| 1 | B/R WORKS |
| 2 | Excavating in post holes (or similar holes) each n exc0.5 cu. m, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering, and removing surplus soil to a distance n exc50m and making good surface in SOFT/LOOSE soil complete, all as specified and directed. |
| 3 | M&L for PCC type C-2 (1:3:6), type C-2 using 40 mm graded crushed stone aggregates as in filling & mass concretecomplete all as specified and directed. |
| 4 | S&F Mild steel works as in framed brackets, angles,tees with web and flanges, cut to shape , drilled or counter sunk for screw, and welding angles, gusset plates, base plates, etc , riveting, anchoring bolts, etc confirming to Fe-290 or Gde E- 165 complete all as specified and as directed . |
| 5 | S&F Rolled mild steel work in tubular trusses including special shaped washer etc. complete using ERW or induction butt welded tubes conforming to I. S.1161-1979 gradeSt.-240, complete all as specified and directed. |
| 6 | S&F Pre-painted galvalume aluminium zinc coating GI based corrugated steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 7 | S&F Pre-painted galvalume aluminium zinc coating GI based plain steel sheet 0.50 mm of any colour hving tensile strength of 550 Mpa as in roof coverng/ cladding to wall, fixed with self tapping screws complete all as specified and directed. |
| 8 | M&L for 100 mm thick, cement concrete type D-2, 1:4:8 using 40 mm graded crushed stone aggregate, finished even & rough, as in sub floors, complete all as specified and directed. |
| 9 | M&L for Factory made, rubber molded kerb stone and drainage channels of M-25 grade cement concrete, laid dry in position to the rquired line level and curvature, jointed with cement mortar (1:3) including making joints with or without grooves (thickness of joints except at sharp curve shal not be more than 5 mm) including making drainage opening whereever required, complete all as specified and directed. |
| 10 | M&L for 60mm thick factory made chamfered edge cement concrete paver block of M-30 grade with approved colour, design & pattern as in footpath, parks, lawns, drive ways or light traffic parking etc., of shape approved by GE, made by table vibratory method using PU mould, laid in required pattern over and including 25mm thick compacted bed of coarse sand, compacting through vibratory compaction by using plate vibrator, filling the joints with fine sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand; complete all as specified and directed. |
| 11 | M&L for Two coats of synthetic enamel paint over & including a coat of red oxide primer over new steel & iron surfaces of any description, not otherwise described, over 10 cm in width or girth, including preparation of surfaces complete all as specified and directed. |
| 12 | Demolition of cement concrete (unreinforced) of any description and in any position not otherwise specifically provided complete all as specified and directed. |
| 13 | Dismantling wrought iron or mild steel work of any description, complete all as specified and directed. |
| 14 | Dismantling timber scantling 40 sq. cm and over in section, in any position, complete all as specified. |
| 15 | Dismantlingplain or corrugated steelsheets in roof coverings, complete all as specified. |
| 16 | E/M WORKS |
| 17 | Disconnectiing & taking down water storage geyser for repair etc. from existing location and refixing & reconnecting the same on orginal or new location after repair complete, ofthe following capacities:- |
| 18 | 25 litre |
| 19 | 35 litre |
| 20 | 50 litre |
| 21 | NOTE: Repair / Replacement of unserviceable spare parts/items and painiting as specified will be measured & paid for under serial item No. 20.00 to 20.23 here-in-below as required & where directed. |
| 22 | Dismantling/ taking out of inner storage hot water tank , geyser assembly, heating element , glass wool etc from in side the geyser of capacity 25 /35/50 litre and including remove blockage / depositing the scale, silt, sludge, dirty particles material from the inside of the storage heating system through method of descaling with chemical acid or manually mechanically system and after washing in side of the storage heating tank, geyser assembly, heating element, thermostat system including tighting, adjustment, servicing and also rectification the leakage problem of hot tank through hot & cold welding / brazing (gas or electric welding) work system for steel tank / copper tank complete and after repair re-assembly and proper filling the glass wool and replacement of defected items in side around the tank complete.NOTE: Repair / Replacement of unserviceable spare parts/items and painting will be measured & paid for under serial item No. 20.00 to 20.23 here-in-below as required & where directed. |
| 23 | Replacement of the unserviceable articles/parts of water storage geyser as required & where directed as under: - |
| 24 | Supply only Heating elementof copper / brass alloy round , triangular, round with threaded type shape /alongwith \"O\" ring washer as per existing size sample / modelfor rating 1.5 kW complete. |
| 25 | Supply only Heating elementof copper / brass alloy round , triangular, round with threaded type shape /alongwith \"O\" ring washer as per existing size sample / modelfor rating 2 kW complete. |
| 26 | Supply only Copper/brass alloy round shape /size as per existing sample/model typespecial electric geyser heating elements of rating capacity 2 KW with having U cut shape of heating rod and round base with round ringwasher and alongwith having thermostate base rod including numbers of hole for adopting of geyser thermostat purpose suitable for using in MAP qtr installed electric geysers systemIN REPLACEMENT complete. |
| 27 | Supply only Inner cold and hot water circulating apparatus unit assembly (Geysers assembly) alongwith replacement of defected nuts and bolts and rubber check washer, split gas pin system complete, for geyser capacity 25 Litre |
| 28 | Supply only Inner cold and hot water circulating apparatus unit assembly (Geysers assembly) alongwith replacement of defected nuts and bolts and rubber check washer, split gas pin system complete, for geyser capacity 35 Litre |
| 29 | Supply only Inner cold and hot water circulating apparatus unit assembly (Geysers assembly) alongwith replacement of defected nuts and bolts and rubber check washer, split gas pin system complete, for geyser capacity 50 Litre |
| 30 | Supply only Gun metalverticaltype non return valve of size 15 mmbore complete. |
| 31 | Supply only Hot water inner tank made out of heavy duty stainless steel sheet metal body system alongwith nuts and bolts and rubber joint washers for storatge type geyser capacity 25 Litre complete. |
| 32 | Supply only Hot water inner tank made out of heavy duty stainless steel sheet metal body system alongwith nuts and bolts and rubber joint washers for storage type geyser capacity 35Litre complete. |
| 33 | Supply only Hot water inner tank made out of heavy duty stainless steel sheet metal body system alongwith nuts and bolts and rubber joint washers for storage type geyser capacity 50 Litre complete. |
| 34 | Supply only Adjustable setting type thermostat made out of copper / brass alloy metalfor storage type geyser capacity 25-35 Litre complete |
| 35 | Supply only Adjustable setting type thermostat made out of copper / brass alloy metalfor storage type geyser capacity 50 Litre complete |
| 36 | Supply only Capilary setting type thermostat made out of copper / brass alloy metalfor storage type geyser capacity 25 Litre complete |
| 37 | Supply only Air safety valve for storage geyser of capacity 25 ltr to 50 Litre complete |
| 38 | Supply only Insulating material i.e. glass wool for filling inside area in between of geyser outer body and hot water tank system including dismantling of geyser for capacity 25 to 35 Litre complete |
| 39 | Supply only Insulating material i.e. glass wool for filling inside area in between of geyser outer body and hot water tank system including dismantling of geyser for capacity 50 Litre complete |
| 40 | Supply only Mild steel outer cover top plate duly spray painted with super enamel paint over a coat of red oxide primer complete for25 to 35 Litre capacity storage geyser. |
| 41 | Mild steel outer cover top plate duly spray painted with super enamel paint over a coat of red oxide primer completefor 50 Litre capacity storage geyser. |
| 42 | Supply only Mild steel outer bottom cover plate duly spray painted with super enamel paint over a coat of red oxide primer complete for25 to 35 Litre capacity storage geyser. |
| 43 | Supply only Mild steel outer bottom cover plate duly spray painted with super enamel paint over a coat of red oxide primer complete for 50 Litre capacity storage geyser. |
| 44 | Supply only Mild steel outer body cover duly spray painted with super enamel paint over a coat of red oxide primer complete for25 to 35 Litre capacity storage geyser. |
| 45 | Supply only Mild steel outer body cover duly spray painted with super enamel paint over a coat of red oxide primer complete for50 Litre capacity storage geyser. |
| 46 | Supply only Indicating lamp Red /Green round & square shape display for geyser on / off indicating system complete all as specified. |
| 47 | NOTE FOR SERIAL ITEM 20.01 TO 20.24: The size/make/ model/nomenclature above mentionednew items shall be as per existing item or as directed by Engineer-in-Charge. |
| 48 | M&L for Spray painting to external body of storage geyser of capacity 25/35/50 litre including clamps with first qualitysynthetic enamel paint of white shade,at site or in store including filling cavities with filler materialsand preparation of steel surfaces including marking MESNo. with black paint on each geyser complete all as specified and directed. |
| 49 | S&F Heavy duty PVC braided PVC connection pipe of size 15 mm dia and 450 mm long alongwith two nos of brass nut and nylon washerIN REPLACEMENT complete all as specified and directed. |
| 50 | S&F Heavy duty steel wire braided chromium plated stainless steel metal body connection pipe of size 15 mm bore and 600 mm long alongwith two nos of brass nut and nylon washerIN REPLACEMENT complete all as specified and directed. |
| 51 | S&F Angle valve suitable for 15 mm bore made out of cast copper alloy chromium plated iron pipe connection IN REPLACEMENT complete all as specified and directed. |
| 52 | S&F Flexible type PVC bedded copper cable of size 2.5 sq.mm 3 core (40/00.0076 type size) 1100 volt grade cable withPVC insulated PVC sheathed with multi stranded copper conductor IN REPLACEMENT complete all as specified and directed |
| 53 | S&F MS sheet metal enclosure assembly with having SPN enclosure and 2/3 pin top plug & earth socket of rating voltage 220 volt ACIN REPLACEMENT complete all as specified and directed. |
| 54 | S&F Cast copper alloy chromium plated bib tap 15 mm size, quarter turn type for iron pipe,IN REPLACEMENT complete all as specified and directed. |
| 55 | S&F Heavy duty MS fasteners of suitable of size 10 mm dia not exceeding up to 100 mm long along with nut, bolt & washer etc including drilling holes grouting on wallfor hanging geyser. and making good the disturbed surfaces to the entire satisfaction of Engineer in Charge,IN REPLACEMENT complete all as specified and directed. |
| 56 | Sub main wiring system with having two run of PVC insulated wire of size 2.5 sq.mm FRLSH multistrand copper conductor cable 1100 volts grade drawn into including providing one run of 2.5 Sq.mm FRLSHmultistrand copper conductor cable as continuous earth wire for connecting to common earthincluding taking down existing wiring all as specified. |
| 57 | M&L for Sub main wiring system with having two run of PVC insulated wire of size 4 sq.mm FRLSH multistrand copper conductor cable 1100 volts grade drawn into including providing one run of 4 Sq.mm FRLSH multistrand copper conductor cable as continuous earth wire for connecting to common earthincluding taking down existing wiring all as specified and directed |
| 58 | S&F Rigid non metallic heavy duty PVC conduit medium grade not less than 20 mm dia ISI marked alongwith all conduit fittings and fixing accessories duly fixed on wall / surface / roof mounting system with the help of saddle with base clamps IN REPLACEMENT complete all as specified and directed. |
| 59 | S&F MCB SP of rating capacity 20 Amp , 220 Volt AC and making electrical connection,IN REPLACEMENT complete all as specified and directed. . |
| 60 | S&F MCB SPN of rating capacity 40 Amp, 220V, ACand making electrical connection, IN REPLACEMENT complete all as specified and directed. |
| 61 | S&F PVC insulated body three pin plug top of rating capacity 15/16 Ampand making electrical connection IN REPLACEMENT complete all as specified and directed. |
| 62 | S&F Switch piano flush button single pole one way 16 Amp, 240 volts IN REPLACEMENT complete all as specified and directed. |
| 63 | SOLAR WATER HEATING SYSTEM WORKS |
| 64 | S&F Copper / brass heating element round & triangular shape size of rating capacity 3/4 KW including along with providing suitable rating / type of thermostat complete set all as per existing size sample/ model and including duly fixed on existing solar heating system, IN REPLACEMENT complete all as specified and directed. |
| 65 | S&F U-Rubber (rubber rectangular paking ) as per existing size / samplesuitable for outer cover frame and using for fixing of outer side of each solar heating collector panel plate of capacity 100 LPD system proposed including providing with rubber solution, IN REPLACEMENT complete all as specified and directed. |
| 66 | S&F Round shape type rubber gaskets suitable used for fixing or packing of pipe line attachment system proposedincluding replacement of suitable size / type of SS nut , bolt washerIN REPLACEMENT complete all as specified and directed . |
| 67 | S&F Heavy duty round \"U\" cut shape type rubber groumats as per existing sample / size suitable used for fixing / attachment of inner side of hot copper piping jal system with solar collector plate attechment supporting system proposedincluding providing of rubber solution complete all asper existing size and type IN REPLACEMENT complete all as specified and directed . |
| 68 | S&F Round shape mild steel blank flanged suitable for 20 mm dia bore pipe line including making of nos of holes alongwith suitable used for fixing of outer side of hot / cold pipeing line attachment system proposedincluding replacement of defected suitable size / type of SS nut , bolt washer, IN REPLACEMENT complete all as specified and directed . |
| 69 | S&F Aluminium foil rapping work in side of solar heating collector each panel plate system as per existing size and type including providing of adaptor solution material including taking down existing broken/defected aluminium foil IN REPLACEMENT complete all as specified and directed . |
| 70 | S&F Insulation material suitable for filling of inside of solar heating collector panel plate system and solar tank ,and it connecting hot pipe lines system proposed including taking down existinginsulation material IN REPLACEMENT complete all as specified and directed. |
| 71 | S&F MS flanges fitted GI nipple of size 20 mm dia up to 4 inch long as per existing size and type IN REPLACEMENT complete all as specified and directed . |
| 72 | S&F Rubber hose pipes of size 20 mm dia ,150 mm long with adhaptor clamp as per existing size and type IN REPLACEMENTcomplete all as specified and directed . |
| 73 | Testing and commissioning of solar storage warm stainless steel tankwith inner heat exchanger system and duly fitted fully insulated materials with outer side aluminium cladding fram work complete system set and including providing alogwith connected suitable type / size rating fixing accessories like temperature gauge , heating element port , inlet and outlet pipe line water connection setIN REPLACEMENThot tank system all as specified.of capacity: - |
| 74 | 200 Litre |
| 75 | 500 Litre |
| 76 | 1000 Litre |
| 77 | NOTE FOR SERIAL ITEM 45.01 TO 45.03 The size/make/ model/nomenclature of above item(s) shall be as per existing item or as directed by Engineer-in-Charge. |
| 78 | S&F Solar plate toughened heating glass of appoximate size 184 cm long 124 cm wide & 4 mm thick or as per existing size or sample suitable for using / fixing on suitable for solar heating collector plate assembly set of total heating capacity of each plate 100 LPD and duly properly fixed on existing top structure fixing & attachment on existing solar water heating colletor plate assembly system of capacity 200 LPD, 500 LPD & 1000 LPD IN REPLACEMENT complete all as specified and directed . |
| 79 | S&F Aluminium metal sheet as per existing size / gauge suitable for fixing on solar attachment heating system IN REPLACEMENT complete all as specified and directed . |
| 80 | Material and labour for disconnection of electric supply and water pipe line connections and taking out all type of clamp, nut bolt or connected fixing accessories from the existing position of each solar plate from solar heating collector plate system and removing all fixing accessories like aluminum side frame cladding ,heating top glass with rubber packing materials , copper fins with tubing plates jal assembly for the proposedof claening in side / removing blockage / depositing the scale ,sult, sludge, dirt etc particle material from in side of copper tubes jal assembly including cleaning ,checking, serviving , tighting , adjusting and also calibration and descaling through chemical acid solution method / manually mechanically system for making of nos of hole on each blockage copper tube assembly through suitable size of drilling rod with cleaning of wire brush in each copper tubing system and their after duly fill up the all nos of making hole work in copper tubes through hot & cold welding / brazing (gas or electric welding) work system and applying two coats of black bituminous paint over on distrubed place of copper fin and tubing jal system and after circulation of chemical acid solution through proper pressure washing pump in complete entire system and also rectification the leakage problem of entire tube system complete and after repair reaasembly and proper filling the all replacement item like insulation wool and aluminium foilingGlass work in side and around the collector plate system andreplacement of defected nut, bolt & washer and fixing on same position and testing on system complete all as specified and directed. |
| 81 | NOTE APPLICABLE TO SERIAL ITEM 48: (i) Spare parts will be measured and paid separately under respective items ofBoQ.(ii) Descaling, driiling ,Servicing, adjusting etc and testing run work will be carried out by well qualified techanician having good experience in the about repairing field of solar water heating system . |
| 82 | M&L for Disconnection of electric supply and water pipe line connections and demolation of PCC work and taking out all type of clamp, nut bolt or connected fixing accessories from solar warm tank, PVC storage tank and complete solar collector plate assembly unit with iron structure frame and connected pipe work system complete including removing all fixing accessories like heating top glass with rubber packing materials , copper fins with tubing platesjal assembly from the existing position and shifting to complete system from one place to other place and they after including duly providing welding / brazing work for broken system for fill up the all damage work on iron & in tubes systemthrough hot & cold welding / brazing (gas or electric welding) work and after reassembling on new position by replacement of defected nut, bolt & washer and refixing on same system and testing on load complete all as satisfaction and specified & direction fo EIC NOTE -(i) Spare parts, item of work will be measuresed and paid separately under respective items of schedule \"A\" |
| 83 | M&L for Testing and commissining IN REPLACEMENT of of broken / damage unserviceable solar water heating collector plate assembly set complete suitable for solar heating coolector plate assembly of heating capacity 100 LPD and as per collector plate appoximate size 185 cm long 125 cm wide & 11 mm thick or as per existing size or sample suitable for using / fixing & attachment on 200 LPD to 1000 LPD capacity of solar heating system.The outer body of solar collector plate assembly set made out / fabricatedaluminium structure frame work along with aluminium clading forall side support frame with U rubber, heating tuffen top glass with rubber packing materials , copper heat exchanger fins with copper tubing plates set jal assemblyand duly fully insulated with insulated materials with aluminium foiling work etc and providing with connected suitable type / size inlet outlet pipe connection complete setand including dismantling and taking out of existing old unserviceable plate collector system complete all as specified and directed. |
| 84 | M&L for Disconnecting of electric wire and water pipe line connections & taking out of insulation materials from existing drain out position for the proposedof repairing & descaling of inner steel hot water tank of solar water systemand including cleaning & remove blockage / depositing scale, silt, sludge, dirt etc particle material from the in side of the storage steel heating tank system through properly method of descaling ,and washing with chemical acid solution / manually / mechanically system including proper repair in fixing in place of heating element, thermostat system,temperature gauge point including tighting,adjustment, servicing, replacement of defected air release valve rubber gasket and also rectification the leakage problem of steel hot water tank by the help of hot & cold welding / brazing (gas or electric welding) work method complete and after repair reasembly and proper filling the glass wool ,alumium sheet covercladding work andother replacement items in side / out side/ around the hot tank and pipe line system and after testing of leakage complete suitable of capacity: - |
| 85 | 200 LPD to 500 LPD |
| 86 | 1000 LPD. |
| 87 | Galvanised iron medium grade tubes laid under path, on roofs or on walls with all pipe fittings and fixing acessories, IN REPLACEMENT complete all as specified of size: |
| 88 | 15 mm bore |
| 89 | 20 mm bore |
| 90 | M&L Mild steel work as in staging structure / support frame by cross arms or angle or channel , MS sheet including bracings, supports, clamps and back plates fabricated frame structural steel sections work including nuts, bolts and washers, welding, bending, cold or hot drilling and making holes for bolts in any shape or size and inclusive of one primer coat, one under coat and one finished coat of paint for solar water heating system IN REPLACEMENT complete all as specified and directed. |
| 91 | S&F PVC HDPE rotational moulded water storage tanks (cylidrical vertical type with closed top), triple layered, ISI marked fixed in position and making inlet and outlet water piping line connections,IN REPLACEMENT complete all as specifiedof size/capacity:- |
| 92 | 500 Litre |
| 93 | 1000 Litre |
| 94 | S&F Ball brass valve, high pressure with polythene float and flynut complete screwed for iron pipe or brass ferrule 20mm bore, ISI marked, IN REPLACEMENT complete all as specified and directed. |
| 95 | Demolition forPCC of any description and any position and providing PCC (1:3:6 ) type C-1 using 20 mm stone aggregate work for laying PCC at difference location/ installation including necessary form work and finishing work the exposed faces of concrete even and smoothusing extra cement complete all as specified and directed. |
| 96 | Sheet metal enclosure duly powder coatedMCB distribution box SPN 2 way with having mounting channel and connection bus bar system fixed flush on wall with cement mortar (1:4) and making all necessary electrical connection, IN REPLACEMENT complete all as specified and directed. |
| 97 | Sheet metal enclosure duly powder coated double door system MCB distribution box SPN 4 way with having mounting channel and connection bus bar system fixed flush on wall with cement mortar (1:4) and making all necessary electrical connection, IN REPLACEMENT complete all as specified. |
| 98 | Applying of two coats black colour superior quality synthetic enamel paintwork for all fixing iron attachment support system of complete solar water heating system like staging structure of hot and cold tank,make up tank , solar collector plate fixing support iron assembly suitable for complete solar water heating system of capacity including preparation of surfaces to the entire satisfaction of Engineer-in-Charge and making necessary welding work if required completeall as specified of capacity: - |
| 99 | 200 LPD |
| 100 | 500LPD |
| 101 | 1000 LPD |
| 102 | Water make up tank duly fabricated / made out of 2 mm thik mild steel sheet of suitable of size 400 mm long x 20 mm wide x 25 mm height to make a shape of rectangular type alogwith providing lead 2mm thick mild steel and inclduding making 03 nos of hole for inlet and outlet proposedof water connection system and inserting the suitable size socket 15/20 mm dia alongwith nipple complete all as specified and directed . |
| 103 | Tempreture gauge meter as per existing type samplesuitable for measuring rating of water temperture 0 to 120 degree C including duly fixed on exisiting position of systemIN REPLACEMENT complete all as specified and directed. |
| 104 | Cleaning of RCC / PVC service tank by art technology \"\"Tank cleaning\"\" removing the mud / sludge with pump cleaning the roof, walls and bottom inside & outside by using dirt cleaner and sparying of customised anti bacterial agent on entire surface and drying up properly the complete tank / sump including writing out side the tank as \"\" Tank cleaned on and capacity\"\" on black painted surfaces of following capacity : - |
| 105 | 200 Litre |
| 106 | 500 Litre |
| 107 | 1000 Litre |
| 108 | NOTE APPLICABLE TO SERIAL ITEM 62: (i) Disconnect and re-fixing of float valve, inlet and outlet pipe connection including in this item. (ii) Removing of mud disposed to at location mentioned in Schedule \"A\" note 5(d). |
| 109 | Supplying, laying, jointing and testing XLPE insulated heavy duty multi stranded armoured and PVC sheathed LT cable 6 Sq.mm 4 core 1100 volts grade with aluminium conductor laid in trenches / walls / ducts/ along poles/through pipes including taking out existing cable complete all as specified and directed, |
| 110 | NOTE FOR SERAL ITEM 17 to 63 :- Not withstanding with the provision of \"Compensation for Delay\" envisaged under condition 50 of IAFW-2249, General Conditions of Contracts, additional compensation@ Rs. 500/- per day will be charged from contractor in case he fails to make the functional to the entire satisfaction of Engineer-in-Charge within 24 hour of receiving of complaint from the MES regarding non working above items. |
| 111 | Note : Amount ofcredit for retrieved materials is mentionedin Sch \"A\" Section-II of tender documents in pdf form which will be deducted while acceptance of tender offline. |