| 1 | Laying of one number PVC insulated PVC sheathed XLPE power cable of 1.1 kV grade of following size direct in ground including excavation, sand cushoning, protective covering and refilling the trench as required. |
| 2 | Up to 35 Sq mm |
| 3 | Above 35 sq mm up to 95 sq mm |
| 4 | Above 95 sq mm up to 185 sq mm |
| 5 | Above 185 sq mm up to 400 sq mm |
| 6 | Laying of one number additional PVC insulated PVC sheathed XLPE power cable of 1.1 kV grade of following size direct in ground in the same trench in one tier horrizontal formation including excavation, sand cushoning, protective covering and refilling the trench as required. |
| 7 | Up to 35 Sq mm |
| 8 | Above 35 sq mm up to 95 sq mm |
| 9 | Above 95 sq mm up to 185 sq mm |
| 10 | Above 185 sq mm up to 400 sq mm |
| 11 | Laying of one number PVC insulated PVC sheathed XLPE power cable of 1.1 kV grade of following size in existing RCC/HUME /METAL pipe as required. |
| 12 | Up to 35 Sq mm |
| 13 | Above 35 sq mm up to 95 sq mm |
| 14 | Above 95 sq mm up to 185 sq mm |
| 15 | Above 185 sq mm up to 400 sq mm |
| 16 | Laying of one number PVC insulated PVC sheathed XLPE power cable of 1.1 kV grade of following size on wall surface as required. |
| 17 | Up to 35 Sq mm (Clamped with 1 mm thick saddle) |
| 18 | Above 35 sq. mm and upto 95 sq. mm (clamped with 25x3mm MS flat clamp) |
| 19 | Above 95 sq. mm and upto 185 sq. mm (clamped with 25/40x3mm MS flat clamp) |
| 20 | Above 185 sq. mm and upto 400 sq. mm (clamped with 40x3mm MS flat clamp) |
| 21 | Supplying and making cable route marker with cement concrete 1:2:4 (1 cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size ) of size 60 cm X 60 cm at the bottom and 50 cm X 50 cm at the top with a thickness of 10cm including inscription duly engraved as required. |
| 22 | Supplying and fixing cable route marker with 10 cm X 10 cm X 5 mm thick G.I. plate with inscription there on, bolted /welded to 35 mm X 35 mm X 6 mm angle iron, 60 cm long and fixing the same in ground as required. |
| 23 | Supplying and making end termination with brass compression gland and aluminium lugs for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 24 | 2 X 10 sq. mm (19mm) |
| 25 | 2 X 16 sq. mm (22mm) |
| 26 | 3½ X 70 sq. mm (38mm) |
| 27 | 3½ X 95 sq. mm (45mm) |
| 28 | 3½ X 120 sq. mm (45mm) |
| 29 | 3½ X 150 sq. mm (50mm) |
| 30 | 3½ X 185 sq. mm (57mm) |
| 31 | 3½ X 240 sq. mm (62mm) |
| 32 | 3½ X 300 sq. mm (70mm) |
| 33 | 3½ X 400 sq. mm (82mm) |
| 34 | 4 X 10 sq. mm (25mm) |
| 35 | 4 X 16 sq. mm (28mm) |
| 36 | 4 X 25 sq. mm (28mm) |
| 37 | 4 X 35 sq. mm (32mm) |
| 38 | 4 X 50 sq. mm (35mm) |
| 39 | Supplying and making straight through joint with heat shrinkable kit including ferrules and other jointing materials for following size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 40 | 2 X 16 sq. mm |
| 41 | 2 X 25 sq. mm |
| 42 | 3½ X 70 sq. mm |
| 43 | 3½ X 95 sq. mm |
| 44 | 3½ X 120 sq. mm |
| 45 | 3½ X 150 sq. mm |
| 46 | 3½ X 185 sq. mm |
| 47 | 3½ X 240 sq. mm |
| 48 | 3½ X 300 sq. mm |
| 49 | 3½ X 400 sq. mm |
| 50 | 4 X 16 sq. mm |
| 51 | 4 X 25 sq. mm |
| 52 | 4 X 35 sq. mm |
| 53 | 4 X 50 sq. mm |
| 54 | Supply installation, testing and commissioning of Following Panels, fabricated out of 14/16 Gauge CRCA sheet steel in cubicle compartmentised modular construction complete with supporting rigid structure, interconnections, aluminium bus bar strip with heat strinkable colour coded current density of bus bar0.8 A per sqmm. Degree of protection IP 65, earthing hinged doors with 2.5 sqmm tinned braded copper wire, free standing floor mounted/wall mounted with removable Gland Plates on top & bottom of the panel, all mounting plates shall be GI sheets. Panels shall be treated with all anticorrosive process before powder coating as per specifications and final approved shade. Galvanised hardwares with zinc passivation shall be used in fabrication of panels 2 Nos. earthing terminals shall be provided for all distribution panels. Panels shall be suitable for 415 V, 3 Phase, 4 Wire, 50Hz supply system. |
| 55 | 100 amps |
| 56 | 200 amps |
| 57 | 400 amps |
| 58 | Proving, laying and fixing following dia GI Pipe (medium class) in ground / structure complete with GI fittings including punching / trenching (75 cm deep) or errection and re-filling etc as required |
| 59 | 100 mm dia. G.I. pipe (medium class) |
| 60 | 150 mm dia. G.I. pipe (medium class) |
| 61 | Supply of Midium class GI pipe |
| 62 | 100 mm dia |
| 63 | 150 mm dia |
| 64 | Supply & installation of PVCJunction of following sizes (inner dimension in mm) along with the fixing clamp & nut bolts suitable for different dia polesto be fixed on street/outdoor light poles. |
| 65 | 195x135x90 |
| 66 | 295x195x100 |