Work Of Making Four 4 Ton Tower Ac For Hall At Vps Park Chowpatty. , Supply , Installation, Testing And Comissioning Of Air Cooled Floor Standing Tower Type Split Air Conditioners Complete With Indoor Unit(Idu), Out Door Unit (Odu), Surface / Concealed Copper Refrigerant Piping With Insulation (Closed Cell Elastomeric Nitrile Rubber Tubular Pipe Section) Upto 3 Mtr (Idu To Odu), Copper Power Cable Upto 3.5 Mtr (Idu To Odu), R-32/R-410 Green Refrigerant, Wireless Remote Control, Suitable For Working Between 415 V+/- 10% ,3 Phase 50 Hz Ac Supplywith Low & High Voltage Cutoff And Capable Of Performing Cooling, Dehumidification, Air Circulation Of Following Capacity With Scroll / Rotarycompressor. All As Per Pre Approved By Engineer In Charge.For Additional Technical Parameters Of Products/ Work, Refer Annexure A Attached With This Bsr .4.0 Tr , Providing & Fixing Of Is : 4985 - 2000 Class -4 (10 Kgf / Sqcm) Upvc Drainwater Piping With Fittings (Is:7834 & 10Kgf/Sqcm) Like Elbow, Socket,Tee, Solvent Cement Jointing, Support With Ms Hanger On Ceiling Orrecessed In Wall With Chasing & Plastering With 6 Mm Thick Closed Cellelastomeric Nitrile Rubber Insulation Including Leakage Testing Etc. Asrequired Of Following Nominal Sizes. All As Per Pre Approved By Engineerin Charge. For Additional Technical Parameters Of Products/ Work , Referannexure A Attached With This Bsr .25 Mm , Making Hole In Stone Masonary/ Rcc Wall/ Rcc Slab With Core Cutter Foraccomodating Refrigerant Pipe/ Drain Pipe/ Ms Pipe/ Cables Etc Offollowing Dia 100 Mm Dia Per Running Inch Lengthper , Supply & Fixing Ms Powder Coated Stand Suitable For 2.5/3.0/4.0 Troutdoor Type Of Split/Ductable/Tower Ac. All As Per Pre Approved Byengineer In Charge. For Additional Technical Parameters Of Products/Work , Refer Annexure A Attached With This Bsr . , Sitc Of Interconnecting Refrigerant Copper Pipe For Split/Ductable/Casseette Ac Of Dhe Grade C12200- Astm B68, B75, Chemicalcomposition Of Copper %- 99.0 Min And Phosphorus %- 0.015 To 0.040 .For Annealed Copper Tube :- Tensile Strength = 210 Mpa Wih Elongation% = 40 Min . Ink Mark Brand Printing On Hard Tubes Should Be Present.Piping Between Each Set Of Indoor & Outdoor Units Of Different Sizes Asper Oem Requirement & Specifications Including Class O Nitrile Rubbersleeves, Chase Cutting, Supports, Making Good The Same With Sandcement Plaster Etc. As Required. All As Per Pre Approved By Engineer Incharge. For Additional Technical Parameters Of Products/ Work , Referannexure A Attached With This Bsr . , Supply And Fixing Duct Insulation With 50 Mm Thick Expanded Polystyrene Thermocol (Esp) Sheet Of Density 24 Kg/Cu.M After Applyingtwo Coats Of Cold Setting Adhesive (Cprx Compound) And Binding Sheetwith Chicken Wire Mesh And Applying Cement Mortar Plaster (1:4)Including Primer & Painting (Suitable For Outdoor Aplication) Matchingwith Building Colour Or As Per Direction Of Engineer Incharge As Required.All As Per Pre Approved By Engineer In Charge. For Additional Technical Parameters Of Products/ Work , Refer Annexure A Attached With Thisbsr . , Providing & Fixing Of 240/415 V Ac Mcb With Positive Isolation Of 10Ka Breaking Capacity (B/ C/D Tripping Characteristic As Per Type Ofload And Site Requirement) 4 Kv Impulse Withstand Voltage, Isimarked Is 8828(1996) / Conforming To Iec 60898-1 2002, Iec 60947-2, Low Watt Losses, Trip Free Mechanisum , Energy Limiting Of Class 3As Per Iec, Minimum Phase Termination Capacity Of 35Sq.Mm. ,Conductor Line Load Reversibility , Ip 20 Contact Protection And Fittedin Existing Distribution Board/ Sheets, Minimum Electrical Operation20,000 Upto 20 A Rating And 10,000 Upto 63 A, 5000 For 80 A &Above Rating Including Making Connections, Testing Etc. As Required.Oem Shall Have Submit Nabl / Cpri / Erda Accrediated Lab Typetest Reports & All As Per Pre Approved By Engineer In Charge. Foradditional Technical Parameters Of Product / Work Refer Annexurea Attached With This Bsr. Four Pole Mcb (With B/C Curve Tripping Characteristics), 50/63 A Rating Each 1745 , Providing & Fixing Of Recessed/Surface Mounting Heavy Duty Vertical Tpn Distribution Board With Metal End Box With Provisionof Incomer Suitable For 3/4 Pole Mccb And Sp / Tp Mcb As Outgoing,Made Out From Galvanized Steel / Crca Sheet Not Less Then 1.2 Mmthick Conforming To Is-8623-1 & 3 / Iec 61439- 1 & 3. Powderpainted With Reversible Door (For Double Door Db Only ) Completewith Insulated 160 (Upto 160 A Incomer) / 250 Amp. Copper Busbar, Neutral Bars With Shrouds, Earth Bar , Color Codedinterconnecting Wire Set Of Suitable Rating And Din Bar,Maskingsheet, Making Internal Db Terminations With Copper Lugs, Ferrules,Detachable Gland Plate, Including Making Connections, Testing Etc.As Required. Oem Shall Have Submit Nabl / Cpri / Erdaaccrediated Lab Type Test Eports & All As Per Pre Approved Byengineer In Charge.For Additional Technical Parameters Of Product /Work Refer Annexure A Attached With This Bsr, Double Door Ip-43 & Ik-09 With Provision Of Incomer Mccb 100/ 125 A Rating With Metal End Box4 Way , Supplying And Drawing Fr Pvc Insulated & Unsheathed Flexible Copperconductor As Per Pwd Specification For Electrical Works With Isimarked (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade . Wire Shouldbe Made From 99.90 % Purity Copper, Class 5 Stranding In Acc. Tois:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Ofoxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existingsurface Or Recessed Pvc/ Ms Conduit/Casing Capping Makingconnections With Copper Lugs Of Suitable Size, Ferrules,Testing Etc. Asrequired. Oem Must Have Its Own In House Nabl Lab Setup For Alltesting Facilities For Wires. For Additional Technical Parameters Ofproduct / Work Refer Annexure A Attached With This Bsr, 4 X 6.0 Sq.Mm , Supply And Laying Pvc Insulated And Pvc Round Sheathed Multi Corecopper Conductor (Is:694) And As Per Is 8130 : 2013 Of 1.1 Kv Grade .Wire Should Be Made From 99.90 % Purity Copper, Stranding In Acc. Tois:8130/Iec 60228 For Lower Watt Loss , Oxygen Free For Less Chances Ofoxidization, Insulation Pvc Type A/C/D , Flame Retardant As Per Is10810-53, Better Amperage Rating As Per Is:3961 Part 5, In Existingpipe / Open Trench / Cable Tray / On Surface Including Makingconnection Etc. As Required. For Additional Technical Parameters Ofproduct / Work Refer Annexure A Attached With This Bsr, 4.0 Sq.Mm X 6 Core Rmtr. 455