| 1 | Dismantling stone Masonry/ Rubble masonry including stacking of serviceable materials and disposal of unserviceable materials. (b) in Cement. |
| 2 | Earth work in excavation in foundations trenches etc. in all kinds of soil where Pick-Jumper work is not involved and not exceeding 2.0 metres depth including dressing of bottom and sides of trenches, stacking the excavated soil clear from the edge of excavation and subsequent filling around masonry in 15 cm, layers with compaction including disposal of all surplus soil as directed within lead of 30 metres. |
| 3 | Cement concrete 1:4:8 with stone ballast.(a) With stone ballast 20mm gauge. |
| 4 | Cement concrete 1:3:6 (a) with stone ballast or shingle. |
| 5 | Providing and laying 60 mm thick factory made cement concrete interlocking Paving blocks of M-35 grade manufactured by block making machine equipped with steel mould clamped to a strong vibratory table with hydraulic pressure for compaction of concrete as per IRC SP 63 -2014 and of approved size and design / shape laid in Ordinary Grey Colour and pattern over and including 40 mm thick compacted bed of coarse sand, filling the joints with fine sand etc, all complete as per directions of Engineer-in- Charge. |
| 6 | Providing, lowering in trenches to correct radient and alignment, jointing with tyton rubber joint and cutting of reinforced cement concrete spigot and socketed pipes and specials with rubber ring ISI marekd as per IS code IS 458-2003 into trenches for all depths and laying out the same to correct alignment, gradients, levels etc. cutting of concrete beds and joints holes, supporting the pipes and specials in correct position in a suitable rigid manner while the same are being jointed and until the surrounding benchings, haunches and envelopes are completed. The pipes shall rest on the beds at all joints through their lengths and fixing of rubber ring, facing, testing the pipes for leakage and making good the same leakage and all defects to the entire satisfaction of the Engineer-in-charge including all cartage etc.B). R.C.C. Pipe NP-2 (c) 200mm i/d pipe |
| 7 | First class burnt brick work laid in cement sand mortar 1:5 in foundation and plinth. |
| 8 | Damp proof course 7.5 Cm thick cement concrete 1:2:4 with 2 coats of bitumen 20/30 penetration at 1.65 Kg per sqm laid hot and sanded. |
| 9 | First class burnt brick work laid in cement sand mortar 1:5 in first storey upto 4 metres above plinth level. |
| 10 | Centering and shuttering for sides and soffits of beam, beams, launching girders, bressumers, lintels. |
| 11 | Cement concrete 1:2:4 with stone ballast or shingle (copping).(ii) using concrete mixer volumetric type. |
| 12 | 12.5 mm thick cement plaster 1:4 |
| 13 | Finishing walls with water soluble exterior cement based paint such as snowcem, robbiacem etc. two or more coats to give an even shade. |
| 14 | Constructing Punjab Standard Drain, type house connection complete consisting of cement concrete drain moulded and laid over lime concrete foundation, rendered and finished smooth with 6mm thick rendering concrete to be of 1:2½:5 parts by volume of cement :sand: stone bajri and rendering to be 1:1 cement sand mortar.Constructing Punjab standard drain type IV. |
| 15 | Constructing Punjab Standard Drain, type I as above |
| 16 | Providing and fixing 14 gauge MS sheet garage doors with 40mmx40mmx6mm angle iron frame with diagonal braces 3.15mm gusset plates including locking arrangement with handles etc. complete in respects |
| 17 | Steel work fixed independently without connecting plates including cutting hoisting and fixing in position. (c) Tees angles & channels. |
| 18 | Supplying and fixing galvanised steel barbed wire(IS 278-1962 Type -I)weighing 9.38kg/100metre(min.) straining and fixing to any type of standard rails, straining bolts including securing with and provision of galvanised mild steel wire, staples or steel pins etc. as directed(posts and struts of wood concrete steel etc. and straining bolts shall be paid for separately). |
| 19 | Applying priming coat with metal primer on new steel or iron work including preparation of surface |
| 20 | Painting two or more coats excluding priming coat with synthetic enamel paint in all shades on wood work, metallic or plastered, concrete surface to give an even shade |