Tender For Construction Of Temporary Shed For Tools Of Hls Including Electrification At Nwtc Nal Belur Bengaluru
Tender Value
8.56 Lakhs
Estimated cost
Bid Submission
28 Oct 2024
0 days left
EMD
17500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online
Tender Overview
Organization
Tender ID
Competition Type
NCB
Bidding Type
Tender
Location / State
belur → Karnataka
EMD Exemption
Available
Quantity
Not Available
Website
Contact Person
Address
Project Description
Construction Of Temporary Shed For Tools Of Hls Including Electrification At Nwtc Nal Belur Bengaluru
BOQ
| Sl. No. | Item Description |
| 1 | EARTH WORK |
| 2 | Earth work in excavation by mechanical means (Hydraulic excavator) / manual means in foundation trenches or drains (not exceeding 1.5 m in width or 10 sqm on plan), including dressing of sides and ramming of bottoms, for all lift, including getting out the excavated soil and disposal of surplus excavated soil as directed, within a lead of 50 m.All kinds of soil. |
| 3 | CEMENT CONCRETE (CAST IN SITU) |
| 4 | Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth1:2:4 (1cement : 2 coarse sand (zone-Ill) derived from natural sources : 4 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 5 | Providing and laying in position excluding cement concrete of level: specified grade the cost of centering and shuttering - All work up to plinth 1:5:10 (1 cement : 5 coarse sand (zone-Ill) derived from naturalsources :10gradedstoneaggregate40mm nominal size derived from natural sources) |
| 6 | REINFORCED CEMENT CONCRETE |
| 7 | Reinforced cement concrete work in walls (any thickness),including attached pilasters, buttresses, plinth and string courses, fillets, columns, pillars, piers, abutments, posts and struts etc. above plinth level up to floor fivelevel,excludingcost of centering,shuttering, finishingand reinforcement:1:1.5:3 (1 cement : 1.5 coarse sand(zone-III) derived from natural sources : 3 graded stone aggregate 20 mm nominal size derived from natural sources) |
| 8 | Steelreinforcement forR.C.C.workincludingstraightening,cutting, bending, placing in position and binding all complete upto plinth level.Thermo-Mechanically Treatedbars of gradeFe-500D or more. |
| 9 | STEEL WORK |
| 10 | Structural steel work in single section, fixed with or without connecting plate, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 11 | Structural steel work riveted, bolted or welded in built up sections, trusses and framed work, including cutting, hoisting, fixing in position and applying a priming coat of approved steel primer all complete. |
| 12 | Steel work in built up tubular (round,square or rectangular hallow tubes etc) trusses etc.including cutting ,hosting,fixing in position and applying a priming coat of approved steel primer,including welding and bolted with special shaped washers etc,complete,hot finished welded type tubes |
| 13 | FLOORING |
| 14 | 52 mm thick cement concrete flooring with concrete hardener topping, under layer 40 mm thick cement concrete 1:2:4 (1cement : 2 coarse sand : 4 graded stone aggregate 20 mm nominal size) and top layer 12 mm thick cement hardener consisting of mix 1:2 (1 cement hardener mix : 2 graded stone aggregate 6 mm nominal size) by volume, hardening compound mixed @ 2 litre per 50 kg of cement or as per manufacturer\"s specifications. This includes cost of cement slurry, but excluding the cost of nosing of steps etc. complete. |
| 15 | ROOFING |
| 16 | Providing and fixing precoated galvalume profile sheets (size, shape andpitch of corrugation as approved by Engineer-in-Charge) of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05mm) with zinc coating 120 grams per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns. Sheet should have protective guard film of 25 microns minimum to avoid scratches during transportation and should be supplied in single length upto 12 metre or as desiredby Engineer-in-charge. The sheet shallbe fixed using self drilling /self tapping screws of size (5.5x 55 mm) with EPDM seal, complete upto any pitch in horizontal/ vertical or curved surfaces, excluding the cost of purlins, rafters and trusses and including cutting to size and shape wherever required. |
| 17 | Providing and fixing precoated galvalume sheet roofing accessories of total coated thickness 0.50 mm (base metal of minimum 0.45 mm thickness with total coating thickness of 0.05 mm) with Zinc coating 120 gram per sqm as per IS: 277, in 240 mpa steel grade, 5-7 microns epoxy primer on both side of the sheet and polyester top coat 15-18 microns using self drilling/ self tapping screws complete :Ridges plain (500- 600mm) |
| 18 | FINISHING |
| 19 | 15 mm cement plaster on the rough side of single or half brick wall of mix:1:4(1 cement: 4 fine sand) |
| 20 | Finishing walls with Acrylic Smooth exterior paint of required shade:New work (Two or more coat applied @ 1.67 ltr/10 sqm over and including priming coat of exterior primer applied @ 0.90 litre/10 sqm) |
| 21 | Painting with synthetic enamel paint of approved brand and manufacture to give an even shade :Two or more coats on new work |
| 22 | Removing dry or oil bound distemper, water proofing cement paint and the like by scrapping, sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 23 | MARKET RATE ITEMS |
| 24 | Providing Precast cement concrete solid block masonry including hoisting and setting in position with cement mortar 1:6 (1 cement : 6 Course sand) Completed as per the direction of Engineer in Charge as per the site condtion |
| 25 | Supplying and fixing 10 gauge weld mesh of size 25mm*25mm for guard bar. The weld mesh shall be fixed as per the direction of Engineer in charge as per site condition |
| 26 | Re- errecting Structural steel workat new location upto a lead of 500 m including all Gusset plates, bolts, nuts, cutting,rivets, welding etc. as per the Drawings and Directions of Engineer in charge. |
| 27 | ELECTRICAL WORKS |
| 28 | Laying of one no PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of Upto 35 sq. mm size in the existing RCC/ HUME/ HDPE/ Metal pipe as required. |
| 29 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of following size in the existing masonry open duct as required. |
| 30 | Laying of one number PVC insulated and PVC sheathed / XLPE power cable of 1.1 KV grade of Upto 35 sq. mm size direct in ground including excavation, sand cushioning, protective covering and refilling the trench etc as required. |
| 31 | Laying and fixing of one no PVC insulated and PVC sheathed/XLPE power cable of 1.1 KV grade of Upto 35 sq.mm (clamped with 1mm thick saddle) size on wall surface/metal truss as required. |
| 32 | Supplying and fixing of 4 way (4 + 12), Double door, surface/ recess mounting, vertical type, 415 V, TPN MCB distribution board of sheet steel, dust protected, duly powder painted, inclusive of 200 A tinned copper bus bar, common neutral link, earth bar, din bar for mounting MCBs (but without MCBs and incomer ) as required . (Note : Vertical type MCB TPDB is normally used where 3 phase outlets are required.) |
| 33 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Single pole |
| 34 | Supplying and fixing 5 A to 32 A rating, 240/415 V, 10 kA, \"C\" curve, miniature circuit breaker suitable for inductive load of following poles in the existing MCB DB complete with connections, testing and commissioning etc. as required. Triple pole |
| 35 | Supplying and fixing single pole blanking plate in the existing MCB DB complete etc. as required. |
| 36 | Supplying and fixing 20 A, 415 V, TPN Industrial type socket outlet, with 4 pole and earth, metal enclosed plug top alongwith 20 A \"C\" curve, TPMCB, in sheet steel enclosure, on surface or in recess, with chained metal cover for the socket out let and complete with connections, testing and commissioning etc. as required. |
| 37 | Supplying and fixing of 32 mm dia X 2.00 metres long G.I. pipe (medium class) bracket for mounting LED street light fitting on pole or MS Structure including bending the pipe to the required shape, 2 nos 40 mm X 3 mm flat iron clamps with nuts, bolts and washer, painting the flat iron with primer and finish paint etc. as required. |
| 38 | Supply, Installation, Testing and Commissioning of 1200 mm sweep,BEE 5 star rated, ceiling fan with Brush Less Direct Current (BLDC) Motor, class of insulation: B, 3 nos. blades, 90 cm long down rod, 2 nos. canopies, shackle kit, safety rope, copper winding, Power Factor not less than 0.9, Service Value (CMM/W) minimum 6.85, Air delivery minimum 215 CMM, 350 RPM (tolerance as per IS : 374-2019), THD less than 10%, suitable to operate with electronic regulator for speed control and all remaining accessories including safety pin, nut bolts, washers, temperature rise=75 degree C (max.), insulation resistance more than 2 mega ohm, suitable for 230 V, 50 Hz, single phase AC Supply, earthing etc. Complete as required. |
| 39 | Wiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in surface / recessed medium class PVC conduit, ceiling rose, with modular switch, modular plate, suitable GI box and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required.(group c) |
| 40 | Wiring for group controlled (looped) light point/fanpoint/exhaust fan point/call bell point ( without independent switch etc.) with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable in surface/ recessed PVCconduit, ceiling rose and earthing the point with 1.5 sq. mm FRLS PVC insulated copper conductor single core cable etc. as required.(Group-C) |
| 41 | Installation, Testing, Commissioning of wall bracket /ceiling/surface fittings(LED)/ Building Street Lights of all sizes and shapes containing upto two LED lamps per fitting, complete with all accessories including connections with 3C*1.5 sq.mm copper Flexible cable as etc. as required. |
| 42 | Supplying and fixing of 20mm sizeof medium class PVC conduit along with accessories in surface/recess including cutting the wall and making good the same in case of recessed conduit as required. |
| 43 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate as required. 15/16 A SP switch |
| 44 | Supplying and fixing following modular switch/ socket on the existing modular plate & switch box including connections but excluding modular plate as required. 6 pin 15/16A socket outlet |
| 45 | Supplying and fixing two module stepped type electronic fan regulator on the existing modular plate switch box including connections but excluding modular plate etc. as required. |
| 46 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 1 x 1.5 sq. mm |
| 47 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 1.5 sq. mm |
| 48 | Supplying and drawing following sizes of FRLS PVC insulated copper conductor, single core cable in the existing surface/ recessed steel/ PVC conduit as required. 2 x 2.5 sq. mm |
| 49 | Supplying and making end termination with brass ompression gland and aluminium lugs for 4 X 16 sq. mm (28mm) size of PVC insulated and PVC sheathed / XLPE aluminium conductor cable of 1.1 KV grade as required. |
| 50 | Supply of 4 Core 16 sqmm Aluminium conductor 1.1kV gradeXLPE insulated,PVC sheathed, armoured UG cable in one length as per IS : 7098 (Pt-1) 1988 |
| 51 | Supply of 30W, 240 V, colour temperature of 5700 degree kelvin to 6500 degree kelvin, outdoor type, (IP66) protection, street lightLEDfitting with minimum luminous efficiency of 100 Lm / watt, suitable driver with 10kV SPD inbuilt, in aluminum die–cast housing. |
| 52 | Supply of 36W to 40W,240 V, minimum colour temperaturemin. 5700 deg kelvinwith luminous efficiency of 100 lumen/watt, surface type4 feet length LED batten fitting complete set with suitable driver with inbuilt protection, rated for continuous operation, in powder coated extruded aluminium housing, protected from dust and insects as required. |
| 53 | Supply, installation, testing and commissioning of maintenace free earth pitof GIrod of 1000mm long (min) 20mm dia and suitable HDPE chamber with cover. To ensure the moisture content and electrical conductivity, resistance lowering grounding minerals shall be filled around the electrode of (min15 Kg). |
| 54 | Providing and fixing 10 SWG dia G.I. wire on surface or in recess for loop earthing as required |
| 55 | Cutting of cement concrete floor or road before trenching. |
| 56 | Supply, Installation and commisioning ofstreet light Controller with FRP Box 195mmX135mmX90mm size (nominal size) on surface with hinged door and 6mm SMC mounting sheet and analog daily time switch, 16A 8 way Bakelite connector, 6A SPN \"C\" curve MCB, having Auto and manual Functionsincluding connections as required. |
| 57 | Supplying and fixing of FRP Box 100mmX100mmX70mm size building light loop box (nominal size) on surface with hinged door and 10A 3 way bakelite connector to terminate building light cable etc as required. |
| 58 | Supplying and fixing 3 modular size PVC Modular Box with Plate on surface/ recess. |
| 59 | Supplying and fixing 4 pole, 25A, 30mA, 415V, RCBOin the existing MCB DB/ MCB Box complete with connections, testing and commissioning etc. as required. |
AI Tender Summary
Tender Timeline
Oct 21, 2024
11:30 IST
Tender Published
Tender notice published.
CompletedOct 28, 2024
17:00 IST
Bid Submission Deadline
Online submission via eProcurement portal.
CompletedOct 29, 2024
Bid Opening Date
Technical bids will be opened and evaluated.
CompletedTender Documents
Download All (ZIP) ↓
Disclaimer
We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender