| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 21-11-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 26-11-2024 |
| 2 | 14-11-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-11-2024 |
| Sl. No. | Item Description |
| 1 | M&L for taking down carefully copper/aluminium point wiring (light, fan socket or power) complete including PVC casing capping/concealed conduit, fixture and fitting such as switches, ceiling roses, pendents, regulators, sockets, light fitting etc removing materials for taking credit and making good disturbed surface of walls, floors etc complete all as specified and directed. |
| 2 | M&L for taking down the existing unserviceable main switch/cut out/DBs of any type/capacity/description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 3 | M&L for taking down the existing unserviceable MCBs/MCCBs of any type/capacity/description as existing at site including necessary making good the disturbed surfaces to match with the existing finishes complete all as specified and directed. |
| 4 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) , with multistranded copper conductor 1. 5 sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. in and inciuding medium grade, PVC casing caping/surface conduit and accessories on wall/roof/floor etc, ISI marked with mild steel/pressed steel sunken box thickness as per IS standard (with earth dolly) duly painted with two coats of anti corrosive paint/aluminium paint over a coat of red oxide primer internally and two coats of black bituminous paint over a coat of red oxide primer externally, covered with 3 mm thick plastic laminated sheet cover for fixing of switches, socket and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1. 5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one light or fan point, controlled by one, one way switch 5 Amps. |
| 5 | All as per srl item No 04 above but for one bell/buzzer point controlled by one push botton. |
| 6 | All as per srl item No 04 above but for one socket out let 3 pin 5 Amps on the same board. |
| 7 | All as per srl item No 04 above but for one light point controlled by two, 2 way switches. |
| 8 | All as per srl item No 04 above but for one socket outlet of 3 pin 5 Amp on independent board. |
| 9 | All as per srl item No 04 above but for one socket outlet of 15 Amps fixed on independent board with 4. 0 sqmm multistranded copper conductor wire FRLS PVC insulated and 4. 0 sqmm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified and directed. |
| 10 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green for single phase circuits) , with multistranded copper conductor 1. 5 sqmm nominal cross-sectional area, single core, PVC insulated and unsheathed FRLS cable 1100 Volts grade, ISI-694 marked with valid CML No. and existing/new PVC concealed conduit of 20 mm bore with accessories in wall floor etc with 3 mm thick plastic laminated sheet cover for fixing of switches, sockets and fan regulators etc, inciuding PVC insulated multistranded copper conductor 1. 5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for one light or fan point, controlled by one, one way switch 5 Amps. |
| 11 | All as per srl item No 10 above but for one bell/buzzer point controlled by one push botton. |
| 12 | All as per srl item No 10 above but for one socket out let 3 pin 5 Amps on the same board. |
| 13 | All as per srl item No 10 above but for one socket outlet of 3 pin 5 Amp on independent board. |
| 14 | All as per srl item No 10 above but for one socket outlet of 15 Amps fixed on independent board with 4. 0 sqmm multistranded copper conductor wire FRLS PVC insulated and 4. 0 sqmm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified and directed. |
| 15 | S&F of switch piano, flush type, 5 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and directed. |
| 16 | S&F of switch piano, flush type, 15 amps, 230 volts, single pole, one way (ISI marked) complete all as specified and directed. |
| 17 | S&F of switch piano, flush type, 5 amps, 230 volts, single pole, two way (ISI marked) complete all as specified and directed. |
| 18 | S&F of sockets outlet multipurpose 2 in 1, 5 Amps flush type confirming to IS complete all as specified and directed. |
| 19 | S&F of sockets outlet multipurpose 2 in 1 pin, 5 and 15 Amps flush type confirming to IS complete all as specified and directed. |
| 20 | S&F of ceiling rose, PVC of size 65 mm x 18 mm two to three terminals (ISI marked) complete all as specified and directed. |
| 21 | S&F of bell push flush type 5 Amps complete all as specified and directed. |
| 22 | S&F of stepped type, electronic fan regulator on the existing phenolic laminated sheet etc as required complete all as specified and directed. |
| 23 | M&L point wiring using approved colour coding as per IS (Red, Black and Green) for single phase circuits) , with multi-stranded copper conductor 1.5 sqmm nominal cross -sectional area, single core, PVC insulated and unsheated FRLS cable 1100 volts grade, ISI 694 marked with valid CML No. and existing/new PVC concealed conduit of 20 mm bore including medium grade, PVC concealed conduit MMS, ISI marked of dia not less than 20 mm and conduit accessories conceled in wall/roof/floor etc, ISI marked with valid CML No. (IS-9537 - 1983 for condits and IS : 3419 - 1976 for conduit accessories) with terminated to new pressed flush metal boxes readily available cover with outer plates inner plates et, suitable for mounting modular type switches, socket fan regulator etc PVC insulated multistanded copper conductor 1.5 sqmm nominal cross sectional area single core FRLS cable as earth continuity conductor to common earth and connecting to earth dolly complete all as specified and directed for the following :-Note : Modular switch and socket shall be measured and paid separately. |
| 24 | All as per srl item No 23 above but for one bell/buzzer point controlled by one push botton. |
| 25 | All as per srl item No 23 above but for one light point controlled by two, 2 way switches. |
| 26 | All as per srl item No 23 above but for one socket out let 3 pin 5 Amps on the same board. |
| 27 | All as per srl item No 23 above but for one socket outlet of 3 pin 5 Amp on independent board. |
| 28 | All as per srl item No 23 above but for one socket outlet of 15 Amps fixed on independent board with 4.0 sqmm multistranded copper conductor wire FRLS PVC insulated and 4.0 sqmm multistranded copper conductor wire FRLS PVC insulated as earth wire complete all as specified and directed. |
| 29 | S&F in repair of switch modular 06 Amp 01 module, one way as per existing pattern complete all as specified and directed. |
| 30 | S&F in repair of of modular socket outlet, multi purpose, 06 Amps 3 pin combined 2 module as per existing pattern complete all as specified and directed. |
| 31 | S&F in repair of modular bell push 06 Amps 1 module as per existing pattern complete all as specified and directed. |
| 32 | S&F in repair of modular socket 16 Amps, 5 pin combined 2 module as per existing pattern complete all as specified and directed. |
| 33 | S&F ir repair of modular switch 16 Amps one way 1 module as per existing pattern complete all as specified and directed. |
| 34 | S&F in repair of switch modular 06 Amps two way, 1 module as per existing pattern complete all as specified and directed. |
| 35 | S&F in repair of modular fan regulator 5 step type, 2 module as per existing pattern complete all as specified and directed. |
| 36 | M&L in repair of lamp holder, PVC/ polycarbonate type with back plate suitable for batten fittings including taking down unserviceable lamp holder of any description complete all as specified and directed. |
| 37 | S&F in repair of bell AC single pole ding dong type 230 volt complete all as specified and directed. |
| 38 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 sqmm (FRLS) in and including PVC casing & capping non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 sqmm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed. (NOTE: Two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable and one run of PVC casing & capping shall be paid as one unit length.) |
| 39 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 6.0 sqmm (FRLS) in existing concealed /surface conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 6.0 sqmm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed.(NOTE: Two runs of 6.0 sqmm cable & one run of 6.0 sqmm cable shall be paid as one unit length.) |
| 40 | M&L for submain wiring with approved colour code/as per IS (Red, black & green for single phase) circuit with two single core PVC insulated cable with multistranded copper coductor of nominal cross sectional area of 10.0 sqmm (FRLS) including PVC conduit non metallic including one run of PVC insulated multistranded copper conductor nominal cross section area of 10.0 sqmm (FRLS) of continuous earth wire green in colour including taking down old u/s sub-main wiring complete all as specified and directed. (NOTE: Two runs of 10.0 sqmm cable & one run of 10.0 sqmm cable and one run of PVC casing & capping shall be paid as one unit length.) |
| 41 | Supply and fixing in repair LED box type integrated batten wattage 20 watt having aluminum extruded housing in white powder coated finish with high translucent PC cover, dimension of the fixture must not be less then Length 1170 MM (± 5 MM) , Elegant Design, IP 20 Protection, minimum lumens output of the fitting shall be 2500 lumens with efficacy of 125 lm/W, CCT 5700 – 6500K, surge protector 4 KV, PF>= 0.95 with necessary mounting arrangements. The Manufacturer of the fixture shall have in house NABL Accredited Lab and must produce certificate of the same along with LM-79/LM-80/Test Report. |
| 42 | S&F in repair LED tube light fitting 10 Watt, 2 Feet or 591 MM in length, IP 20 Protection, wall mounted type, Slim LED batten with extruded aluminium housing and polycarbonate diffuser, elegant design with end caps, having excellent thermally managed polycarbonate extrution, LM 80 Certified LED having integral Electronic Constant Current Driver, IP 20 Protection, Opreating voltage 240 V, 50Hz AC Supply and Operating tempraeture 0 to 50 C, Power factor ≥ 0.9, Lumen output ≥ 1000, necessary mounting arrangements on PVC Square box 2 Nos, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed. |
| 43 | Supply and fixing in repair recessed/ceiling mounted down lighter with CRCA housing with high bright LED, idealy suited for low ceiling areas Brilliance 36watt LED, size 2ft x 2ft The product features color tuning from CCT 3000K – 6000 k, Surge Protector 4 KV, PF>= 0.95, necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting with white color flexible pipe complete all as specified and directed. |
| 44 | Supply and fixing in repair LED building security light fitting 35 Watt (or above) 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with electronic driver including thermal management in multiple optics complete with IP 65/66 protection complete with pre wired and necessary mounting arrangements, provision of new 3 core multistranded copper conductor of size 23/0.193 from ceiling rose to fitting complete all as specified and directed. |
| 45 | S&F integral decorative LED bollard with polycarbonate diffuser square shaped with IP 65 protection suitable for 10 watts LED & height of light 0.6 M, with necessary MS base box made out of MS sheet of 2 mm thick of suitable size abbended in PCC 1:2:4 base, elecrical connections with adequate size including removal of old unserviceable one complete as all specified and as directed. |
| 46 | S&F for LED post top lantern/gate light 40 watt light fitting made of die cast top housing must also be dia cast aluminium spigot housing with decarative acrylic diffuser with IP 65 protection complete with all accessories including removal of old unserviceable complete all as specified and directed. |
| 47 | S&F in repair of LED Bulb white E-27, 9 Watt of complete all as specified and directed. |
| 48 | S&F in repair decorative wall mounted luminaire made out of polycarbonate with unbreakable globe suitable for LED bulb and including of LED bulb 15 watts complete all as specified and directed. |
| 49 | S&F for sheet metal enclosure MCB DB TPN 4 way double door IP 43 with 200 Amps rated bus bar 415 volts double door with magnitic locking system complete all as specified and directed. |
| 50 | S&F for sheet metal enclosure MCB SPN DB 12 way with 200 Amps rated bus bar 240 volts double door IP43 with magnitic locking system complete all as specified and directed. |
| 51 | S&F for sheet metal enclosure MCB SPN DB 8 way with 200 Amps rated bus bar 240 volts double door IP 43 with magnitic locking system complete all as specified and directed. |
| 52 | S&F sheet metal and neutral enclosure single pole with two pin and earth plug and socket single pole MCB 20 Amps 240 volts fixed complete all as specified and directed. |
| 53 | S&F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 125 Amps with extended terminals complete all as specified and directed. Note:- suitable size and frame of MCCB required as per existing DBs complete all as specified and directed. |
| 54 | S&F MCCB 4P 415 volts 16 KA suitable for fixing on VTPN DB of capacity 100 Amps with extended terminals complete all as specified and directed. Note:- suitable size and frame of MCCB required as per existing DBs complete all as specified and directed. |
| 55 | Supply and fixing 415V 10KA \"C\" curve miniature circuit breaker (MCB) of tripple pole and neutral rated capacity TPN 63 Amps to 100 Amp current carrying capacity in the DB complete with connection testing and commissioning complete all as specified and directed. |
| 56 | Supply and fixing miniature circuit breaker (MCB) of single pole and neutral SPN 40 AMP to 63 AMP 240V, 10KA \"C\" curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 57 | Supply and fixing miniature circuit breaker (MCB) of single pole SP 10-32 AMP 240V, 10KA \"C\" curve in the MCB DB complete with connection testing and commissioning complete all as specified and directed. |
| 58 | Supply and laying in repair 1100 volts grade heavy duty service cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 6 sqmm 2 core including PVC conduit pipe nominal cross section in service connections complete all as specified and directed. |
| 59 | M&L in repair PVC casing & caping of any type, size by means of shadles, clamps screwes to existing wall/ceiling and making good in all respect incl wiring inside all complete all as specified and directed. |
| 60 | S&F in repair 2 modules white cover plate with frame inner and outer plates complete all as specified and directed. |
| 61 | All as per srl item No 60 above but 3 modules |
| 62 | All as per srl item No 60 above but 4 modules |
| 63 | All as per srl item No 60 above but 6 modules |
| 64 | All as per srl item No 60 above but 8 modules |
| 65 | All as per srl item No 60 above but 12 modules |
| 66 | S&F in repair 10\" x 12\" size plastic laminated bakelite sheet cover of hylem 2.8 mm thick including cutting holes for switches, sockets etc as pre requirement including fixing with brass machine screws and washer complete all as specified and directed. |
| 67 | All as per srl item No 66 above but 8\" x 10\" size |
| 68 | All as per srl item No 66 above but 8\" x 6\" size |
| 69 | All as per srl item No 66 above but 7\" x 4\" size |
| 70 | All as per srl item No 66 above but 4\" x 4\" size |
| 71 | Attending of internal electrical supply complain, no light complain, repair/maint and making the continuity of supply after rectifying the defects of the electrical items such as main DB\"s, switches, sockets, fan regulator, replacement of MCB (light/power) , lamp holders (bracket/ batten), bell/buzzer, push buton, ceiling rose, tube light fitting any type single pole/double pole, switch socket and plug combined, tube light fitting any type and other similar electrical items/fittings etc complete all as specified and directed. Note :- Contractor should complete the assigned job within 48 Hrs after receipt of the assignment. If the contractor fails to completed the assigned job in the given time recovery will be made @ Rs. 50.00 per job. In case of non reporting the recovery will be made on the basis of trademanship i.e Rs 300/- per day for electrician and Rs 200/- per day for helper. Providing of safty equipments to the electrician/labour will be sole responsibility of the contractor . The details of repair should be collected throughout the contract period from JE E/M at 0900 Hrs from office located at Mil station Area. Register of repair should be prepared by the contractor and details of repair should be updated in the register after completion of every repair work. Contractor will arrange vehicle, electrical tools, folding ladder, misc item like insulation tape, screws, nuts and bolts for repair work. |
| 72 | M&L for point wiring using approved colour coding as per IS (Red, Black and Green) suitable for flame proof (FLP) with 1.5 sqmm nominal cross sectional area, multi standerd flame retrdant low smoke (FRLS) insulated unsheathed copper conductor cable 1100V grade IS-694 marked TAC and FIA approved in and including surface mounted with saddles rual plug and fixing screws etc heavy duty electric resistance welded (ERW) stove enameld steel conducts ISI marked as per IS:9537 (Pt-1) 1980 of suitable size with all flame proof conduit accessories such as bends, elbows tees etc certified by CMRI dhanbad as suitable for flame proof areas and sealad with teflon tape on all conduits accessories and also sectional area multi stranderd flame retarant low smoke (FRLS) insulated, unsheathed copper conductor cable of size 1.5 sqmm 1100V grade IS-694 marked TAC and FIA approved as earth continiuty conductor connected to common earth complete all as specified and directed including taking down old wirings etc and deposited to MES store yard and as directed for the followings.(a) One light/ exhaust Fan point controlled by one MCB provided in main DB.Note:- Switch/MCB to be measured and paid for separetly. All points shall be provided in main DB installed inside/out side the building or complete all as specified and directed and directed at site. |
| 73 | S&F in replacement switch flame proof rotary type with termination box in LM6, 16A, single pole 250V complete all as specified and directed. |
| 74 | S&F in replacement switch flame proof rotary type with termination box in LM6, 16A, double pole 250V complete all as specified and directed. |
| 75 | S&F in replacement switch flame proof rotary type with termination box in LM6, 25A, double pole 250V complete all as specified and directed. |
| 76 | S&F in replacement flame proof switch socket & plug combined in LM6 cable termination box in LM6, 25A, 250V, 2P+ earth complete all as specified and directed. |
| 77 | Supply and fixing flame proof bulk head fittings with CMRI certified LED flame proof bulk head wellglass lumaniers of 30 Watts, diecast aluminium housing having safety class IP-65 with and including connections with suitable FRLS cable drawn through suitable size metalic conduits and hanging arrangements etc complete all as specified and directed. Make:- CG cat part No-IBFN100-30CDL or techno commercially equivalent model make of Wipro/Philips/Sudhir |
| 78 | Material and labour in repair for flame proof steel conduit and material and labour for cable drawn through flame proof conduits complete with 4.0 sqmm single core multistranded copper conductor 1100V grade IS-694 marked TAC and FIA approved in and including surface mounted with saddles rual plug and fixing screws etc heavy duty electric resistance welded (ERW) stove enameld steel conducts ISI marked as per IS:9537 (Pt-1) 1980 of suitable size with all flame proof conduit accessories such as bends, elbows tees etc certified by CMRI dhanbad as suitable for flame proof areas and sealad with teflon tape on all conduits accessories PVC insulated, and unsheathed cable 1100 volts grade on sunk cast iron terminal boxes with 4.0 sqmm single core multistranded copper conductor PVC insulated and unsheathed cable as earth continuity conductor to common earth and earth dolly with and including necessary connection to MCB/flame proof switch/flame proof light fittings/flame proof sockets etc complete all as specified and directed.Note:- 2 runs of 4.0 sqmm and 1 run of 4.0 sqmm cable and conduit shall be measured as 1 RM. |
| 79 | All as per srl item No 78 above but 2x2.5 sqmm + 1x2.5 sqmm earth wire. |
| 80 | M&L for taking down ceiling fan/Wall Mounting Fan, any size and sweep from its position and transport to workshop for servicing, dismantling for servicing including removal of bearing, bushes, condenser, connector, flexible cord, split pin etc if required removing old grease and refill fresh, lubricating bushes along with new washers, cleaning and washing fan blades, fan body etc with soap solution after repairing, re- assemble the same and transporting from workshop to any location in Jasai and fixing to position/location as directed, connecting to electric system, testing etc complete all as specified and directed . Note : -(i) Replacement of parts/rewinding shall be measured and paid separately (ii) Quoted rate is deemed to be inclusive of transporting fan from any location in Army Area to MES store & taking down unserviceable/ defective parts.(iii) Item such as bearings, gun metal bushes, capacitor, shaft etc required for replacement shall be measured and paid separately as supply only. |
| 81 | All as per srl item No 80 above but for exhaust fan of any size and make. |
| 82 | M&L for spray painting of ceiling fan, fan blades, down rod, canopy etc with a coat of Ist quality synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the fan numbers etc with black paint complete all as specified and directed. |
| 83 | Supply only of fan blades (set of three) of any make/type of ceiling fan of size 1200mm sweep complete all as specified and directed. |
| 84 | Supply only fan blades (set of three) of any make/type of ceiling fan of size 1400 mm sweep complete all as specified and directed . |
| 85 | Supply only U clamp complete with nut bolt washer, split pin and rubber weal etc complete all as specified and directed. |
| 86 | M&L for cutting and taking out old burnout winding of any sweep ceiling fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and directed . |
| 87 | M&L cutting and taking out old burnout winding of 230/250 mm sweep exhaust fan/wall fan and rewinding with same gauge of copper winding wire of superior quality including insulation materials varnishing etc and testing complete all as specified and directed . |
| 88 | All as per srl item No 87 above but for 300 mm sweep . |
| 89 | All as per srl item No 87 above but for 380/450 mm sweep. |
| 90 | M&L for spray painting of exhaust fan of any size and make with a coat of Ist quality synthetic enamel paint of approved colour and quality including preparation of old painted surfaces, cleaning etc and printing the fan numbers etc with black paint complete all as specified and directed. |
| 91 | Supply only ball bearing suitable for ceiling fan/exhaust fan of any sweep complete all as specified and directed . |
| 92 | Supply only gun metal bush suitable for ceiling fan of any sweep complete all as specified and directed . |
| 93 | Supply only gun metal bush suitable for exhaust fan of any sweep complete all as specified and directed . |
| 94 | Supply only capacitor 2.5 MFD suitable for ceiling fan of any sweep complete all as specified and directed. |
| 95 | Supply only capacitor 4 MFD suitable for exhaust fan/wall mounting fan of any sweep complete all as specified and directed. |
| 96 | Supply only for replacement metallic bottom plate of ceiling fan of any sweep complete all as specified and directed. |
| 97 | S&F 250 mm sweep exhaust fan (plastic body) minimum three star rating with accessories complete all as specified and directed . |
| 98 | S&F 300 mm sweep exhaust fan metallic body minimum three star rating with accessories complete all as specified and directed . |
| 99 | M&L for dismantling and taking down carefully the existing unserviceable geysers of any storage capacity, any make, any model fixed in any position by disconnecting from electric connection and water inlet, out let connection and vent pipes etc from site (inside or outside bldgs) and transporting the same to MES E/M Office Jassai Store Yard for carrying out repair work such as over hauling/brazing welding etc and painting with one coat white colour synthetic enamel paint and re-fixing in same position including making good disturbed surface after complete repair work and reconnection of inlet, outlet pipe and vent pipe including testing complete all as specified and directed.Note : - (i) Replacement of parts shall be measured and paid separately(ii) Quoted rate is deemed to be inclusive of replacement of 4 Nos foundation bolts, nuts, washers of suitable size. |
| 100 | S&F in replacement of thermostat switch 240 volts AC suitable for geysers of any make/model and capacity (ISI Marked) complete all as specified and directed. |
| 101 | S&F in replacement of heating element of 1500 watt for geysers including nuts, bolts, gasket etc complete all as specified and directed. |
| 102 | S&F in replacement of bottom cover of 25 ltrs capacity geyser of any make/model duly painted to match with the existing surface complete all as specified and directed. |
| 103 | S&F in replacement of copper tank of 25 ltrs capacity geyser ISI marked manufactured out of cold rolled pressure electro type copper sheet of appropriate thickness double tapped brazing/welded internally copper tinned and hydraulically tested including nuts, bolts, washers, etc complete all as specified and directed. |
| 104 | S& F in replacement of brass chromium plated flexible connection pipe (length not less than 30 cm and not exceeding 50cm) with coupling nuts with washers suitable for 15 mm bore pipe complete all as specified and directed. |
| 105 | S&F in replacement of PVC (heavy duty) flexible pipe connection of 15 mm bore 450 mm long with two Nos brass coupling suitable for cold water complete all as specified and directed. |
| 106 | S&F in replacement of cable connection of geyser by PVC round insulated/sheathed copper cable of size 03 core 40/0076 and making necessary condition complete all as specified and directed. |
| 107 | S&F in replacement 3 pin plug top of capacity 15 Amp AC 240 Volts 50 Hz.complete all as specified and directed . |
| 108 | S&F in replacement sheet metal enclosures comprising two pin and earth plug socket, MCB SP 20 Amps (C-curve-10 KA) complete all as specified and directed. |
| 109 | S&F in replacement of 15mm bore brass non return valve (ISI Marked) vertical/Horizontal type and fixed to GI pipe fittings complete all as specified and directed. |
| 110 | S&F in replacement of GI tubing 15mm bore medium grade (ISI Marked) with all GI fitting and fixed complete to walls and ceiling or laid in floor for inlet and outlet water connection to existing O/H tank complete all as specified and directed. |
| 111 | S&F in replacement of GI tubing 20mm bore medium grade (ISI Marked) with all GI fitting and fixed complete to walls and ceiling or laid in floor for inlet and outlet water connection to existing O/H tank complete all as specified and directed. |
| 112 | S&F in replacement of Gun metal gate valve with iron wheel head, screwed both ends for iron pipe of size 15mm bore complete all as specified and directed. |
| 113 | Supplying and fixing in repair 1100 Volts grade heavy duty cable PVC insulated aluminium conductor cable solid stranded, served with inner sheathing of PVC tape and overall PVC sheathed in service connection twin core cable flat or circular in section of cross sectional area 6 sqmm 2 core complete all as specified and directed. |
| 114 | All as per srl item No 113 above but of size 10 sqmm 2 core. |
| 115 | M&L for excavation in trenches not exceeding 1.5m wide and not exceeding 1.5m in depth, for foundation, laying of cable etc.n exc 10 sqm on plan and getting out in soft/loose soil complete all as specified and directed. |
| 116 | M&L for returning, filling in, including spreading, levelling, watering and well ramming in layer not exceeding 25cm thick in any type of soil complete all as specified and directed . |
| 117 | M&L for removal of excavated soil to a distance 50 mtr and depositing where directed at a level not exceeding 1.5 mtr above the starting point complete all as specified and directed . |
| 118 | Supply and filling dry clean sand (tibba sand) in trenches for cushioning of underground cable and punning for cushioning to cable complete all as specified and directed .Note :- Punned thickness shall be measured for the purpose of payment. |
| 119 | M&L for 40 to 50mm thick rough dressed Jodhpur type stone slab cover 25 to 30 cm wide and not less than 60 cm in length, laid dry abuting each other with gap between adjacent slab not exceeding 10 mm over under ground cable protection complete all as specified and directed. |
| 120 | Supply and lay cable XLPE insulated screened PVC bedded, galvanised steel strip or wire armoured, electric power cables (heavy duty) 1100 volts grade with stranded aluminium conductor of size 10 sqmm 2 core including taking out old unserviceable cable complete all as specified and directed. |
| 121 | All as per srl item No 120 above but sec. area 25 sqmm 4 core. |
| 122 | All as per srl item No 120 above but sec. area 50 sqmm 3.5 core. |
| 123 | All as per srl item No 120 above but sec. area 70 sqmm 3.5 core. |
| 124 | M&L for earthing complete with galvanized steel earth plate electrode 60 cm x 60 cm x 6 mm thick buried directly in ground (earth pit not less than 2.25 metre deep below ground level) with top edge of plate not less than 1.5 metre below normal ground level connected to galvanized earth lead wire 4 mm dia by means of bolts, nuts, check nuts and washers of galvanized iron or steel all as shown in electrical Plate No 3 of MES SSR Part-I connected to main switch board or main control board complete all as specified and directed and testing on completion including provision of earth wire protected by galvanized iron 15 mm dia light grade pipe and watering pipe shall be 20 mm bore light grade including all excavation and earth work in any type of strata, PCC pit with pre-cast RCC cover, charcoal/salt, funnel etc complete all as specified and directed. NOTE :(i) The concrete pit shall be PCC 1:3:6 type C-1, 40 mm thick pre cast cover slab of RCC (1:2:4) type B-1 using 20mm graded stone aggregate reinforced with 8mm TMT bars @ 10 cm C/C on both sides with suitable cast iron handle shall be provided in lieu of cast iron cover shown in electrical plate No 3 of MES SSR Part-( ii) Item includes the cost of GI pipe up to 7.5m for protection of earth wire.(iii) Item includes cost of lead wire up to 7.5 m |
| 125 | M&L taking down/dismantling of U/S Air Termination any type complete all as specified and directed. |
| 126 | Supply and fixing Air termination single pointed copper rod 12 mm dia and 300 mm long complete all as specified and directed. |
| 127 | Supply and fixing Air termination single pointed aluminium rod 12 mm dia and 300 mm long complete all as specified and directed. |
| 128 | M&L for taking down/dismantling of U/S Test point terminal block complete all as specified and directed. |
| 129 | Supply and fixing test point terminal block made of gun metal or phosphorus bronze size 75x75x25mm drilled and screwed including 3 nos 8 mm dia 25 mm long hex head screw complete all as specified and directed. |
| 130 | M&L for taking down/removing of unserviceable strip any type complete all as specified and directed. |
| 131 | Supply and fixing Aluminium strip 25 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 132 | Supply and fixing Copper strip 20 x 3.15mm with saddles and fixing screws etc. for roof conductors and down conductors above ground complete all as specified and directed. |
| 133 | M&L for taking up/dismantling of U/S earthings any type complete all as specified and directed. |
| 134 | M&L for earthing complete using copper plate 60×60cm ×3.15mm thick electrode and 20x3 mm copper strip as earthing lead buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to 20x3 mm copper strip thick by means of bolt nuts check nuts and washers of copper complete all as specified and directed & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal, salt, funnel, complete all as specified and directed. |
| 135 | M&L for earth continuity conductor fixed to wall or recess or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc. as required 20x3mm copper strip complete all as specified and directed. |
| 136 | M&L for earthing complete with galvanised steel earth plate electrode 60 cm ×60 cm × 6mm thick and 32x6 mm GI strip as earthing lead buried directly in ground earth (earth pit not less 2.25 m deep below ground level) with top edge of the plate not less then 1.5 mtr below normal ground level connected to galvanised iron earthing strip 32mm x6mm thick by means of bolt nuts check nuts and washers of galvanized iron or steel complete all as specified and directed & shown in electrical plate No.3 of MES SSR part-I 2009 connected to earth test point as specified and testing on completion including provision of 40 mm dia light grade pipe up to 7.5 mtr length as protection & watering pipe shall be 20 mm bore medium grade including all excavation & earth work in any type of soil incl PCC pit (1:3:6) type C-1 with RCC cover including charcoal, salt, funnel complete all as specified and directed. |
| 137 | M&L for bore well earthing by drilling bore with bore machine for lightening protection system using GI pipe heavy duty 50 mm dia as earth electrode driven up to a depth of 50 meters below ground level, duly made holes at 20 cm intervals, along the length of GI pipe and providing the charcoal salt mixture incl GI pipe 150 mm dia light grade as protection upto a depth of 12 meters and GI strip of 32x6 mm so as to acheive desired earth results. Testing and commissioning complete. (earth strip of size 32x6mm upto a length of 7.5m is deemed to incl in this item rate) . |
| 138 | M&L for earth continuity conductor fixed to wall or recess or buried in ground or drawn in conduit/pipe or fixed to poles or any other indicated situation for loop earthing etc as required 32x6mm galvanised iron strip complete all as specified and directed. |
| 139 | M&L for taking up/dismantling of U/S earth continuity conductor any type complete all as specified and directed. |
| 140 | Material and labour for disconnection and testing for fault finding & connecting back after reparing/ servicing of earthing connection complete all as specified and directed.Note :- Spare parts required for replacement during reparing/ servicing shall be measured and paid separately as \"Supply & Fix\" |
| 141 | Material and labour for transportation & deposition to MES Yard of desert cooler any type for testing /fault finding and transporting back to site from MES Yard after repairing/servicing if necessary complete all as specified and directed.Note :- T&P/ vehicle required to carryout the repair work shall be arranged by contractor at their own cost & the cost deemed to be inclusive in the quoted rate. |
| 142 | Material and labour for rewinding desert cooler fan motor 3 speed, 1400 RPM of capacity 1/5 HP with super enameled copper wire of appropriate size including replacement of bush, shaft and capacitor 4 MFD, 240 volts complete all as specified and directed. |
| 143 | Material and labour for replacement of capacitor for fan motor of 4 MFD, 230/250 V suitable for desert cooler fan motor complete all as specified and directed. |
| 144 | Material and labour for any size patch repair work to unserviceable corroded portion of body of desert cooler with 18 to 24 gauge (as per existing sheet) PGI sheet including necessary welding and painting with two coat of synthetic enamel spray paint over one coat of red oxide primer (the new surfaces should specified & match with existing surface) including leakage testing complete all as specified and directed. |
| 145 | Material and labour for dis-connection, taking down, transportation & deposition of air curtain any type and size to MES Yard incluiding testing /fault finding at MES Yard and transporting, installing and connecting back to site from MES Yard after repairing/servicing, rewinding of air curtain fan motor with super enameled copper wire of appropriate size including replacement of bush, shaft and capacitor of suitable size, 240 volts complete all as specified and directed.Note :- T&P/ vehicle required to carryout the repair work shall be arranged by contractor at their own cost & the cost deemed to be inclusive in the quoted rate. |
| 146 | Material and labour for replacement of front grill cover (moveable part +fix part) of the desert cooler made out of 20 gauge PGI sheet complete (incl Name plate of front grill and refixing of Selector switch with knob, indicator etc.) suitable for any type of desert cooler complete all as specified and directed. |
| 147 | Material and labour for replacement of bottom water tank of desert cooler of any size fabricated out of 18 gauge PGI sheet incl nuts bolts and washers etc complete or complete all as specified and directed & directed. |
| 148 | Material and labour for replacement of side supporting columns to be fabricated out of 18 gauge PGI sheet of any size incl necessary nut, bolts etc complete all as specified & directed. |
| 149 | Material and labour for replacement of side cover with louvers of desert cooler of any size fabricated with thickness out of 0.8 mm PGI sheet incl nuts bolts and washers etc complete all as specified and directed & directed. |
| 150 | Material and labour for replacement of top head of desert cooler of any size fabricated with thickness out of 18 gauge PGI sheet incl nuts bolts and washers etc complete all as specified and directed. |
| 151 | Material and labour for preparation of old painted steel surfaces of desert cooler up to 5000 cfm and applying a coat of synthetic enamel spray paint & two coats of anti corrosive black paint inside the Body water tank & side grills etc and writing of MES/SM No using synthetic enamel paint etc complete all as specified and directed. |
| 152 | S&F in replacement desert cooler fan motor capacity 1/7 HP three speed comprising of copper wound coils with 1400 RPM single phase with mounting ring and other connected items complete all as specified and directed. Make: Crompton/Havells/Khaitan/Bajaj. |
| 153 | S&F in replacement submersible pump 18 watt of discharge 6 LPM at head 2.5 Mtr 220-240 Volts AC, Supply, single phase, etc complete all as specified and directed. Make: Crompton/Havells/Khaitan/Bajaj. |
| 154 | S&F in replacement Wood/wool chips pad for desert cooler of suitable size (set of three pads) superior quality complete all as specified and directed. |
| 155 | S&F in replacement supporting jali of wood/wool chips pad set (set of three) made out of hard MS wire and fitted in side louvers complete all as specified and directed. |
| 156 | S&F in replacement selector switch with knob three speed suitable for fan motor complete all as specified and directed. |
| 157 | S&F in replacement PVC water distributor of 3 outlets with MS nuts & bolts complete all as specified and directed. |
| 158 | S&F in replacement PVC elbow suitable spliter for desert cooler complete all as specified and directed. |
| 159 | Material and labour for replacement of desert cooler fan blade assembly comprising of four blades of sweep 400mm made out of heavy duty PVC with bracings screw for desert cooler heavy duty etc complete all as specified and directed. |
| 160 | S&F in replacement PVC pipe 15 mm dia heavy duty for desert cooler pump complete all as specified and directed. |
| 161 | S&F in replacement 3 pin plug top of capacity 5 Amp AC 240 Volts 50 Hz complete all as specified and directed. |
| 162 | S&F in replacement motor fixing ring, clamps, four brackets with rubber pad and eight screw (clip type) for desert cooler complete all as specified and directed. |
| 163 | Supply and fix in repair ceiling fans complete with blades, down rods and accessories, 230 V, 1200 mm sweep. min air delivery 210 CFM with service value 6.00 BEE five star rated with brushless direct current motor (BLDC) including connecting to electric point system, testing etc complete all as specified and directed. Make: Crompton/Havells/Usha. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy