Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45835054

Tender For Misc E/M Maintenance Work At Aro Guntur Under Age (I) Suryalanka

Issued by Statutory Bodies & Commissions/Committees · suryalanka, Andhra Pradesh
Tender Value
7.13 Lakhs
Estimated cost
Bid Submission
16 Nov 2024
0 days left
EMD
14500
Bank guarantee accepted
Document Fee
500
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
suryalanka → Andhra Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Misc E/M Maintenance Work At Aro Guntur Under Age (I) Suryalanka

Corrigendum

Sr No Corrigendum Date Corrigendum Type New Submission Date
1 26-Oct-2024 CORRIGENDUM TO BOQ BOQ 09-Nov-2024
2 09-Nov-2024 Bid Auto Extn Corrigendum Bid Auto Extn Corrigendum 16-Nov-2024

BOQ

Name of Work: MISC E/M MAINTENANCE WORK AT ARO GUNTUR UNDER AGE (I) SURYALANKA
Sl. No. Item Description
1S&F in replacement Modular socket, 6A, 5 pin combination 2 module complete all as specified and as directed.
2S&F in replacement Modular switch socket combination , 16A, 6 pin 3 module complete all as specified and as directed.
3S&F in replacement modular switch one way 6 Amps, 1 module complete all as specified and as directed.
4S&F in replacement of modular Fan regulator electronic step type, 120W- 2 module, 240V single phase complete all as specified and as directed.
5S&F MCB Single Pole 6-32 Amps, 240V, C Curve, 10 kA, Complete all as specified and as directed.
6S&F Isolator 4 Pole 63 Amp, 415V Complete all as specified and as directed.
7S&F in replacement 4 Feet LED Tube light of 20Watt integrated Batten LED polycarbonate Tube light with inbuilt driver <10% THD with very high efficiency and connected upto ceiling rose including taking down existing Tube light fitting of any type complete all as specified and as directed.
8Taking down ceiling fan, cleaning internally & external and removing defective winding and rewinding with new super enamelled copper wire of existing gauge and weight as per manufactures design and instructions including insulating materials and varnishing of ceiling fans of of size 1200/ 1400mm sweap of any make and re-assembling testing complete and refixing to the location including replacement of flexible copper wire from ceiling rose to ceiling fan complete all as specified and as directed.
9Supply only condenser (capacitor) 3.15/ 2.5 MFD, 440 Volts, AC, 50 Hz as per IS : 1709 suitable for ceiling fan 1200/ 1400mm sweep complete all as specified and as directed.Make:- ASIAN/ CROMPTON/ Bajaj as approved by AGE
10M&L for cleaning of complete indoor/outdoor units of 1.5 TR Capacity Split Air conditioner by means of adding, cleaning solution (HCL) or equivalent solution with water all asdirected by Engineer in Charge.Note:- The cleaning of the condenser and chillier units shall be done using nylon brushers till the scaling is removed complete all as specified and as directed.
11M&L for Top up / Gas charging with refrigerant gas (R-22/32/410) for Air conditioner window type / split type of capacity 1.5 / 2Ton after vacuuming &leak testing including bracing suction/discharge line and testing complete all as specified and as directed.
12Starting Capacitor 35 to 45 MFD complete all as specified and as directed.Make:- Topcon / Ducati / Kenton / Concap)
13Universal PCB Timer electronic switch with sensor suitable for all makes of split 1.5 / 2 Ton AC complete with hand setincluding taking down unserviceable Electronic PCB from existing unit all as directed. Make:- Baba/ Wavess or its equivalent as approved by AGE(I)
14M&L for Earthing complete with GI Earth Plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with GI earth lead wire of 4.0 mm by means of nuts/bolts/ check nuts/ wahers , GI pipe light grade of 15 mm bore as protection pipe, GI Strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia light grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
15S & F in repair of LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
16S&F in repair of existing Post light of any type and wattage with New generation, LED Post Top light of wattage 40 Watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete and connecting up with existing cable complete all as specified and as directed. Make: havells, Model: RUBYPT25WLED757PSYMTOPC orequivalentmodel from any manufacture from the list.
17Supply and fixing in repair of LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
18M&L for Earthing complete with GI Earth Plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with GI earth lead wire of 4.0 mm by means of nuts/bolts/ check nuts/ wahers , GI pipe light grade of 15 mm bore as protection pipe, GI Strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia light grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
19Supply and fixing LED street light fitting 35 Watt 230 V AC outdoor type with high pressure die cast aluminum hosing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65/66 protection complete all as specified and as directed.
20S&F in repair of existing Post light of any type and wattage with New generation, LED Post Top light of wattage 40 Watt, energy saving, environmental friendly, long life aesthetically designed with symmetrical light distribution, spun aluminium landscape luminaire with high power LEDs as light source complete and connecting up with existing cable complete all as specified and as directed. Make: havells, Model: RUBYPT25WLED757PSYMTOPC orequivalentmodel from any manufacture from the list.
21Supply and fixing LED flood light 70 watt 230 V AC outdoor type with thermal management in multiple optics and equipped with IP66 protection, with impact and corrosion resistant complete with driver and lamp complete all as specified and as directed.
22M&L for cleaning of complete indoor/outdoor units of 1.5 TR Capacity Split Air conditioner by means of adding, cleaning solution (HCL) or equivalent solution with water all asdirected by Engineer in Charge.Note:- The cleaning of the condenser and chillier units shall be done using nylon brushers till the scaling is removed complete all as specified and as directed.
23M&L for Top up / Gas charging with refrigerant gas (R-22/32/410) for Air conditioner window type / split type of capacity 1.5 / 2Ton after vacuuming &leak testing including bracing suction/discharge line and testing complete all as specified and as directed.
24Starting Capacitor 35 to 45 MFD complete all as specified and as directed. Make:- Topcon / Ducati / Kenton / Concap)
25Universal PCB Timer electronic switch with sensor suitable for all makes of split 1.5 / 2 Ton AC complete with hand setincluding taking down unserviceable Electronic PCB from existing unit complete all as specified and as directed. Make:- Baba/ Wavess or its equivalent as approved by AGE(I)
26M&L for Earthing complete with GI Earth Plate electrode 600x600x6mm buried directly in ground earth pit not less than 2.25 mtr below ground level with top edge of the plate not less than 1.5 mtr below ground level, surrounded from all sides with mixture of charcoal and common salt and electrode connected with GI earth lead wire of 4.0 mm by means of nuts/bolts/ check nuts/ wahers , GI pipe light grade of 15 mm bore as protection pipe, GI Strip of length not more than 7.5 mtr and connected to test point. GI pipe 20mm dia light grade for watering, funnel with wire mesh, PCC pit and RCC (1:2:4) type B-1 for cover with 8 mm dia bar reinforcement both ways @ 140 c/c including excavation and earth work disposal of surplus soil to a distance not exceeding 50 mtr as shown on electrical plate No 3 of SSR 2009 complete all as specified and as directed.
27S&F PVC insulated & PVC Sheathed, Copper Conductor industrial cable, Flat 3 core 4.0 sqmm 1100 Volt, conforming to IS 694, for submersible pump motors complete all as specified and as directed. Make Polycab/ Finolex/ Havells/ Gloster/ Nicco
28Supply and laying or fixing or passing through pipe, 1100 volts grade heavy duty cable with PVC insulated aluminium conductor served with an inner sheathing of PVC tape armoured with galvanised steel wire or tape and overall PVC sheathed 2 core, 6 sq. mm nominal cross section, stranded conductor in service connections complete all as specified and as directed.
29All as Above but 4 Core, 6 Sqmm
30S&F in replacement of 100A MCCB, 415V, 16kA, 4 Pole, fixed thermal and magnet setting complete all as specified and as directed.
31S&F in replacement of Common SS Enclosure suitable for, 100A, MCCB, 4Pole, 415V, Conforms to IEC 60947-3, IS/IEC 60947-3, with interlock and ped lock facility, inbuilt neutral protection, mounting holes, including installation on RCC poles with necessary clamps complete all as specified and as directed.
32M&L for cleaning of complete indoor/outdoor units of 1.5 TR Capacity Split Air conditioner by means of adding, cleaning solution (HCL) or equivalent solution with water all asdirected by Engineer in Charge.Note:- The cleaning of the condenser and chillier units shall be done using nylon brushers till the scaling is removed complete all as specified and as directed.
33M&L for Top up / Gas charging with refrigerant gas (R-22/32/410) for Air conditioner window type / split type of capacity 1.5 / 2Ton after vacuuming &leak testing including bracing suction/discharge line and testing complete all as specified and as directed.
34S & F in replacement of Starting Capacitor 35 to 45 MFD complete all as specified and as directed.Make:- Topcon / Ducati / Kenton / Concap)
35S & F in replacement of Universal PCB Timer electronic switch with sensor suitable for all makes of split 1.5 / 2 Ton AC complete with hand setincluding taking down unserviceable Electronic PCB from existing unit complete all as specified and as directed.Make:- Baba/ Wavess or its equivalent as approved by AGE(I)
36S&F Rotational moulded polyethylene water storage tanks of capacity 500 litres (cylindrical vertical with closed top) hoisted and fixed in position all as specified in SSR Part I including dismantling existing water tanks and removing to store complete all as specified and directed.
37S&F PP-R Tank Connector of Size 25mm complete all as specified and as directed.
38S&F PP-R Brass FTA of Size 32/25 mm x 1\" (Thread must be suitable for insertion of 20mm Float valve) complete all as specified and as directed.
39S&F in replacement of PVC Ball cock with aluminuim rod and Ball of Size 20mm complete all as specified and as directed.
40S&F 63mm outer dia, ISI marked 3-layer PP-R polypropylene random copolymer pipes SDR 7.4 (PN-16) UV stabilized and anti-microbial welded having thermal stability for hot & cold water supply including random fittings, Reducers, TEE, unions laid in trenches including taking up/down existing unserviceable pipes complete all as specified and as directed.
41-Do- But 32 mm
42\"-Do- But 25 mm.
43S&F in replacement of PP-R Gate valves of Size 25mm complete all as specified and as directed.
44-Do- but 32 mm
45-Do- but 63 mm
46De-watering the existing OH Reservior of capacity 5000 Ltrs at 9 mtr staging and cleaning the internal surfaces to remove scales, mud and other foreign materials, applying surfaces with mixture of bleaching powder and water, finally washing with fresh water and treating with one coat of white wash to internal wall and bottom surfaces etc complete for one time, writing in capital letter with black paint as \"Cleaned on (date) & next due on (date), letter\"s height not less than 5cm complete all as specified and as directed.Note :- The unit rate quoted shall deemed to be included for the following :-(a)250 gm of bleaching powder to be used for every 10 liter of fresh water. (b)All the inlet/outlet/over flow wash out connection shall be cleaned as rust free and any leakage in joints shall be made good.(c)The water available in the Reservoir shall be bailed out to the nearest open drain available.(d)Any damage caused during cleaning the existing assets shall be made good by the contractor without any extra cost.e)Arrangement of necessary Scaffolding is arranged by the contractor at no extra cost.
47Excavationin trenches not exceeding 1.5 m wide and not exceeding 1.5 m in depth and gettingout in soft/ loose soil, for under ground electric cable, pipes complete all as specified and as directed.
48Returning, filling-in, including, spreading, watering and well ramming in layers notexceeding 25 cm thick each, in soft /loose soil complete all as specified & directed.
49M&L for connection of 63/32/25 mm PP-R distribution branch with PP-R main of following sizes by providing and fixing tee including cutting and making fusion joint complete all as specified and as directed.

AI Tender Summary

OUR REF NO 45835054
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 7.13 Lakhs
LAST DATE 16-11-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Misc E/M Maintenance Work At Aro Guntur Under Age (I) Suryalanka
Basic Detail
Tender No AGE(I)/SL/8634
Bidding Type Tender
Location
City suryalanka
State Andhra Pradesh
Key Dates
Publish Date 09 Nov 2024
Submission Date 16 Nov 2024
Open Date 18 Nov 2024
Finance
Tender Value 7.13 Lakhs
Tender Fee 500
EMD 14500
Exemption Available
Document List
05db6318-25d6-4cb3-92b6-7773be704fbe.html
8634PS.pdf
BOQ_761115.xls
Tenderdoc8634.pdf
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Nov 09, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2024
18:00 IST

Corrigendum-1 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 16, 2024
18:00 IST

Corrigendum-2 Issued

Clarifications on tender conditions and amendments issued.

Completed
Nov 16, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 18, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

05db6318-25d6-4cb3-92b6-7773be704fbe.html

pdf

8634PS.pdf

xls

BOQ_761115.xls

pdf

Tenderdoc8634.pdf

pdf

Tendernotice_1.pdf

Disclaimer

We takes all possible care for accurate & authentic tender information. However users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender

TenderDetail
Loading tenders