and circular overlaps with and including Aluminium foil tape 50 mm wide, to make the insulation leakproof. (d) M & L for securing the insulation with and including mechanically fastened nylon/ steel straps of size 12 mm/50 mm at maximum intervals of 1.2 mtr.
79M&L for powder coated extruded aluminium supply air/4way diffuser with standard flanges complete all as specified and as directed.
80cutting of tree branches,cleaning of bushes.small plants surrounded the E/M installations including removing debris to a distance not exc 50mcomplete all as specified and as directed.
81Material and labour for submain wiringalongwith earth continuity conductor with PVC insulated FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) of nominal size 2x4 sq mm + 1x4 sq mm (earth)drawing through and including PVC casing capping of suitable size and its accessories complete all as specified and directed. Note.(a) Two runs of single cable with one run of earth continuity cable ncluding PVC casing capping and its accessories shall be measured and paid as one unit.(b) surface shall be make good as existing.
82Material and labour for submain wiringalongwith earth continuity conductor with PVC insulated FRLS multistrand copper conductor cable (Phase - Red, Neutral - Black, Earth - Green) of nominal size 2x6 sq mm + 1x6 sq mm (earth)drawing through and including PVC casing capping of suitable size and its accessories complete all as specified and directed. Note.(a) Two runs of single cable with one run of earth continuity cable ncluding PVC casing capping and its accessories shall be measured and paid as one unit.(b) surface shall be make good as existing.
83S&F 230 V AC,50 Hz,25 Amp with cyclic timer 3-999 minute programmable interval between two AC (Programmable alternate operation of AC-01 AND AC-02) AC ON indication for AC-01 and AC-02 power on indication single phase and two input terminal etc complete all as specified and as directed.
84S&F in replacement of old rusted AC mounting bracketwith replacing 24 inch heavy duty wall mounted bracket load bearing capacity upto 50 Kg complete all as specified and as directed.
85Supply and fixing in replacement of 415V 10KA \"C\" curve miniature circuit breaker (MCB) of TP63 Ams and current carrying capacity in the DB complete with connection testing and commissioning.complete all as specified and as directed.
86Supply and fixing in replacement of 415V 10KA \"C\" curve miniature circuit breaker (MCB) of TPN 100 Ams and current carrying capacity in the DB complete with connection testing and commissioning.complete all as specified and as directed.
87Supply and fixing amp rating240V, 10KA \"C\" curve miniature circuit breaker (MCB) SP5-32 Ams and current carrying capacity in the MCB DB complete with connection testing and commissioning.complete all as specified and as directed.
88Supply and fixing inreplacement of 25/32/40 Amps RCCB A-Type (DP-2M) 240 Volt, 50Hz,10 KA breaking capacity 100mA a.complete all as specified and as directed.
89Attending complaints related to air conditioning system package type/cassete type from 4.8 11TR including detecting of internal faults any type.complete all as specified and as directed.Note:(a) contractor shall attend the complaints on requirement basis from 0930hr to 1730hr on working days including saturday/sunday/holidays (if required.(b) Contractor shall deployed one highly skilled refrigeration mechanic and helper unskilled category for attending the complaint.(c) quoted rate shall deemed to include cost ofone highly skilled refrigeration mechanic and helper unskilled category.
90Total Amount in Figures
91Quoted Amount in Words

AI Tender Summary

OUR REF NO 46133733
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 13.72 Lakhs
LAST DATE 09-12-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Maintenance To Air-Conditioning, Water Coolers And Allied E/M Services At Aob Rambilli.
Basic Detail
Tender No GE(P) VARSHA/TOKEN/09 OF 2024-25
Bidding Type Tender
Location
City rambilli
State Andhra Pradesh
Key Dates
Publish Date 02 Dec 2024
Submission Date 09 Dec 2024
Open Date 13 Dec 2024
Finance
Tender Value 13.72 Lakhs
Tender Fee 500
EMD 27400
Exemption Available
Document List
TenderDocumentsmaintAC.pdf
IPmaintAC.pdf
BOQ_764734.xls
ef69a9fd-f8b8-4d06-8147-bcfd23706a89.html
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Dec 02, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Dec 09, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Dec 09, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Dec 13, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
pdf

TenderDocumentsmaintAC.pdf

pdf

IPmaintAC.pdf

xls

BOQ_764734.xls

html

ef69a9fd-f8b8-4d06-8147-bcfd23706a89.html

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender