Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45835124

Tender For Repair/Maint Of Lightening Conductors, Earthing And Allied Works At Happy Valley, Se Falls And Shillong Cantt Area And Repair / Maint Of Solar Water Heater , Swimming Pool , Laundary Plant And Other Misc Work Services At Happy Valley Area

Issued by Statutory Bodies & Commissions/Committees · shillong, Meghalaya
Tender Value
50 Lakhs
Estimated cost
Bid Submission
23 Nov 2024
0 days left
EMD
1 Lakhs
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
shillong → Meghalaya
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Repair/Maint Of Lightening Conductors, Earthing And Allied Works At Happy Valley, Se Falls And Shillong Cantt Area And Repair / Maint Of Solar Water Heater , Swimming Pool , Laundary Plant And Other Misc Work Services At Happy Valley Area Under Ge Sh

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 09-Nov-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-Nov-2024
2 13-Nov-2024 date corrigendum Date 23-Nov-2024

BOQ

Name of Work: REPAIR/MAINT OF LIGHTENING CONDUCTORS, EARTHING AND ALLIED WORKS AT HAPPY VALLEY, SE FALLS AND SHILLONG CANTT AREA AND REPAIR / MAINT OF SOLAR WATER HEATER , SWIMMING POOL , LAUNDARY PLANT AND OTHER MISC WORK SERVICES AT HAPPY VALLEY AREA UNDER GE SHILLONG
Sl. No. Item Description
1Material and labour,for testing and full servicing of Washing Machine front loading open pocket capacity 50kg with replacement of following spare part andwash room trolly sheet of size 1016x761x863 mm with roller and dry lines trolly size 930x630x80mm with roller. WashingMachine No 1, 2 & 3 including taking down old one complete including small spare part all as specified and directed.Make- BTC (NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
2Main Bearing Make-ZKL , SKF , TATA
3Counter Bearing Make -ZKL & SKF , TATA
4Control panel Make- L&T , MUKAND , BCH
5Temperature controller Make-INSTAMES
6Drain valve Make- SOCLA , AUDCO , KEYSTONE VALVE
7V-Belt Make-GIMPEX , ISCOKON , EMCON
8Material and labour for testing and full servicing of Drying tumblar front loading auto timed 50 kg andreplacement of following spare partDrying tumblar- 1 & 2. including taking down old one complete including small spare part all as specified and directed. Make- BTC(NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
9Steam Readiater Make- CUSTMIZED
10Main Bearing Make- ZKL , SKF , TATA 2
11Counter BearingMake- ZKL & SKF , TATA
12Temperature controller Make-INSTAMES
13Contractor Make- L&T & ELTEK , BCH
14Material and labour for testing and full servicing of Hydro extractor M/C top loading 25 Kg and replacement of following spare partDrying tumblar- 1 & 2, including taking down old one complete including small spare part all as specified and directed.Make- BTC(NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
15Rubber Buffer Bush Make- CUSTMIZED
16Control panel Make- L& T , MUKAND , BCH
17Timer Make- DEHL ,OZO , MINILEC
18Bearing set Make-ZKL & SKF , TATA
19ContractorMake- L & T , SKF , TATA
20Material and labour for testing and servicing of flat Work Ironer and replacement of following spare part, including taking down old one complete including small spare part all as specified and directed. (NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
21Pading + cloth Make- IMPORTED MAKE
22chest rabbing polish buffiing
23Material and labour for testing and servicing ofsteam heater for drying chamber including all necessary spare part / item size 29\" x 8.3\" x 18.5 : (SS Pipes ) including taking down old one complete including small spare part all as specified and directed.(NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
24Material and labour fortesting and servicing of full D-scaling (Chemical wash) of Boiler tube for Boiler No. 1 & 2 and replacement offollowing spare part Burner, Pump ,Inspection,Fire kit, Water Pump, Temperature Controller & indicator lamp etc. including small spare partor Boiler No. 1 & 2 with ( Note : After completion of work Calibration Certification for Boiler Nos. 1 & 2 should be produced to department) including taking down old one complete all as specified and directed.Make- M/s A S Thermofeed Pvt. Ltd(NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
25New Burner with photocell, transformer, ignition electrode. Make - ECO FLAME ,BLUE FLAME ,SUNMAX
26New coil including asbestor tape, rope, gasket and reactors along with new NRV, diffuser plate with pump. Make- KIRLOSKER , CROM
27Full set economizer. Make- BABA THRUM ,MEXOTHERM SUNMAX
28New fuel pump along with fuel hose, fuel pressure gauge, steam pressure guage and pressure switch. Make-KIRLOSKER ,CROMPTON ,EVEREST
29Electrical Control Panel Make- L &T , ELTEK , MUKAND 1
30Relay & Breaker, timer, burner sequence controller. Make- L&T,ELTEK , MUKAND 1
31Temperature Controller Make-ELTEK , MUKAND 1
32indicator lamp Make- L&T,ELTEK , MUKAND
33Material and labour for testing andfull servicing of Flat Bed Press automatic temp control -1 & 2 and replacement of following spare partFlat Bed Press- 1 & 2, including taking down old one complete including small spare partall as specified and directed. Make- BTC(NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
34Synchronous timer Make- L&T , ELTEK , BCH
35ContractorMake-L & T , ELTEK , BCH
36Cylinder Make-GANPATI , COSTMIZED
37Material and labour for testing and full servicingof AZR Compressor with 7.5 HP Motor , 10kg/cm2 and replacement of following spare partfor AZR Compressor-1 & 2, including taking down old one including small spare partcomplete all as specified and directed. Make- M/s Khosla(NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
38Piston Make-EVEREST ,POWER HOUSE
39Cylinder Make-EVEREST ,POWER HOUSE
40Material and labour for testing and full servicingofMS Steam pipe bounded mineral wool sanp on lagging with aluminum etc including taking down old one including small spare partcompleteall as specified and directed(NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
41Material and labour for testing and full servicingof Water softener plant (up flow) hydrion packed with all necessary spare part etc. including taking down old one including small spare part complete all as specified and directed(NOTE : All Work shall be done by OEM and produce fitness certificate of machine)
42Taking down carefully copper/aluminum point wiring light/fan/sockets out let/power point complete (fittings such as switches, sockets, ceiling rose, pendent holders, light fittings etc. are to be measured separately) and/or drawing out from existing conduit/batten and making good disturbed surface of walls/floors/ceiling, complete all as specified.
43Material and labour for Point wiring with 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductor drawn through and incuding medium grade, ISI marked, PVC conduit not less than 20 mm dia with accessories, concealed on wall/ceilingand incuding provision of 1.50 Sqmm single core PVC insulated , unsheathed cable FRLSH, 1100 volt grade with multi stranded copper conductorgreen colour as earth continuity conductor and connected to common earth dolly with suitable size of lugs, including mild steel sunken box/metal flush box with suitable modular or pressed steel terminal boxes made out of 1.6 mm thick mild steel sheet metal conforming to IS-5139(pt-I) of 1969 and IS:14772-2000 with earth dolly and coated with two coats of anti corrosive paint over a coat of red oxide primer bothinternally and externally including provision of new 3 mm thick plastic laminated sheet top cover for housing the switches , socket outlets, fan regulators etc. with brass screws and brass washersand making goodthe disturbed surfaces as per existingfor one light/fan/bell point controlled by one switch.
44Description all as per Srl item No.43 above here in before but for socket outletpoint 5 Amp on Independent board.
45Description all as per Srl item No 43 above here in before but for socket outlet point 5 Amp on same board.
46Description all as per serial item No 43 above but with 4 sqmm cablefor 3 pin 15 Amps switch socket outlet (Power point) complete all as specified.
47Material andlabour for point wiring with single core PVC insulated unsheathed cable of size 1.5 Sqmm nominal area with multi-stranded FRLSH copper conductor, 1100 Volt grade drawn through and including PVC non metallic surface casing capping of suitable size with all fitting and accessories including PVC modular board of suitable size for housing/mounting the modular switches/sockets, etc top covered with plastic laminated sheet 3mm thick including 1.5 Sqmm PVC insulated unsheathed single core FRLSH copper conductor earth continuity wire connected to common earth dolly completefor one light/fan point controlled by one way switch including making good disturbed surfaces complete all as specified and directed.
48Supply and fixing LED lights fitting 1x 20W, 220V,AC decorative box type, warm white / white type with driver, holder including LED tube light connecting up with three core flexible copper conductor cable of suitable size from ceiling rose completecomplete pre wired fixed to wallwith 2 nos PVC block of suitable size complete all spcifided and directed.
49S & F LED Luminaries 600mm x 600mm 36 watt, 220 V, AC recessed type with hifg efficiency PMMA diffuser soft galre free light complete with driver, holders and LED lamps suitable for roof ceiling including connecting up with 3 core flexible wire complete all as directed and specified.
50Supply and fixing round shape 12 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete
51Supply and fixing round shape 15 watt 220 volts AC recessed type with high efficiency PMMA diffuser soft glare free light complete with drivers, holders, LED lamp suitable for roof ceiling including connecting up with three core flexible copper conductor cable of suitable size complete
52Supply and fixing modular switch 1 way 6Awith cover plate and frame 230/250 volt , AC supply,ISI Marked, with white cover plate with frame complete all as specified and directed. Make:Cona , Plaza, Anchor, Vinay
53Supply and fixing modular switch 1 way 16Awith cover plate and frame230/250 volt , AC supply,ISI Marked, with white cover plate with frame complete all as specified and directed. Make:Cona , Plaza, Anchor .
54Supply and fixing modular switch 2 way 6A module 230/250 volt , AC supply,ISI Marked, with cover plate complete all as specified and directed.
55Supply and fixing modular bell push 1 way 6A module 230/250 volt , AC supply,ISI Marked, with cover platecomplete all as specified and directed.
56Supply and fixing call bell ding dong, AC, 230 V, Single pole ISI marked all as specified and directed. Make- Havells/anchor/ Legrand.
57Supply and fixing modular sockets with cover plate and frame 6A 2/3 pin combined 2 module 230/250 Volts,50 Hz , AC supply, ISI Marked, with cover platecomplete all as specified and directed.
58Supply and fixing modular sockets 6A/16A 2/3 pin combined 2 module with cover plate and frame 230/250 Volts,50 Hz , AC supply, ISI Marked, with white cover plate with frame complete all as specified and directed.
59Supply and fix MCB TPN, 240 Volts, 100Amps, 10 kA rupturing capacity415 Voltscomplete all as specified and directed including taking down old one all as specified and directed.
60Supply and fix MCB DP, 240 Volts, 40 Amps, 10 kA rupturing capacity \"C\" seriescomplete all as specified and directed
61Supply and fix in repair MCB Distribution board , 240 volts single pole andneutral ,double door, sheet steel, enclosure powder coated with 100 Amps rated busbar with neutral link, 12 ways , fixed on wall duly grouted in solid block wall or on wooden board with electrical connection, including taking downcomplete all as specified and directed.
62Supply and fix in repairs MCB DB 4 way vertical sheet metal enclosure TPN 415 volts, 50 Hz, with IP-43 protection, double door with200 Amps standard bus bar of suitable size and common neutral link all enclosed in standard sheet flush mounting complete all as specified.. (Note:MCB SP/TPN shall be measured and paid seperately under appropriate items of this schedule all as specified and directed .
63Material and Labour in repair of Air terimination,single pointed,Aluminium rod 12 mm dia and 300 mm long complete all as specified and directed by Engg-In-Charge.
64Material and Labour in repair of Air terimination,single pointed, copper rod 12 mm dia and 300 mm long complete all as specified and directed by Engg-In-Charge.
65Material and Labour in repair for test point teriminal block made of aluminium/gun metal or phosphorus bronze size 75 x 75 x 10 mm drilled and screwed including 3 nos. 8 mm dia 25 mm long hex,head screwe complete all as specified and directed by Engg-In-Charge.
66Material and Labour in repair of galvanised iron strip 32 x 6 mmwith porcelin insulator saddles and fixing screwes etc,for roof conductors and down conductors above ground complete burried in ground with fixing nuts and bolts,brazing etc, complete including taking down of old stripall as specified and directed by Engg-In-Charge.
67Supply and fixing ceiling rose surface bakelite 65x50mm, 3 terminal complete all as specified.
68M & L in repair Earthing complete with galvanised steel earth plate electrode 60×60cm.× 6mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to galvanised strip 32 x6mm by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including brazing workand 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed.
69M & L in repair Earthing complete with Copper plate electrode 60×60cm.× 3.15mm thick, buried directly in ground (earth pit not less than 2.25 metres deep below ground level) with top edge of the plate not less\"than 1.5 metres below normal ground level, connected to copper strip 20 x 3 mm earthing lead by means of bolts, nuts, check nuts and washers of galvanised iron or steel all as shown in electrical plate No. 3 connected to earthing test point all as specified or indicated including testing on completion including brazing workand 40mm dia light grade pipe for earth lead protection and testing on completion complete all as specified and directed.
70Material and Labour in repair of copper strip 20 x 3 mm with porcelin insulator saddles and fixing screwes etc,for roof conductors and down conductors above ground with fixing nuts and bolts,pvc junction, brazing etc complete including taking down of old strip all as specified and directed by Engr-in-Charge.
71S & F Exhaust fan 230 volts , 300mm,plastic body includingmaking all electric connection complete all as specified and as directed including cutting of hole on wall and makng good disturbed surface of wall and outer wooden box for fan fix on wall complete all as specified
72M&L for chemical pipe earthing electrode of size 3\" dia (80 mm dia 03 Nos) and 3 m long of M series model M-392 or T-393 of make Ashlok /JMV, consisting of inner GI pipe (master) protected with outer zinc coated pipe with high crystalline conductive mixtures (CM) having anti corrosive and conductive properiy. Sealed in between the two pipe including threading on both the ends inciuding back fill compound (BFC)3 bags filled surrounding the earth electrode according to manufactures instructions and all as specified and testing on completion including watering pipe 20 mm bore medium grade GI pipe, PCC 1:3:6 type C-1 using 20 mm graded stone aggregate pit with and including 40 mm thick precast RCC (1:2:4) type B1 cover of size 50 cm X 50 cm with 8 mm round bar @ 15 cm C/C both way all as per electrical plate No 2 of SSR part-1, funnel including main earth lead from earth electrode to test point up to 7.5 M Copper strip 32x6mm complete all as specified and directed.
73Material and Labour for removing the existingof GI/copper strip any size with porcelin insulator saddles and refixing the same with new porcelin insulators, fixing screwes PVC junction box etc,for roof conductors and down conductors above ground with fixing nuts and bolts,brazing etc complete all as specified and directed by Engr-in-Charge.
74Supply and fixMCB SP,6 to 32 Amps, \"C\" series 10kA, 240 Volts and to be housed in DBs including necessary connection complete all as specified and directedby Engr-in-Charge.
75Supply and fix in repairs MCB, single pole 240 volts 6 to 32 Amps capacity fixed in DB\"s.complete all as specified and directed
76Supply and fix MCB SPN 32 - 63 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessary connectionall as specified and directedby Engr-in-Charge.
77Supply and fix MCB TPN 63 Amps,\"C\" series 10kA, 240 Volts and to be housed in DBscomplete including necessary connectionall as specified and directedby Engr-in-Charge.
78Supply and fix Distribution board double door MCB TPN 4 way with IP 43 multiphase outgoing suitable for mounting 63 Amps MCB as incomer with Bus bars, Neutral links complete with all accessories including taking down old unserviceable one including MCBs complete all as directedby Engr-in-Charge.
79Supply and fixing submain wiring for DBs/ Power Point,two single core ,2.5 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts gradedrawing in and including suitable sizePVC casing caping (ISI marked) including 2.5 sqmm nominal cross sectional areamultistrandedcopper conductor FRLSH cable, PVC insulated unsheathed 1100 Volts grade earthwirecomplete all as specified.
80Material and labour for sub main wiring with two single core 4.0 sqmm FRLSH, ISI marked PVC insulated multi stranded, unsheathed copper conductor cable and one single core unsheathed FRLSH , ISI marked, PVC insulated multistranded copper conductor cable of size 4.0 sqmm green colour as earth lead including PVC casing capping of suitable size complete all as specified and directed, includingtaking down unservicable one.(Note: two run of 4.0 sqmm cable ,one runof earth wire of 4.0 sqmmand one run of PVC casing capping shall be measured as one length).
81M & L Sub main wiring with two run single core 6 Sqmm FRLSH copper conductor cable PVC insulated, unsheathed, 1100 V including 20 mm dia concealed on wall/ceiling in PVC conduit, medium gradeISI markedwith all accessories such as Tees, elbows, junction boxes etc, as required fixed on wall along with one run of6 Sqmm single core PVC FRLSH insulated unsheathed copper conductor cable as continuous earth wire and connecting to existing main switch board / distribution board and testing on completion including taking down old wiring etc complete all as directed. Note: (i) Two runs of 4 sqmm and one run of6 sqmm cable and one run of PVC conduitshall be measured as one RM. (ii)Cutting of chases in the wall of appropriate size shall be carried out with electric cutter machine . (iii) Necessary plastering in the disturbed surface of wall and distempering /white washing to match the existing colour shall be included in the unit rate quoted.
82Supply and installed in repairs of Galvanised, steel rod 16mm diameter and 2.5 metres lengthcomplete all as specified and directed by Engg-In-Charge.
83Supply and installed in repairs of Copper rod 12.5mm diameter and 2.5 metres lengthcomplete all as specified and directed by Engg-In-Charge.
84Material and labour for earthing complete with galvanised steel earth plate electrode 60 Cm X 60 Cm X 6 mm buried directly in ground vertically to a depth notless than 2.25 mtr deep below ground level with top edge of earth plate at a depth not less than 1.5 m below normal ground level connected to galvanised earth lead wire 4.0 mm dia by means of bolts, check nuts and washers ,galvanised steel and protected by GI pipe 15 mm bore light grade & connected to main switch board or main control board as directed and including concrete pit in PCC (1:3:6) type C1, precast RCC (1:2:4) type B1 cover slab 30 cm X 30 cmX 5 cm with 10mm dia TMT bars 8 cm C/c both ways andone handle for lifting made out of 8 mm dia TMTbar, funnel, wire mesh, 20mm bore galvanised iron pipe (medium grade) for watering, charcoal or coke and salt in alternative layers, necessary excavation and earth work in any type of soil and including necessary testing complete all as shown in Electrical Plate No 3 of SSR part -I.

AI Tender Summary

OUR REF NO 45835124
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 50 Lakhs
LAST DATE 23-11-2024
Authority
Authority Name Military Engineer Services
Work Description Repair/Maint Of Lightening Conductors, Earthing And Allied Works At Happy Valley, Se Falls And Shillong Cantt Area And Repair / Maint Of Solar Water Heater , Swimming Pool , Laundary Plant And Other Misc Work Services At Happy Valley Area Under Ge Sh
Basic Detail
Tender No GE/SHL/TOKEN-59 OF 2024-25
Bidding Type Tender
Location
City shillong
State Meghalaya
Key Dates
Publish Date 13 Nov 2024
Submission Date 23 Nov 2024
Open Date 25 Nov 2024
Finance
Tender Value 50 Lakhs
Tender Fee 500
EMD 1 Lakhs
Exemption Not Available
Document List
BOQ_761173.xls
d85b1170-d9ba-4156-95a5-be333f68f048.html
Tenderdocu59.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 13, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 16, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 23, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 23, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 25, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
xls

BOQ_761173.xls

html

d85b1170-d9ba-4156-95a5-be333f68f048.html

pdf

Tenderdocu59.pdf

pdf

Tendernotice_1.pdf