Tender For Construction of a modern bathroom for the entrance of house number-21 Type-5 located in Raj Bhavan Colony, work of replacing old and rusty bathroom fittings of a bathroom of the house, work of laying tiles in the shed built in the courtyard of the house and other miscellaneous works, 1 Earth work in excavation by mechanical means (Hydraulic excavator)/ manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and for all lift, as directed by Engineer-in-charge. all kinds of soil. DAR NO-(2.6.1) 2 Brick work with common burnt clay (non madular) brick of class- 150 in foundation and plinth in::1:4( 1 cement :4 coarse sand ) (dar-6.1.1) 3 Brick work with common burnt clay (non madular) brick of class- 150 in superstructure above plinth level up to floor V level in all shape and sizes in cement mortar 1:4 ::(1 cement :4 coarse sand )( Dar 6.4.1) 4 Providing and fixing PVC pipes (6kg/sqcm) for sewer line including all fitting including trenching refilling & testing of joints complete as per direction of Engineer in charge110 mm dia . 5 Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes , having thermal stability for hot & cold water supply , including all CPVC plain & threaded fittings , i/c fixing the pipe with clamps at 1.00 m spacing . This includes jointing of pipe & fitting with one step CPVC solvent cement and cost of cutting chases and making good the same including testing of pipes complete as per direction of Engineer - in - charge , concealed work . including cutting chases and making good the walls etc (20 mm nominal outer dia pipe )18.8.2 6 Providing and fixing 25 mm diachlorinated polyvinyl chloride (cpvp )pipes , having thermal stability for hot & cold water supply including the supply with clamps at 1.00m spacing . This includes jointing of pipe and fiting with one step salvent cement and testing of joints complete as per direction of Engineer in charge -Internal work - Exposed on wall (dar-18.7.3) 7 centering and suttering including shuttring, propping etc and removal of form work for : Suspeneded floors, roofs, landing , balconies and access platform (dar -5.9.3) 8 Steel reinforcement for R.C.C. work including straightening, cutting, bending, placing in position and binding all complete upto plinth level Thermo-Mechanically Treated bars of grade Fe-500D or more. DAR NO-5.22.6 9 Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level:-1:1.5:4 (1 cement :1.5 coasre sand ( Zone-III) :4 graded stone aggregate 20 mm nominal size (4.1.2) 10 12 MM cement plasterof mix ;1:4 ( 1 cement :4 coarse sand ) )DAR NO-13.4.1 11 Providing and fixing C.P. brass angle valve l&Kfor basin mixer and geyser points of approved quality 15 mm nominal bore. 12 Supply and Fixing C.P. brass bib cock 15mm. dia. Long body L&K 0047 including supply of all materials, labour, T&P etc. required for proper completion of the work. 13 Supply and Fixing C.P. brass bib cock 15mm. dia. Short body L&K 0057 including supply of all materials, labour, T&P etc. required for proper completion of the work. 14 Providing and fixing C.P. brass OVER HEADshower with arm heavy qualityL&K 0668 with 15mm inlet: 150 mm diameter 15 Supply and fixing of white glazed earthen ware Wash Hand Basin with pedestal ( 550x430x195 mm Qubax ) with C.P Waste jali,, pvc waste pipe,including supply of all materials labour T&P etc. required for proper completion of the work. 16 Providing and fixing water closet squatting pan (Indian type W.C. pan ) with 100 mm sand cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to IS : 7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: of size 580x440 mm 17.1.1 17 Providing and layeing in position cement concrete of specified grade excluding the cost of centering and shuttering All work up to plinth level:1:5:10 (1 cement :5 coasre sand ( Zone-III) :10 graded stone aggregate 40 mm nominal size dar-4.1.10 18 Providing and laying vitrufied floor tile in different sizes ( thickness to be specified by the manufacturer)with water absorption less than 0.08% and comferming to IS :15622 , of approved make in all colour and shade , laid on 20mm thick cement mortar 1:4 (1 cement : 4 coarse sand ) jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigment etc complete(ch-13- ref- 11.41.2) ( size of tile 600x600 mm ) 19 Providing and Fixing white designedtiles of size 595x595 mm, and 8 mm thick made of fiber cement board in true horizontal level, suspended on inter locking metal grid of hot dipped galvanised steel sections (galvanising @ 120 grams per sqm including both side) consisting of main T runner suitably spaced at joints to get required length and of size 15x38 mm made from 0.30 mm thick (minimum) sheet, spaced 1200 mm centre to centre, and cross T of size 15x38 mm made out of 0.30 mm (Minimum) sheet, 1200 mm long spaced between mainT at 600 mm centre to centre to form a grid of 1200x600 mm and secondary cross Tof length 600 mm and size 15 x38 mm made of 0.30 mm thick (Minimum) sheet to be inter locked at middle of the 1200x 600 mm panel to from grid of size 600x600 mm, resting on periphery walls /partitions on a Perimeter wall angle pre-coated steel of size(24x19X3000 mm made of 0.27 mm thick (minimum) sheet with the help of rawl plugs at 450 mm centre to centre with 25 mm long dry wall screws @ 230 mm interval and layingof approved texture (Spintone / Cosmos/ hexa) in the grid, including, cutting/ making opening for services like diffusers, grills,light fittings, fixtures, smoke detectors etc., wherever required. Main T runners to be suspended from ceiling using Vertical Hanger fixed to ceiling with Anchor fastenerM6, 2.68 mm G.I. adjustable rods with galvanised steel level clips, spaced at 1200 mm centre to centre along main T, bottom exposed with 24 mm of all T-sections shall be pre-painted with polyster baked paint, for all heights, as per specifications, drawings and as directed by engineer-in-charge. 20 Providing and laying Ceramic glazed floor tiles of size 300x300 mm (thickness to be specified by the manufacturer), of 1st quality conforming to IS : 15622, of approved make, in all colours, shades, except White, Ivory, Grey, Fume Red Brown, laid on 20 mm thick bed of cement mortar 1:4 (1 Cement : 4 Coarse sand), jointing with grey cement slurry @ 3.3 kg/ sq.m including pointing the joints with white cement and matching pigments etc., complete.(dar-11.38) ( size of tile 300x300mm ) 21 Providing and fixing 1st quality ceramic, glazed wall tiles conforming to IS 15622 (thickness to be specified by the manufacturer) of approved make in all colours, shades except burgundy, bottle green black of any size as approved by Engineer-in-charge, in skirting, risers of steps and dados, over 12 mm thck bed of cmeent mortar 1:3 ( 1 cement 3 coarse sand) and jointing with grey cmeent slurry @ 3.3 kg per sqm, including pointign in white cement mixed with pigment of matching shade complete.DAR NO-8.31 450x300 22 Steel work welded in built up sections/ framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer using structural steel etc. as required::In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. (10.25.2) 23 Providing and fixing factory made uPVC glazed/wire mesh windows/doors comprising of lead free uPVC multi-chambered frame, sash and mullion/coupler (where ever required) extruded profiles having minimum wall thickness of 1.70 mm for Series R1 and R2 profiles and 2.10 mm for Series R3 and R4 profiles conforming to EN: 12608 in any shape, colour and design duly reinforced with galvanized mild steel section made of required shape & size as per CPWD Specification, uPVC extruded glazing beads, interlocks and Inline sash adaptor (where ever required) of appropriate dimension, EPDM gasket, hardware, SS 304 grade fasteners of minimum 8 mm dia with countersunk head, comprising of matching polyamide PA6 grade sleeve for fixing frame to finished wall as per IS 1367 : Part 1 to 14, plastic packers, plastic caps and necessary stainless steel screws etc. Profile of frame, sash & mullion (if required) shall be mitred cut and fusion welded/ mechanically jointed duly sealed at all corners, including drilling of holes for fixing hardware and drainage of water etc. After fixing frame the gap between frame and adjacent finished wall shall be filled with weather proof silicon sealant over backer rod of approved size and quality, all complete as per approved drawing conforming to CPWD specification & direction of Engineer-in-Charge. Section of steel reinforcement and cross sections of uPVC profiles to be as per design approved by Engineer-in-Charge. Wire mesh / Glazing of plain/ toughened/ laminated/ double glass unit with / without high performance coatings as per design requirements and conforming to IS: 3548 & IS: 16231 shall be paid separately. Note:- Structural design proof checked from a Government Engineering Institute, to be provided by the manufacturer for : (i) Sites with basic wind speed > 45 m/sec as per IS 875 – Part 3 (ii) Sites with structure height more than 20m for all wind speeds Two track two panels sliding window with Aluminium channel for roller track, wool pile, nylon rollers with SS 304 body. DSR No-9.147.A1 24 Cement concrete flooring 1:2:4 (1 cement :2 coase sand :4 graded stone aggregate ) finished with a floating coat of neat cement , including cement ,slurry ,but excluding the cost of nosing of steps etc complete,40 mm thick with 20 mm nominal in sizestone aggregate (40 mm thick with 20 mm nominal in sizestone aggregate ) DAR NO-11.3.1 25 Providing and applying white cement based putty of average thickness 1 mm, of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete.(D.S.R Item-13.80) 26 Finishing walls with Acrylic premiumSmooth exterior paint with Silicon additives of required shade: New work ( Two or more coats applied @ 1.43ltr/ 10 sqm over and including priming coat of exterior primer applied @ 2.20 kg/ 10 sqm) (apex Ultima, weather coat All guard) asian, berger. ( D.S.R Item 13.47.1 )