Agriculture Boards / Undertakings / PSU Closing in 0 days TDR #46102730

Tender For Sitc Of Silent Dg Set (As Per Cpcb 4 Plu Norms) With Amf Panel Including Providing Earthing, Concrete Foundation And Providing Shed With Profile Sheet At Fsd Attabira, Fsd Balijhori, Fsd Hirakud And Fsd Rourkela Under Fci Do Sambalpur For

Issued by Boards / Undertakings / PSU · attabira, Odisha
Tender Value
42.25 Lakhs
Estimated cost
Bid Submission
19 Nov 2024
0 days left
EMD
84510
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
attabira → Odisha
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Sitc Of Silent Dg Set (As Per Cpcb 4 Plu Norms) With Amf Panel Including Providing Earthing, Concrete Foundation And Providing Shed With Profile Sheet At Fsd Attabira, Fsd Balijhori, Fsd Hirakud And Fsd Rourkela Under Fci Do Sambalpur For The Fy 202

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 08-Nov-2024 CORRIGENDUM for MSE Other 19-Nov-2024

BOQ

Name of Work: SITC of silent DG Set (As per CPCB IV + Norms) with AMF Panelincluding providing earthing, concerete foundation and providing shed with profile sheet at FSD Attabira, FSD Balijhori, FSD Hirakud and FSD Rourkela under FCI DO Sambalpur for the FY 2024-25
Sl. No. Item Description
1FSD Attabira
2Supply, Installation, Testing & Commissioning of \"silent type\" new Diesel Generator set of reputed make/ manufaturer having prime power rating of 25 KVA, 415 volt, 0.8 lagging power factor suitable for 50 HZ, 3 phase system (conforming to the norms of CPCB IV+ upto latest amendmend) comprising of 4 Stroke Liquid cooled Diesel Engine, electric start turbocharged & intercooled developing of min. 30.5 BHP at 1500 RPM, capable of taking 10 % over loading for one hour after 12 hours of continous operation coupled with self excited and self regulated, Brush less, Synchronous alternator with H class insulation in SPDP enclosure rated at 25 KVA, 415 V at 1500 RPM, 3 phase 50 HZ, A.C supply with 0.8 lagging power factor, both the engine and alternator shall be mounted on a common MS base frame in Accoustic & wheather proof enclosure on suitable C.C foundation as per manufacturer drawing & design complete with Automatic mains failure control Panel (AMF) with suitable rating MCCBs including auto/ manual by-pass, battery charger, Micro-processor based Genset controllers with display for voltages & Currents, Frequency, Genset KVA, KW, KWh, KVAr, Power Factor, Lube oil pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Emergency Stop, Battery charge condition, comprises of advanced Digital AVR for improving voltage regulation & response time, Electronic Governor, Fuel tank, Residential type silencer, AVM pads fitted on base frame, First fill of lube oil, 12V DC starting system comprising of starter motors & 1 No. 12V battery including transportation, loading and unloading of the DG set. The entire set must be warranted least of 24 months / 5000 Hrs from the date of Commissioning whichever is earlier. The agency will have to fill full tank & provide permanently multi-core control cables as required with allied accessories including laying of the same before commissioning of the DG set and also including supplyingandfixingexhaustgaspipingof suitabledia.weldedblackMS,BClasspipe conformingtoIS:3589cuttorequiredlengths andinstalledwithnecessarybends,supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50mmthickwiremesh&aluminumcladding etc., The DG set should be of reputed brand and must be approved by the Engineer-in Charge and installed as per CPWD specifications.
3Supply of XLPE Power cable of size 4x16 sq.mm of 1.1 KV grade armoured Al. Cable Compulsary ISI made Confirming to IS : 7098/ Pat -I / 88 with amendment no Iof reputed makeas required.
4Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required..
5Providing and fixing 25 mm X 5mm G.I Strip in 40 mm dia G.I pipe from earth electrode electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling as required.
6Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
7Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. upto 35 Sq.mm
8Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE powercable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle)upto 35 Sq.mm (clamped with 1mm thick saddle)
9Credit Item for Old working Single Phase DG Set of capacity 7.5 KVA. Year of Manufacturing - 2017 of make Mahindra
10Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
11Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
12Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
13Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
14Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansin foundation trenches or drain(not exceeding 1.5 m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms foralllift including getting out the excavated soiland disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kind of soil
15Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III)derived from natural sources: 8 graded stone aggregate 40 mm nominal size from natural sources)
16Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5.3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)
17FSD Balijhori
18Supply, Installation, Testing & Commissioning of \"silent type\" new Diesel Generator set of reputed make/ manufaturer having prime power rating of 82.5 KVA, 415 volt, 0.8 lagging power factor suitable for 50 HZ, 3 phase system (conforming to the norms of CPCB IV+ upto latest amendmend) comprising of 4 Stroke Liquid cooled Diesel Engine, electric start turbocharged & intercooled developing of min. 101.3 BHP at 1500 RPM, capable of taking 10 % over loading for one hour after 12 hours of continous operation coupled with self excited and self regulated, Brush less, Synchronous alternator with H class insulation in SPDP enclosure rated at 82.5 KVA, 415 V at 1500 RPM, 3 phase 50 HZ, A.C supply with 0.8 lagging power factor, both the engine and alternator shall be mounted on a common MS base frame in Accoustic & wheather proof enclosure on suitable C.C foundation as per manufacturer drawing & design complete with Automatic mains failure control Panel (AMF) with suitable rating MCCBs including auto/ manual by-pass, battery charger, Micro-processor based Genset controllers with display for voltages & Currents, Frequency, Genset KVA, KW, KWh, KVAr, Power Factor, Lube oil pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Emergency Stop, Battery charge condition, comprises of advanced Digital AVR for improving voltage regulation & response time, Electronic Governor, Fuel tank, Residential type silencer, AVM pads fitted on base frame, First fill of lube oil, 12V DC starting system comprising of starter motors & 1 No. 12V battery including transportation, loading and unloading of the DG set. The entire set must be warranted least of 24 months / 5000 Hrs from the date of Commissioning whichever is earlier. The agency will have to fill full tank & provide permanently multi-core control cables as required with allied accessories including laying of the same before commissioning of the DG set and also including supplyingandfixingexhaustgaspipingof suitabledia.weldedblackMS,BClasspipe conformingtoIS:3589cuttorequiredlengths andinstalledwithnecessarybends,supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50mmthickwiremesh&aluminumcladding etc., The DG set should be of reputed brand and must be approved by the Engineer-in Charge and installed as per CPWD specifications.
19Supply of XLPE Power cable of size 4x95 sq.mm of 1.1 KV grade armoured Al. Cable Compulsary ISI made Confirming to IS : 7098/ Pat -I / 88 with amendment no Iof reputed make as required.
20Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required..
21Providing and fixing 25 mm X 5mm G.I Strip in 40 mm dia G.I pipe from earth electrode electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling as required.
22Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
23Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. Above 35 Sq.mm and upto 95 Sq.mm
24Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE powercable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle)Above 35 Sq.mm and upto 95 Sq.mm (Clamped with 25X3 mm MS Flat Clamp)
25Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing RCC/ HUME/ METAL pipe as required. Above 35sqmm and upto 95 sqmm.
26Credit Item for Old working Single Phase DG Set of capacity 7.5 KVA. Year of Manufacturing - 2017 of make Mahindra
27Providing and fixing precoated galvanised iron profile sheets size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
28Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
29Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
30Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
31Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansin foundation trenches or drain(not exceeding 1.5 m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms foralllift including getting out the excavated soiland disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kind of soil
32Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III)derived from natural sources: 8 graded stone aggregate 40 mm nominal size from natural sources)
33Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5.3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)
34FSD Hirakud
35Supply, Installation, Testing & Commissioning of \"silent type\" new Diesel Generator set of reputed make/ manufaturer having prime power rating of 40 KVA, 415 volt, 0.8 lagging power factor suitable for 50 HZ, 3 phase system (conforming to the norms of CPCB IV+ upto latest amendmend) comprising of 4 Stroke Liquid cooled Diesel Engine, electric start turbocharged & intercooled developing of min. 51.8 BHP at 1500 RPM, capable of taking 10 % over loading for one hour after 12 hours of continous operation coupled with self excited and self regulated, Brush less, Synchronous alternator with H class insulation in SPDP enclosure rated at 40 KVA, 415 V at 1500 RPM, 3 phase 50 HZ, A.C supply with 0.8 lagging power factor, both the engine and alternator shall be mounted on a common MS base frame in Accoustic & wheather proof enclosure on suitable C.C foundation as per manufacturer drawing & design complete with Automatic mains failure control Panel (AMF) with suitable rating MCCBs including auto/ manual by-pass, battery charger, Micro-processor based Genset controllers with display for voltages & Currents, Frequency, Genset KVA, KW, KWh, KVAr, Power Factor, Lube oil pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Emergency Stop, Battery charge condition, comprises of advanced Digital AVR for improving voltage regulation & response time, Electronic Governor, Fuel tank, Residential type silencer, AVM pads fitted on base frame, First fill of lube oil, 12V DC starting system comprising of starter motors & 1 No. 12V battery including transportation, loading and unloading of the DG set. The entire set must be warranted least of 24 months / 5000 Hrs from the date of Commissioning whichever is earlier. The agency will have to fill full tank & provide permanently multi-core control cables as required with allied accessories including laying of the same before commissioning of the DG set and also including supplyingandfixingexhaustgaspipingof suitabledia.weldedblackMS,BClasspipe conformingtoIS:3589cuttorequiredlengths andinstalledwithnecessarybends,supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50mmthickwiremesh&aluminumcladding etc., The DG set should be of reputed brand and must be approved by the Engineer-in Charge and installed as per CPWD specifications.
36Supply of XLPE Power cable of size 4 x 35 sq.mm of 1.1 KV grade armoured Al. Cable Compulsary ISI made Confirming to IS : 7098/ Pat -I / 88 with amendment no Iof reputed make as required.
37Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required..
38Providing and fixing 25 mm X 5mm G.I Strip in 40 mm dia G.I pipe from earth electrode electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling as required.
39Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
40Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. upto 35 Sq.mm
41Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE powercable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle)upto 35 Sq.mm (Clamped with 25X3 mm MS Flat Clamp
42Credit Item for Old working Single Phase DG Set of capacity 7.5 KVA. Year of Manufacturing - 2017 of make Mahindra
43Providing and fixing precoated galvanised iron profile sheets size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
44Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
45Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
46Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
47Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansin foundation trenches or drain(not exceeding 1.5 m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms foralllift including getting out the excavated soiland disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kind of soil
48Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III)derived from natural sources: 8 graded stone aggregate 40 mm nominal size from natural sources)
49Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5.3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)
50FSD Rourkela
51Supply, Installation, Testing & Commissioning of \"silent type\" new Diesel Generator set of reputed make/ manufaturer having prime power rating of 25 KVA, 415 volt, 0.8 lagging power factor suitable for 50 HZ, 3 phase system (conforming to the norms of CPCB IV+ upto latest amendmend) comprising of 4 Stroke Liquid cooled Diesel Engine, electric start turbocharged & intercooled developing of min. 30.5 BHP at 1500 RPM, capable of taking 10 % over loading for one hour after 12 hours of continous operation coupled with self excited and self regulated, Brush less, Synchronous alternator with H class insulation in SPDP enclosure rated at 25 KVA, 415 V at 1500 RPM, 3 phase 50 HZ, A.C supply with 0.8 lagging power factor, both the engine and alternator shall be mounted on a common MS base frame in Accoustic & wheather proof enclosure on suitable C.C foundation as per manufacturer drawing & design complete with Automatic mains failure control Panel (AMF) with suitable rating MCCBs including auto/ manual by-pass, battery charger, Micro-processor based Genset controllers with display for voltages & Currents, Frequency, Genset KVA, KW, KWh, KVAr, Power Factor, Lube oil pressure, Engine Temperature, RPM, Run Hours, Number of starts, Fuel Level, Auto / Manual Stop, Emergency Stop, Battery charge condition, comprises of advanced Digital AVR for improving voltage regulation & response time, Electronic Governor, Fuel tank, Residential type silencer, AVM pads fitted on base frame, First fill of lube oil, 12V DC starting system comprising of starter motors & 1 No. 12V battery including transportation, loading and unloading of the DG set. The entire set must be warranted least of 24 months / 5000 Hrs from the date of Commissioning whichever is earlier. The agency will have to fill full tank & provide permanently multi-core control cables as required with allied accessories including laying of the same before commissioning of the DG set and also including supplyingandfixingexhaustgaspipingof suitabledia.weldedblackMS,BClasspipe conformingtoIS:3589cuttorequiredlengths andinstalledwithnecessarybends,supports and clamps, anti-vibration mountings, insulation of exhaust system with mineral wool/Rockwool, 50mmthickwiremesh&aluminumcladding etc., The DG set should be of reputed brand and must be approved by the Engineer-in Charge and installed as per CPWD specifications.
52Supply of XLPE Power cable of size 4x16 sq.mm of 1.1 KV grade armoured Al. Cable Compulsary ISI made Confirming to IS : 7098/ Pat -I / 88 with amendment no Iof reputed makeas required.
53Earthing with G.I earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe of 2.7 metre long etc. with charcoal/ coke and salt as required..
54Providing and fixing 25 mm X 5mm G.I Strip in 40 mm dia G.I pipe from earth electrode electrode including connection with G.I. nut, bolt, spring, washer excavation and re-filling as required.
55Providing and fixing 25 mm X 5 mm G.I. strip on surface or in recess for connections etc. as required.
56Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size direct in ground including excavation and refilling the trench etc as required, but excluding sand cushioning and protective covering. upto 35 Sq.mm
57Laying and fixing of one No. PVC insulated & PVC sheathed/XLPE powercable of 1.1KV gradeof following size on the wall surface as reqd.(clamped with 1mm thick saddle)upto 35 Sq.mm (clamped with 1mm thick saddle)
58Credit Item for Old working Single Phase DG Set of capacity 7.5 KVA. Year of Manufacturing - 2017 of make Mahindra
59Providing and fixing precoated galvanised iron profile sheets size, shape and pitch of corrugation as approved by Engineer-in-charge)0.50 mm (+ 0.05 %) total coated thickness with zinc coating 120grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desired by Engineer-in- charge. The sheet shall be fixed using self-drilling /self-tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required.
60Providing and fixing precoated galvanised steel sheet roofing accessories 0.50 mm (+0.05 %) total coated thickness, Zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete : Ridges plain (500 - 600mm)
61Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete.
62Painting with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade : : Two or more coats on new work over an under coat of suitable shade with ordinary paint of approved brand and manufacture
63Earth work in excavation by mechanical means (Hydraulic excavator)/manual meansin foundation trenches or drain(not exceeding 1.5 m in width or 10 sqm on plan)including dressing of sides and ramming of bottoms foralllift including getting out the excavated soiland disposal of surplus excavated soil as directed with in a lead of 50 mtr. All kind of soil
64Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:4:8 (1 Cement : 4 coarse sand (zone-III)derived from natural sources: 8 graded stone aggregate 40 mm nominal size from natural sources)
65Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level : 1:1.5.3 (1 Cement : 1.5 coarse sand (zone-III) derived from natural sources: 3 graded stone aggregate 20 mm nominal size derived from natural sources)

AI Tender Summary

OUR REF NO 46102730
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 42.25 Lakhs
LAST DATE 19-11-2024
Authority
Authority Name Food Corporation Of India
Work Description Sitc Of Silent Dg Set (As Per Cpcb 4 Plu Norms) With Amf Panel Including Providing Earthing, Concrete Foundation And Providing Shed With Profile Sheet At Fsd Attabira, Fsd Balijhori, Fsd Hirakud And Fsd Rourkela Under Fci Do Sambalpur For The Fy 202
Basic Detail
Tender No EM/Engg/2024-25/04
Bidding Type Tender
Location
City attabira
State Odisha
Key Dates
Publish Date 08 Nov 2024
Submission Date 19 Nov 2024
Open Date 01 Jan 0001
Finance
Tender Value 42.25 Lakhs
Tender Fee Ref. Documents
EMD 84510
Exemption Not Available
Document List
a9626e57-aa82-47f1-a8cf-faca1fa34f6f.html
BOQ_876661.xls
MTF.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 08, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 19, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 19, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed

Tender Documents

Download All (ZIP) ↓
html

a9626e57-aa82-47f1-a8cf-faca1fa34f6f.html

xls

BOQ_876661.xls

pdf

MTF.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender