| 1 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead upto 50 m and lift up to 1.5 m. All kinds of soil |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. All kinds of soil. |
| 3 | Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 1000 mm dia piles |
| 4 | Providing, driving with hydraulic piling rigs with power units and installing driven cast-in-situ reinforced cement concrete piles of grade M-25 of specified diameter and length below the pile cap, to carry safe working load not less than specified, excluding the cost of steel reinforcement but including the cost of shoe and the length of pile to be embedded in the pile cap etc. all complete. (Length of pile for payment shall be measured from top of shoe to the bottom of pile cap) : 500 mm dia piles |
| 5 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:3:6 (1 Cement : 3 coarse sand (zone-III) derived from natural sources: 6 graded stone aggregate 40 mm nominal size derived from natural sources). |
| 6 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level. 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 7 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns,pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement. 1:1.5:3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources). |
| 8 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: (a) Foundations, footings, bases of columns, etc. for mass concrete |
| 9 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: (b)Lintels, beams, plinth beams, girders, bressumers and cantilevers |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for all heights: (c)Columns, Pillars, Piers, Abutments, Posts and Struts |
| 11 | Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level and above plinth level.Thermo-Mechanically Treated bars of grade Fe-500D or more. |
| 12 | Filling available excavated earth (excluding rock) in trenches, plinth, sides of foundations etc. in layers not exceeding 20cm in depth, consolidating each deposited layer by ramming and watering, lead up to 50 m and for all lift. |
| 13 | Brick work with clay flyash F.P.S. (non modular) brick of class designation 7.5 in superstructure above plinth level up to floor five level in : Cement mortar 1:6 (1 cement : 6 coarse sand) |
| 14 | Providing and laying Polished Granite stone flooring in required design and patterns, in linear as well as curvilinear portions of the building all complete as per the architectural drawings with 18 mm thick stone slab over 20 mm (average) thick base of cement mortar 1:4 (1 cement : 4 coarse sand) laid and jointed with cement slurry and pointing with white cement slurry admixed with pigment of matching shade including rubbing, curing and polishing etc. all complete as specified and as directed by the Engineer-in-Charge: Polished Granite stone slab colour of Black, Cherry/Ruby Red or equivalent |
| 15 | Providing and fixing stainless steel (Grade 304) work made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, i/c fixing the railing with necessary accessories & stainless steel dash fasteners , stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge. |
| 16 | Supplying and stacking of good earth at site including royalty and carriage upto 5 km lead complete (earth measured in stacks will be reduced by 20% for payment). |
| 17 | Supplying and stacking at site dump manure from approved source, including carriage upto 5 km complete (manure measured in stacks will be reduced by 8% for payment) : Screened through sieve of I.S. designation 16 mm |
| 18 | Digging holes in ordinary soil and refilling the same with the excavated earth mixed with manure or sludge in the ratio of 2:1 by volume (2 parts of stacked volume of earth after reduction by 20% : 1 part of stacked volume of manure after reduction by 8%) flooding with water, dressing including removal of rubbish and surplus earth, if any, with all leads and lifts (cost of manure, sludge or extra good earth if needed to be paid for separately) :Holes 60 cm dia, and 60 cm deep |
| 19 | Mixing earth and sludge or manure in the required proportion specified or directed by the Officer-in-charge |
| 20 | Providing and stacking of Bottle palm of ht. 270-300 cm bottom girth 40-50 cm well developed in big HDPE bags as per direction of the officer-in-charge |
| 21 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cost of plant & water). Trees Plant |
| 22 | Providing and Displaying Acalypha red well developed with fresh & healthy 30 to 45 cm ht. in 20 cm size Earthen Pot/ Plastic Pot as per direction of the officer-in-charge. |
| 23 | Plantation of Trees, Shrubs, and Hedge at site i/c watering and removal of unserveiceable material’s as per direction of officer in charge (excluding cast of plant & water). Hedge Plant /Ground cover |
| 24 | Preparation of beds for hedging and shrubbery by excavating 60 cm deep and trenching the excavated base to a further depth of 30 cm, refilling the excavated earth after breaking clods and mixing with sludge or manure in the ratio of 8:1 (8 parts of stacked volume of earth after reduction by 20%: one part of stacked volume of sludge or manure after reduction by 8%), flooding with water, filling with earth if necessary, watering and finally fine dressing, leveling etc. including stacking and disposal of materials declared unserviceable and surplus earth by spreading and leveling as directed, within a lead of 50 m, lift up to 1.5 m complete (cost of sludge, manure or extra earth to be paid for separately) |
| 25 | Providing and laying factory made chamfered edge Cement Concrete paver blocks in footpath, parks, lawns, drive ways or light traffic parking etc, of required strength, thickness & size/ shape, made by table vibratory method using PU mould, laid in required colour & pattern over 50 mm thick compacted bed of sand, compacting and proper embedding/laying of inter locking paver blocks into the sand bedding layer through vibratory compaction by using plate vibrator, filling the joints with sand and cutting of paver blocks as per required size and pattern, finishing and sweeping extra sand. complete all as per direction of Engineer-in-Charge. 80 mm thick C.C. paver block of M-35 grade with approved colour design and pattern. |
| 26 | Supplying and filling in plinth with sand under floors, including watering, ramming, consolidating and dressing complete. |
| 27 | Providing and laying Neelgiri/Mexican grass turf with earth 50mm to 60mm thickness of existing ground prepared with proper level and ramming with tools wooden (Dhurmos) and than rolling the surface with light roller make the surface smoothen and light waterning with sprinkler and maintenance for 30 days or more till the grass establish properly, as per direction of officer-in-charge. |
| 28 | Supply & Installation of 100 feet Monumental Indian National Flag mast as per items described below:-I. Supply Portiona. Supply of 100 feet Flag mast in sections, hot dip galvanized (BSEN - 1461) and suitable for wind velocity as per IS 875 (75 Meter per second) along etc complete as required.b. Supply of lowering system and Hoisting mechanism of 100 feet flag mast including head frame, double drum winch, SS wire rope (SS 316 graded 7/19 construction), pulleys, electric Motor (IS 325), counter weight etc complete as required as per ILE TR7.c. Supply of lighting finial with special Type Dome etc complete as required.d. Supply of PU paint along with primer & others for 100 feet flag mastd. Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templatesII. Labour Portiona. Erection of the Flag Mast with the help of suitable equipments including stress fit assembly complete with lowering lifting arrangement complete as required.c. Labour & T&P charges for painting of PU paint on flag high mastIII. Flaga. Supply & installation of Indian national flag of size 20 ft X 30ft made out of knitted polyester fabric (3 nos). |
| 29 | Supply & Installation of 95 feet Monumental ONGC Flag mast as per items described below:-I. Supply Portiona. Supply of 100 feet Flag mast in sections, hot dip galvanized (BSEN - 1461) and suitable for wind velocity as per IS 875 (75 Meter per second) along etc complete as required.b. Supply of lowering system and Hoisting mechanism of 100 feet flag mast including head frame, double drum winch, SS wire rope (SS 316 graded 7/19 construction), pulleys, electric Motor (IS 325), counter weight etc complete as required as per ILE TR7.c. Supply of lighting finial with special Type Dome etc complete as required.d. Supply of PU paint along with primer & others for 100 feet flag mastd. Supply of foundation bolts manufactured from special steel along with nuts, washers, anchor plates and templatesII. Labour Portiona. Erection of the Flag Mast with the help of suitable equipments including stress fit assembly complete with lowering lifting arrangement complete as required.c. Labour & T&P charges for painting of PU paint on flag high mastIII. Flaga. Supply & installation of ONGC flag of size 20 ft X 30ft made out of knitted polyester fabric (3 nos). |
| 30 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. External work 80 mm dia nominal bore |
| 31 | Painting G.I. pipes and fittings with two coats of anti-corrosive bitumastic paint of approved quality : 80 mm diameter pipe |
| 32 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade ofsize4 core 16 sqmm armoured copper cable (clamped with 1mm thick saddle) on wall surface as required. |
| 33 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade ofsize 4 core 16 sqmm armoured copper cabledirect in ground / Road crosing including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 34 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 35 | Supply ofPVC sheathed / XLPE power cable of 1.1 kV grade of 4 Core 16 sqmm size armoured copper cable |
| 36 | Supplying and making end termination with brass compression gland and copper lugs for 4 X 16 sq. mmsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 37 | Supplying and fixing 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 38 | Supplying and fixing 16 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 39 | Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 40 | Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade ofsize3 core 2.5 sqmm armoured copper cable (clamped with 1mm thick saddle) on wall surface as required. |
| 41 | Supply ofPVC sheathed / XLPE power cable of 1.1 kV grade of 3 Core 2.5 sqmm size armoured copper cable |
| 42 | Supplying and making end termination with brass compression gland and copper lugs for 3 Core 2.5 sqmm size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 43 | Supplying and Drawing of 5 x 1.5 sq.mm FRLS PVC insulated copper conductor cable in the existing recessed steel /PVC conduit as required |
| 44 | supply and installation of twin set of avitiation mast light for flag pole as Required. |
| 45 | Wiring for circuit/ submain wiring alongwith earth wire with the 2 X 2.5 sq. mm + 1 X 2.5 sq. mm earth wire of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required. |
| 46 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 47 | Supply ofHavells CONE NXG LED BOLLARD Lights (1 unit consists of 04 Nos.) |
| 48 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting / LED light fittings of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 49 | Supply of Supply of CORAL LED POST TOPNew generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source. Opal Cover offers soothing uniform illumination |
| 50 | Supply & Installation of JETA IRIS ALPHA Energy saving, environmental friendly, long life, exclusive innovative die-cast aluminium IP66 flood light, suitable for highlighting architectural facade and general purpose lighting. |
| 51 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 52 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 53 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 kV grade ofsize 4 core 16 sqmm armoured copper cabledirect in ground / Road crosing including excavation, sand cushioning, protective covering and refilling the trench etc. as required. |
| 54 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 55 | Supply ofPVC sheathed / XLPE power cable of 1.1 kV grade of 4 Core 16 sqmm size armoured copper cable |
| 56 | Supplying and making end termination with brass compression gland and copper lugs for 4 X 16 sq. mmsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 57 | Supplying and fixing 32 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Triple pole and neutral in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 58 | Supplying and fixing 16 A rating, 240/415 V, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of Single pole in the existing MCB DB complete with connections, testing and commissioning etc. as required. |
| 59 | Supplying and fixing 4 way (4 + 12), Double door, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) |
| 60 | Supplying and making end termination with brass compression gland and copper lugs for 4 X 16 sq. mmsize of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 kV grade as required. |
| 61 | Installation, testing and commissioning of pre-wired, fluorescent fitting / compact fluorescent fitting / LED light fittings of all types, complete with all accessories and tube/lamp etc. directly on ceiling/ wall, including connections with 1.5 sq. mm FRLS PVC insulated, copper conductor, single core cable and earthing etc. as required. |
| 62 | Supplying and fixing suitable size GI box with modular plate and cover in front on surface or in recess, including providing and fixing 3 pin 5/6 A modular socket outlet and 5/6 A modular switch, connections etc. as required. |
| 63 | Earthing with G.I. earth pipe 4.5 meter long, 40 mm dia including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. with charcoal/ coke and salt as required. |
| 64 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modularswitch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 65 | Supply of CORAL LED POST TOPNew generation, IP 65 LED post-top family, energy saving, environmental friendly, long life aestheticallydesigned with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDsas light source. Opal Cover offers soothing uniform illumination |
| 66 | Supply of LYCUS LED SPIKE LIGHTEnvironmental friendly, new generation, energy saving, decorative IP66 LED spike light using COB LED aslight source. (1 unit consists of 04 Nos) |