Tender For S/R To E.I In The New Circuit House At Hazaribagh.; 1 Wiring for light point , fan point , exahust fan point , call bell point with 1.5 sq mm FR PVC insulated copper conductor single core cable in surface / recessed PVC conduit with modular switch, cover plate, suitable size G.I / PVC box etc as reqd . 2 a) Group - B 3 wiring for light / power plug with 2x4.0 sq mm FR PVC insulated copper conductor single core cable in surface /recessed PVC conduit along with 1 Nos. 4 sq mm FR PVC insulated copper conductor single core cable for loop earthing etc as reqd . (39 no. power point & 10no. A/C point.) 4 Wiring for circuit submain wiring along with earth wire with the following size PVC insulated copper conductor , single core cable in surface / recessedPVC conduit etc as reqd . 5 a) 2x2.5 sq mm + 1x2.5 sq mm Earth wire ( For light circuit ) 6 b) 2x2.5 sq mm + 1x2.5 sq mm Earth wire ( For computer board wiring ) 7 c) 4x10 sq mm + 2x6.0 sq mm Earth wire (Ground floor to 1st floorForAC & Power) 8 d) 4x6.0 sq mm + 2x6.0 sq mm Earth wire (Ground floor to 1st floorForPower ) 9 e) 2x4.0 sq mm + 1x4.0 sq mm Earth wire ( submainForLight ) 10 f) 2x6.0 sq mm + 1x6.0 sq mm Earth wire ( submainFor Power ) 11 g)1x1.5.0 sq mm ( For inverter wiring ) 12 Supplying and fixing suitable size G.I / PVC box with modular plate and cover in front on surface /recess, including providing and fixing 3 pin , 5/6 Amps modular socket outlet and 5/6 Amps modularswitch connection , painting etc as reqd . 13 Supplying and fixing suitable size G.I / PVC box with modular plate and cover in front on surface /recess, including providing and fixing 6 pin , 15/16 Amps modular socket outlet and 15/16 Amps modularswitch connection , painting etc as reqd . 14 S/Fa compact unit made of 8x10 G.I./PVC box with phenolic laminated sheet cover in front of fixed with 3 nos of 5/6 amps piano type switch and socket , and one nos of 15/16 amp Piano type switch and socket well connected with suitable wire , earthing etc . as reqd. name as computer board. 15 a) 12 module box with cover plate = 1 No. @341.00 16 b) 5/6 amps, one way switch 3 No. @ 67.00 = 201.00 17 c) 5/6 amp, Socket 3 Nos. @ 88.00 = 264.00 18 d) 15/16 amp switch 1 No. @ 102.00 19 e) 15/16 amp socket 1 No. @ 145.00 20 Total = 1053.00 21 Supplying and fixing 20 Amps , 240 volts , SPN industrialtype , socket outlet, with 2 pole and earth, metal enclosed plug top along with 20 Amps C series , SP MCB in sheet steel enclosure on surface or in recess with chained metal cover for the socket outlet and complete with connections, testing and commissioning etc. as required . 22 S/F Following way single pole neutral , sheet , MCB Distribution board 240 volts , on surface / recess , complete with tinned copper busbar , neutral busbar , earth bar , din bar , detachable gland plate , interconnections , phosphatized and powder painted including earthing etc as reqd . ( but without MCB/RCCB/Isolator ) 23 a) 4 way, Double door 24 b) 6 way, Double door 25 Supplying and fixing following way, horizontal type three pole and neutral, sheet steel, MCB distribution board, 415 volts, on surface/ recess, complete with tinned copper bus bar, neutral bus bar, earth bar, din bar, interconnections, powder painted including earthing etc. as required. (But without MCB/RCCB/Isolator) 26 4 way (4 + 12), Double door, Horizontal type 27 S/F 6 to 32 Amps rating , 240 volts , B series , miniature circuit breaker suitable for lighting and other loads of following pole in the existing MCB DB complete with connections , testing and commissioning etc, as reqd . 28 Supplying and fixing 6 amps to 32 amps rating, 240 volts, 10 kA, “C” curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, esting and commissioning etc. as required. 29 50/63 amps, TPN 30 Supplying and fixing following rating, double pole, (single phase and neutral), 240 volts, residual current circuit breaker (RCCB), having a sensitivity current 30 milli amperes in the existing MCB DB complete with connections, testing and commissioning etc. as required. 31 a) 40 Amps double pole Isolator (For light DB and security light) 32 b) 63 Amp double pole Isolator (For power and AC) 33 S/F 2 pin 5 Amp . Ceiling rose on the existing junction box etc as reqd . 34 Supplying and fixing batten/ angle holder including connections etc as reqd . 35 S/F Following Modularswitch / socket on the existing switch box / cover including connections etc as reqd . 36 a) Electronic step fan regulator Modular 37 S.I.T.C of floowing rating surface mounted LED tube light fittingsuitable for 230V 50Hz, single phase supply etc. complete as required. 38 a) 20/22W LED Tube light 39 Supplying and fixing LED bulb 9/10w 40 S/F 12 (300 mm) Exhaust Fan 41 S/F 16 (400 mm) wall mounted fan 42 Supplying and laying of XLPE insulated PVC sheathed aluminium armoured cable working voltage upto 1100 volts as per IS: 7098 (Part I) of following size 43 a) 2 core 6 sq mm ( For security light on the roof) 44 b) 2 core 10 sq mm ( For Old Circuit house to 2 nos. founten) 45 c) 95 sq, mm. 3.5 core (for S/C) 46 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size exceeding 35 sq mm but not exceeding 95 sq mm direct in ground including excavation, and refilling the tranch etc as reqd. But excluding sand cushioning and protective covering. 47 Laying and fixing of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size on wall surface as required.UP to 35 sq. mm to (clamped with 1 mm thik saddle) 48 Laying of one number PVC insulated and PVC sheathed/ XLPE power cable of 1.1 KV grade of size not exceeding 35 sq mm directr in ground including excavation, and refilling the trench etc as rquired, but excluding sand cushioning and protective covering. 49 Earthing with copper earth plate 600mm x 600mm x 3mm thick including accessories, and providing masonry enclosure with cover plate having locking arrangement and watering pipe etc. (with charcoal or coke and salt) as required. 50 Supply and laying 8 SWG copper wire at 0.50 metre below ground level for conductor earth electrode, including soldingetc. as required. 51 6 sq mm. aluminium lugs 52 10 sq mm. aluminium lugs 53 95 sq mm. aluminium lugs 54 S.I.T.C of floowing rating LED Street lighting luminariewith pressure die cast housing and toughenedglass cover (IP 66 protection) in existing pole/pipe for supply voltage 100-270V AC, 50Hz. Luminarie shall be confirm to IS: 10322 part-5/section-3 and shall be complete with all neccssary accessories as required 55 a) 90w L.E.D. Campus light. 56 Supplying and fixing Cable junction Box without MCB (Make - Sintex/Hensel or equivelant. 57 Providing and fixing following capacity 2 pole/ 4 pole ON/OFF-load changeover switches with side handle operation, in sheet enclosure in existing metal board including drilling holes in metal board, making connection, earthing the body etc. as required. 58 320 amps, 4 pole