AMC Work of of 33/11 kv substations under EE,EDD, Haidergarh.
BOQ
| Sl. No. | Item Description |
| 1 | PROVIDING AND REPLACEMENT OF KV CT 600/300/5 As per RESSPO Norms. (Make CGL, PASCAL, BHEL, SCHEMER, L&T TOSHIBA, STEL ETC. |
| 2 | PROVIDING AND REPLACEMENT OF KV CT 400/200/5 As per RESSPO Norms. (Make CGL, PASCAL, BHEL, SCHEMER, L&T TOSHIBA, STEL ETC. |
| 3 | PROVIDING AND REPLACEMENT OF KV CT 200/100/5 As per RESSPO Norms.(Make CGL, PASCAL, BHEL, SCHEMER, L&T TOSHIBA, STEL ETC. |
| 4 | REPLACEMENT OF DEFECTIVE 11 KV POTENTIAL TRANSFORMER |
| 5 | SUPPLY & REPLACEMENT OF DEFECTIVE 11 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT |
| 6 | SUPPLY & REPLACEMENT OF DEFECTIVE 11 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT |
| 7 | REPLACEMENT & SUPPLY OF DEFECTIVE HT HRC FUSE FOR PT OF APPROPRIATE RATING |
| 8 | SERVICING AND REPAIRING OF ALL MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 11 KV BREAKER WARRANTY PERIOD WILL BE SIX MONTH (ALL MATERIAL REQUIRED FOR WORKING OF VCB WILL BE PROVIDED BY CONTRACTOR) |
| 9 | REPLACEMENT AND SUPPLY OF 11 KV VCB CHARGING MOTOR OF APPROPRIATE RATING |
| 10 | REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING |
| 11 | REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING |
| 12 | REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY |
| 13 | REPLACEMENT AND SUPPLY OF DEFECTIVE SPOUT |
| 14 | REPLACEMENT AND SUPPLY OF DEFECTIVE JAW (MALE/FEMALE) FOR 11 KV VCB TROLLEY |
| 15 | REPLACEMENT & SUPPLY OF DEFECTIVE INDICATOR |
| 16 | REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER |
| 17 | REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER |
| 18 | REPLACMENT & SUPPLY OF DEFECTIVE TNC SWITCH |
| 19 | REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH |
| 20 | REPLACMENT & SUPPLY OF DEFECTIVE BUZZER |
| 21 | REPLACEMENT & SUPPLY OF DEFECTIVE CLOSING COIL (24 V D.C) |
| 22 | SERVCING AND REPAIRING OF ELECTRICAL SYSTEM FOR PROPER METERING, OPENING, CLOSING & TRIPPING OF 11 KV BREAKER INCLUDING PROVIDING OF ALL NECESSARY ITEMS AND INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING AND OTHER NECESSARY ACCESSORIES. BATTRERYANDBATTERYCHARGEROVERHAULING& MAINTENANCE. WARRANTY PERIOD SIX MONTH (ALL MATERIAL REQUIRED FOR WORKING OF VCB WILL BE PROVIDED BY CONTRACTOR) |
| 23 | IN CASE OF EMERGENCY BREAKDOWN VCB REPAIRING ETC WORK LIKE CLEANING, REPAIRING AND REFITTING AFTER REMOVAL OF FAULT WITH IN 1 HOUR AFTER GETTING INFORMATION AND WARRANTY PERIOD WILL BE SIX MONTH (ALL MATERIAL REQUIRED FOR WORKING OF VCB WILL BE PROVIDED BY CONTRACTOR) |
| 24 | PROVIDING AND ERRECTION OF PIPE EARTHING VIA 2 INCH DIA GI PIPE (3MM) UPTO 40 FEET |
| 25 | The work of safe carriage of the following material from Electricity store center Barabanki to work site under the jurisdiction of EDD-HaidergarhBarabanki Approx. distance upto 60 Km. Including safe loading and unloading. |
| 26 | 33 KV O/D VCB 1250 A |
| 27 | ACSR DOG CONDUCTOR |
| 28 | LINE ISOLATOR 800A |
| 29 | 33 KV CURRENT TRANSFORMER 400/200/1 OR 200/100/1 |
| 30 | 11 KV POTENTIAL TRANSFORMER |
| 31 | 11 KV CAT-A ENERGYMETER |
| 32 | ERECTION WORK |
| 33 | INSTALLATION OF 33 KV O/D VCB 1250 A |
| 34 | ACSR DOG CONDUCTOR |
| 35 | INSTALLATION OF 33 KV line isolator 33 KV (800 Amp.) |
| 36 | REPLACEMENT OF DEFECTIVE 33 KV CURRENT TRANSFORMER 400/200/1 |
| 37 | SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL O/C + E/F IDMT Relay WITH RETROFITTING ARRANGEMENT |
| 38 | SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL MASTER RELAY WITH RETROFITTING ARRANGEMENT |
| 39 | SUPPLY & REPLACEMENT OF DEFECTIVE 33 KV PANEL AUXILARY Relay WITH RETROFITTING ARRANGEMENT |
| 40 | REPLACEMENT & Supply OF DEFECTIVE CLOSING COIL |
| 41 | REPLACEMENT & SUPPLY OF DEFECTIVE TRIPPING COIL |
| 42 | REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF BREAKER |
| 43 | REPLACEMENT & SUPPLY OF DEFECTIVE TNC SWITCH |
| 44 | REPLACEMENT OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 2*2.5 SQ MM ARMOURED CABLE |
| 45 | REPLACEMENT OF DEFECTIVE CONTROL CABLE FORM PANEL TO VCB 4*2.5 SQ MM ARMOURED CABLE |
| 46 | REPLACEMENT AND SUPPLY OF VCB CHARGING MOTOR OF APPROPRIATE RATING |
| 47 | REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT MCB OF APPROPRIATE RATING |
| 48 | REPLACEMENT AND SUPPLY OF DEFECTIVE/BURNT AUXILLARY SWITCH OF APPROPRIATE RATING |
| 49 | REPLACEMENT AND SUPPLY OF DEFECTIVE ANTIPUMPING RELAY |
| 50 | REPLACEMENT & SUPPLY OF DEFECTIVE LED INDICATOR |
| 51 | REPLACMENT & SUPPLY OF DEFECTIVE AMPERE METER |
| 52 | REPLACMENT & SUPPLY OF DEFECTIVE VOLT METER |
| 53 | REPLACMENT & SUPPLY OF DEFECTIVE LOCAL /REMOTE SWITCH |
| 54 | REPLACMENT & SUPPLY OF DEFECTIVE BUZZER |
| 55 | REPLACEMENT & SUPPLY OF DEFECTIVE WTI of Power T/F |
| 56 | REPLACEMENT & SUPPLY OF DEFECTIVE OTI of Power T/F |
| 57 | REPLACEMENT & SUPPLY OF DEFECTIVE MAGNETIC OIL GAUGE OF POWER TF |
| 58 | REPLACEMENT & SUPPLY OF DEFECTIVE BUCHOLTZ RELAY |
| 59 | REPLACEMENT & SUPPLY OF DEFECTIVE MAIN CONTACT BLOCK OF TRANSFORMER |
| 60 | SUPPLYAND ERRECTIONOF SILICA GEL BREATHER COMPLETE FOR 5/10 MVA T/F. ALL REQUIRED MATERIAL WILL BE PROVIDED BY CONTRACTOR |
| 61 | SUPPLY AND ERRECTION OF ARCHING HORN. ALL MATERIAL WILL BE PROVIDED BY CONTRACTOR. |
| 62 | SUPPLY AND ERRECTION OF COPPERMESS FOR 11 KV SIDE CONNECTION NEUTRAL. ALL MATERIAL WILL BE PROVIDED BY CONTRACTOR |
| 63 | SERVICING OF ELECTRICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS INCLUDING PROVIDING NECESSARY INTERNAL WIRING, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR CODING & SERVICING MECHANICAL SYSTEM FOR PROPER OPENING, CLOSING & TRIPPING OF 33 KV BREAKERS & SERVICING 33 KV PANEL FOR PROPER OPERATION OF OPENING, CLOSING, TRIPPING, ALARM, INDICATION OF BREAKER INCLUDING PROPER INTERNAL WIRING OF PANELS AND PROPER WIRING BETWEEN PANELS, DC CHARGER, 33 KV BREAKER, 33 KV CTs, 33 KV PTs, POWER TRANSFORMER OIL TEMPRATURE INDICATOR, WINDING TEMPRATURE INDICATOR, OIL LEVEL INDICATOR, BUCHOLTZ RELAY ETC WITH PROPER CONTOL CABLE, LUGS, FERRULES OF APPROPRIATE RATING AND COLOUR. MAINTENANCE OF LIGHTING ARRANGEMENT IN SWITCHYARD & CONTROL ROOM ALSO AND OTHER IMPORTANT WORKS RELATED TO 33/11KV SUBSTAION, WARRANTY WILL BE SIX MONTH. (ALL MATERIAL REQUIRED FOR WORKING OF VCB WILL BE PROVIDED BY CONTRACTOR) |
| 64 | SUPPLY AND REPLACEMENT OF DAMAGED HEAVY DUTY PANTHER CONDUCTOR/ PG CLAMP IN SWITCH YARD |
| 65 | SUPPLY AND REPLACEMENT OF DAMAGED ISOLATOR JAW IN COMPLETE |
| 66 | RECTIFICATION OF POWER T/F LEAKAGE |
| 67 | Centifusing of 5 MVA T/F |
| 68 | Painting of All stracture of swicht yard such as terminal gantry, Bus gantry, Line Isolator, Bus Isolators, Fuse sets, CT Stractures, Breaker Stractures, LA Stractures, power transformer ((spray painting) Etc with one code of red oxide and two cote of Almuniam paint |
| 69 | Supply and installation of 2 parallel space heater in 11kv vcb incomer and outgoing including all required accessories like thermostat and other material by contractor |
| 70 | Supply and maintenance of existing space heater in 11kv vcb incomer and outgoing including all required accessories like thermostat and other material by contractor |
AI Tender Summary
Tender Timeline
Nov 05, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedNov 11, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 12, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender