Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 09-12-2024 | Date Extension for Package VIII | Date | 09-01-2025 |
| 2 | 05-12-2024 | Notice of Technical Bid Opening of Package VIII | Other | 09-12-2024 |
| 3 | 07-11-2024 | Notice for Pre Bid Meeting | Other | 09-12-2024 |
| Sl. No. | Item Description |
| 1 | Construction of step concrete wall near intake at Left bank collapsed on 20th July 2019 near intake of Myntdu Leshka Dam. |
| 2 | Earthwork in excavation for structures. BY MANUAL MEANS in Ordinary Soil. |
| 3 | Supplying fitting and placing HYSD bar reinforcement (Fe 415) in Substructure complete as per drawing and Technical direction of the Engineer-in charge. |
| 4 | Plain/reinforced cement concrete in sub-structure complete as per drawings and Technical Specificationand direction of Enginner-in-charge inP.C.C. grade M20 (1 : 1.5 : 3) Nominal mix Upto 5 m Height. |
| 5 | Providing and laying filter media with granular crushed aggregates as per specification to a thickness of not less than 600 mm with smaller size towards the soil and bigger size towards the wall and providing over the entire surface behind abutment, wing wall, return wall to the full height, compacted to firm condition complete as per drawing and direction of the Engineer-incharge. |
| 6 | Construction of step stone masonry wall above staff quarter near view point at Right bank. |
| 7 | Earthwork in excavation by Mechanical means up to a depth of 2 in below the existing ground level tor foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils. In All kinds of soil (ordinary soil/ hard soil/ dense soil). |
| 8 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 9 | Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level in:Cement mortar 1 :6 (1 cement: 6 coarse sand). |
| 10 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel). |
| 11 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 m.With available excavated earth. |
| 12 | Construction of step stone masonry wall below staff quarter near DG set at Right bank of Myntdu Leshka Dam. |
| 13 | Earthwork in excavation by Mechanical means up to a depth of 2 in below the existing ground level tor foundation, trenches Of foundations, footings Of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification Of soils.In All kinds of soil (ordinary soil/ hard soil/ dense soil). |
| 14 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 15 | Plandom rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level in: Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 16 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge:Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (using steel). |
| 17 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 m:With available excavated earth |
| 18 | Pointing on stone work with cement mortar 1 :3 (1 cement: 3 fine sand): Flushed/ Pluled pointing. |
| 19 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) : Thermo-Mechanically Treated bars (TMT bar). |
| 20 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: Mix M20 or 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 21 | Providing and fixing hand rail of approved size bywelding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: G.I. pipes. |
| 22 | 12 mm cement plaster of mix: 1 :4 (1 cement: 4 fine sand). |
| 23 | Construction of step protection wall below DG set at right bank of Myntdu Leshka Dam. |
| 24 | Earthwork in excavation by Mechanical means up to a depth of 2 m below the existing ground level for foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.In All kinds of soil (ordinary soil/ hard soil/dense soil). |
| 25 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 26 | Random rubble masonry with hard stone in foundation and plinth including leveling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level in: Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 27 | Centering and shuttering lncludlng strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel). |
| 28 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m:With available excavated earth. |
| 29 | Reconstruction of grill railing at top of retaining wall constructed at the area of masonry wall collapsed on 20th July 2019 near intake of Myntdu Leshka H.E Project. |
| 30 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required):Thermo-Mechanically Treated bars (TMT). |
| 31 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 32 | Steelwork welded in built-up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat Of approved steel primer using structural steel etc. as required: In gratings, frames, guard bar, ladder, railings, brackets, gates and similar works. |
| 33 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge:In Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 34 | Construction of protection/step stone masonry wall in the reservoir rim at Left bank of Myntdu Leshka Dam,upstream of the Dam (Part-I) |
| 35 | Earthwork in excavation by Mechanical means up to a depth of 2 m below the existing ground level tor foundation, trenches Of foundations, footings Of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification Of soils. In All kinds of soil (ordinary soil/ hard soil/dense soil). |
| 36 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size) |
| 37 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level in:Cement mortar 1 :6 (1 cement: 6 coarse sand). |
| 38 | Centering and shuttering including strutting, propping etc. and removal of form for allheights complete and as directed by Engineer in charge. In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (using steel). |
| 39 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) : Thermo-Mechanically Treated bars (TMT). |
| 40 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 41 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.With available excavated earth. |
| 42 | Construction of protection/step stone masonry wall in the reservoir rim at Left bank of Myntdu Leshka Dam,upstream of the Dam (Part-II) |
| 43 | Earthwork in excavation by Mechanical means up to a depth of 2 m below the existing ground level tor foundation, trenches Of foundations, footings Of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification Of soils.In All kinds of soil (ordinary soil hard soil/dense soil). |
| 44 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 45 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level in: Cement mortar 1 :6 (1 cement: 6 coarse sand). |
| 46 | Centering and shuttering including strutting, propping etc. and removal of form for allheights complete and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel). |
| 47 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars (TMT). |
| 48 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: In mix M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 49 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc. in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m.With available excavated earth. |
| 50 | Construction of protection/step stone masonry wall in the reservoir rim at Left bank of Myntdu Leshka Dam, upstream of the Dam (Part-III) |
| 51 | Earthwork in excavation by Mechanical means up to a depth of 2 m in below the existing ground level tor foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils.All kinds of soil (ordinary soil/ hard soil/dense soil) |
| 52 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately):In mix 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 53 | Plandom rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level in: Cement mortar 1 :6 (1 cement: 6 coarse sand). |
| 54 | Centering and shuttering including strutting, propping etc. and removal of form for allheights complcte and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (using steel). |
| 55 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) : Thermo-Mechanically Treated bars (TMT). |
| 56 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In mix M20 or 1:1½:3 (1 cement : 1½ coarse sand : 3 graded stone aggregate 20 mm nominal size). |
| 57 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m:With available excavated earth. |
| 58 | Repairing of second stage concreting in Block-out in chute spill way using high strength M90 concrete(local areas)over the existing eroded surface after application of bonding agent at Myntdu Leshka Dam. |
| 59 | Providing and laying of high strength concrete M90 grade concrete as per specification & direction of E/I proper compaction, curing with all lead and lift,ensuring adequate mix desing and quality Control for testing as IS Standard & Technical specification, complete finish items including supply of all materials, Labour, T&P etc. required for proper completion of work. |
| 60 | Providing topping with fresh Concrete M60 grade concrete at Myntdu Leshka Dam top. |
| 61 | Providing and laying of high strength concrete of M60 grade concrete as per specificationproper compaction, curing with all lead and lift, ensuring adequate mix design and Quality Control for testing as IS Standard & Technical specification, complete finish items including supply of all materials, Labour, T&P etc. required for proper completion of work. |
| 62 | Repairing Of Gallery Drain Including Hand Railing and Making V-Notch Inside The Gallery. |
| 63 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth of 100 mm up to 200 mm in PICC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-in-charge:Up to and including 12 mm dia. |
| 64 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars (TMT) |
| 65 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge. Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 66 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer. In G.I. pipes. |
| 67 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: In mix M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 68 | 12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand). |
| 69 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surfaces:Water thinnable cement primer |
| 70 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation Of surface, etc. complete: On concrete work. |
| 71 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 72 | Structural steel work in single section, fixed with or without per kg 117.00 connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. Chequer Plate 6mm x 240 x 1200. |
| 73 | Providing and laying cement concrete in retaining walls ctc and all works above plinth level such as pilasters, columns, pillars, posts, struts, buttresses, parapets, coping, plaln window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost of centering, shuttering and finishing.1 :1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 74 | Providing and {ixing in position collapsible steel shutters with vertical channels 20xl0x2 mm and braced with flat iron diagonals 20x5 mm size, with top and bottom rail of T-iron 40x40x6 mm, with 40 mm dia. steel pulleys, complete with bolts, nuts, locking arrangement, stoppers, handles, including applying a priming coat of approved steel primer. |
| 75 | Repairing HPSV/MH Fitting Junction Boxes and associated auxiliaries to replaced the damaged top lantern poles and fixture: |
| 76 | Supplying fitting and fixing of LED Lightings complete: With LED Street Light- Rodeo Series 25-150W. |
| 77 | Providing and laying connection testing & commissioning of the following sizes of 1100V grade aluminium conductor armoured underground cable & overall PVC sheated cables as per ISI code in trenches including the cost of digging the trenches sand cushioning with laying etc and refilling the samein layers or by supporting them in walls and all other accessories as required. |
| 78 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required:With 200 mm x 150 mm x 75 mm deep. |
| 79 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: Single pole. |
| 80 | Erection of metallic pole of following length in cement concrete 1:3:6 (1 cement : 3 coarse sand : 6 graded stone aggregate 40mm nominal size) foundation including excavation and refilling etc. as required: Above 4.5 metre and upto 6.5 metre. |
| 81 | Repairing of intrenal electrification with water proof wire, socket, switch, MCB, etc. inside Gallery. |
| 82 | Wiring for group controlled (looped) light point/fan point/exhaust fan point/call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVC conduit,and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required: (long point wiring). |
| 83 | Wiring for light/ power plug with 2X4 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed steel conduit alongwith 1 No. 4 sq. mm FRLS PVC insulated copper conductor single core cable for loop earthing as required. |
| 84 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed steel conduit, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required (long Point Wiring). |
| 85 | Wiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed medium class PVC conduit as required: With 4 X 10 sq. mm + 2 X 6sq. mm earth wire. |
| 86 | Providing and fixing following capacity TP&N disconnector fuse switch unit inside the existing panel board with ISI marked HRC fuses including drilling holes in cubicle panel, making connections, etc. as required: With 125 ATP&N. |
| 87 | Supplying and fixing Cable End Box (Loose Wire Box) suitable for following triple pole and neutral, sheet steel, MCB distribution board, 415 Volts, on surface/ recess, complete withtesting and commissioning etc.as required: For 4 way, Double door TPN MCBDB . |
| 88 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required: With Single pole and nuetral. |
| 89 | Supplying and fixing PVC batten/ angle holder including connections etc. as required. |
| 90 | Repairing of illumination system in the Walkway Downstream of the Dam. |
| 91 | Supplying fitting and fixing of LED Lightings complete:LED Street Light- Rodeo Series: 25-150W. |
| 92 | Supplying fitting and fixing of LED Lightings complete:LED Beam/Flood Lights- Rayon Series: 90-200W. |
| 93 | Supplying and fixing metal box of following sizes (nominal size) on surface or in recess with suitable size of phenolic laminated sheet cover in front including painting etc. as required: With 200 mm x 150 mm x 75 mm deep. |
| 94 | Wiring for circuit/ submain wiring along with earth wire with the following sizes of FRLS PVC insulated copper conductor, single core cable in surface/ recessed steel conduit as required: With 2 x 4 sq. mm + 1 x 4 sq. mm earth wire. |
| 95 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required: With 4 x 6 sq. mm. |
| 96 | Supplying and fixing following rating, four pole, 415 V, isolator in the existing MCB DB complete with connections, testing and commissioning etc. as required: With 63 amp. |
| 97 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole. |
| 98 | Providing safety railing and drilling of drain holes at horizontal girder including welding works in the bottom most of radial gate\"s arm. |
| 99 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: G.I. pipes. |
| 100 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, includingscaffolding:Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 101 | Providing Drain holes In Sluice Radial Gates Gate 50mm by Gas Cutting in every Seal Assembly. |
| 102 | MS Plates/Steel section (Gr.A) for E.P. Filling back the Cutting area in Sluice Radial Gate Arms.MS Plate 35mm. |
| 103 | Providing Approach Stairway/Walkway to reach Bucket Lip (Right Bank). |
| 104 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth Of 100 mm up to 200 mm in PICC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-in-charge:Up to and including 12 mm dia. |
| 105 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars (TMT). |
| 106 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
| 107 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge:Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 108 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: Stairs/ spiral staircase, (excluding landings) (using timber). |
| 109 | Providing and fixing hand rail of approved size bywelding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: M.S. tube. |
| 110 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: In mix M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 111 | 12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand). |
| 112 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surfaces:Water thinnable cement primer |
| 113 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete.On concrete work. |
| 114 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 115 | Providing Approach Stairway/Walkway to reach Bucket Lip (Left Bank) |
| 116 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septictank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils. In All kinds of soil (ordinary soil/ hard soil/ dense soil). |
| 117 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level : in Cement mortar 1 :6 (1 cement: 6 coarse sand). |
| 118 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20mm nominal size). |
| 119 | Drilling suitable holes in reinforced or plain cement concrete with power driven drill machine to a minimum depth Of 100 mm up to 200 mm in PICC beams, lintels, columns and slabs to introduce steel bars for sunshades/ balconies including fixing the steel bars in position using epoxy resin anchor grout of approved make but excluding the cost of reinforcement, all complete as per direction of Engineer-in-charge: Up to and including 12 mm dia. |
| 120 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars (TMT) |
| 121 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge.Suspended floors, roofs, landings, balconies and access platform with water proof ply 12 mm thick. |
| 122 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by the Engineer in charge.Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
| 123 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge.Square, rectangle, polygonal in plan or any shape liike Tee/L etc., having plane vertical face. |
| 124 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge..Stairs/ spiral staircase, (excluding landings) (using timber). |
| 125 | Providing and fixing hand rail of approved size bywelding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: M.S. tube . |
| 126 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 127 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: In M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 128 | 20 mm cement plaster ofMix 1 : 4 (1 cement: 4 fine sand). |
| 129 | Applying one coat of water thinnable cement primer of approved brand and manufacture on surfaces:Water thinnable cement primer |
| 130 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation Of surface, etc. complete: On concrete work. |
| 131 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 132 | Construction of roof covering of Gantry crane including walling at Intake gate of Myntdu Leshka Stage-I. |
| 133 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 134 | Providing corrugated G.S. or galvanised iron sheet roofing including vertical / curved surface fixed with polymer coated J or L hooks, bolts and nuts 8mm diameter with bitumen and G.I. limpet washers or with G.I. limpet washers filled with white lead, including a coat of approved steel primer and two coats of approved paint on overlapping of sheets complete (up to any pitch in Horizontal/ vertical or curved surfaces), excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever require 1.00 mm thick with zinc coating not less than 275 gm/m². |
| 135 | Providing ridges or hips of width 60 cm overall width plain G.S. sheet fixed with polymer coated J or L hooks, bolts and nuts 8 mm dia G.I. limpet and bitumen washers complete 0.80 mm thick with zinc coating not less than 275 gm/m². |
| 136 | Painting on G.S Sheet with synthetic enamel paint of approved brand and manufacture of required colour to give an even shade: In New work (Two or more coats) including a coat of approved steel primer but excluding a coat of mordant solution. |
| 137 | Providing high strength M90 grade concrete in the chute spillway and spillway crest for repair of Myntdu Leshka Dam. |
| 138 | Providing and laying of high strength concrete M90 grade concrete as per specification & direction of E/I proper compaction, curing with all lead and lift, ensuring adequate mix design and quality Control for testing as IS Standard & Technical specification, complete finish items including supply of all materials, Labour, T&P etc. required for proper completion of work. |
| 139 | Making platform and steps required to facilitate the people to reach the spillway crest level. |
| 140 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete G.I.Pipes. |
| 141 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer: M.S. tube. |
| 142 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation of surface, etc. complete: On steel work |
| 143 | Construction of Drinking Water Source for Myntdu Leshka Dam at Myntdu Leshka Dam Site (Right Bank). |
| 144 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m: In all kind of soil. |
| 145 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m: In all kind of soil. |
| 146 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns,pillars, posts, struts, buttresses, parapets, coping, plain window sills, fillets, sunken flcor etc., up to first floor level, excluding the cost of centering, shuttering and finishing in mix 1 :2:4 (1 Cemem: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size). |
| 147 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns, pillars, posts, ruts,buttresses, parapets, coping, plaln window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost of centering, shuttering and finishing in Mix M20 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 148 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Mild steel and Medium Tensile steel bars (TMT). |
| 149 | Centering and shuttering including strutting, proppingetc. and removal of form for all heights complete and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc. (using steel). |
| 150 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level:In M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 151 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: In mix proportion 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 152 | Cement plaster in mix 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster |
| 153 | Providing and fixing G.I. pipes complcte with G.I. fittings including trenching and refilling etc. External work: 40 mm diameter nominal bore. |
| 154 | Providing and fixing G.I. pipes complcte with G.I. fittings including trenching and refilling etc. External work: 52 mm diameter nominal bore. |
| 155 | Providing and fixing G.I. pipes complcte with G.I. fittings including trenching and refilling etc. External work: 80 mm diameter nominal bore. |
| 156 | Construction of Drinking Water Source for Myntdu Leshka Dam at Myntdu Leshka Dam Site (Left Bank). |
| 157 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m In All kind of soil. |
| 158 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In All kind of soil. |
| 159 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measuredand paid separately).In mix 1:2:4 (1 Cemem: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 160 | Supplying, fitting and fixing in position reinforcement bars upto lst floor level, conforming to relevant I.S. Code for Ft.C.C.work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details,supplying and binding with 20 G annealed black wire andplacing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Mild steel and Medium Tensile steel bars. |
| 161 | Centering and shuttering including strutting, proppingetc. and removal of form for all heights complete and as directed by Engineer in charge: Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
| 162 | Centering and shutterlng including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge. In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel). |
| 163 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : In M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 164 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : In mix M20 or 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 165 | Cement plaster in mix 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement 20 mm cement plaster. |
| 166 | Providing and fixing G.I. pipes complcte with G.I. fittings including trenching and refilling etc. In External work.50 mm diameter nominal bore |
| 167 | Providing and fixing G.I. pipes complcte with G.I. fittings including trenching and refilling etc. In External work.80 mm diameter nominal bore. |
| 168 | Construction of Drinking Water Storage Tank and Pipe Line From Storage Tank to Dam Control Room (Right bank ). |
| 169 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50m and lift up to 1.5m. In All kinds of soil. |
| 170 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m:In All kinds of soil. |
| 171 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns,pillars, posts, struts, buttresses, parapets, coping, plain window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost of centering, shuttering and finishing: In mix 1:2:4 (1 Cemem: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size). |
| 172 | Supplying, fitting and fixing in position reinforcement bars upto lst floor level, conforming to relevant I.S. Code for Ft.C.C.work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lapping, hooks, chairs, anchorage etc., and no measurement for the same is required)Mild steel and Medium Tensile steel bars (TMT). |
| 173 | Centering and shuttering including strutting, proppingetc. and removal of form for all heights complcte and as directed by Engineer in charge. In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel). |
| 174 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : In M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stoneaggregate 20 mm nominal size). |
| 175 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : In Mix M20 or 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 176 | Cement plaster in mix 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement. 20 mm cement plaster. |
| 177 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 50 mm dia nominal bore. |
| 178 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc: 32 mm dia nominal bore. |
| 179 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :25 to 40 mm nominal bore |
| 180 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete :50 to 80 mm nominal bore |
| 181 | Construction of Drinking Water Storage Tank and Pipe Line From Storage Tank to Dam Control Room (Left bank). |
| 182 | Surface dressing of the ground including removing vegetation and inequalities not exceeding 15 cm deep and disposal of rubbish, lead up to 50 m and lift up to 1.5 m. In All kinds of soil. |
| 183 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In All kinds of soil. |
| 184 | Providing and laying cement concrete in rctaining walls ctc and all works above plinth level such as pilasters, columns,pillars, posts, struts, buttresses, parapets, coping, plaln window sills, fillets, sunken flcor etc,, up to first floor level, excluding the cost Of centering, shuttering and finishingIn mix M20 or1:2:4 (1 Cemem: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size). |
| 185 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C.work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Mild steel and Medium Tensile steel bars. |
| 186 | Centering and shuttering including strutting, proppingetc. and removal of form for all heights complete and as directed by Engineer in charge:In Walls (any thickness) including attached pilasters, buttresses,plinth and string courses etc (using steel). |
| 187 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement - All work up to plinth level : In M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 188 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement : In Mix M20 or 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 189 | Cement plaster in mix 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement:20 mm cement plaster. |
| 190 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. for External work.50 mm diameter nominal bore. |
| 191 | Providing and fixing gun metal gate valve with C.I, wheel of approved quality (screwed end): 50 mm nominal bore. |
| 192 | Dismantling of Existing Stone Masonry Guard Wall and Providing New Pipe Railing at Right Bank of Myntdu Leshka Dam. |
| 193 | Demolishing R.C.C. work manually/ by mechanical means including stacking of steel bars and disposal of unserviceable material within 50 metres lead as per direction of Engineer - in- charge. |
| 194 | Demolishing stone rubble masonry manually/ by mechanical means including stacking of serviceable material and disposal of unserviceable material within 50 metres lead as per direction of Engineer-in-charge : |
| 195 | Providing and laying cement concrete in retaining walls etc., and all works above plinth level such as pilasters, columns, pillars, posts, struts, buttresses, parapets, coping, plain window sills, fillets, sunken flcor etc., up to first floor level, excluding the cost of centering, shuttering and finishingIn Mix M15 or 1:2:4 (1 Cemem: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size). |
| 196 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs,spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required):Thermo-Mechanically Treated bars (TMT). |
| 197 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports,chairs,spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required)Mild steel and Medium Tensile steel bars. |
| 198 | Centering and shuttering including strutting, proppingetc. and removal of form for all heights complete and asFoundations, footings, bases of columns, etc. for mass Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 199 | Centering and shuttering lncludlng strutting, proppingetc: Columns, Pillars, Piers, Abutments, Posts and struts (usingsteel). |
| 200 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: In mix M20 or 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size) |
| 201 | Providing and fixing hand rail of approved size by welding etc. to steel ladder railing, balcony railing, staircase railing and similar works, including applying priming coat of approved steel primer G.I. pipes |
| 202 | 12 mm cement plaster of mix : 1 cement: 4 fine sand. |
| 203 | Applying one coat of water thinnable cement primer of approved brand and manufacture on wall surface: Water thinnable cement primer |
| 204 | Finishing walls with textured exterior paint of required shade : New work (Two or more coats applied @ 3.84 ltr/10 sqm). |
| 205 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. Complete: On steel work. |
| 206 | Repairing of existing side drain and masonry wall at Right bank of Myntdu Leshka Dam. |
| 207 | Earth work in excavation by mechanical means (Hydraulic excavator)/manual means over areas (exceeding 30 cm in depth, 1.5 m in width as well as 10 sqm on plan) including getting out and disposal of excavated earth lead upto 50 m and lift upto 1.5m, as directed by Engineer-in-charge. In All kinds of soil. |
| 208 | Providing and laying in position cement concrete of specified grade excluding the cost of centering and shuttering - All work up to plinth level: In Mix proportion 1:3:6 (1 Cement : 3 coarse sand (zone-III) : 6 graded stone aggregate 20 mm nominal size). |
| 209 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement : 6 coarse sand : 12 graded stone aggregate 20 mm nominal size) upto plinth level with : Cement mortar 1:6 (1 cement : 6 coarse sand). |
| 210 | 20 mm thick of mix: Mix 1:4 (1 cement: 4 fine sand). |
| 211 | Painting of water level pillar at both Left and Right bank Pillar of Myntdu Leshka Dam. |
| 212 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 213 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer’s specifications including appropriate priming coat, preparation of surface, etc. complete: On concrete work |
| 214 | Printing New Letters and Figures of Any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per Technical Specification: English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 100 cm height i.e 1.60 m or 1600 cm: For Right Bank (20cm Height). |
| 215 | Printing New Letters and Figures of Any Shade Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per Technical Specification: English and Roman Hyphens, commas and the like not to be measured and paid for. Detail for 100 letters of 100 cm height i.e 1.60 m or 1600 cm: For Dots & Arrow (5cm Height). |
| 216 | ProvidingPipe Line Water for Water Supply From Source to Staff Quarter and Control Room at Myntdu Leshka Dam (Right Bank). |
| 217 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In All kinds of soil. |
| 218 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge. In Walls (any thickness) including attached pilasters, buttresses, plinth and string courses etc (using steel). |
| 219 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage,lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): In Mild steel and Medium Tensile steel bars. |
| 220 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: In mix M20 or 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal sizederived from natural sources). |
| 221 | Cement plasterin mix 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster. |
| 222 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 32 mm dia nominal bore. |
| 223 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 25 mm dia nominal bore. |
| 224 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 25 to 40 mm nominal bore |
| 225 | Providing and fixing brass bib cock of approved quality:15 mm nominal bore. |
| 226 | Providing and fixing brass stop cock of approved quality: 15 mm nominal bore. |
| 227 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work): 25 mm nominal bore. |
| 228 | ProvidingPipe Line Water for Water Supply From Source to Staff Quarter and Control Room at Myntdu Leshka Dam (Leftt Bank). |
| 229 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, lift upto 1.5 m, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m. In All kinds of soil. |
| 230 | Centering and shuttering including strutting, proppingetc. and removal of form for all heights complete and as directed by Engineer in charge: In Walls (any thickness) including attached pilasters, buttresses,plinth and string courses etc (using steel). |
| 231 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage,lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Mild steel and Medium Tensile steel bars. |
| 232 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor five level, excluding cost of centering, shuttering, finishing and reinforcement: In Mix M20 or 1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) : 3 graded stone aggregate 20 mm nominal size). |
| 233 | Cement plaster in mix 1:3 (1 cement: 3 coarse sand) finished with a floating coat of neat cement.20 mm cement plaster. |
| 234 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc. 80 mm dia nominal bore. |
| 235 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc: 50 mm dia nominal bore. |
| 236 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 32 mm dia nominal bore |
| 237 | Providing and fixing G.I. pipes complete with G.I. fittings including trenching and refilling etc.: 25 mm dia nominal bore. |
| 238 | Making connection of G.I. distribution branch with G.I. main of following sizes by providing and fixing tee, including cutting and threading the pipe etc. complete: 25 to 40 mm nominal bore |
| 239 | Providing and fixing brass bib cock of approved quality :15 mm nominal bore. |
| 240 | Providing and fixing brass stop cock of approved quality :15 mm nominal bore. |
| 241 | Providing and fixing gun metal gate valve with C.I. wheelof approved quality (screwed end): 80 mm nominal bore |
| 242 | Providing and fixing G.I. Union in G.I. pipe including cutting and threading the pipe and making long screws etc. complete (New work) :25 mm nominal bore |
| 243 | Providing and fixing Sign board/name plates showing the salient feature of Myntdu Leshka Dam stage-I |
| 244 | Printing New Letters and Figures of Any Shade: Printing new letter and figures of any shade with synthetic enamel paint black or any other approved colour to give an even shade as per Technical Specification Clause 1701: English and Roman: Hyphens, commas and the like not to be measured and paid for: Detail for 100 letters of 100 cm height i.e 1.60 m or 1600 cm. |
| 245 | Supported on mild steel angle iron post 75 mm x 75 mm x 6 mm: Providing and fixing of retro-reflectorised cautionary, mandatory and informatory sign as per IRC: 67 made of encapsulated lens type reflective sheeting vide clause 1701.2.3 fixed over Aluminium Sheeting 1.5 mm thick supported on a Mild Steel Angle Post 75 mm x 75 mm x 6 mm firmly fixed to the ground by means of properly designed foundation with M15 grade cement concrete 450 mm x 450 mm x 600 mm, 600 mm below ground level as per drawing and directed by the Engineer Incharge. |
| 246 | Steel work welded in built up sections/framed work including cutting, hoisting, fixing in position and applying a priming coat Of approved steel primer using structural steel eta. as required: .ln gratings, frames, guard bar, ladder, railings, brackets, gates and similar works.ISA 7575 : 75*75*6mm. |
| 247 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils:In All kinds of soil (ordinary soil/ hard soil/ dense soil). |
| 248 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately). In mix 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size). |
| 249 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars (TMT). |
| 250 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 251 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge. Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 252 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 m.With available excavated earth. |
| 253 | 12 mm cement plaster of mix: 1 :4 (1 cement: 4 fine sand) |
| 254 | Turfing on both sides of the downstream at Myntdu Leshka Dam Stage-I: |
| 255 | Downstream Turfing:-Sodding the slopes with grass seeds including raising and preparing groung spreading a layer of good earth upto a depth of 300mm (average) wherever required (cost of earth included) watering rolling etc.complete as per direction within a initial leadof 50 meters and lift of 1.5 meters (for additional leads and lifts,paymentare to be madeas per the related earthwork items). |
| 256 | Renovation of Inspection Bungalow of Myntdu Leshka H.E. Project at Thamar. |
| 257 | Renovation of Doors, Windows and Ventilators at Ground Floor Level of Inspection Bungalow Thamar. |
| 258 | Dismantling doors, windows and clerestory windows (steel or wood) shutter including chowkhats, architrave, hold fasts etc complete and stacking within 50 metres lead: of area beyond 3 sqm. |
| 259 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make contorming to ls:733 and ls:1285, fixing with dash fasteners of required diameter and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitredand jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P.brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, and panelling to be paid for separately): For shutters of doors and windows and ventilators including providing hinges/pivots and making provision for fixing of fitting wherever required including the caused EPDM rubber/neo print gasket required (fitting shall be paid seperately). Anodised aluminium (anodised transparent or dyed to required shade according to ls:1868, Minimum anodic coating Of grade AC 15). |
| 260 | Filling the gap in between aluminium frame & adjacent RCC/ Brick/ Stone work by providing weather silicon sealant over backer rod of approved quality as per architectural drawings and direction of Engineer-in-charge complete. |
| 261 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 4.0 mm thick glass panes. |
| 262 | Finishing walls with toxtured exterior paint of required shade, including scaffolding: Old work ITwo or more coats on existing cement paint surface applied @ 3.28 ltr/10 sqm. |
| 263 | Providing and applying Plaster of Paris putty of 2 mm thickness over plastered surface to prepare the surface even and smcoth complete. |
| 264 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Two or more coats applied on walls @ 1.25 Itr/10 sqm over sqm 128.00 and including one coat of Special primer applied @ 0.75 ltr/10 Sqm |
| 265 | Renovation of Sanitary Fittings at Ground Floor Level and Water Supply Pipe Lines at Inspection Bungalow Thamar. |
| 266 | Providing and fixing CP Brass Single lever telephonic wall mixer quality & make as approved by Engineer - In - Charge. |
| 267 | Providing and fixing c.P. brass shower rose with 15 or 20 mm inlet: 100 mmm diamete. |
| 268 | Providing and fixing wash basin with C.I. brackets, 15 mm dia. CP Brass single hole basin mixer Of approved quality and make, including painting Of fittings and brackets, cutting and making good the walls wherever required:-White Vitreous China Wash basin size 550x400 mm with a 15mm CP Brass single hole basin mixer: 15 mm nominal bore |
| 269 | Providing and fixing white vitreous china pedestal for wash basin completely recessed at the back for the reception Of pipes and fittings: |
| 270 | Providing and Fixing P.V.C waste pipe for sink and wash basin including P.V.C. waste fitting complete: Flexible Pipe:32 mm dia and 40 mm dia. |
| 271 | Providing and fixing PTMT Waste Coupling for wash basin and sink, of approved quality and colour. |
| 272 | Providing and Fixing plain of required degree with cast iron S&S as per IS: 1729 : 100 mm dia. |
| 273 | Providing and fixing brass bib cock of approved quality: 20 mm nominal bore, 120 mm long, weighing not less than 198 gins. |
| 274 | Providing and fixing toilet paper holder : C.P. Brass. |
| 275 | Providing and fixing PTMT towel ring t Tapezoidal shape 215 mm long, 200 mm wide with minimilm distances of 37 mm from wall face with concealed fittings arrangemem Of approved quality and colour, weighing not less than 88 gins. |
| 276 | Providing and fixing PTMT towel rail complete with brackets fixed to wcoden cleats with CP brass screws with concealed fittings arrangement of approved quality and colour 600mm. |
| 277 | Providing and fixing PTMT liquid soap container 109 mm wide, 125 mm high and 112 mm distance from wall Of standard shape with bracket Of the same materials with snap fittings of approved qualfty and colour, weighing not less than 105 gins. |
| 278 | Providing and fixing 600×450 mm bevelled edge mirror of superior glass (or approve quality) complete with 6mm thick hard board ground like wooden cleats with C.P. Brass screws and washer complete. |
| 279 | Providing and fixing 600×120×5 mm glass shelf with edges round off supported and nodised alluminium anngle frame C.P. brass bracket Guard rail complete fixed with 40mm long screws rawl plug ext complete. |
| 280 | Providing and fixing door piece, insertion rLibber washer 3mm thick, bolts & nuts complete with sand cast iron S&S as per direction of the Engineer Incharge. |
| 281 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc, with 20 mm nominal outer diameter pipes. |
| 282 | Providing Cement Concrete Topping including Water Proofing Course at Roof Level and Repairs to Plaster in Parapet Wall of Inspection Bungalow Thamar. |
| 283 | Hacking of CC flooring including cleaning for Surface etc. complete as per direction of the Engineer-in-Charge. |
| 284 | Dismantling 15 to 40 mm dia. G.I, pipe including slacking of dismantled pipes (within 50 metres lead) as per direction of Engineer-in-Charge; Internal Work- Exposed on wall. |
| 285 | 65 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 15 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture\"s specifications. This includes cost of cement slurry, complete. |
| 286 | Repairs to plaster ot thickness 12 mm to 20 mm in patches Of area 2.5 sqm and under, including cutting the patch in proper shape, ral |
| 287 | Electrification at Ground Floor Level of Inspection Bungalow Thamar including Street Lighting in IB compound. |
| 288 | Supplying fitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb : 40 W |
| 289 | Supplying fitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Candle LED Bulb: 5 W |
| 290 | Supplying fitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Filament LED Bulb: 8 W |
| 291 | Supplying fitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Emergency LED Bulb:9 W |
| 292 | Supplying fitting, fixing of LED RETROFIT LAMPS surface or wall mounted with all necessary accessories:Regal battern for LED Tube Light (Universal batten for T-5 & T - 8 Lamps:8 upto 2×22W |
| 293 | Supplying fitting, fixing of LED RETROFIT LAMPS surface or wall mounted with all necessary accessories:Crystal Glass LED Tube Light (Double Size Connection):18 W |
| 294 | Supplying fitting and fixing LED down light surface or wall mounted with all necessary accesories:Round Slim fit low profile down light are engineered to delivered superior light out put and uniformity using the latest aged - lit LED technology: 15 W Ceiling cut out Ø 180 mmheight 16 mm Round shape. |
| 295 | Supplying fitting and fixing of Wall/Table Fan with all necessary attachments and accessories as required:400mm Wall Fan. |
| 296 | Supplying fitting and fixing exhaust fan double bearing self duplicating type single phase 50Htz 250 V AC Operated complete with supporting frame fan blade nuts and bolts and others petty as accesories required:Domestic exhaust Fan:Metal Exhaust Fan 225 mm. |
| 297 | Supplying fitting and fixing waterheater (Geyser) of 1.5 Kw/with pressure value including all necessary accesirie required: 35 Litres Capacity. |
| 298 | Aesthetically designed decorative hot dipped galvanized mild steel step pole with grey powder finished, plasma cut and duly chamfeared opening window of 300 × 110 mm for terminal connection and mounting accessories window cover is fitted with allen screw to the pole: 4 metre poles. |
| 299 | Drawing of 3 phase main line with DGSD approved VIR or PVC 660 volt grade copper conducter in casing caping with all accessories: With 4 × 10 mm2 Copper conductor. |
| 300 | Supplying and fixing load kontaket miniature circuit Brakes RX3: Single pole MCB: 6 - 32 Amp. |
| 301 | Supplying and fixing load kontaket miniature circuit Brakes RX3: Tripple pole MCB:6 - 32 Amp |
| 302 | Supplying fitting and fixing of RX3 Isolator (35 sq. mm cage terminals with safety shutters): Double Pole: 40 Amp. |
| 303 | Supplying fitting and fixing of Distribution board ETPN DB\"s for MCB, Isolator, RCCB and RCBO: IP 30 # 1k 08 Mouble Pole. |
| 304 | Supplying fitting and fixing earthing with G.I. pipe of 200cm lay 40\" dia icluding all accessories & providing masonry enclosure with cover plate having locking arrangement etc with charcoal salt complete as required: G.I. Pipe. |
| 305 | Supplying fitting and fixing earthing with copper Plate 600 × 600 mm × 6mm thick including accessories & providing masonry enclosure with cover plate having locking arrangement & watering pipe etc with charcoal, salt etc complete as required: Copper earth plate electrode. |
| 306 | Security Outpost at the Entrance to Inspection Bungalow Thamar. |
| 307 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal Of surplus earth with all lead and lifts as directed and specified for the following classification of soils: In All kinds of soil (ordinary soil/ hard soil/ dense soil). |
| 308 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing thesubgrade as directed including all labour and materials and if necessary dewatering, complete: Stone soling. |
| 309 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): In Mix 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20mm nominal size). |
| 310 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C.work/ a.a. walling including straightening, cleaning, cuttingand bending to proper shapes and length as per details,supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): High Yield Strength Deformed bars. |
| 311 | Centering and shutteilng including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge:In Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
| 312 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost Of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: In M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 313 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with:Cement mortar 1 :6 (1 cement: 6 coarse sand) |
| 314 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation otc in layers not exceeding 20 cm thick including breaking Of clods, consolidating each layer by ramming and watering, lead up to 50 in and lift up to 1.5 m:With borrowed earth/stone dust carriage up to 5 Km. |
| 315 | 65 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 15 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture\"s specifications. This includes cost of cement slurry, complete. |
| 316 | Brick work in cement mortar with first class brick in superstructure above plinth level up to first floor level in all shapes and sizes: In Cement mortar 1:6(1 cement: 6 coarse sand. |
| 317 | Providing and fixing aluminium work for doors, windows, ventilators and partitions with extruded built up standard tubular sections/ appropriate Z sections and other sections of approved make conforming to IS:733 and IS:1285, fixing with dash fasteners of required diameter and size, including necessary filling up the gaps at junctions, i.e. at top, bottom and sides with required EPDM rubber/ neoprene gasket etc.Aluminium sections shall be smooth, rust free, straight, mitredand jointed mechanically wherever required including cleat angle, Aluminium snap beading for glazing/ panelling, C.P.brass/ stainless steel screws, all complete as per architectural drawings and the directions of Engineer-in-charge. (Glazing, and panelling to be paid for separately): For fixed portion: Anodised aluminium (anodised transparent or dyed to required shade according to ls:1868, Minimum anodic coating of grade AC 15). |
| 318 | 12 mm cement plaster of mix 1 :4 (1 cement: 4 fine sand) |
| 319 | Boundary Fencing for Inspection Bungalow at Thamar. |
| 320 | Applying priming coat:With ready mked pink or Grey primer Of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. |
| 321 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation Of surface, etc. complete: On steel work. |
| 322 | Finishing with Epoxy paint (two or more coats) at all locations prepared and applied as per manufacturer\"s specifications including appropriate priming coat, preparation Of surface, etc. complete: On concrete work. |
| 323 | Fencing with angle iron post placed at required distance embedded in cement concrete blocks, every 15th post, last but one end post and corner post shall be strutted on both sides and end post on one side only and provided with horizontal lines and two diagonals interwoven with horizontal wires, of barbed wire weighing 9.38 kg per loo in (minimum), between the two posts fitted and fixed with G.I. staples, turn bucl(les etc. complete. (Cost of posts, struts, earth work and concrete work to be paid for separately). Payment to be made per metre cost of total length of barbed wire used: With G.I. barbed wire. |
| 324 | Transit Camp at Myntdu Leshka Stage-I HEP |
| 325 | Earthwork in excavation by manual means up to a depth of 2m below the existing ground level for foundation trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils with All kinds of soil (ordinary soil/ hard soil/ dense soil). |
| 326 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete with Stone soling 100mm. |
| 327 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1 :6 (1 cement: 6 coarse sand). |
| 328 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately) with 1 :3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 329 | Earthwork in filling (excluding rock) in trenches, plinth, sides of foundation etc in layers not exceeding 20 cm thick including breaking of clods, consolidating each layer by ramming and watering, lead up to 50 m and lift up to 1.5 m With available excavated earth. |
| 330 | 65 mm thick cement concrete flooring with concrete hardener topping, under layer 50 mm thick cement concrete 1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) and top layer 15 mm thick cement hardener consisting of mix 1 :2 (1 cement hardener mix: 2 graded stone aggregate, 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacture\"s specifications. This includes cost of cement slurry, complete. |
| 331 | Supplying, fitting and fixing in position reinforcement bars up to 1st floor level, conforming to relevant I.S. Code for R.C.C. work/R.B. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) with Thermo-Mechanically Treated bars. |
| 332 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
| 333 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
| 334 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: Columns, Pillars, Piers, Abutments, Posts and Struts (using steel). |
| 335 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centering, shuttering, finishing and reinforcement- All work up to plinth level: M20 or 1:11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 336 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns,pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 337 | Reinforced cement concrete work in beams, slabs, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to first floor level, excluding the cost of centerlng, shuttering, finishing and reinforcement: M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 338 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) trusses etc„ including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer, including welding and bolted with special shaped washers etc. complete. |
| 339 | Providing and fixing pre-coated galvanised iron profile sheets (size, shape and pitch Of corrugation as approved by Engineer-in-charge) 0.50 mm(+O.05 a/o) total coated thickness with zinc coating 120 grams per sqm as per ls:277, in 240 Mpa steel grade, 5-7 microns epoxy primer on both side of the shect and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length up to 12 mcter or as desired by Engineer-in charge. The sheet shall be fixed using selfrdrilling/ self tapping screws of size (5.5x55 mm) with EPDM seal,complete up to any pitch in horizontav vertical or ciirved surfaces, excluding the cost of purlins. rafters and trusses and including cutting to size and shape wherever required. |
| 340 | Providing and fixing pro-coated galvanised steel sheet rcofing accessories 0.50 mm (+0.05 a/a) total coated thickness, Zinc coating 120 grams per sqm as per ls:277, in 240 Mpa Steel grade, 5-7microns epoxy primer on both side Of the shect and polyester top coat 15-18 : Plidges plain (500-600mm) |
| 341 | Providing and fixing pro-coated galvanised steel sheet rcofing accessories 0.50 mm (+0.05 a/a) total coated thickness, Zinc coating 120 grams per sqm as per ls:277, in 240 Mpa Steel grade, 5-7microns epoxy primer on both side Of the shect and polyester top coat 15-18 : Gutter (600 mm over all girth) |
| 342 | Providing wood work in frames of false ceiling, partitions, etc. sawn and fixed in position with necessary stainless steel screws ctc. With lst class Local wood Pooma/ Hollock/ Gamari and the like |
| 343 | Providing and fixing insulating board ceiling of approved quality with necessary nails etc. complete (frame work to be paid separately) : Natural colour insulating board 12 mm thick. |
| 344 | Half brick masonry with common burnt clay (non modular) 1st class bricks in superstructure above plinth level up to first floor level: Cement mortar 1 :4 (1 cement: 4 coarse sand) |
| 345 | Providing wood work in frames of doors, windows, clerestory windows and other frames, wrought framed and fixed in position with hold fast lugs or with dash fasteners of required diameter & length With Teak wood / Sissu wood. |
| 346 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) With Teak wood / Sissu wood, 35 mm thick shutters. |
| 347 | Providing, fitting and fixing steel windows (including ventilators) of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15x3x100 mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65 mm and not less than 15 mm wide) bolting device, steel handles, pegs, stays of 300 mm long etc. complete including providing 12x12 mm square bars duly welded to steel frame at not more than 12 cm c/c applying a priming coat of red-lead paint etc. complete as per drawing: Openable. |
| 348 | Providing and fixing M.S. grills Of required pattern in trames Of windows, etc. with M.S. flats, square or round bars, etc. including priming coat with approved steel primer all complete Fixed to openings/ wooden frames with rawl plugs screws etc. |
| 349 | Providing and fixing water closet squatting pan (Indian type W.C. pan) with 100 mm sand Cast Iron P or S trap, 10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever) conforming to ls:7231, with all fi\"ngs and fixtures complete. including cutting and making good the walls and floors wherever required: White Vitreous china Orissa pattern W.C, pan of size 580x440 mm with integral type foci rests. |
| 350 | Providing and fixing white vitreous china pedestal type water closet (European type) with seat and lid, 10 litre low level white vitreous china flushing cistern & C.P, flush bend with fittings & C.I. brackets, 40 mm flush bend, overflow arrangement with specials Of standard make and mosquito proof coupling Of approved design complete, including painting Of fittings and brackets, cutting and making good the walls and floors wherever required: W.C. pan with lsl marked white solid plastic seat and lid. |
| 351 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern. including painting of fittings and brackcts, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps |
| 352 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern. including painting of fittings and brackcts, cutting and making good the walls wherever require: White Vitreous China Wash basin size 550x400 mm with a pair of 15 mm C.P. brass pillar taps |
| 353 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per ls:13983 with C.I. brackets and stainless steel plug 40 mm, including painting Of fittings and brackets, cutting and making gcod the walls wherever required : Kitchen sink with drain board 510xl040 mm bowl depth 250 mm |
| 354 | Providing and fixing CP brass Single Lever Telephonic wall mixer of quality & make as approved by Engineer-in-charge. |
| 355 | Providing and fixing 600x450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick hard board ground fixed to wooden cleats with C.P. brass screws and washer complete. |
| 356 | Providing and fixing toilet paper holder: C.P. brass |
| 357 | Providing and fixing chlorinated polyvinyl chloride (CPVC) pipes, having thermal stability for hot & cold water supply, including all CPVC plain & brass threaded fittings, i/c fixing the pipe with clamps at 1.00 in spacing. This includes jointing of pipes & fittings with one step CPVC solvent cement and the cost of cutting chases and making good the same including testing of joints complete as per direction of Engineer in Charge. Concealed work, including cutting chases and making good the walls etc. 15 mm nominal outer diameter pipes. |
| 358 | Providing and fixing brass bib cock of approved quality 15 mm nominal bore. |
| 359 | Providing and fixing C.P. brass shower rose with 15 or 20 mm inlet: 150 mm diameter. |
| 360 | Providing and fixing C.P. brass angle valve for basin mixer and geyser points Of approved quality conforming to IS:8931 15 mm nominal bore. |
| 361 | Providing and fixing PTMT pillar cock of approved quality and colour 15 mm nominal bore, 107 mm long, weighing not less than 110 gins. |
| 362 | Providing and laying vitrified floor tiles in different sizes (thickness to be specif led by the manufacturer) with water absorption less than O.08°/o and conforming to ls:15622, of approved make, in all colours and shades laid on 20 mm thick cement mortar 1:4 (1 cement: 4 coarse sand), jointing with grey cement slurry @ 3.3 kg/sqm including grouting the joints with white cement and matching pigments etc„ complete Size of Tile 600x600 mm. |
| 363 | Tile work in skirting, risers of steps and dado up to 2 in height over 12 mm thick bed of cement mortar 1:3 (1 cement: 3 coarse sand) and jointed with grey cement slurry @ 3.3 kg/sqm., including pointing in white cement mixed with pigment of matching shade complete. |
| 364 | 12 mm cement plaster of mix: 1:4 (1 cement : 4 fine sand) |
| 365 | Distempering with oil bound washable distemper of approved brand and manufacture to give an even shade: New work (two or more coats) over and including water thinnable priming coat with cement primer |
| 366 | Applying priming coat:With ready mked pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood |
| 367 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Painting wood work with Deluxe Mufti Surface Paint of required shade. Two or more coats applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.75 Itr/10 sqm of approved brand and manufacture. |
| 368 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture. |
| 369 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 5.5 mm thick glass panes |
| 370 | A. SEPTIC TANK |
| 371 | Earthwork in excavation by Mechanical means up to a depth of 2 in below the existing ground level tor foundation, trenches Of foundations, footings Of column/ walls,etaining walls,septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification Of soils. All kinds of soil (ordinary soil/ hard soil/dense soil). |
| 372 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete with Stone soling 100mm. |
| 373 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately) with mix 1 :3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 374 | Brick work with common burnt clay modular ls\" class bricks in exposed brick work including making horizontal and vertical grooves 10 mm wide 12 mm deep complete in cement mortar 1:6 (1 cement: 6 coarse sand) From ground level up to plinth level |
| 375 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) with Thermo-Mechanically Treated bars. |
| 376 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required) with Mild steel and Medium Tensile steel bars |
| 377 | Centering and shuttering lncluding struttlng, propplng etc. and removal of form for all heights complcte and as directed by Engineer in charge. Lintels, beams, plinth beams, girders, bressumers and cantilevers (using steel). |
| 378 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge. Slabs, roofs, landings, balconies and access platform, shelves (using steel). |
| 379 | Reinforced cement concrete work in beams, slabs, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to first flcor level, excluding the cost of centerlng, shuttering, finishing and reinforcement. M20 or 1:1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size). |
| 380 | 20 mm cement plaster of mix:1 :4 (1 cement: 4 fine sand) |
| 381 | Providing and laying in position specified grade of reinforced cement concrete, excluding the cost of centerjng, shuttering, finishing and reinforcement- All work up to plinth level: M15 or Prop.1 :2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 20 mm nominal size) |
| 382 | Providing and fixing soil, waste and vent pipes 100mm dia with Sand cast iron S&S pipe. |
| 383 | Providing and fixing bend of required degree with access door, insertion rubber washer 3 mm thick, bolts and nuts complete 100mm dia withSand cast iron S&S pipe. |
| 384 | Constructing soak pit 1.20xl.20xl.20 in filled with brickbats including S.W. drain pipe100mm diameter and 1.20 in long complete as per standard design. |
| 385 | B. INTERNAL WIRING |
| 386 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 1.5sqmm of approved quality using PVC casing capping including 5 amperes switch Indian best quality ceiling rose etc. capable to the highest point : Wall Light point: short point wiring upto 3 mts. |
| 387 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to a light Plug point when fixed elsewhere with continous earth wire complete:Short point wiring upto 3 mts. |
| 388 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x4sqmm of approved quality using PVC casing capping including 15 amperes switch/socket Indian best quality complete to Power Plug point with continous earth wire complete : Short point wiring upto 3 mts. |
| 389 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to Ceiling fan/ Exhaust fan point: Short point wiring upto 3 mts. |
| 390 | Drawing of main and sub main line with DGSD approved VIR or PVC 250/440 Volts grade copper conductor in PVC casing complete with all accessories:With 2x4mm2 Copper conductor |
| 391 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories:With 4x4mm2 Copper conductor |
| 392 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories: With 4x16mm2 Copper conductor |
| 393 | Supplying fitting andfixing of industrial type 15 Amp complete with all necessary accessories as required with 15 Amp type socket |
| 394 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required:(75mmx75mm x 60mm deep) |
| 395 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required:(100mmx100mm x 60mm deep) |
| 396 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required: (150mmx75mm x 60mm deep) |
| 397 | Suppying and fitting of ceiling fan AC operated type 220/250 volt. Complete with 3 Nos of blades down rod canopy haning shackle & 30mm length of down rod supplied with the fan by the dealer but the extra length will be charged @ Rs 25.00/mtrs withAC ceiling Fan \"600\"mm sweep |
| 398 | Supplying fittings and fixing complete heavy duty double break fuse switches- HBC fuse type in sheet enclosure 50 Hz.415V. 3 pole with Neutral (T.P.N): 63Amp capacity |
| 399 | Supplying fitting and fixing of distribution board,ETPN DB\"s for MCB, Isolator, RCCB and RCBO: IP 30-#1K 08 with 8 ways 8+24 modules |
| 400 | Supplying and fixing of load Kontaket Miniature Circuit Breakers DX3 MCB\"s for AC application till 63ADouble pole 415 V with 6-32 Amp |
| 401 | Supplying fitting and fixingof DX3 Isolators for AC applications upto 125A Double pole 240 Vwith 63Amp |
| 402 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 15 litres capacity. |
| 403 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 3 litres capacity |
| 404 | Supplying, fitting and fixing earthing with copper earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeetc. with charcoal/ coke and salt etc complete as required |
| 405 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories:Bulb 23W |
| 406 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb3W |
| 407 | Supplyingfitting fixing of LED batten surface or wall mounted with all necessary accessories: with polycarbonate housing & integrated electronic driver with 20W (1150x 25x40mm) |
| 408 | Suppling fitting and fixing of LED PANEL LIGHTING surface or wall mounted with all necessary accessories: 2x2 (595x595x65)mm luminaire 24W |
| 409 | Supply, installation, testing & commisioning of advanced Lightning protection system by using high pulse Ion generator of E.S.E. lightning conductor made of high quality stainless steel, as specified and directed by the deptt. [ as per NFC17-102], Make: PROTART or SCHIRTEC with lightning strike counter & lightning conductor Tester chemical earthing electrode copper coated 50mm Dia. & 2.0m length with ERIC grounding material, 75mm single core copper wire with all accessories for installation etc. |
| 410 | Type-VI 3 (Three) Storied RCC building at Myntdu Leshka |
| 411 | Earthwork in excavation by Mechanical means up to a depth of 2 in below the existing ground level tor foundation, trenches Of foundations, footings Of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification Of soils.All kinds of soil (ordinary soiv hard soil/dense soil) |
| 412 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete:Stone soling100mm |
| 413 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete: Stone soling150 mm |
| 414 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1 :6 (1 cement: 6 coarse sand) |
| 415 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level: Cement mortar 1 :4 (1 cement: 4 coarse sand) |
| 416 | Extra over item No 7.8 and 7.10 above tor each subsequentfloor or part thereof above the first floor level. |
| 417 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): 1 :3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size) |
| 418 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge: Columns, Pillars, Piers, Abutments, Posts and struts (using steel). |
| 419 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge:Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick. |
| 420 | Centering and shuttering lncluding strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge:Slabs, roofs, landings, balconies and access platform, shelves (using steel) |
| 421 | Centering and shuttering lncluding strutting, propping etc. and removal of form for all heights complete and as directed by Engineer in charge:Stairs/ spiral staircase, (excluding landings) (using timber) |
| 422 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars |
| 423 | Reinforced cement concrete work in walls (any thickness), including attached pilasters, buttresses, fillets, columns, pillars, posts and struts etc. above plinth level up to first floor level, excluding cost of centering, shuttering, finishing and reinforcement: M20 or 1 :11/2:3 (1 cement: 11/2 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 424 | 12 mm cement plaster of mix: 1 : 4 (1 cement : 4 fine sand) |
| 425 | Providing, fitting and fixing steel windows (including ventilators) of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15x3xl00 mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65 mm and not less than 15 mm wide) bolting device, steel handles, pegs, stays of 300 mm long etc. complete including providing 12xl2 mm square bars duly welded to steel frame at not more than 12 cm c/c applying a priming coat of red-lead 1 1 .24 paint etc. complete as per drawing: Openable |
| 426 | Providing wood work in frames Of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length With lst class Local wood: Champa/ Diengrai. |
| 427 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately): With lst class Local woodChampa/ Diengrai 35 mm thick shutters. |
| 428 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core Of block board construction with frame of 1 St class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: 35 mm thick including lsl marked Stainless Steel butt hinges with necessary screws. |
| 429 | Providing and fixing bright finished brass butt hinges with necessary screws etc. complete: 125x85x5.5 mm (heavy type) |
| 430 | Providing and fixing bright finished brass tower bolts (barrel type) with necessary screws etc. complete: 250xl0 mm |
| 431 | Providing and fixing bright finished brass handles with screws etc. complete: 125 mm |
| 432 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 4.O mm thick glass panes |
| 433 | Providing and fixing 1st quality ceramic glazed floor tiles conforming to ls:15622 (thickness to be specified by the manufacturer) of approved make in all colours and shades of any size as approved by Engineer-in-Charge in skirting, risers Of steps and dados over 12 mm thick bed of cement Mortar 1 :3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 434 | Providing polished VITRlFIED wall tiles of approved quality, size, shape and thickness not less than 8 mm on walls and skirting over cement mortar bed 10 mm thick in prop.1:3 (1 cement: 3 coarse sand) including cutting where necessary finished with flush pointing with adhesive or white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed: Deluxe range. |
| 435 | Precast terrazzo tiles 22 mm thick with graded marble chips of sizes up to 12 mm, in skirting and risers Of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1 :3 (1 cement: 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of: Light shade pigment using white cement |
| 436 | Extra for marble stone flcoring, skirting, in treads of steps and sqm 514.00 risers using single length up to 2.00 metre. |
| 437 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Two or more coats applied on walls @ 1.25 Itr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 Sqm |
| 438 | Providing and fixing wooden rounded hand rails in straight lengths with size of 100x60 mm complete as directed: With lst class Local wood (Champa/ Diengrai and the like). |
| 439 | Providing and fixing 25x25 mm first class timber balustrade 25x25 mm square, wrought fixed with ends housed (square or splayed) to hand rails and trends or strips complcte. With lst class Local wood (Champa/ Diengrai and the like). |
| 440 | Applying priming coat: With ready mixed red oxide zinc chromate primer of approved brand and manufacture on steel galvanised iron/ steel works |
| 441 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. |
| 442 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: New work (two or more coats). |
| 443 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture: New work. |
| 444 | Internal Wiring:Wiringin looping system with copper PVC cable 250/440 volt grade of size 1.5sqmm of approved quality using PVC casing capping including 5 amperes switch Indian best quality ceiling rose etc. capable to the highest point:Wall Light point: Short point wiring upto 3 mts. |
| 445 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to a light Plug point when fixed elsewhere with continous earth wire complete:Short point wiring upto 3 mts. |
| 446 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x4sqmm of approved quality using PVC casing capping including 15 amperes switch/socket Indian best quality complete to Power Plug point with continous earth wire complete : Short point wiring upto 3 mts. |
| 447 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to Ceiling fan/ Exhaust fan point: Short point wiring upto 3 mts. |
| 448 | Drawing of main and sub main line with DGSD approved VIR or PVC 250/440 Volts grade copper conductor in PVC casing complete with all accessories: With 2x4mm2 Copper conductor |
| 449 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories: With 4x4mm2 Copper conductor. |
| 450 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories: With 4x16mm2 Copper conductor. |
| 451 | Supplying fitting andfixing of industrial type 15 Amp complete with all necessary accessories as required:15 Amp type socket. |
| 452 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required. (75mmx75mm x 60mm deep). |
| 453 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required.(100mmx100mm x 60mm deep) |
| 454 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required.(150mmx75mm x 60mm deep) |
| 455 | Suppying and fitting of ceiling fan AC operated type 220/250 volt. Complete with 3 Nos of blades down rod canopy haning shackle & 30mm length of down rod supplied with the fan by the dealer but the extra length will be charged @ Rs 25.00/mtrs.AC ceiling Fan \"600\"mm sweep. |
| 456 | Supplying fittings and fixing complete heavy duty double break fuse switches- HBC fuse type in sheet enclosure 50 Hz.415V. 3 pole with Neutral (T.P.N): 63Amp capacity. |
| 457 | Supplying fitting and fixing of distribution board,ETPN DB\"s for MCB, Isolator, RCCB and RCBO. IP 30-#1K 08:8 ways 8+24 modules |
| 458 | Supplying and fixing of load Kontaket Miniature Circuit Breakers DX3 MCB\"s for AC application till 63A:Double pole 415 V : 6-32 Amp |
| 459 | Supplying fitting and fixingof DX3 Isolators for AC applications upto 125A: Double pole 240 V - 63Amp. |
| 460 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 15 litres capacity |
| 461 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 3 litres capacity. |
| 462 | Supplying, fitting and fixing earthing with copper earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeetc. with charcoal/ coke and salt etc complete as required. |
| 463 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories:Bulb - 23W. |
| 464 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb - 3W |
| 465 | Supplyingfitting fixing of LED batten surface or wall mounted with all necessary accessories: with polycarbonate housing & integrated electronic driver: 20W (1150x 25x40mm). |
| 466 | Suppling fitting and fixing of LED PANEL LIGHTING surface or wall mounted with all necessary accessories:2x2 (595x595x65)mm luminaire :24W. |
| 467 | Supply, installation, testing & commisioning of advanced Lightning protection system by using high pulse Ion generator of E.S.E. lightning conductor made of high quality stainless steel, as specified and directed by the deptt. [ as per NFC17-102], Make: PROTART or SCHIRTEC with lightning strike counter & lightning conductor Tester chemical earthing electrode copper coated 50mm Dia. & 2.0m length with ERIC grounding material, 75mm single core copper wire with all accessories for installation etc. |
| 468 | 2 (two) Storied Dormitory of 20(twenty) beds at Myntdu Leshka Stage-I |
| 469 | Earthwork in excavation by Mechanical means up to a depth of 2 in below the existing ground level tor foundation, trenches of foundations, footings of column/ walls, retaining walls, septic tank etc. including bailing out water where necessary and removal of surplus earth with all lead and lifts as directed and specified for the following classification of soils: All kinds of soil (ordinary soil/ hard soil/dense soil). |
| 470 | Providing soling with stone/ best quality picked jhama brick, sand packed and laid to level and in panel after preparing the subgrade as directed including all labour and materials and if necessary dewatering, complete. Stone soling150mm. |
| 471 | Random rubble masonry with hard stone in foundation and plinth including levelling up with cement concrete 1:6:12 (1 cement: 6 coarse sand: 12 graded stone aggregate 20 mm nominal size) up to plinth level with: Cement mortar 1:6 (1 cement: 6 coarse sand). |
| 472 | Half brick masonry with common burnt clay (non modular) lst class bricks in superstructure above plinth level up to first floor level in Cement mortar 1:3 (1 cement: 3 coarse sand). |
| 473 | Plain cement concrete works in foundation bed for footing steps, walls, brick works etc below plinth level as directed and specified including dewatering if necessary, and curing complete (shuttering where necessary shall be measured and paid separately): 1:3:6 (1 Cement: 3 coarse sand: 6 graded stone aggregate 20 mm nominal size). |
| 474 | Cement concrcte floor topping 1:1:2 (1 cement: 1 coarse sand: 2 stone aggregate) finished with a floating coat of neat cement, including cement slurry, complete. 20 mm thick |
| 475 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: Foundations, footings, bases of columns, etc. for mass concrete (using steel). |
| 476 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: Columns, Pillars, Piers, Abutments, Posts and struts (using steel) |
| 477 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: Slabs, roofs, landings, balconies and access platform, shelves (using steel). |
| 478 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: Stairs/ spiral staircase, (excluding landings) (using timber) |
| 479 | Centering and shuttering including strutting, propping etc. and removal of form for all heights complcte and as directed by Engineer in charge: Lintels, beams, plinth beams, girders, bressumers and cantilevers with water proof ply 12 mm thick |
| 480 | Supplying, fitting and fixing in position reinforcement bars up to lst floor level, conforming to relevant I.S. Code for Ft.C.C. work/ a.a. walling including straightening, cleaning, cutting and bending to proper shapes and length as per details, supplying and binding with 20 G annealed black wire and placing in position with proper blocks, supports, chairs, spacers etc. complete. (Rates inclusive of all wastage, lappage, hooks, chairs, anchorage etc. and no measurement for the same is required): Thermo-Mechanically Treated bars. |
| 481 | Reinforced cement concrete work in beams, slabs, roofs having slope up to 15°, landings, balconies, shelves, chajjas, lintels, bands, plain window sills, staircases and spiral stair cases above plinth level up to first floor level, excluding the cost of centerlng, shuttering, finishing and reinforcement: M20 or 1 :1.5:3 (1 cement: 1.5 coarse sand: 3 graded stone aggregate 20 mm nominal size) |
| 482 | 20 mm cement plaster of mix: 1 :4 (1 cement: 4 fine sand) |
| 483 | Providing, fitting and fixing steel windows (including ventilators) of standard rolled steel sections as per relevant I.S. Code, joints mitred and welded with 15x3xl00 mm lugs embedded in cement concrete block of M-10 grade including providing and fixing of projecting hinges (not more than 65 mm and not less than 15 mm wide) bolting device, steel handles, pegs, stays of 300 mm long etc. complete including providing 12xl2 mm square bars duly welded to steel frame at not more than 12 cm c/c applying a priming coat of red-lead paint etc. complete as per drawing and direction of the Engineer-in-charge. Openable. |
| 484 | Providing wood work in frames Of doors, windows, clerestory windows and other frames, wrought trained and fixed in position with hold fast lugs or with dash fasteners of required diameter & length. With lst class Local wood Champa/ Diengrai |
| 485 | Providing and fixing panelled or panelled and glazed shutters for doors, windows and clerestory windows fixing with butt hinges of required size with necessary screws, excluding panelling which will be paid for separately, all complete as per direction of Engineer-in-charge. (Note:- Butt hinges and necessary screws shall be paid separately) With lst class Local wood Champa/ Diengrai 35 mm thick shutters |
| 486 | Providing and fixing ISI marked flush door shutters conforming to IS:2202 (Part I) decorative type, core Of block board construction with frame of 1 St class hard wood and well matched teak 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters. 35 mm thick including lsl marked Stainless Steel butt hinges with necessary screws |
| 487 | Providing and fixing aluminium tower bolts, 1st marked, anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade, with necessary screws etc. complete:300mm X 10mm |
| 488 | Providing and fixing lst marked aluminium butt hinges anodised (anodic coating not less than grade AC 10 as per IS:1868) transparent or dyed to required colour or shade with necessary screws etc. complete: 125x75x4 mm |
| 489 | Providing & fixing glass panes with putty and glazing clips in steel doors, windows, clerestory windows, all complete with: 5.5 mm thick glass panes |
| 490 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Two or more coats applied on walls @ 1.25 Itr/10 sqm over and including one coat of Special primer applied @ 0.75 ltr/10 Sqm |
| 491 | Finishing with Deluxe Multi surface paint system for interiors and exteriors using Primer as per manufacturers specifications, including scaffolding: Painting Steel work with Deluxe Multi Surface Paint to give an even shade. Two or more coat applied @ 0.90 ltr/10 sqm over an under coat of primer applied @ 0.80 ltr/10 sqm of approved brand and manufacture |
| 492 | Applying priming coat: With ready mixed pink or Grey primer of approved brand and manufacture on wood work (hard and soft wood)/ with ready mixed aluminium primer of approved brand and manufacture on resinous wood and plywood. |
| 493 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade: New work (two or more coats). |
| 494 | Polishing on wood work with ready mixed wax polish of approved brand and manufacture New work. |
| 495 | Providing and fixing 1st quality ceramic glazed tloor tiles conforming to IS:15622 (thickness to be specified by the manufacturer) of approved make in all colours and shades of any size as approved by Engineer-in-Charge in skirting, risers Of steps and dados over 12 mm thick bed of cement Mortar 1:3 (1 cement: 3 coarse sand) and jointing with grey cement slurry @ 3.3 kg/sqm including pointing in white cement mixed with pigment of matching shade complete. |
| 496 | Providing polished VITRlFIED wall tiles of approved quality, size, shape and thickness not less than 8 mm on walls and skirting over cement mortar bed 10 mm thick in prop.1:3 (1 cement: 3 coarse sand) including cutting where necessary finished with flush pointing with adhesive or white cement slurry mixed with approved pigment to match shade of tiles complete at all levels as specified and directed. Deluxe range |
| 497 | Precast terrazzo tiles 22 mm thick with graded marble chips of sizes up to 12 mm, in skirting and risers Of steps not exceeding 30 cm in height, on 12 mm thick cement plaster 1:3 (1 cement: 3 coarse sand), jointed with neat cement slurry mixed with pigment to match the shade of the tiles, including rubbing and polishing complete with tiles of Medium shades pigment using 50°/o white cement and 50°/o ordinary cement. |
| 498 | 40 mm thick marble chips flooring, rubbed and polished to granolithic finish, under layer 28 mm thick cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded stone aggregate 12.5 mm nominal size) and top layer 12 mm thick with marble chips Of sizes from 7 mm to 10 mm nominal size, laid in cement marble powder mix 3:1 (3 cement: 1 marble powder) by weighi in proportion of 2:3 (2 cement marble powder mix: 3 marble chips) by volume, including cement slurry eta. complete: Medium shade pigment with 50°/a white cement and 50°/o ordinary cement |
| 499 | Providing and fixing white vitreous china pedestal type water closet (European type W.C. pan) with seat and lid,10 litre low level white P.V.C. flushing cistern, including flush pipe, with manually controlled device (handle lever), conforming to ls:7231, with all fittings and fixtures complete, including cutting and making good the walls and floors wherever required: W.C. pan with lsl marked white solid plastic seat and lid |
| 500 | Providing and fixing wash basin with C.I. brackets, 15 mm C.P. brass pillar taps, 32 mm C.P. brass waste of standard pattern. including painting of fittings and brackcts, cutting and making good the walls wherever require: White Vitreous China Wash basin size 630x450 mm with a pair of 15 mm C.P. brass pillar taps. |
| 501 | Providing and fixing Stainless Steel A ISI 304 (18/8) kitchen sink as per IS:13983 with C.I. brackets and stainless steel plug 40 mm, including painting Of fittings and brackets, cutting and making good the walls wherever required Kitchen sink with drain board 510xl040 mm bowl depth 250 mm. |
| 502 | Providing and fixing mirror of superior glass (of approved quality) and of required shape and size with plastic moulded frame of approved make and shade with 6mm thickhard board backing Circular shape 450 mm dia. |
| 503 | Providing and fixing toilet paper holder C.P brass. |
| 504 | Providing and fixing soil, waste and vent pipe 100mm diameter Sand cast iron S&S pipe. |
| 505 | Providing and fixing c.P. brass shower rose with 15 or 20 mm inlet: 100 mm diameter. |
| 506 | Providing and fixing G.I. Pipes complete with G.I. fittings and clamps, i/c making good the walls etc. concealed pipe, including painting with anti-corrosive bitumastic paint, cutting chases and making good the wall: 15 mm diameter nominal bore |
| 507 | Making connection of G.I. distribution branch with a.I. main of following sizes by providing and tixing tee, including cutting and threading the pipe ctc. complcte: 25 to 40 mm nominal bore |
| 508 | Providing and fixing brass stop cock of approved quality: 15 mm nominal bore. |
| 509 | Painting G.I. pipes and fittings with synthetic enamel white paint with two coats over a ready mixed priming coat, both of approved qualfty for new work: 15 mm diameter pipe |
| 510 | Providing and fixing stainless steel (Grade 304) railing made of Hollow tubes, channels, plates etc., including welding, grinding, buffing, polishing and making curvature (wherever required) and fitting the same with necessary stainless steel nuts and bolts complete, Vc fixing the railing with necessary accessories & stainless steel dash fasteners, stainless steel bolts etc., of required size, on the top of the floor or the side of waist slab with suitable arrangement as per approval of Engineer-in-charge, (for payment purpose only weight of stainless steel members shall be considered). |
| 511 | Internal Wiring:Wiringin looping system with copper PVC cable 250/440 volt grade of size 1.5sqmm of approved quality using PVC casing capping including 5 amperes switch Indian best quality ceiling rose etc. capable to the highest point: Short point wiring upto 3 mts. |
| 512 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to a light Plug point when fixed elsewhere with continous earth wire complete:Short point wiring upto 3 mts. |
| 513 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x4sqmm of approved quality using PVC casing capping including 15 amperes switch/socket Indian best quality complete to Power Plug point with continous earth wire complete : Short point wiring upto 3 mts. |
| 514 | Wiringin looping system with copper PVC cable 250/440 volt grade of size 2x2.5sqmm of approved quality using PVC casing capping including 5/15 amperes switch/socket Indian best quality complete to Ceiling fan/ Exhaust fan point: Short point wiring upto 3 mts. |
| 515 | Drawing of main and sub main line with DGSD approved VIR or PVC 250/440 Volts grade copper conductor in PVC casing complete with all accessories:With 2x4mm2 Copper conductor |
| 516 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories:With 4x4mm2 Copper conductor. |
| 517 | Drawing of 3 phasemain line 4 wire withDGSD approved VIR or PVC 660 Volts grade copper conductorcasing cappingwith all accessories.(b) With 4x16mm2 Copper conductor |
| 518 | Supplying fitting andfixing of industrial type 15 Amp complete with all necessary accessories as required:15 Amp type socket. |
| 519 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required:(75mmx75mm x 60mm deep) |
| 520 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required:(100mmx100mm x 60mm deep) |
| 521 | Suppyingfitting and fixing Metal box of following sizes on surface or in recess with suitable size of Phendie laminated sheet cover in the front including painting etc as required:(150mmx75mm x 60mm deep) |
| 522 | Suppying and fitting of ceiling fan AC operated type 220/250 volt. Complete with 3 Nos of blades down rod canopy haning shackle & 30mm length of down rod supplied with the fan by the dealer but the extra length will be charged @ Rs 25.00/mtrs:AC ceiling Fan \"600\"mm sweep |
| 523 | Supplying fittings and fixing complete heavy duty double break fuse switches- HBC fuse type in sheet enclosure 50 Hz.415V. 3 pole with Neutral (T.P.N): 63Amp capacity. |
| 524 | Supplying fitting and fixing of distribution board,ETPN DB\"s for MCB, Isolator, RCCB and RCBOA. IP 30-#1K 08: 8 ways 8+24 modules. |
| 525 | Supplying and fixing of load Kontaket Miniature Circuit Breakers DX3 MCB\"s for AC application till 63A: Double pole 415 V: 6-32 Amp. |
| 526 | Supplying fitting and fixingof DX3 Isolators for AC applications upto 125A: Double pole 240 V: 63Amp |
| 527 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 15 litres capacity. |
| 528 | Supplying fitting and fixing of water Heater (Geyser) of 1.5KW/3KW with pressure release valve including all necessary accessories as required: 3 litres capacity. |
| 529 | Supplying, fitting and fixing earthing with copper earth plate 600 mm X 600 mm X 6 mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipeetc. with charcoal/ coke and salt etc complete as required. |
| 530 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb - 23W |
| 531 | Supplyingfitting fixing complete polish brass bracket, 16mm dia and 23cm long with cast backplate and brass lamp holder with LED bulb surface or wall mounted with all necessary accessories: Bulb - 3W |
| 532 | Supplyingfitting fixing of LED batten surface or wall mounted with all necessary accessories: with polycarbonate housing & integrated electronic driver: 20W (1150x 25x40mm). |
| 533 | Suppling fitting and fixing of LED PANEL LIGHTING surface or wall mounted with all necessary accessories:2x2 (595x595x65)mm luminaire: 24W |
| 534 | Supply, installation, testing & commisioning of advanced Lightning protection system by using high pulse Ion generator of E.S.E. lightning conductor made of high quality stainless steel, as specified and directed by the deptt. [ as per NFC17-102], Make: PROTART or SCHIRTEC with lightning strike counter & lightning conductor Tester chemical earthing electrode copper coated 50mm Dia. & 2.0m length with ERIC grounding material, 75mm single core copper wire with all accessories for installation etc. |
Copyright © 2026 · All Rights Reserved. Terms of Usage | Privacy Policy