| 1 | S/L of 3 Core standard aluminium conductor XLPE (Cross linked Polyethylene) insualted PVC bedded, Galvanied flat steel strip armored 185 Sqmm 3 Core 11 KV grade cable confirming to I.S. 7098 ( Part-II with latest amendement)at a depoth of 900 mm below ground level ovdr a cushion of 100 mmthick fine rriver. sand al around and protected with well burnt bricks in sides and on top purt across. The armoring of cable shall be properly connected with earth conductorby clamps etc. |
| 2 | S/F of 185 Sq mm 11 KV Stright/ out door/Indoor Joint Kit complete. |
| 3 | S/L of 3 Core standard aluminium conductor XLPE (Cross linked Polyethylene) insualted Galvanied flat steel strip armored 300 Sqmm 3 Core 33 KV grade cable confirming to I.S. 7098 ( Part-II with latest amendement)at a depoth of 1200 mm below ground level ovdr a cushion of 100 mmthick fine rriver. sand al around and protected with well burnt bricks in sides and on top purt across. |
| 4 | S/F of 300 Sq mm 33 KV Joint Kit straight Through /Outdoor/Indoor complete. Rate PSR |
| 5 | Trenchles Drilling with HDPE upto 11 KV Cable 100 mm dia/ In 33 KV 150 Sqmm as requiredHDD for carring of Cable on Road Crosing complete with Repairing of all internal water connection/Sever Connection if necessary complete |
| 6 | Removal & Relaying of HT/LT Cable with excavation & Back filling complete |
| 7 | Dismantling & Store /Street light Poles /PCC/Rail as per direction of UPPCL with Loading unloading cartage of Pole embedded in brick ballast & CC foundation etc. as required. |
| 8 | S/F Steel Tubular Pole 11 M. long designated 410 SP/55 in 1:3:6 cement concrete foundation including excavation back fillingetc. Complete in allrespect. Rate based on S.I. No. 613/2018 on Weight basis |
| 9 | S/F of MS Channel, V shape, Bracing,Angel, Clamps and other required MS Iron Items etc. |
| 10 | S/E of Stay set at least 3.5 M. away from the Pole complete with galvanised 19 mm diax 1.80. M. long Sary clamps, stay insulator 19 mm x 600 double screw tightener, 7/4.00 mm G.I. stary wire etc. in 1:3:6; cemtn concrete complete . |
| 11 | Painting of the electric pole with 2 coats of aluminium paint over red primncer complete |
| 12 | Earthing of pole by MS earthing rod of 20x2500mm and 6 SWG earthing wire etc complete. |
| 13 | S/F of 100 mm dia GIPipe Clas B Make Jindal Complete with required clamping . |
| 14 | S/F of Dead End Insulated Clamps complete on Poles as direction of E/I. |
| 15 | SITC of TPMO Set and DO Fuse Set 11 Kv with Handle clamps nuts bolts and required Fuse |
| 16 | Supply and burring of Safe Earthing Electrode T-39 Zn-Zinc Coated, Length2000mm, outer pipe 76.3mm x 3.2 inner pipe 42.4mm x 2.6mm, terminal Dia 12mm, coating 80-100 micron filled with crystalline conductive mixture (CCM) having anti corrosive & conductive property with 50 kgs activated soil (BFC) capable of reducing the soil resistivity with good mixture of retaining capacity along with 30 cm square C.I. frame with hinged cover & masonry housing. (From electrode terminal to switch board, cost of 25 x 3 G.I. Strip .Make: As approved in U.P. P.W.D., & C.P.R.I. Certified. (PWD SOr-726 (C)/2018) |
| 17 | Supply & fixing of 20 mtr High mast shaft of approved make with rising system hot dip glavanized inside & out side dip,heaving pole sheet thickness 4 mm. Top dia minium 150 mm, Bottom dia 410 mmbase plate 32 mm thick suitable for wind velocity as per IS 875 part 3 &having no circumferential weld, with accessories for high mast such as head frame suitable for 6 to 12 luminaries & its control gear boxes 1.5 HP power tool moter, 3 point suspension system with steel wire rope 8 mm dia, double drum winch, including making suitable foundation as per manufature drawing/ site reuiment along with foundation bolts nuts, washers, anchor plates etc completee in all respect.(PWD SOr-653/2018) |
| 18 | Supply and fixing offactory wired integral LED flood light luminaires with die cast aluminium housing built with dirver set suitable for200 Watt. Confirming to IP 66 protection complete in all respect.with requried connecting wire(PWD SOr-1455/2018) |
| 19 | Supply and fixing of 40 amp TPN capacity of automatic street light cubicle control panel painted with anti corrosive alkali and acid proof paint consisting of time switch TSO 100 series with contactors, HRC fuses, isolating switch metering instrument & instrument box with CTs etc. in case of TPN, complete in all respect.(PWD SOr-807F(II)/2018) |
| 20 | Supplyandlayingof 50 sqmm 3.5 core aluminiumconductorPVCinsulated armoured served sheathed cables 1100 Volts grade at a depth of 750 mm below ground level over a cushion of 75 mm. thick sand all around and protected with burnt bricks on sides and on top. On surface the cable run shall be fixed on M.S. clamps etc. of suitable size or as directed by the Engineer-Incharge, complete in all respect. The armouring of the cable shall be properly connected with the earth conductor by clamps etc.(PWD SOr-501(L)/2018) |
| 21 | Supplyandlayingof 6 sqmm 4 corecopper conductor DoublePVCinsulatedserved sheathed cables 1100 Volts grade(PWD SOR-501(G)/2018) |
| 22 | S/L of 110 mm HDPE dia pipe PN-4 all complite |
| 23 | S/L of50 mm dia (OD-50 mm nominal) DWC HDPE pipe 6 Kg ISI marked alongwith all accessories like socket, bend, couplers etc. conforming to IS 14930, Part Ii complete with fitting and cutting. Jointing etc, direct in groudn (75 cm below ground level) including excavation and refilling the trench but excluding sand cushioning and protective covering etc. |
| 24 | Deduct in item no. 501 (I) 501 (t) and 506 (a) to (f) when cables is passed through G.I./M.S. or Hume pipe in road crossing or along the wall. The cost of the G.I. pipe, hume pipe is to be extra when and where required. (PWD SOR-507/2018) |