Power Boards / Undertakings / PSU Closing in 0 days TDR #46018227

Tender For Ht And Lt Line Extension And Improvement Works In North Annur Sub Division

Issued by Boards / Undertakings / PSU · annur, Tamil Nadu
Tender Value
Ref. Documents
Estimated cost
Bid Submission
14 Nov 2024
0 days left
EMD
15000
Bank guarantee accepted
Document Fee
Ref. Documents
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
annur → Tamil Nadu
EMD Exemption
Available
Quantity
Not Available

Project Description

Ht And Lt Line Extension And Improvement Works In North Annur Sub Division Ht And Lt Line Extension And Improvement Works In North Annur Sub Division Of Avinashi Division

BOQ

Name of Work: HT & LT Line Extension, Improvement and Maintenance Works in North Annur Sub-division of Avinashi Division
Sl. No. Item Description
1Running Works Contract Items (OH + UG + SS Works)
2Transportation of all type of poles by vehicle (for all sizes of poles including loading and unloading) - For a lead upto 5 KM
3Transportation of all type of poles by vehicle (for all sizes of poles including loading and unloading) - For a lead of every KM above 5 KM
4Transportation of all types and sizes of poles and other associated materials from road side to pole pit and vice versa upto 0.50 KM
5Transporting of distribution transformer / metering set from stores to office / site upto 10 KM distance by engaging 1 Ton capacity Minidor (Lorry)
6Transporting of distribution transformer / metering set from stores to office / site above 10 KM distance by engaging 1 Ton capacity Minidor (Lorry)
7Transporting of line materials from stores to office / site upto 10 KM distance by engaging 1 Ton capacity Minidor (Lorry)
8Transporting of line materials from stores to office / site above 10 KM distance by engaging 1 Ton capacity Minidor (Lorry)
9Loading of REC, RCC, PSC pole upto 8.00 m length
10Loading of all REC, RCC, PSC pole above 8.00 m length
11Loading of metal poles all sizes
12Unloading of REC, RCC, PSC pole upto 8.00 m length
13Unloading of all REC, RCC, PSC pole above 8.00 m length
14Unloading of metal poles all sizes
15Loading of distribution transformer upto 100 KVA
16Loading of distribution transformer above 100 KVA and below 500 KVA
17Loading of distribution transformer 500 KVA
18Unloading of distribution transformer upto 100 KVA
19Unloading of distribution transformer above 100 KVA and below 500 KVA
20Unloading of distribution transformer 500 KVA
21Loading of meteing sets of all ratios
22Unloading of meteing sets of all ratios
23Loading of line materials
24Unloading of line materials
25Excavation & backfilling of pole pit for pole upto 8.00 m length by using JCB / manual
26Excavation & backfilling of pole pit for pole above 8.00 m length by using JCB / manual
27Excavation & backfilling of pole pit in hard soil (common to all size of poles)
28Excavation & backfilling of pole pit in areas of medium rock and dense medium rock requires blasting (common to all size of poles)
29Excavation & backfilling of pole pit in rocky area (common to all size of poles) by blasting / manual
30Excavation & backfilling of structure pole pit 3 x 3 x 6 feet by using JCB or Manual for single pole DT structure
31Erection of RCC, REC, PSC pole upto 8.00 m length by using crane / manual
32Erection of RCC, REC, PSC pole above 8.00 m length by using crane / manual
33Erection of metal support above 9 m / RSJ / rail pole / tubular pole
34Mass concreting of pole with 1:4:8 mix using 40 mm jally including curing (material + labour) for a size of 0.45 x 0.45 x 1.2 m
35Sleeve concreting with 1:4:8 mix using 40 mm jally including curing (material + labour)
36Stay concreting with 1:4:8 mix using 40 mm jally including curing (material + labour)
37Earthing of pole with GI wires 4 or 6 SWG by coil earthing
38Provision of spike including earthing arrangement
39Pipe earthing including excavation of earth pit and fixing earth pipe 3 m length
40Excavation & backfilling of stay pit of 4.5 to 5 feet depth using JCB / Manual
41Excavation & back filling of stay pit per location - hard rock without blasting
42Excavation & back filling of stay pit per location - medium rock and dense medium rock requires blasting
43Excavation & back filling of stay pit per location - hard rock requires blasting
44Erection of stay set complete with fixing up stay wire Eye, Bow, Guy Shackle, Binding etc.
45Erection of additional stay in the same stay rod, excluding excavation of stay pit and burial of stay rod
46Replacement of stay rod only (including stay pit excavation, refilling & erection)
47Replacement of guy shackle only in existing stay
48Fixing of V cross arm 3.5 feet
49Fixing of V cross arm 4.5 feet
50Fixing of V cross arm 5 feet
51Fixing of LT single phase cross arm
52Fixing of LT 3 phase cross arm
53Fixing of HT / LT TI fitting
54Fixing of 11 KV porcelain pin insulator with pin or polymer composite pin insulator
55Fixing of 22 KV porcelain pin insulator with pin or polymer composite pin insulator
56Fixing of 33 KV porcelain pin insulator with pin or polymer composite pin insulator
57Fixing of LT pin insulator
58Fixing of HT disc 11 KV
59Fixing of HT disc 22 KV
60Fixing of HT disc 33 KV
61Fixing of LT shackle
62Fixing of aluminium knob
63Fixing of HT LAS (3 Nos.)
64Fixing of LT LAS (3 Nos.)
65Fixing of guarding cross arm
66Fixing of tapping channel cross arm
67Fixing of double channel cross arm
68Fixing of open type fuse unit
69Paving and stringing of conductor of sizes upto 7/2.59 mm ACSR or other equivalent conductor (for Route Length per Phase)
70Paving and stringing of conductor of above 7/2.59 mm ACSR or other equivalent conductor upto 7/3.35 mm ACSR or other equivalent conductor (for Route Length per Phase)
71Paving and stringing of conductor of 7/4.09 mm ACSR or other equivalent conductor (for Route Length per Phase)
72Paving and stringing of conductor of 6/4.72 + 7/1.57 (Dog) or other equivalent conductor
73Paving and stringing of conductor of one run of PVC cable line of all sizes with GI wire and reel insulator
74Provision of guarding arrangement with two numbers earth pits excluding stay set erection - Flat guarding
75Provision of guarding arrangement - Split neutral guarding
76Erection of 11 / 22 KV AB switch (Horizontal)
77Erection of 11 / 22 KV AB switch (Vertical)
78Erection of HG Fuse Set, 3 Nos. (in Double Pole or Single Pole Structure)
79Erection of top channel for double pole DT structure
80Erection of bed channel 2 Nos. for double pole DT structure
81Erection of belting angle 2 Nos. for double pole DT structure
82Erection of cross bracing set for double pole DT structure
83Structure earthing complete with 3 pits and earth loops for double pole DT structure
84HT & LT LAS fixing and jumpering complete for double pole DT structure
85Fixing of support insulator angle and erection of 3 Nos. pin insulator for double pole DT structure
86HT jumpering complete for double pole DT structure
87Painting of all clamps and other iron materials and painting of structure pole for double pole DT structure
88LT bus arrangement for double pole DT structure
89DT yard cleaning and making uniform surface for double pole DT structure
90Erection of double pole DT structure complete as per TNEB standard including painting, feeders arrangement, colour washing of poles etc., fixing of HT / LT LAS and jumpering, 3 Nos. earth pits with earth trough except erection of DT (as per enclosed split up)
91Erection of tapping channel for single pole DT structure
92Erection of transformer bed structure for single pole DT structure
93Structure earthing complete with 3 pits and earth loops for single pole DT structure
94HT jumpering complete for single pole DT structure
95Painting of all clamps, other materials and painting of structure pole for single pole DT structure
96LT cable arrangement for single pole DT structure
97Erection of central supporting arrangement for single pole DT structure
98Erection of 11 KV single pole structure completewithout centre support without erection of DT (as per enclosed split up)
99Erection of 11 KV single pole structure complete with centre support without erection of DT (as per enclosed split up)
100Fixing of danger board
101Erection of distribution transformer at structure - Upto 25 KVA
102Erection of distribution transformer at structure - Above 25 KVA to 100 KVA
103Erection of distribution transformer at structure - Above 100 KVA to 250 KVA
104Erection of distribution transformer at structure - 500 KVA and above
105Erection of Integrated DT Metering Arrangements / Whole Current Meter
106Fixing of Modem including accessories
107Erection of metering set 11 KV / 22 KV
108Dismantling of RCC, REC, PSC & metal pole of all sizes including the closing of the pit
109Destruction of pole concreting at site
110Retrieving grill from deteriorated RCC pole
111Breaking the mass concrete of all supports
112Dismantling of stay set complete including stay rod
113Dismantling of stay set complete without stay rod
114Dismantling of conductor of size upto 7/2.59 mm including transporting the conductors to the nearest road side and stocking in coils
115Dismantling of conductor of size above 7/2.59 mm and upto 7/3.35 mm including transporting the conductors to the nearest road side and stocking in coils
116Dismantling of conductor of size 7/4.09 mm including transporting the conductors to the nearest road side and stocking in coils
117Dismantling of conductor of size 6/4.72 + 7/1.57 (Dog) or other equivalent conductor
118Dismantling of guarding arrangement - Flat guarding
119Dismantling of guarding arrangement - Split neutral guarding
120Dismantling of V cross arm 3.5 feet
121Dismantling of V cross arm 4.5 feet
122Dismantling of V cross arm 5 feet
123Dismantling of LT single phase cross arm
124Dismantling of LT 3 phase cross arm
125Dismantling of HT / LT TI fitting
126Dismantling of HT pin insulator with pin 11 KV
127Dismantling of HT pin insulator with pin 22 KV
128Dismantling of HT pin insulator with pin 33 KV
129Dismantling of LT pin with insulator
130Dismantling of HT disc 11 KV with metal parts
131Dismantling of HT disc 22 KV with metal parts
132Dismantling of HT disc 33 KV with metal parts
133Dismantling of LT shackle with metal parts
134Dismantling of aluminium knob
135Dismantling of HT LAS (3 Nos.)
136Dismantling of LT LAS (3 Nos.)
137Dismantling of guarding cross arm
138Dismantling of tapping channel cross arm
139Dismantling of double channel cross arm
140Dismantling of open type fuse unit
141Dismantling of 11 / 22 KV AB switch (Horizontal)
142Dismantling of 11 / 22 KV AB switch (Vertical)
143Dismantling of HG Fuse Set (3 Nos.)
144Dismantling of top channel from double pole DT structure
145Dismantling of bed channel 2 Nos. from double pole DT structure
146Dismantling of belting angle 2 Nos. from double pole DT structure
147Dismantling of structure earthing complete of double pole DT structure
148Dismantling of HT & LT LAS and jumpering complete for double pole DT structure
149Dismantling of support insulator angle and 3 Nos. pin insulator from double pole DT structure
150Dismantling of HT jumpering complete of double pole DT structure
151Dismantling of LT bus arrangement from double pole DT structure
152Dismantling of danger board from double pole DT structure
153Dismantling of tapping channel from single pole DT structure
154Dismantling of transformer bed structure from single pole DT structure
155Dismantling of structure earthing complete from single pole DT structure
156Dismantling of HT jumpering complete of single pole DT structure
157Dismantling of LT cable arrangement from single pole DT structure
158Dismantling of danger board from single pole DT structure
159Dismantling of central supporting arrangement from single pole DT structure
160Dismantling of 11 KV single pole structure completewithout centre support
161Dismantling of 11 KV single pole structure complete with centre support
162Releasing of DT below 200 KVA from structure
163Releasing of DT 200 KVA & above but below 500 KVA from structure
164Releasing of DT 500 KVA from strcuture
165Dismantling of Integrated DT Metering Arrangements / Whole Current Meter
166Dismantling of Modem including accessories
167Releasing of metering set 11 KV / 22 KV from strcuture
168Manufacturing of special type clamps for rail poles, RS joists, tubular pole, distribution transformer strucutre with material
169Alteration of back / stay clamp to suit works
170Drilling of hole in the structure materials, clamps, etc.,
171AB switch or open type side arm stud cutting and drilling holes
172Cutting of flat per cutting
173Cutting of channel per cutting
174Cutting of angle per cutting
175Cutting of pipe per cutting
176TI fitting welding with clamps
177Cutting of RS joist pole
178Welding in RS joist pole
179Manufacturing of earth pipe clamp for structure including of drilling holes and welding with earth pipe
180Fixing of one set of street light fixture with clamp and fitting of all sizes including cable jumpering and including transportation
181Provision of street light switching arrangement including fixing of meter, wiring & service board etc.
182Fixing of street light
183Dismantling of street light switch box with pipe
184Dismantling of one set of street light fixture with clamp and fitting of all types
185Erection of MV / sodium vapour lamp including wiring and fixing at street light location including transportation
186Dismantling of MV / sodium vapour lamp including wiring
187Replacing the worn out service connection cables
188Releasing and re-erection of single phase SC wire [during conductor or support change]
189Releasing and re-erection of 3 phase SC wire [during conductor or support change]
190Dismantling and fixing of Single Phase Meter
191Dismantling ad fixing of Three Phase Meter
192Providing of line spacers in LT line 1 phase
193Providing of line spacers in LT line 3 phase
194Fixing of LT shunt capacitor
195Numbering of pole including base painting and with cost of paint
196Painting of distribution transformer of all capacities (paint to be supplied by the TANGEDCO) including cleaning of DT
197Painting of cement poles by distember coating including cost of distember
198Painting of RSJ / tubular pole including cross arms, TI fittings, single coating
199Painting of pole at ground
200Painting of transformer structure poles with two coats for each structure
201Painting of structure materials, distribution transformers with aluminium paint of structure poles and writing of transformer details (Brush to be owned by the contractor) (Paint to be supplied by Department)
202Service connection details painting
203Setting right the leaning pole in HT / LT at pin point location
204Setting right the leaning pole in HT / LT at cutpoint location
205Replacement of earthpipe per location
206Replacing the corroded earth pipes of transformer structure and replacing the earth wire completely with aluminium lugs for termination
207DT yard cleaning
208Cleaning of RMU
209Cleaning of Ring Fencing
210Leveling of ground using Bul Dozer
211Clearing of branches / trees with JCB
212Engaging crane per hour (for handling of poles, metering set, DT, etc.)
213Engaging JCB per hour (for extension works & maintenance works etc.)
214Removing weed in substation yard / office premises
215Bush clearance out side substation yard / office premises (light)
216Jungle clearance such as kattu karuvai in the various area without uprooting
217Jungle clearance such as kattu karuvai in the various area with uprooting
218Clearing of tree branches of coconut tree
219Clearing of tree branches of neem, tamarin, country, etc.,
220Distribution Transformer Maintenance - Silica Gel Replacement, Clamps Tightness, Busbar Maintenance, , HG Fuse Maintenance, AB Switch Maintenance, LT Open Type Maintenance, Inspection of Earthing & Tightness, Cleaning & Checking of DT Metering Box, Cleaning of DT, Oil Top Up
221Fencing of distribution transformer structure at road side, fabrication and erection (including all materials)
222Ground patrolling of HT lines during breakdown
223Rectification of snapped HT line during breakdown - Weasel ACSR 7/2.59 or AAAC 7/2.50 sq. mm
224Rectification of snapped HT line during breakdown - Rabbit ACSR 7/3.35 or AAAC 7/3.15 sq. mm
225Rectification of snapped HT line during breakdown - Raccoon ACSR 7/4.09 sq. mm
226Rectification of snapped HT line during breakdown - Dog ACSR 6/4.72 & 7/1.57 sq. mm
227Rectification of snapped LT line during breakdown
228Replacement of flashed over HT pin insulator, LAS, strain disc including jumpering, binding and transporting of required materials
229Cleaning of 110 KV breakers including CTs and allied maintenance work in SS
230Cleaning of 110 KV LAS in SS
231Cleaning of 110 KV AB Switch and applying petrolium gelly (including consumables and petrolium gelly) in SS
232Cleaning of 33/22/11 KV breakers and CTs and allied maintenance works in SS
233Cleaning and checking of 110 KV bus insulators in SS
234Cleaning and checking of11/ 22 / 33 KV bus insulators in SS
235Cleaning and checking of 11/22/33 KV AB switches including tightening of bolt & nuts and applying petrolium gelly and rectifying defects (excluding consumables, bolt and nuts and petrolium gelly) in SS
236Replacement of clamps in substation including jumpering in SS
237Tightening of clamps in all 110/33/22/11 KV buses in SS
238Checking of earth pit, tightening and replacing of bolts and nuts in SS
239Cleaning of cable duct in SS
240Cleaning of 110 KV power transformer insulator and assissting for all other maintenance work in SS
241Cleaning and checking of 33/22/11 KV PT & station transformer and assisting of other maintenance work in SS
242Cleaning and checking of capacitor bank and other accessories in SS
243Replacement of droppers and jumpers, taking measurement, cutting and all allied works for single Kundah / Zebra in SS
244Replacement of droppers and jumpers, taking measurement, cutting and all allied works for double Kundah / Zebra in SS
245Releasing, testing and refixing of existing SV / MV lamps fittings in SS
246Releasing, testing and refixing of existing FTL fittings in SS
247Releasing / refixing of capacitor cell in SS
248Painting of steel section in SS structure after cleaning and removing the rust etc. with materials
249Knitting of chair including supply of materials
250Stiching of files including materials
251Binding of books upto A4 size
252Binding of books above A4 size
253Clearing scrub jungle for UG cable works
254Dismantling and clearing away the brick / stone masonry walls of any thickness and built in cement mortar
255Dismantling and clearing away the plain cement concrete
256Dismantling and clearing away the RCC
257Earth work excavation in all kind of soils within an initial lead of 10 m and lift of 2 m in trenches
258Earth work excavation in soft disintegrated rock (not requring blasting) and depositing on bank within an intial lead of 10 m and lift of 2 m in trenches (narrow pits) less than 1 m width
259Removing hard rock by wedging, chiselling and trimming to proper shape where blasting is prohibited
260Cutting open the blacktopped road surface including the cost for providing signal boards, lights, watch and ward to regulate the traffic, taking all precautions to protect the men, materials and the public from any possible accidents etc., using JCB / air compressor (or) drilling machines etc., wherever necessary (at anytime throughout the day) including taking all precautions to prevent any damages to the telecom and water lines
261Dewatering the cable trench / duct using 5 HP diesel pumpset wherever necessary including hire charge for tools & plants, labour, lead and lifts, etc., complete
262Refilling with excavated earth consolidating in layers and the top brought for line with the existing surface including cost of labour, lead, lift, etc., complete
263Removal cut stone slabs / RCC cover slabs
264Laying of PCC (1:3:6) using 20 mm HBG metal over the casing PVC pipes provided at the road crossings, streets, cable ducts, etc., including cost of all materials, lead, lift, labour charges, watch and ward, danger light, signal board, etc., complete
265Supplying of RCC V troughs 11 KV and laying over the UG cable to proper guide and alignment inside the cable trench, painting letters of not less than 75 mm an either side of the troughs as directed by the Engineer incharge of works including the cost for all materials, transporting of troughs from the source to the destination upto 30 kms, stenciling, painting, brushing all leads and lifts, etc., complete
266Laying of 11 KV RCC V troughs and laying over the UG cable to proper guide and alignment inside the cable trench, painting letters of not less than 75 mm an either side of the troughs as directed by the Engineer incharge of works including the cost of all materials, transporting of troughs from the source to the destination upto 30 kms, stenciling, painting, brushing all leads and lifts, etc., complete
267Supplying of RCC V troughs 33 KV and laying over the UG Cable to proper guide and alignment inside the cable trench, painting letters of not less than 75 mm an either side of the troughs as directed by the Engineer incharge of works including the cost for all materials, transporting of troughs from the source to the destination upto 30 kms, stenciling, painting, brushing all leads and lifts, etc., complete
268Laying of 33 KV RCC V troughs and laying over the UG cable to proper guide and alignment inside the cable trench, painting letters of not less than 75 mm an either side of the troughs as directed by the Engineer incharge of works including the cost of all materials, transporting of troughs from the source to the destination upto 30 kms, stenciling, painting, brushing all leads and lifts, etc., complete
269Supplying, laying, jointing and fixing in position cement pipes of 225 mm dia in size in the excavated cable trench as directed by the Engineer incharge at site, including the cost of rope, sealing the ends with cement mortar, labour, lead, lifts, etc., complete
270Uncoiling and laying of 11 KV HT cable in the excavated trench including drawing the cable trough RCC / GL / PVC pipes wherever necessary at road crossing, etc., without any damage including transporting of cables, tools and plants, labour, lead, lift, etc., complete
271Uncoiling and laying of 33 KV HT cable 3x400 sq. mm in the excavated trench including drawing the cable trough RCC / GL / PVC pipes wherever necessary at road crossing, etc., without any damage including transporting of cables, tools and plants, labour, lead, lift, etc., complete
272Uncoiling and laying of 33 KV HT cable 1x630 sq. mm in the excavated trench including drawing the cable trough RCC / GL / PVC pipes wherever necessary at road crossing, etc., without any damage including transporting of cables, tools and plants, labour, lead, lift, etc., complete
273Cutting the cable of required length and sealing the ends with suitable end caps for XLPE cables including cost of all materials, tools and plants, leads and lifts, etc., complete
274Transporting of the remains of the empty cable drums (iron materials) to the stores for devolution including loading and unloading, leads and lifts, etc., complete
275Supply and erection of cable marker in RCC (1:2:4) using 20 mm HBS metal of size 0.3 x 0.6 m and of 100 mm thick, engarving letters \"TANGEDCO UG CABLE\", painting the engraved letters, fixing the cable marker in a bed of PCC (1:3:6) using 20 mm HBS metal of size 0.45 x 0.3 x 0.45 m including cost of all materials, labour, transporting to the destination, all leads and lifts, etc., complete
276Providing watch and ward required at site as directed by the Engineer incharge
277Uprooting of tree cutting charges including labour charges and power machine hire charges
278Providing crusher dust instead of sand with good quality to a depth upto 150 mm (6\") including cost of materials, labour, leads and lifts, etc., complete
279Provision for replacement of damaged water pipe line to the original arrangement during execution of cable work, including cost of all materials, labour, transportation, lead and lift, etc., complete - Upto 4\" dia pipes (LMR)
280Provision for replacement of damaged water pipe line to the original arrangement during execution of cable work, including cost of all materials, labour, transportation, lead and lift, etc., complete - Upto 6\" dia pipes (LMR)
281Supplying and laying of HDPE pipe 110 mm dia 6 mm wall thickness by using of trenless technology horizondal direction drilling method for road crossing minium 55 metres inclusive of incertion of HT cables in HDPE pipes
282Supplying and erection of cast iron 250 mm dia pipes at railway crossing by adopting trenchless method including cost of all materials, labour, transporting, lead, lift, etc., complete
283Supplying and erection of cast iron 250 mm dia pipes at railway crossing by open cutting method including cost of all materials, labour, transporting, lead, lift, etc., complete
284Supplying and erection of GI 150 mm dia pipe for drainage / bridge / canal crossings including cost of all materials, labour, transportation, lead, lift, etc., complete
285Construction of RCC trench with removable RCC slab including cost of all materials, labour, lead, lift, transporting, centering charges, curing with all lead, lifts, etc., complete (in 1.35 mts depth)
286Construction of RCC trench with removable RCC slab including cost of all materials, labour, lead, lift, transporting, centering charges, curing with all lead, lifts, etc., complete (in 1.20 mts depth)
287Erection of 11 KV 3x120 sq. mm and 3x300 sq. mm outdoor / indoor termination kit (LMR)
288Erection of 11 KV 3x120 sq. mm and 3x300 sq. mm straight joint kit (LMR)
289Erection of 33 KV 3x400 sq. mm indoor / outdoor terimination kit (LMR)
290Erection of 33 KV 3x400 sq. mm straight joint kit (LMR)
291Erection of 33 KV 1x630 sq. mm indoor / outdoor terimination kit (LMR)
292Erection of 33 KV 1x630 sq. mm straight joint kit (LMR)
293Supplying and laying of 160 mm dia PVC pipe of 6 KSC of approved quality and of reputed make for road and drainage crossing for the cable laying at road drainage crossing including cost of all materials, labour, lead, lifts, etc., complete
294Uncoiling and laying of LT cable of size 4x120 and 4x240 sq. mm in the excavated trench including drawing the cable trough RCC / GL / PVC pipes wherever necessary at road crossing, etc., without any damage including transporting of cables, tools and plants, labour, lead, lift, etc., complete
295Uncoiling and laying of LT cable of size 4x25 sq. mm and 2x16 sq. mm for service connection including excavation of trench, laying of cable, refilling of trench and termination of cables and transportation
296Construction of RCC pedestal of size 0.75 x 0.25 x 1.05 m (2 Nos) for fixing 6 way pillar box with 15.76 kgs of steel reinforcement in 0.394 cubic metre of ROC (1:2:4) mix concrete using 20 mm HBS metal, plastering (1:5) 12 mm thick around the pedestal, colour washing two coats over one coat of primer using white cement including cost of all materials, labour, transportation of all materials, fixing the pillar box in proper alignment over the pedestal, tools and plants, lead, lift, etc., complete
297Construction of RCC pedestal of size 0.60 x 0.25 x 1.05 m (2 Nos) for fixing 4 way pillar box with 13.88 kgs of steel reinforcement in 0.315 cubic metre of ROC (1:2:4) mix concrete using 20 mm HBS metal, plastering (1:5) 12 mm thick around the pedestal, colour washing two coats over one coat of primer using white cement including cost of all materials, labour, transportation of all materials, fixing the pillar box in proper alignment over the pedestal, tools and plants, lead, lift, etc., complete
298Construction of RCC pedestal of size 0.60 x 0.25 x 1.05 m (2 Nos) for fixing mini pillar box with 13.88 kgs of steel reinforcement in 0.315 cubic metre of ROC (1:2:4) mix concrete using 20 mm HBS metal, plastering (1:5) 12 mm thick around the pedestal, colour washing two coats over one coat of primer using white cement including cost of all materials, labour, transportation of all materials, fixing the pillar box in proper alignment over the pedestal, tools and plants, lead, lift, etc., complete
299Painting two coats of enamal emulsion paint over one coat of metal white primer for 6 way pillar boxes by using spray paint including cost of materials, lead, lift, labour, etc., complete
300Painting two coats of enamal emulsion paint over one coat of metal white primer for mini pillar boxes by using spray paint including cost of materials, lead, lift, labour, etc., complete
301Supplying and pasting of stencil cut stickers with good adhesives with lettres showing \"TANGEDCO\", \"440 V\" and \"Danger\" with skull and bone symbols, etc., including cost all materials, lead, lift, labour, etc., complete (LMR)
302Construction of RCC trench with removable RCC slab including cost of all materials, labour, lead, lift, transporting, centering charges, curing with all lead, lifts, etc., complete (in 0.75 mts depth)
303Dismantling of 6 or 4 way pillar box including associated accessoris, loading on the vehicle, transporting, unloading at stores and stacking
304Dismantling of mini pillar box including associated accessoris, loading on the vehicle, transporting, unloading at stores and stacking
305Supply of 11 KV 3x120 sq. mm indoor termination kit
306Supply of 11 KV 3x120 sq. mm straight joint kit
307Supply of 11 KV 3x120 sq. mm outdoor termination kit
308Supply of 11 KV 3x300 sq. mm indoor termination kit
309Supply of 11 KV 3x300 sq. mm straight joint kit
310Supply of 11 KV 3x300 sq. mm outdoor termination kit
311Supply of 33 KV 3x400 sq. mm indoor termination kit
312Supply of 33 KV 3x400 sq. mm straight joint kit
313Supply of 33 KV 3x400 sq. mm outdoor termination kit
314Supply of 33 KV 1x630 sq. mm indoor termination kit
315Supply of 33 KV 1x630 sq. mm straight joint kit
316Supply of 33 KV 1x630 sq. mm outdoor termination kit

AI Tender Summary

OUR REF NO 46018227
AUTHORITY Boards / Undertakings / PSU
TENDER VALUE Ref. Documents
LAST DATE 14-11-2024
Authority
Authority Name Tamil Nadu Generation And Distribution Corporation Limited
Work Description Ht And Lt Line Extension And Improvement Works In North Annur Sub Division Ht And Lt Line Extension And Improvement Works In North Annur Sub Division Of Avinashi Division
Basic Detail
Tender No WOT-24/2024-25 Dt. 29.10.2024
Bidding Type Tender
Location
City annur
State Tamil Nadu
Key Dates
Publish Date 30 Oct 2024
Submission Date 14 Nov 2024
Open Date 15 Nov 2024
Finance
Tender Value Ref. Documents
Tender Fee Ref. Documents
EMD 15000
Exemption Available
Document List
ccc52eb3-a7d7-4ff0-af66-c012b920690d.html
BOQ_591725.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 30, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 14, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 15, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

ccc52eb3-a7d7-4ff0-af66-c012b920690d.html

xls

BOQ_591725.xls

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail