| 1 | Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for threephase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCBAC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 160 amp of Make:Schneider/L&T/ GE/Siemens – 14 Nos (ii) MCCBAC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 2 Nos (iii) Three phase digital Timer switch with suitable cap of contactor controlled by existing 63 amp MCCB for street light, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge. |
| 2 | Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for threephase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCBAC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 160 amp of Make:Schneider/L&T/ GE/Siemens – 5 Nos (ii) MCCBAC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 6 Nos (iii) Three phase digital Timer switch with suitable cap of contactor controlled by existing 63 amp MCCB for street light, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge. |
| 3 | Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for threephase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCBAC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 160 amp of Make:Schneider/L&T/ GE/Siemens – 3 Nos (ii) MCCBAC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 13 Nos (iii) Three phase digital Timer switch with suitable cap of contactor controlled by existing 63 amp MCCB for street light, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge. |
| 4 | Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for threephase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCBAC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 100 amp of Make:Schneider/L&T/ GE/Siemens – 4 Nos (ii) MCCBAC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 18 Nos (iii) Three phaseTimer switch with suitable cap of contactor controlled by existing 63 amp MCCB, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge. |
| 5 | Disconnecting, dismantling of existing LT distribution panel and supply, fabricate, install, testing and commissioning of LT feeder panel board of suitable size (Depth of panel not less than 500MM), out door type double door, dust and vermin proof made out of 3.15 mm thick MS sheet mounting on MS angle iron50x50x6 MM size , height of legs not less than 750 mm height, suitable foundation of 150 mm thick PCC (1:3:6) type C 2 with 100 mm offsets and panel board with front and back opening and locking arrangement compete two coats of finishing powder coated paint of approved shade over one coat of red oxide primer including oriental bus bar of aluminium strip 800 amps for threephase 4 wire including the following accessories and fitted in : -(a) Incoming: (i) MCCB high breaking capacity 4 pole 415 volt 36 KA breaking cap adjustable thermal release range 400 amp of Make:HPL/C&S/Schneider/L&T/ Indoasian/GE/Havells – 01 No (ii) Digital type Volt meter & amps meter with suitable capacity of CTs,LED indicator lamp and other connecting accessories (b) Outgoing: (i) MCCBAC high breaking capacity 3 pole 415 volt 25 KA breaking cap adjustable thermal release range 100 amp of Make:Schneider/L&T/ GE/Siemens – 1 No (ii) MCCBAC high breaking capacity 3 pole 415 volt 16 KA breaking cap adjustable thermal release range 63 amp of Make: Schneider/L&T/ GE/Siemens – 10 Nos (iii) Three phase digital Timer switch with suitable cap of contactor controlled by existing 63 amp MCCB for street light, Make: Havells/L&T/ Indo asian – 1 No (iv) MCB SPN 40 Amps 4 Nos all as directed by the Engr In Charge. |
| 6 | M&L for Earthing complete with galvanised steel earth plate electrode 60cm x 60cm and 6 mm thick buried directly in ground (earth pit not less than 2.25 metres deep below normal ground level) with top edge of plate not less than 1.5 meters below normal ground level, connecting to the Galvanised iron earth strip 32mmx6mm size, by means of bolts, nuts, check buts and washers of galvanised iron and 32mmx6mm earth lead protected by provision of GI medium grade pipe 40mm bore including provision 40mm thick cover of RCC (1:2:4) reinforced with XPM (weight not less than 4 Kg/Sqm) and frame of angle iron 40mmx40mmx6mm with6mm dia MS bar handle made to shape, GI light grade 20mm bore pipe for watering of suitable lengthplaced on top edge of earth plate, common salt and charcoal filling, 15 CM alternate layer of charcoal and salt around all sides of earth platewith fixing arrangements, funnel, wire mesh and earth work in any type of soil, returning filling in and removal of surplus soil to a distance not exceeding 50 metre complete all as per plate No 03 of SSR-2009 Part-I and connecting to earth test point all as specified or indicated including testing on completion. |
| 7 | Excavation of existing cable of size 25 Sq mm to 240 Sq mm removingfrom its loop of length 3m to 5m, cleaning, cutting of old termination and reconnecting the same alongwith suitable new aluminium lugs and refilling of cable trench with existing sand and bricks complete all as directed.Note: The rate quoted shall include for necessary earth work |