Educational and Research Institute Boards / Undertakings / PSU Closing in 0 days TDR #46023378

Tender For Up-Gradation Of Water Supply Pumping System Of Jnu Campus-Jnu/Engg./11/2024-25 (3Rd-Call)

Issued by Boards / Undertakings / PSU · delhi, Delhi
Tender Value
26.65 Lakhs
Estimated cost
Bid Submission
26 Nov 2024
0 days left
EMD
53320
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
delhi → Delhi
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Tender For Up-Gradation Of Water Supply Pumping System Of Jnu Campus-Jnu/Engg./11/2024-25 (3Rd-Call) ; Supply, Installation, Testing & Commissioning of Electrical motor driven horizontal split casing (HSC) type pump sets with following mentioned components, capacities and specifications:a) Pump:- 140 m3/hr capacitiy at head of 110 meter , 2950 RPM capacity horizontal split casing type single/double stage pump having CI casing, Bronze impeller, CI shaft sleeve, wearing rings of CI impeller, shaft of Carbon steel-40 & mechanical seal etc as required. Suction/delivery size is (125mm x 100mm)(Efficiency not less than 65% at duty point)b) Motor:- Foot mounted Copper wound squirrel cage induction motor totally enclosed fan cooled(TEFC) type of 100 HP/75 kW, 3000 RPM for operation on 415 V ± 10 % , 50 Hz, 3-phase A.C. power supply conforming to IS: 325/IS 12615:2011 and with F class insulation and coupling, coupling gaurd & f-bolts etc. as required.c) Base Plate:- Fabrication from suitable structural M.S. channel as per manufacturers/JNU Engineers recommendations for mounting both pump and motor there on duly finished and painted with synthetic enamelled paint, Nut & bolts etc. for complete motor & pump set.d) Foundation:- Suitable C.C. pump foundation as per manufacturers design anti vibration (cushy foot) heavy duty mounting pads of approved design duly finished with cement plaster etc complete as required.e) Priming Arrangement:- Priming Arrangement with suitable size of GI pipe, Union, Socket, elbow etc. complete as required from discharge line to pump casing including dismentalling of old existing pump sets, GI pipes, valves, foundation etc complete as required.f) Arrengement of suitable range of Pressure gauge.Location:- East gate pumping station (for water feeding from circular sump) 2 SITC of indoor type star-delta typestarter panel suitable for 125 H.P. pump(conforms to IS 13947(Part 4) & IEC 60947-4) complete with110 A to 125 A(AC3 duty) rating power contactor , Timer , start & stop push button , over load protection , single phase protection in 1.6 mm thick CRCA sheet with powder coated painted mounted on 50x50x6 mm size angle iron complete with earthing, connection, interconnection, sign writting etc. as requirred . 3 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbow, tees, flanges, tapers, nut-bolts, gaskets etc. and fixing the pipe on the wall/celling with suitable clamp/supportframe and painting with two or more coats of synthatic enamel paint of required shade complete as required: 4 150 mm dia 5 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following size as required: 6 150 mm dia 7 Providing, installation, testing and commissioning of non-return valve of following size confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washer etc. as required: 8 150 mm dia 9 Supply, Laying , Testing & Commissioning of 1100 V rated aluminium conductor steel wire/ strip armored XLPE power cable of following sizes as per IS-7098 part-I in the existing masonary open duct as required. 10 3½ x 95 sq. mm Armoured Alluminium cable 11 Fabrication, supply, installation, testing & commissioning of floor mounted electrical power distribution cubical panel board door, outdoor type made of 2 mm CRCA sheet fully compartmentalized duly dust & vermin proof powder coated & Phosphatized with 7 tank process, complete with following switch gear mounted thereon, earthing strip, connection , interconnection , sign writing etc. suitable mounting base plate/ angle iron i/c Brick/cement concrete foundation as per site requirement etc. as required with depth upto 500 mm1)- Incoming-a. 400 A, 50 kA, 3-Pole, D-type Thermal magnetic release MCCB- 01 No.2)- Busbar-a. 800 A capacity, 4 strip aluminium bus bar - 01 Set3)- Outgoing-a. 200 A, 50 kA,3-Pole, D-type Thermal magnetic release MCCB- 01 No.b. 160 A, 50 kA,3-Pole, D-type Thermal magnetic release MCCB- 02 No.c. 125 A, 50 kA,3-Pole, D-type Thermal magnetic release MCCB- 02 No.4)- Indication lights for R,Y,B-Phase- 01 set5)- 3-phase digital ammeter(single function meter)- 05 Nos.6)- Multifunction digital meter- 01 No. 12 Supply, Installation, Testing & Commissioning of Electrical motor driven horizontal split casing (HSC) type single stage pump sets suitable for the mentioned components, capacities and specifictona) Pump:- 140 m3/hr capacitiy at head of 65 meter , 1450 RPM capacity horizontal split casing type double stage pump having CI casing, CI impeller, CI shaft sleeve, wearing rings of CI impeller, shaft of Carbon steel-40 & mechanical seal etc as required. Suction/delivery size is (125mm x 100mm). ( Efficiency not less than 70 % at duty point)b) Motor:- Foot mounted Copper wound squirrel cage induction motor totally enclosed fan cooled(TEFC) type of 60 HP/45 kW, 1500 RPM for operation on 415 V ± 10 % , 50 Hz, 3-phase A.C. power supply conforming to IS: 325/IS 12615:2011 and with F class insulation and coupling, coupling gaurd & f-bolts etc. as required.c) Base Plate:- Fabrication from suitable structural M.S. channel as per manufacturers/JNU Engineers recommendations for mounting both pump and motor there on duly finished and painted with synthetic enamelled paint, Nut & bolts etc. for complete motor & pump set.d) Foundation:- Suitable C.C. pump foundation as per manufacturers design anti vibration (cushy foot) heavy duty mounting pads of approved design duly finished with cement plaster etc complete as required.e) Priming Arrangement:- Priming Arrangement with suitable size of GI pipe, Union, Socket, elbow etc. complete as required from discharge line to pump casing including dismentalling of old existing pump sets, GI pipes, valves, foundation etc complete as required.f) Arrengement of suitable range of Pressure gauge.Location:- Old pump House 13 SITC of indoor type star-delta typestarter panel suitable for 75 H.P. pump(conforms to IS 13947(Part 4) & IEC 60947-4) complete with70 A to 100 A(AC3 duty) rating power contractor , Timer , start & stop push button , over load protection , single phase protection in 1.6 mm thick CRCA sheet with powder coated painted mounted on 50x50x6 mm size angle iron complete with earthing, connection, interconnection, sign writting etc. as requirred . 14 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbow, tees, flanges, tapers, nut-bolts, gaskets etc. and fixing the pipe on the wall/celling with suitable clamp/supportframe and painting with two or more coats of synthatic enamel paint of required shade complete as required: 15 100 mm dia 16 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following size as required: 17 100 mm dia 18 Providing, installation, testing and commissioning of non-return valve of following size confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washer etc. as required: 19 100 mm dia 20 Supply, Installation, Testing & Commissioning of Electrical motor driven horizontal split casing (HSC) type pump sets with following mentioned components, capacities and specification:a) Pump:- 140 m3/hr capacitiy at head of 90 meter , 2950 RPM capacity horizontal split casing type single/double stage pump having CI casing, Bronze impeller, CI shaft sleeve, wearing rings of CI impeller, shaft of Carbon steel-40 & mechanical seal etc as required. Suction/delivery size is (125mm x 100mm). ( Efficiency not less than 70 % at duty point)b) Base Plate:- Fabrication from suitable structural M.S. channel as per manufacturers/JNU Engineers recommendations for mounting both pump and motor there on duly finished and painted with synthetic enamelled paint, Nut & bolts etc. for complete motor & pump set.c) Foundation:- Suitable C.C. pump foundation as per manufacturers design anti vibration (cushy foot) heavy duty mounting pads of approved design duly finished with cement plaster etc.d) Priming Arrangement:- Priming Arrangement with suitable size of GI pipe, Union, Socket, elbow etc. complete as required from discharge line to pump casing including dismentalling of old existing pump sets, GI pipes, valves, foundation etc complete as required.e) Arrengement of suitable range of Pressure gauge.f) The pump shall be coupled with existing 75 HP motor with suitable coupling and other accessories to make the complete pump set functional as per site requirement.Location:- East gate pumping station (for water feeding from rectangular sump)

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 08-Nov-2024 EE (E) Technical Bid 26-Nov-2024
2 08-Nov-2024 EE (E) Date 26-Nov-2024

BOQ

Name of Work:- Upgradation of Water Supply Pumping System of JNU Campus.
Sl. No. Item Description
1Supply, Installation, Testing & Commissioning of Electrical motor driven horizontal split casing (HSC) type pump sets with following mentioned components, capacities and specifications:a) Pump:- 140 m3/hr capacitiy at head of 110 meter , 2950 RPM capacity horizontal split casing type single/double stage pump having CI casing, Bronze impeller, CI shaft sleeve, wearing rings of CI impeller, shaft of Carbon steel-40 & mechanical seal etc as required. Suction/delivery size is (125mm x 100mm)(Efficiency not less than 65% at duty point)b) Motor:- Foot mounted Copper wound squirrel cage induction motor totally enclosed fan cooled(TEFC) type of 100 HP/75 kW, 3000 RPM for operation on 415 V ± 10 % , 50 Hz, 3-phase A.C. power supply conforming to IS: 325/IS 12615:2011 and with F class insulation and coupling, coupling gaurd & f-bolts etc. as required.c) Base Plate:- Fabrication from suitable structural M.S. channel as per manufacturer\"s/JNU Engineer\"s recommendations for mounting both pump and motor there on duly finished and painted with synthetic enamelled paint, Nut & bolts etc. for complete motor & pump set.d) Foundation:- Suitable C.C. pump foundation as per manufacturer\"s design anti vibration (cushy foot) heavy duty mounting pads of approved design duly finished with cement plaster etc complete as required.e) Priming Arrangement:- Priming Arrangement with suitable size of GI pipe, Union, Socket, elbow etc. complete as required from discharge line to pump casing including dismentalling of old existing pump sets, GI pipes, valves, foundation etc complete as required.f) Arrengement of suitable range of Pressure gauge.Location:- East gate pumping station (for water feeding from circular sump)
2SITC of indoor type star-delta typestarter panel suitable for 125 H.P. pump(conforms to IS 13947(Part 4) & IEC 60947-4) complete with110 A to 125 A(AC3 duty) rating power contactor , Timer , start & stop push button , over load protection , single phase protection in 1.6 mm thick CRCA sheet with powder coated painted mounted on 50x50x6 mm size angle iron complete with earthing, connection, interconnection, sign writting etc. as requirred .
3Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbow, tees, flanges, tapers, nut-bolts, gaskets etc. and fixing the pipe on the wall/celling with suitable clamp/supportframe and painting with two or more coats of synthatic enamel paint of required shade complete as required:
4150 mm dia
5Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following size as required:
6150 mm dia
7Providing, installation, testing and commissioning of non-return valve of following size confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washer etc. as required:
8150 mm dia
9Supply, Laying , Testing & Commissioning of 1100 V rated aluminium conductor steel wire/ strip armored XLPE power cable of following sizes as per IS-7098 part-I in the existing masonary open duct as required.
103½ x 95 sq. mm Armoured Alluminium cable
11Fabrication, supply, installation, testing & commissioning of floor mounted electrical power distribution cubical panel board door, outdoor type made of 2 mm CRCA sheet fully compartmentalized duly dust & vermin proof powder coated & Phosphatized with 7 tank process, complete with following switch gear mounted thereon, earthing strip, connection , interconnection , sign writing etc. suitable mounting base plate/ angle iron i/c Brick/cement concrete foundation as per site requirement etc. as required with depth upto 500 mm1)- Incoming-a. 400 A, 50 kA, 3-Pole, D-type Thermal magnetic release MCCB- 01 No.2)- Busbar-a. 800 A capacity, 4 strip aluminium bus bar - 01 Set3)- Outgoing-a. 200 A, 50 kA,3-Pole, D-type Thermal magnetic release MCCB- 01 No.b. 160 A, 50 kA,3-Pole, D-type Thermal magnetic release MCCB- 02 No.c. 125 A, 50 kA,3-Pole, D-type Thermal magnetic release MCCB- 02 No.4)- Indication lights for R,Y,B-Phase- 01 set5)- 3-phase digital ammeter(single function meter)- 05 Nos.6)- Multifunction digital meter- 01 No.
12Supply, Installation, Testing & Commissioning of Electrical motor driven horizontal split casing (HSC) type single stage pump sets suitable for the mentioned components, capacities and specifictona) Pump:- 140 m3/hr capacitiy at head of 65 meter , 1450 RPM capacity horizontal split casing type double stage pump having CI casing, CI impeller, CI shaft sleeve, wearing rings of CI impeller, shaft of Carbon steel-40 & mechanical seal etc as required. Suction/delivery size is (125mm x 100mm). ( Efficiency not less than 70 % at duty point)b) Motor:- Foot mounted Copper wound squirrel cage induction motor totally enclosed fan cooled(TEFC) type of 60 HP/45 kW, 1500 RPM for operation on 415 V ± 10 % , 50 Hz, 3-phase A.C. power supply conforming to IS: 325/IS 12615:2011 and with F class insulation and coupling, coupling gaurd & f-bolts etc. as required.c) Base Plate:- Fabrication from suitable structural M.S. channel as per manufacturer\"s/JNU Engineer\"s recommendations for mounting both pump and motor there on duly finished and painted with synthetic enamelled paint, Nut & bolts etc. for complete motor & pump set.d) Foundation:- Suitable C.C. pump foundation as per manufacturer\"s design anti vibration (cushy foot) heavy duty mounting pads of approved design duly finished with cement plaster etc complete as required.e) Priming Arrangement:- Priming Arrangement with suitable size of GI pipe, Union, Socket, elbow etc. complete as required from discharge line to pump casing including dismentalling of old existing pump sets, GI pipes, valves, foundation etc complete as required.f) Arrengement of suitable range of Pressure gauge.Location:- Old pump House
13SITC of indoor type star-delta typestarter panel suitable for 75 H.P. pump(conforms to IS 13947(Part 4) & IEC 60947-4) complete with70 A to 100 A(AC3 duty) rating power contractor , Timer , start & stop push button , over load protection , single phase protection in 1.6 mm thick CRCA sheet with powder coated painted mounted on 50x50x6 mm size angle iron complete with earthing, connection, interconnection, sign writting etc. as requirred .
14Providing, laying, testing & commissioning of \"C\" class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbow, tees, flanges, tapers, nut-bolts, gaskets etc. and fixing the pipe on the wall/celling with suitable clamp/supportframe and painting with two or more coats of synthatic enamel paint of required shade complete as required:
15100 mm dia
16Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following size as required:
17100 mm dia
18Providing, installation, testing and commissioning of non-return valve of following size confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washer etc. as required:
19100 mm dia
20Supply, Installation, Testing & Commissioning of Electrical motor driven horizontal split casing (HSC) type pump sets with following mentioned components, capacities and specification:a) Pump:- 140 m3/hr capacitiy at head of 90 meter , 2950 RPM capacity horizontal split casing type single/double stage pump having CI casing, Bronze impeller, CI shaft sleeve, wearing rings of CI impeller, shaft of Carbon steel-40 & mechanical seal etc as required. Suction/delivery size is (125mm x 100mm). ( Efficiency not less than 70 % at duty point)b) Base Plate:- Fabrication from suitable structural M.S. channel as per manufacturer\"s/JNU Engineer\"s recommendations for mounting both pump and motor there on duly finished and painted with synthetic enamelled paint, Nut & bolts etc. for complete motor & pump set.c) Foundation:- Suitable C.C. pump foundation as per manufacturer\"s design anti vibration (cushy foot) heavy duty mounting pads of approved design duly finished with cement plaster etc.d) Priming Arrangement:- Priming Arrangement with suitable size of GI pipe, Union, Socket, elbow etc. complete as required from discharge line to pump casing including dismentalling of old existing pump sets, GI pipes, valves, foundation etc complete as required.e) Arrengement of suitable range of Pressure gauge.f) The pump shall be coupled with existing 75 HP motor with suitable coupling and other accessories to make the complete pump set functional as per site requirement.Location:- East gate pumping station (for water feeding from rectangular sump)

AI Tender Summary

OUR REF NO 46023378
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE 26.65 Lakhs
LAST DATE 26-11-2024
Authority
Authority Name Jawaharlal Nehru University
Work Description Tender For Up-Gradation Of Water Supply Pumping System Of Jnu Campus-Jnu/Engg./11/2024-25 (3Rd-Call) ; Supply, Installation, Testing & Commissioning of Electrical motor driven horizontal split casing (HSC) type pump sets with following mentioned components, capacities and specifications:a) Pump:- 140 m3/hr capacitiy at head of 110 meter , 2950 RPM capacity horizontal split casing type single/double stage pump having CI casing, Bronze impeller, CI shaft sleeve, wearing rings of CI impeller, shaft of Carbon steel-40 & mechanical seal etc as required. Suction/delivery size is (125mm x 100mm)(Efficiency not less than 65% at duty point)b) Motor:- Foot mounted Copper wound squirrel cage induction motor totally enclosed fan cooled(TEFC) type of 100 HP/75 kW, 3000 RPM for operation on 415 V ± 10 % , 50 Hz, 3-phase A.C. power supply conforming to IS: 325/IS 12615:2011 and with F class insulation and coupling, coupling gaurd & f-bolts etc. as required.c) Base Plate:- Fabrication from suitable structural M.S. channel as per manufacturers/JNU Engineers recommendations for mounting both pump and motor there on duly finished and painted with synthetic enamelled paint, Nut & bolts etc. for complete motor & pump set.d) Foundation:- Suitable C.C. pump foundation as per manufacturers design anti vibration (cushy foot) heavy duty mounting pads of approved design duly finished with cement plaster etc complete as required.e) Priming Arrangement:- Priming Arrangement with suitable size of GI pipe, Union, Socket, elbow etc. complete as required from discharge line to pump casing including dismentalling of old existing pump sets, GI pipes, valves, foundation etc complete as required.f) Arrengement of suitable range of Pressure gauge.Location:- East gate pumping station (for water feeding from circular sump) 2 SITC of indoor type star-delta typestarter panel suitable for 125 H.P. pump(conforms to IS 13947(Part 4) & IEC 60947-4) complete with110 A to 125 A(AC3 duty) rating power contactor , Timer , start & stop push button , over load protection , single phase protection in 1.6 mm thick CRCA sheet with powder coated painted mounted on 50x50x6 mm size angle iron complete with earthing, connection, interconnection, sign writting etc. as requirred . 3 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbow, tees, flanges, tapers, nut-bolts, gaskets etc. and fixing the pipe on the wall/celling with suitable clamp/supportframe and painting with two or more coats of synthatic enamel paint of required shade complete as required: 4 150 mm dia 5 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following size as required: 6 150 mm dia 7 Providing, installation, testing and commissioning of non-return valve of following size confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washer etc. as required: 8 150 mm dia 9 Supply, Laying , Testing & Commissioning of 1100 V rated aluminium conductor steel wire/ strip armored XLPE power cable of following sizes as per IS-7098 part-I in the existing masonary open duct as required. 10 3½ x 95 sq. mm Armoured Alluminium cable 11 Fabrication, supply, installation, testing & commissioning of floor mounted electrical power distribution cubical panel board door, outdoor type made of 2 mm CRCA sheet fully compartmentalized duly dust & vermin proof powder coated & Phosphatized with 7 tank process, complete with following switch gear mounted thereon, earthing strip, connection , interconnection , sign writing etc. suitable mounting base plate/ angle iron i/c Brick/cement concrete foundation as per site requirement etc. as required with depth upto 500 mm1)- Incoming-a. 400 A, 50 kA, 3-Pole, D-type Thermal magnetic release MCCB- 01 No.2)- Busbar-a. 800 A capacity, 4 strip aluminium bus bar - 01 Set3)- Outgoing-a. 200 A, 50 kA,3-Pole, D-type Thermal magnetic release MCCB- 01 No.b. 160 A, 50 kA,3-Pole, D-type Thermal magnetic release MCCB- 02 No.c. 125 A, 50 kA,3-Pole, D-type Thermal magnetic release MCCB- 02 No.4)- Indication lights for R,Y,B-Phase- 01 set5)- 3-phase digital ammeter(single function meter)- 05 Nos.6)- Multifunction digital meter- 01 No. 12 Supply, Installation, Testing & Commissioning of Electrical motor driven horizontal split casing (HSC) type single stage pump sets suitable for the mentioned components, capacities and specifictona) Pump:- 140 m3/hr capacitiy at head of 65 meter , 1450 RPM capacity horizontal split casing type double stage pump having CI casing, CI impeller, CI shaft sleeve, wearing rings of CI impeller, shaft of Carbon steel-40 & mechanical seal etc as required. Suction/delivery size is (125mm x 100mm). ( Efficiency not less than 70 % at duty point)b) Motor:- Foot mounted Copper wound squirrel cage induction motor totally enclosed fan cooled(TEFC) type of 60 HP/45 kW, 1500 RPM for operation on 415 V ± 10 % , 50 Hz, 3-phase A.C. power supply conforming to IS: 325/IS 12615:2011 and with F class insulation and coupling, coupling gaurd & f-bolts etc. as required.c) Base Plate:- Fabrication from suitable structural M.S. channel as per manufacturers/JNU Engineers recommendations for mounting both pump and motor there on duly finished and painted with synthetic enamelled paint, Nut & bolts etc. for complete motor & pump set.d) Foundation:- Suitable C.C. pump foundation as per manufacturers design anti vibration (cushy foot) heavy duty mounting pads of approved design duly finished with cement plaster etc complete as required.e) Priming Arrangement:- Priming Arrangement with suitable size of GI pipe, Union, Socket, elbow etc. complete as required from discharge line to pump casing including dismentalling of old existing pump sets, GI pipes, valves, foundation etc complete as required.f) Arrengement of suitable range of Pressure gauge.Location:- Old pump House 13 SITC of indoor type star-delta typestarter panel suitable for 75 H.P. pump(conforms to IS 13947(Part 4) & IEC 60947-4) complete with70 A to 100 A(AC3 duty) rating power contractor , Timer , start & stop push button , over load protection , single phase protection in 1.6 mm thick CRCA sheet with powder coated painted mounted on 50x50x6 mm size angle iron complete with earthing, connection, interconnection, sign writting etc. as requirred . 14 Providing, laying, testing & commissioning of C class heavy duty MS pipe conforming to IS 3589/IS 1239 including Welding, fittings like elbow, tees, flanges, tapers, nut-bolts, gaskets etc. and fixing the pipe on the wall/celling with suitable clamp/supportframe and painting with two or more coats of synthatic enamel paint of required shade complete as required: 15 100 mm dia 16 Supplying, fixing, testing & commissioning of double flanged sluice valve of rating PN 1.6 with non rising spindle, bronze/gun metal seat, ISI marked complete with nuts, bolts, washers, gaskets and conforming to IS 780 of following size as required: 17 100 mm dia 18 Providing, installation, testing and commissioning of non-return valve of following size confirming to IS: 5312 complete with rubber gasket, GI bolts, nuts, washer etc. as required: 19 100 mm dia 20 Supply, Installation, Testing & Commissioning of Electrical motor driven horizontal split casing (HSC) type pump sets with following mentioned components, capacities and specification:a) Pump:- 140 m3/hr capacitiy at head of 90 meter , 2950 RPM capacity horizontal split casing type single/double stage pump having CI casing, Bronze impeller, CI shaft sleeve, wearing rings of CI impeller, shaft of Carbon steel-40 & mechanical seal etc as required. Suction/delivery size is (125mm x 100mm). ( Efficiency not less than 70 % at duty point)b) Base Plate:- Fabrication from suitable structural M.S. channel as per manufacturers/JNU Engineers recommendations for mounting both pump and motor there on duly finished and painted with synthetic enamelled paint, Nut & bolts etc. for complete motor & pump set.c) Foundation:- Suitable C.C. pump foundation as per manufacturers design anti vibration (cushy foot) heavy duty mounting pads of approved design duly finished with cement plaster etc.d) Priming Arrangement:- Priming Arrangement with suitable size of GI pipe, Union, Socket, elbow etc. complete as required from discharge line to pump casing including dismentalling of old existing pump sets, GI pipes, valves, foundation etc complete as required.e) Arrengement of suitable range of Pressure gauge.f) The pump shall be coupled with existing 75 HP motor with suitable coupling and other accessories to make the complete pump set functional as per site requirement.Location:- East gate pumping station (for water feeding from rectangular sump)
Basic Detail
Tender No JNU/Engg./11/2024-25
Bidding Type Tender
Location
City delhi
State Delhi
Key Dates
Publish Date 08 Nov 2024
Submission Date 26 Nov 2024
Open Date 28 Nov 2024
Finance
Tender Value 26.65 Lakhs
Tender Fee Ref. Documents
EMD 53320
Exemption Not Available
Document List
ceeb8c25-d503-4c53-aa1f-3ec84d0424e3.html
BOQ_875697.xls
Correction_Slip_GCC_Maint_1.pdf
Details_of_corrigendum_ad_2.pdf
GCC_MaintenanceWorks_2023.pdf
NITFolder.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 08, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 26, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 26, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 26, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 28, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

ceeb8c25-d503-4c53-aa1f-3ec84d0424e3.html

xls

BOQ_875697.xls

pdf

Correction_Slip_GCC_Maint_1.pdf

pdf

Details_of_corrigendum_ad_2.pdf

pdf

GCC_MaintenanceWorks_2023.pdf

pdf

NITFolder.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender