Tender For Providing Electrification Of New Cattle Shed For Vechur Farm, Kvasu, Mannuthy
Tender Value
2.30 Lakhs
Estimated cost
Bid Submission
02 Nov 2024
0 days left
EMD
5800
Bank guarantee accepted
Document Fee
560
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
mannuthy → Kerala
EMD Exemption
Not Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Providing Electrification Of New Cattle Shed For Vechur Farm, Kvasu, Mannuthy
BOQ
| Sl. No. | Item Description |
| 1 | Power supply part |
| 2 | 90.1.1.1 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement,tying & fixing the conduit firmly with the re-inforcement etc. as required.20 mm |
| 3 | 90.1.1.2 : Supply and laying medium gauge PVC conduit of the following sizes conforming to IS 9537/1983 Part III in roof slab, jointing the pipes with PVC solvent cement,tying & fixing the conduit firmly with the re-inforcement etc. as required.25 mm |
| 4 | 1.21.1 : Supplying and fixing of following sizes of medium class PVC conduit along with accessories in surface/ recess including cutting the wall and making good the same in case of recessed conduit as required.20 mm |
| 5 | Wiring |
| 6 | 1.10.3 : Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVCinsulated copper conductor single core cable in surface / recessed medium class PVC conduit,with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm. FRLSPVC insulated copper conductor single core cable etc as required.Group C |
| 7 | 1.24.3 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.15/16 amp switch |
| 8 | 1.24.5 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.6 pin 15/16 amp socket outlet |
| 9 | 1.31 : Supplying and fixing suitable size GI box with modular plate and cover in front on surface or inrecess, including providing and fixing 3 pin 5/6 amps modular socket outlet and 5/6 ampsmodular switch, connection etc. as required. (For light plugs to be used in non residentialbuildings). |
| 10 | od135145/2024_2025 : Supply and fixing of 20W LED Tube with fitting. Luker/Philips mushroom 20W<br>all complete. |
| 11 | od135146/2024_2025 : S &F LED Bulb classic 12W on existing batten holder- Luker/Philips/Bajaj/Syska |
| 12 | od135147/2024_2025 : Providing, Installation, testing and commissioning of street light 40/45 W LED<br>(Philips, Bajaj, Luker or Equivalent) |
| 13 | od135148/2024_2025 : Supplying and fixing of following ways surface/recess mounting vertical type 230 V single phase, Energy meter box of size 45*45*20 cm or nearest making material Polycarbonate (sintex Box) or metal (ABB,havells,Indo asian), vision panel, dust protected box including common neutral link, 63 A porcelain fuse set (1 No) etc complete. Provision for fixing KSEB energy meter is included |
| 14 | 1.17.3 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 X 1.5 sq.mm |
| 15 | 1.17.12 : Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface / recessed steel/ PVC conduit as required.3 x 2.5 sq. mm |
| 16 | 2.14.2 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 17 | 2.3.4 : Supplying and fixing following way, single pole and neutral, sheet steel, MCB distribution board, 240 V, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCBIRCCB/Isolator16 way, Double door |
| 18 | 2.12.1 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.40 amps |
| 19 | 2.14.1 : Supplying and fixing following rating, double pole, (single phase and neutral), 240 V, residual current circuit breaker (RCCB), having a sensitivity current 30 mA in the existing MCB DB complete with connections, testing and commissioning etc. as required.25 amps |
| 20 | od135150/2024_2025 : Supply, erection ,testing and commissioning ofwall fan of 450mm (sweep size), Dia 18 inch air circulatory wall mounting fan ( make Almonard/Bajaj/Crompton or equivalent)<br> |
| 21 | 1.33 : Supplying and fixing 3 pin, 5 amp ceiling rose on the existing junction box/ wooden blockincluding connection etc as required. |
| 22 | 1.58 : Supplying and fixing PVC batten/ angle holder including connection etc. as required. |
| 23 | 1.24.4 : Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate etc. as required.3 pin 5/6 amp socket outlet |
| 24 | 1.23.5 : Supplying and fixing following piano type switch / socket on the existing switch box/ cover including connections etc. as required.6 pin 15/16 amp socket outlet |
| 25 | 90.11.1.11 : Supply and installation ofsheet steel, phosphatised and painted, dust and vermin proof enclosure of MCB DB including copper /brass bus bar, neutral link, earth bus and DIN rail suitable for fixing MCB/isolator etc. fixed on wall using suitable anchor bolts or fixed in recess including cutting hole on the wall , making good the damages, colour washing etc. as required6 way (8+18) - three phase double cover (IP 42/43) |
| 26 | 2.10.1 : Supplying and fixing 5 amps to 32 amps rating, 240/415 volts, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required.Single pole |
| 27 | 2.12.2 : Supplying and fixing following rating, double pole, 240 volts, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required.63 amps |
| 28 | Earthing |
| 29 | 5.2 : Earthing with G.I. earth pipe 4.5 metre long, 40 mm dia including accessories, and providingmasonry enclosure with cover plate having locking arrangement and watering pipe etc. withcharcoal/ coke and salt as required |
| 30 | 90.16.1.3 : Supply and drawing bare earthing conductors of the following sizes along with wiring/ cables and giving connection as required3.15 mm copper conductor ( 10 SWG) |
| 31 | Civil work |
| 32 | 50.10.2 : Steel work for purlin/single section with G I pipes including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete |
AI Tender Summary
Tender Timeline
Oct 26, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedNov 02, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedNov 04, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender