| 1 | Vacuum pump- MAKE HHV Pumps, Model no- 01SP-016-216 Sl no- 12-19-040, Displacement-17 meter cube / hr, Weight-29Kk (W/O Oil), Oil:G68 Grade or Equivalent, Capacity 01 Litre |
| 2 | Transformer Dry Type, Power:5KVA Three Phase, FREQUENCY RANGE OF OPERATION:50Hz to 400Hz, HV:280V,LV:165V,Vector Group:YNYN0, HV Taps:265 ,250,235,220V, Impedance:4%, Insulation Class: B, Insulation Level (50Hz 1 min):4kV, Tem. rise-70C, Losses- Fe-20W <(>&<), Make-Trans Power Industries |
| 3 | Support insulator for Bus duct of HVR Transformer #Type Porcelain, Total length- 312mm,#Bottom- CI metal part of Ø 60 having 4 holes of M8 tap on 46 pcd and one centre hole of M14 tap, #Top- CI metal part of Ø 50 having 4 holes of M8 tap on 36 pcd and one rehole of M10 tap. #Insulation level 90 KV or more |
| 4 | High Voltage HRC fuse link M/s Bussmann: #Model- 12ABCNA3.15, 12 Kv, 3.15 Amps with# recommended fuse clip |
| 5 | Rechargeable Battery for METREL Make 5KV Insulation Resistance Tester Model- MI-2077, Capacity- 4500 mAH, Voltage- 1.2V, Type-NiMH, Type-C, Product Code- A1046.#One Set Consist of 6 Batteries. |
| 6 | Powertech make SMPS#220VDC/24VDC 10A#Model Type 300SI#Sr No-PSPL/11-12/3414 |
| 7 | Model-8085 Reactive Transducer,3Phase 3 Wire Unbalanced,##Output : 4-12-20 mA DC Dual,##Input: 110V AC; 0-1 A, Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.2%, Range: 190.52Var lead-0-##190.52 Var lag Ordering code: 8085/228/172/251/352/17/A2/,Make : SOUTHERN TRANSDUCERS |
| 8 | Model-8075 Active Transducer,3Phase 3 Wire Unbalanced, Output : 4-20 mA DC Dual,##Input: 110V AC; 0-1 A AC, Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.2%, Range: 0-600 MW, CT ratio:20000/5A, Rated current at 0.85pf, 21KV, 500MW:16166A, PT ra : (21KV/#3) / (110V/#3) Ordering code: 8075/221/172/251/352/17/A2/0,Make : SOUTHERN TRANSDUCERS |
| 9 | Model-8091 Power Factor Transducer,3 phases, Output : 4-12-20 mA DC,##Input: 110V AC; 0-1 A AC, Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.02 pf, Range: 0.5 lead-1-0.5##lag, Ordering code: 8091/2/220/172/251/352/17/A1/0,Make : SOUTHERN TRANSDUCERS |
| 10 | Model-8066 AC Current Transducer, Output : 4-20 mA DC Single,##Input: 0-1 A AC(Transducer to be calibrated to 12mA for 1A AC input), Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.5, Ordering code:##8066/220/251/352/17/A1/0,Make : SOUTHERN TRANSDUCERS |
| 11 | Model-8061 AC Voltage Transducer ,Output : 4-20 mA DC Single,##Input: 0-110V AC(Transducer to be calibrated to 14.67mA for 110 V AC input), Input Range: 0-137.5V AC, Frequency: 50 Hz, Aux. supply: 240V AC, Accuracy Class:0.5%,##Ordering code: 8061/220/172/ 7/A1/0,Make : SOUTHERN TRANSDUCERS |
| 12 | Model-8020 DC Voltage Transducer, Output : 4-20 mA DC Dual Isolated,##Input: 0-300V DC, Aux. supply: 240V AC, Accuracy Class:0.5%,##Di-electric Test Vol. 4 KV rms for 1 min, Ordering code:##8020/221/305/09/0/1/2,Make : SOUTHERN TRANSDUCERS |
| 13 | Model-8020 DC Voltage Transducer, Output : 4-20 mA DC Dual Isolated,##Input: 0-60mV DC, Aux. supply: 240V AC, Accuracy Class:0.5%,##Di-electric Test Vol. 4 KV rms for 1 min, Ordering code:##8020/221/009/09/0/2,Make : SOUTHERN TRANSDUCERS |
| 14 | Model-8020 DC Voltage Transducer, Output : 4-20 mA DC Dual Isolated,##Input: 0-40V DC, Aux. supply: 240V AC, Accuracy Class:0.5%,##Di-electric Test Vol. 4 KV rms for 1 min, Ordering code:##8020/221/009/17/0/1/2,Make : SOUTHERN TRANSDUCERS |
| 15 | Model-8020 DC Voltage Transducer,##Output : Isolated 4-20 mA DC,Input: -15V-0-+15V DC,##Aux. supply: 240V AC, Accuracy Class:0.5%, Di-electric##Test Vol. 2 KV rms for 1 min, Ordering code:##8020/221/009/17/0/0 SA0653942230,Make : SOUTHERN TRANSDUCERS |
| 16 | Model-8020 DC Voltage Transducer, ##Output : 4-20 mA DC Single,Input: 0-10V DC, Aux. supply: 240V AC, AccuracyClass:0.2%,##Di-electric Test Vol. 1.5 KV rms for 1 min##Ordering code: 8020/220/153/17/0/0,Make : SOUTHERN TRANSDUCERS |
| 17 | FREQ. TRANSDUCER #Make : SOUTHERN TRANSDUCERS HSN Code: 90303340#Type No. : 8071 # FREQUENCY #TRANSDUCER#Output : 4-20mA DC Dual Isolated (R max: 500#)#PT Input Voltage : 110V AC #Frequency Range : 45-55Hz.#Aux#Supply : 240V AC; 50Hz#Accuracy : ±0.2% of Span# damping #Insulation Level : 3 KV AC; 50Hz for 1 minute(Between O/P#s 2#KV AC)#Ordering Code : 8071/221/172/321/17/A2/0#Dimension : 75 X 70 X 113 (L X W X H) |
| 18 | Auxiliary Relay RE 301 4 C/O S/R contacts with LED Indication Coil Voltage- 24 V DC, Jyoti make |
| 19 | AUX RELAY RE 300, 4 C/O S/R contacts with LED Indication ,#Coil Voltage- 220 V DC, Jyoti make# |
| 20 | UT Transformer Cooling Fan, Model- 45063, Sweep-450mm, Power-132W, Three Phase Motor, FLC-0.3A, RPM-900, Air Flow- 4500m3/Hr, Type of Running-Form-A, IP55, Make- Marathon Electric |
| 21 | Power Fuse 315A, Size 2 Type- VSK315, Make- Bussmann |
| 22 | Power Fuse 250A, Size 1 Type- VSF250,Make- Bussmann |
| 23 | Power Fuse 80A, Size 00 Type- VSB80,Make- Bussmann |
| 24 | Fuse NS Type 2A,Make- Bussmann |
| 25 | Fuse NS Type 4A,Make- Bussmann |
| 26 | Fuse NS Type 6 A,Make- Bussmann |
| 27 | Fuse NS Type 10 A,Make- Bussmann |
| 28 | Fuse NS Type 16 A,Make- Bussmann |
| 29 | Fuse NS Type 20 A,Make- Bussmann |
| 30 | Fuse NS Type 32A,Make- Bussmann |
| 31 | Fuse NS Type 50A,Make- Bussmann |
| 32 | Siemens make Fuse#3NW TIA6 gG 6Amps#440VAC 220VDC |
| 33 | Siemens make Fuse#3NW TIA10 gG 10Amps#440VAC 220VDC |
| 34 | Siemens make Fuse#3NW TIA25 gG 25Amps 440VAC 220VDC |
| 35 | Siemens make Circuit Breaker Miniature with Aux. Contact Block# Type 5SX52 C25 220/440V Icu 10kA acc.to IS:13947-2#Aux Contact Block: 5SX9100 HS 6A/230VAC, 1A/220VDC 1NO+1NC## |
| 36 | Siemens make Air Break (Aux) Contactor Relay#(i)01 No. Type 3TH30 40-0B Aux Contact 4 NO, Ie/AC15, System Voltage 500VAC/600VDC, COIL VOLTAGE 220VDC +10%, -15%,IEC 947, IS: 13947, with (ii) 4Nos. Of NC Add on Contact Block Type-Siemens 3TX4001-2A IS:13947 IEC 60947 with#(iii) 01 No. Surge Suprressor (Varistor) # Type- Siemens 3TX7 402-3JY1#Us 150-250 VDC |
| 37 | Siemens make Air Break (Aux) Contactor Relay#(i) 01 No. Type 3TH30 40-0A Aux Contact 4 NO, Ie/AC15, System Voltage 240VAC,10A, COIL VOLTAGE 240VAC +10%, -15%,IEC 947, IS: 13947, with (ii) 4Nos. Of NC Add on Contact Block Type-Siemens 3TX4001-2A IS:13947, C 60947# |
| 38 | ABB make (i) 2 Pole MCB with Auxiliary Contact Block.# ABB S282 UC K3A, 440VAC/440VDC,#Order Code-GH S282 0164 R0317#(ii) AUX CONTACT BLOCK-#H-11(1NO+1NC) FOR ABB S282 UC K3A, 440VAC / 440VDC MCB# |
| 39 | ABB make (i) 3Pole Motor Protection CB having O/L, Short Circuit & Single Phase Protection , Rated Thermal Current 25A, Rated Operating Voltage 690 VAC , RAted Short Cuircuit Breaking Capacity 75kA at 400V. MS325-12.5, 690VAc, AC3, Setting Range9-12.5A ( i) AUX CONTACT BLOCK- HK-11(1NO+1NC) FOR MS325-4Order Code-1SAM 101 901 R0001 |
| 40 | ABB make (i) 3Pole Motor Protection CB having O/L, Short Circuit & Single Phase Protection , Rated Thermal Current 25A, RatedOperating Voltage 690 VAC MS325-4 690VAc, Setting Range 2.5-4A Order Code-1SAM 150 000 R1008 (ii) AUX CONTACTBLOCK- HK-11(1NO+1N ) FOR MS325-4 Order Code-1SAM 101 901 R0001 |
| 41 | ABB make (i) 3Pole Motor Protection CB having O/L, Short Circuit & Single Phase Protection , Rated Thermal Current 25A, RatedOperating Voltage 690 VAC MS325-1 690VAc, Setting Range 0.63-1A Order Code-1SAM 150 000 R1005 (ii) AUX CONTACTBLOCK- HK-11(1NO+1 C) FOR MS325-1 Order Code-1SAM 101 901 R0001 |
| 42 | FULLY AUTOMATIC STAR DELTA STARTER FOR 20 HP MOTOR WITH GRP PANAL BOX SIZE 750X500X250 MM WITH SFU, PT (440/110 Volt), THERMAL O/L, POWER CONTACTOR, STAR-DELTA TIMER, ON OFF PUSH BUTTON, AND INDICATION LAMP OF ON, OFF, O/L, WATER LEVEL HIGH AND LOW ON PAN L DOOR, Make:M/s C&S / M/s ABB / M/s HENSAL / M/s PUSTRON |