| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 16-11-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 21-11-2024 |
| 2 | 09-11-2024 | Bid Auto Extn Corrigendum | Bid Auto Extn Corrigendum | 16-11-2024 |
| Sl. No. | Item Description |
| 1 | Periodical functional check and servicing of fire fighting system comprising of Auto /Manual operational check of the followingfirefighting /fire hydrant systemm including related electrical control panel installed for the firefighting system for the location MLH/ARS-1 Hanger,complete all as specified and as directed:- (a)Centrifugal pump set of cap 90 KW make Kirloskar - 02 Nos(b)Jockey pump set of cap 11 KW make Kirloskar - 01 No, (c) Electical panel- 01 No(d)Fire Hydrantwith valve on both side -22 Nos, (e)Sluice valve250/200/150/100 mm -27 Nos(f) Pressure switch - 04 Nos,(g) Pressure gauge - 05(h)Hose cabinet - 31 Nos Note :-(i) Any minor defect noticed during function l test (i.e.) making electrical connections into the electrical control panel, filling the graphite packing seal into the gland piece of centrifugal type firefighting pump, replacement of rubber flanged gaskets of size 250/150 mm /100 mm with necessary nuts bolts and washers if required to arrest the leakages etc to make the firefighting system functional shalldeemed to be included in the quoted item rates.(ii)Periodical serviceability /functional test forlocations viz MLH/ARS-1 hanger, Engineer Division and Lean lift building shall be carried out in everymonth from the date of taking over of site in the presence of representative of station fire section. Record of the same shall be maintained and submitted to the Garrison Engineer/Engr-in-Charge duly signed by contractor and his engineer including endorsement from Station fire section.(iii)A recovery of RS 3000/ shall be made against the contractor for each of themonth for non-performing of periodical serviceability functional check within the schedule time for any of themonth (iv) Any major unserviceable item related to firefighting system shall be measured and paid for separately under the respective item of schedule if required to be replaced for making the system serviceable. |
| 2 | Periodical functional check and servicing of firefighting system comprising of Auto /Manual operational check of the followingfirefighting /fire hydrant systemm including related electrical control panel installed for the firefighting system for the locationEngine Divisioncomplete all as specified and as directed:- (a)Centrifugal pump set of cap 15 HP - 01 Nos(b) Centerifugal pump set50 HP - 01 No(c) Electical panel- 01 No(d)Fire Hydrantwith valve on both side -6 Nos(e)Sluice valve150/100 mm -2 Nos(f)Pressure gauge - 01(g) Hose cabinet - 06 NosNote (i) Any minor defect noticed during function l test (i.e.) making electrical connections into the electrical control panel, filling the graphite packing seal into the gland piece of centrifugal type firefighting pump, replacement of rubber flanged gaskets of size 150 mm /100 mm with necessary nuts bolts and washers if required to arrest the leakages etc to make the firefighting system functional shalldeemed to be included in the quoted item rates.(ii)Periodical serviceability /functional test forlocations vizEngineer Division shall be carried out in everymonth from the date of taking over of site in the presence of representative of station fire section. Record of the same shall be maintained and submitted to the Garrison Engineer/Engr-in-Charge duly signed by contractor and his engineer including endorsement from Station fire section.(iii)A recovery of RS 3000/ shall be made against the contractor for each of themonth for non-performing of periodical serviceability functional check within the schedule time for any of themonth. (iv) Any major unserviceable item related to firefighting system shall be measured and paid for separately under the respective item of schedule if required to be replaced for making the system serviceable. |
| 3 | Periodical functional check and servicing of firefighting system comprising of Auto /Manual operational check of the followingfirefighting /fire hydrant systemm including related electrical control panel installed for the firefighting system for the locationLean Lift building,complete all as specified and as directed:- (a)Centrifugal pump set of cap 100HP make Kirloskar - 01 Nos(b)Centrifugal pump set50 HP- 01 Nos, (c) Centrifugal pump set 10 KW- 01 No(d)Diesel Engine driven Pump set 38 KW - 01 No, (c) Electical panel- 02 No(d)Fire Hydrantwith valve on both side -22 Nos(e)Sluice valve250/200/150/100 mm -27 Nos(f) Pressure switch - 04 Nos, (g) Pressure gauge - 05, (h)Hose cabinet - 31 Nos (j) water sprinkler - 161 NosNote :-(i) Any minor defect noticed during function l test (i.e.) making electrical connections into the electrical control panel, filling the graphite packing seal into the gland piece of centrifugal type firefighting pump, replacement of rubber flanged gaskets of size 250/150 mm /100 mm with necessary nuts bolts and washers if required to arrest the leakages etc to make the firefighting system functional shalldeemed to be included in the quoted item rates.(ii)Periodical serviceability /functional test forlocations viz MLH/ARS-1 hanger, Engineer Division and Lean lift building shall be carried out in everymonth from the date of taking over of site in the presence of representative of station fire section. Record of the same shall be maintained and submitted to the Garrison Engineer/Engr-in-Charge duly signed by contractor and his engineer including endorsement from Station fire section.(iii)A recovery of RS 3000/ shall be made against the contractor for each of themonth for non-performing of periodical serviceability functional check within the schedule time for any of themonth (iv) Any major unserviceable item related to firefighting system shall be measured and paid for separately under the respective item of schedule if required to be replaced for making the system serviceable. |
| 4 | Supply and fix in repair brass female coupler for fire hydrand of size 63 mm complete all as specified and as directed. |
| 5 | Supply and fix in repair canvas hose 63 mmwith brass male and female coupler 15 Mtr long conforming to IS-636 complete with male and female coupling conforming to IS-903 complete all as specified and directed. |
| 6 | Supply and fix in repair pressure switch complete all as specified and as directed. |
| 7 | Supply onlyBranch pipe gun metal 63 mm instantaneous inlet, made threaded outlet, 15mm bore nozzle short complete all as specified and as directed. |
| 8 | Supplyand fixingin replacement of cast iron sluice valve heavy dutyclass PN-1.6 conforming to IS 14846-2000with flanged ends 150 mm nominal bore ISI marked complete with gun metal or stainless steel spindle and cast iron hand wheel including rubber /fiber board gasket nuts, washers etc,suitable for fire fighting pressurised pipe lineincluding necessary excavation, returning and filling complete all as specified anddirected . |
| 9 | Supply and fix in repair CI stainer150 mm dia for suction line complete all as specified and as directed. |
| 10 | Supply and fix in repair fire brigade inlet connection 2 way complete all as specified and as directed. |
| 11 | Supply and fix in repair fire brigade inlet connection 3 way complete all as specified and as directed |
| 12 | Supply and fix in repair fire brigade inlet connection 4 way complete all as specified and as directed |
| 13 | Supplying & Fixing of standard Fireman\"s Axe with heavy insulated handle conforming to (IS:926) complete all as specified and directed. |
| 14 | Supply and fix heavy duty MSERW pipe of size 150 mm dia plane end duly welded and painted withone coat of red oxide as primer and two coats of synthetic enamel paint of colour post red complete all as specified and as directed. |
| 15 | Supply & fixing in replacement of 25 mm dia (Nominal Bore)M.SPIPEClass\"C\" (HeavyDuty)pipes conformingtoIS:1239Part-Iincludingcutting,threading,welding&allfittingslikeflanges, tees,elbows,bendsjunctions,reducers,ballvalvesetc.weldedorscrewedjoints,clamps structural steel supports (as per TAC norms) or as required/ directed at site complete all as specified and directed. |
| 16 | Supply & fixing in replacement of 50 mm dia (Nominal Bore)M.SPIPEClass\"C\" (HeavyDuty)pipes conformingtoIS:1239Part-Iincludingcutting,threading,welding&allfittingslikeflanges, tees,elbows,bendsjunctions,reducers,ballvalvesetc.weldedorscrewedjoints,clamps structural steel supports (as per TAC norms) or as required/ directed at site complete all as specified and directed. |
| 17 | Supply & fixing in replacement of 80 mm dia (Nominal Bore)M.SPIPEClass\"C\" (HeavyDuty)pipes conformingtoIS:1239Part-Iincludingcutting,threading,welding&allfittingslikeflanges, tees,elbows,bendsjunctions,reducers,ballvalvesetc.weldedorscrewedjoints,clamps structural steel supports (as per TAC norms) or as required/ directed at site complete all as specified and directed. |
| 18 | Supply & fixing in replacement of 100 mm dia (Nominal Bore)M.SPIPEClass\"C\" (HeavyDuty)pipes conformingtoIS:1239Part-Iincludingcutting,threading,welding&allfittingslikeflanges, tees,elbows,bendsjunctions,reducers,ballvalvesetc.weldedorscrewedjoints,clamps structural steel supports (as per TAC norms) or as required/ directed at site complete all as specified and directed. |
| 19 | Supply & fixing in replacement of two coat of 4 mm thick \"PYPKOTE\" antirust protection including primer and lap of25 mm on M.S. pipe in trenches or complete including surface preparation coating and wrapping shall be confirmto ISI 10221 including conducting Holiday Test complete all as specified and directed. |
| 20 | Supply & fixing in replacementof63 mm dia 15 m long non-percolating flexible hose (RRL- type A) as per IS:636.TypeAwithS.S.male&femaleinstantaneoustypecoupling(IS903) complete all as specified and directed. |
| 21 | Supply & fixing in replacementofwall mounting swinging type first aid fire hose reel with drum, hanging bracket, 36.5 Mtr. length x 20 mm dia high pressure hose reel tubing as per IS: 444 with gun metal (GM) shut off nozzle having 5 mm dia orifice. The hose reel shall be conforming to IS : 884-1985. Rate shall include 25 mm dia M.S. pipe connection from Riser to hose reel, sockets, nipples,elbowsandballvalve(25mmdia).Drumshallbefixedonadjoiningwallthrough anchor fasteners / cement concrete block as and when required.hose reel of 20 mm dia and 30 meter length confirming to IS 8090. Make :- MEC/NEWAGE/ATASEE |
| 22 | Supply & fixing in replacementofweather proof standard fire hose cabinetfor yard hydrants made of 16 SWG powder coated M.S. sheet having single or double opening glazed (4.0 mm thick glass) shutter including necessary locking arrangement by allan key, stove enamelled Fire red finish with \" Fire Hose\" marked on front, suitable for housing - 2 No. Hose pipe,-1 No. branch pipe & nozzle spanner complete all as specified and directed . |
| 23 | Supply & fixing in replacement including taking down old sluice valve CI body with Gun metal/Steel spindle with hand operated iron wheel both ends flanged and drilled including ring, nuts, bolts class PN 1.6 conforming to IS 14846-2000. ISI Marked of 100 mm bore size complete all as specified and directed. |
| 24 | Supply & fixing in replacement including taking down old sluice valve CI body with Gun metal/Steel spindle with hand operated iron wheel both ends flanged and drilled including ring, nuts, bolts class PN 1.6 conforming to IS 14846-2000. ISI Marked of 80 mm bore size complete all as specified and directed. |
| 25 | Supply & fixing in replacementofC.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washersISI Marked of 100 mm bore size complete all as specified and directed. |
| 26 | Supply & fixing in replacementofC.I. Butterfly valve conforming to IS : 13095 with nut, bolts and washersISI Marked of 80 mm bore size complete all as specified and directed. |
| 27 | Supply & fixing in replacementofdual plate non-return valve complete with nuts, bolts and washers. |
| 28 | Supply & fixing in replacementofdual plate non-return valve 100 mm dia complete with nuts, bolts and washers complete all as specified and directed. |
| 29 | Supply & fixing in replacementofdual plate non-return valve 80 mm dia complete with nuts, bolts and washers complete all as specified and directed. |
| 30 | Supply & fixing in replacementofair releasevalveof25mm diaand25mm diagunmetalgatevalvewithfittings etc. to be installed at risers. |
| 31 | Supply & fixing in replacementofburden type Stainless Steel dial type pressure gauge with brass isolationvalve and pipe. (For each internal Fire hose cabinet)Dial Diameter: 100 mm Caliberation : 0-10 Kg/cm2 complete all as specified and directed. |
| 32 | Supply and fixing of framed brackets of angles cut to shaps drilled and cuontersunk for screw, including bending and welding angles as necessary, confirming to Fe.290 Grade complete all as specified and directed. |
| 33 | Disconnecting firefighting centrifugalbooster pump set of capacity 110 HP from foundation and suction/delivery lineand star delta cable connection.Disconnecting of electric motor and pump from MS couplingfor removing the pump and motor from foundation to outside the pump room complete all as specified and directed. |
| 34 | Making necessary arrangement for lifting of electric motor3 phase 415 volts 50 HZ of capacity 110 HP from pump room (below 4.5 mtr to the ground level ) carefully with out damaging motorand buildingand transportingthe same to workshop for repair and repositioning of motor with with pump after repair complete all as specified and directed. |
| 35 | Strip opening of motor of capacity 110 HP 3 phasefor assessment of repair work cutting of damaged winding , taking out unsv ball bearing etc andCleaning of motorrotor and stator with cleaning material. Machining work complete including remateling of rotor shaft etc. replaceemnt of bearing and bush and rewinding of motor with stove enamelled insulatedcopper wire of existing gauge. Repalcement ofunserviceable parts as required. Assembling of motor and testing complete to the satisfaction of Engineer-in -Charge. |
| 36 | M & L for opening and servicing of Monoblock pump of capacity 12.5 HP to 15 HP after dismantling fromexisting platform by disconnecting electric and water connection of pump set , decoupling pump & motor and transportation towork shop and opening the body of motor, oiling greasing of motor & pump set ,replacement of bearing,replacement of mechanical seals of pumps, replacement of bearing, overhauling of pump with proper alignment of pump including all necessary nut, bolts ,welding works and rubber coupling if required for setting of pump & motor complete all as specified and directed. |
| 37 | Strip openingof induction motor 15 HP 3 phase 415 volts 50 HZ and taking out burnt out windings . Cleaning of motorrotor and stator with cleaning material. Machining work complete including remateling of rotor shaft etc. replaceemnt of bearing and bush and rewinding of motor with stove enamelled insulatedcopper wire of existing gauge . Repalcement ofunserviceable parts as required. Assembling of motor and testing complete to the satisfaction of Engineer-in -Charge. |
| 38 | Supply and instalation ECO FIREABC powder type(Stored pressure )FireExtinguisher 4 Kgs conforming to IS code -15683operating tmperature 0⁰tto + 55 ⁰and fire rating2A &21B type of fire filled with MAP Powder complete in all respectand \"A, B,C class fire inflammable liquids(Petrol, Kerosene, Paints, Diesel ) gasesous fire ,LPG and actylene and electrical fire , paper, cloth wood, complete all as specified and directed. |
| 39 | Supply and fixing of brass hydrant brass/bronze valve of100 mm size single headed, complete all as specified anddirected. |
| 40 | Supply and fixingbrass hydrant bronze valve of80 mm size single headed, complete all as specified anddirected. |
| 41 | S&F in replacement of Bronze/brass bodyfoot valve 65mm nominal bore, conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasketand fixing up in CI/DI on Water supply mains and underground sump complete all as specified and directed. |
| 42 | S&F in replacement of Bronze/brass body foot valve 80mm nominal bore , conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasketand fixing up in CI/DI on Water supply mains and underground sump complete all as specified and directed. |
| 43 | S&F in replacement of Bronze/brass foot valve bronz/brass 100mm nominal bore , conforming to IS 4036, duly ISI marked with nut, bolts, washers and rubber gasketand fixing up in CI/DI on Water supply mains and underground sump complete all as specified and directed. |
| 44 | S&F in replacement of Cast Iron non return/reflex valve 150mm nominal bore with by pass arrangementduly ISI marked with nut, bolts, washers complete all as specified and directed. |
| 45 | Material, labour and T&P for Cleaning ofstatic water tank (Fire tank) of capacity 10000 gallons by tank clean process as below :-(a)Pumping out water fromSWT and removing of sludgemechanicallyor mannualy and disposing it off at a distance of not less than 100 mtr from SWT . Cleaning of side wallsandbottom surface byscrubing the deposite and removing the same.Cleaning of the walls with high pressure waterjetand pumping out the dirty water .Sterilization of tank by eco-friendly degradable and highly effecting ( anti becteria and anti fungus chedmical) . Painting of the wall with two coats of cement basespaintover a coat of cement primer and writing date of painting /cleaning on the tank. |
| 46 | All as per item Srl item No 39 here-in-before above but static water tankof cap 50000 gallons complete all as specified and directed. |
| 47 | Earthing complete with GI earth plate electrode 600 x 600 x 6 mm thick burried directly in ground (earth pit not less than 2.5 m deep below ground level) with top edge of plate not less than 1.5 m below normal ground level, earth pit surrounded by 15 cm thick and packed layers of charcoal, dust and common salt, including GI strip 25 x 4 as earth lead fixed by means ofnuts, bolts, check nuts and washers etc and other end connected to the test point including 40 mm dia light grade GI protection pipe and watering pipe 20 mm dia med grade with funnel and wire mesh including necessary earth work, PCC earth pit chamber in PCC 1:2:4 using 20 mm graded stone aggregate with precast RCC pit cover 80 mm thick etc complete all as directed and specified.Note : The earth value/result must be less than 5 ohms. |
| 48 | Excavation in trenches in any type ofsoil not exc 1.5 m wide and not exc 1.5 m deep for laying of pipes etc and getting out including cutting of grass and bushes complete all as specified and directed. |
| 49 | Note : Excavation shall be carried out manually. Use of JCB for excavation in trenches will not be allowed in any case.2.Any damage to existing underground electric cabdle HT/LT, Fiber Optic cable and pipe line shall be repair/make good by the contractor with in 24 hours of the damage failing which double to the amount of repair / making good shall be recovered from the contractor. No extra charges for making good of damage are admisible to the contractor from the department. |
| 50 | Returning, filling in, including, spreading, levelling, watering and well remming in layers not exceeding 25cm thick complete all as specified and directed. |
| 51 | Removal ofsurplussoil to a distance not exc 50 m away and depositing where directed at a level not exc 1.5 above the starting point complete all as specified and directed. |
| 52 | M&L for arresting of water leakage from existing pipe line in position from GI pipe of following sizes 80 to 100mm bore ,including excavation through Men/Mechanical power ,cutting threading, welding as per site requirement, including fixing of jointing material such as GI (Bend, socket, reducer, tee, furrel, union ,solution, thread etc) and refixing etc complete all as specified anddirectedNote:- (i) Excavation up to 1x1x6 Mtr shall be deem to included in quoted rates and excavation beyondthis size shall be measured and paid separately.(ii)cost of Jointing material such as socket, bend, elbow, reducer, nipple , unionand dummy plug required if anyis deemed to be included in the quoted rates (iii)Complaint /breakdown in pipe lineshall be attended and rectified within 6 hrs from receipt of complaint.Contractor shall be penalized @ 500/- per hrsfor non compliance . |
| 53 | All as per srl item No45 here-in-before above but pipe size 40 to 50mmbore nominal bore complete all as specified and directed. |
| 54 | All as per srl item No45 above but pipe size 15 to 25mm bore nominal bore complete all as specified and directed. Note for Srl Item No 45 to 47: Contractor will provide an experienced pipe fitter and helper alogwith tools required for repair to pipe line incl earth workduring the currency of contract . Man power so deputed shall report to complaint cell water supplyand collect complaint slip/job card in between 0900 to 1000 hrs and will deposite the same on rectification of complaint on the same day. Pipe fitter with helper not reported to complaint cell on any working day and any complaint left unattended due to non availability of man powercontractor will be charges Rs 500/percomplaintand amount will be recovered from the RAR. |
| 55 | Supply only rubber gasket suitable for pipe ofsize 100/150 mm complete all as specified and as directed |
| 56 | Supply only MS nuts and bolts long thread and washer for column pipe/CI pipe flanged type fittins complete all as specified and as directed |
| 57 | S&F in repair power contractor 3 pole ML-4 conforming to cat part No SS-90910 of L&T with DC coil of AC3 rating 70 to 110 Amps suitable for motor including connection with new copper cable of suitable size and connection with new copper lugsand testing for smooth and trouble free running of starter on load, complete all as specified and directed. |
| 58 | S&F in repair power contractor 3 pole Type MNX95 (2NO+2NC) 3 pole of L&T cat part No CS 94136 with DC coil of rating AC-3 160 Ampssuitable for motor including connection with new copper cable of suitable size and connection with new copper lugsand testing for smooth and trouble free running of starter on load complete all as specified and directed. |
| 59 | S&F power contactor 3 pole ML- 2 of L& T with DC coil of AC-3 rating 60 Amps suitable formotor including connection with suitable size copper cable and removing unserviceablecable and connection with new copper lugs, nut bolts including taking out old unserviceable contactor form existing LT panel of pump house, complete all as specified and directed. |
| 60 | All as per Srl Item No 52 here-in-beforeabove but capacity 3 pole MNX 50 ( model as per site requirement) complete all as specified and directed. |
| 61 | Allas per Srl Item No 52 here-in-before above but capacity 3 pole MNX 70 ( model as per site requirement) complete all as specified and directed. |
| 62 | All as per Item No60above but capacity 3 pole MNX 140 ( model as per site requirement) complete all as specified and directed. |
| 63 | M & L for MCCB, TPN, 400 Amp, 415 volt ,ISI marked adjustable type thermal magnetic release breaking capacity36 KA as in repair complete all as specified andas directed by Engineer-in –charge. |
| 64 | M & L for MCCB, TPN, 250 Amp 415 volt ,ISI marked adjustable type thermal magnetic release breaking capacity25 KA as in repair complete all as specified andas directed by Engineer-in –charge. |
| 65 | M & L for MCCB, TPN, 200 Amp 415 volt , ISI marked adjustable type thermal magnetic release breaking capacity25 KA as in repair complete all as specified andas directed by Engineer-in –charge. |
| 66 | M & L for MCCB, TPN, 160 Amp 415 volt ,ISI marked adjustable type thermal magnetic release breaking capacity25 KA as in repair complete all as specified andas directed by Engineer-in –charge. |
| 67 | M & L for MCCB, TPN, 100 Amp 415 volt ,ISI marked adjustable type thermal magnetic release breaking capacity16 KA as in repair complete all as specified andas directed by Engineer-in –charge.Note for item : Make and frame size of thenew MCCB should be as per the existing unsv MCCB so that new MCCB can be fixed and connected properly in the panel |
| 68 | Supply, fixing connecting and testingMotor protection unit (MPU)three phae415 volt , 50 HZ ,automatic phase sequence correctorautomatically correct input reverse phase, single phase protection, LV, HV, LIV, Auto of loft, timer, Dry running under & over current, unbalancing ,float switch with built in CTs (Automatic-RTM ) complete all as specified. & directed. |
| 69 | Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 95 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tapecomplete all as specified and as directed. |
| 70 | Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 120 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tape complete all as specified and as directed. |
| 71 | Supplying, laying, jointing, testing and commissioning under ground XLPELT electric cable1100 Volts grade, heavy duty,PVC insulatedand sheathed armoued electric power cable with stranded aluminium conductor, of cross sectional area 185 Sqmm 3.5 core conforming to IS- 7098 (Part I) 1988 as in trenches over brick and sand cushioning or along the wall/pole through pipe etc served with an inner sheathing of PVC tape and overall PVC sheathed armoured with galvanized steel wire or tapecomplete all as specified and as directed. |
| 72 | M & L for sand filling using approved clean dry sand for cushioning of under groundcables incl spreading levelling and well ramming in layers not exc 25 cm complete all as specified and directed. |
| 73 | Supply and laying of class \"B\" bricks for under ground cable protection as directed by Engineer- in - charge |
| 74 | S & Fin repair 40 mm bore Tubes‘light grade’ ISI marked galvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified and directed. |
| 75 | S & Fin repair 50mm bore Tubes‘light grade’ ISI markedgalvanized with all fittings, laid in trenches or fixed along poles with mild steel clamps, as protection to cable, complete all as specified . |
| 76 | S&F in repair PVC insulated multistranded copper cable of size 10 sqmm with copper thimble complete all as specified and as directed. |
| 77 | S&F in repair PVC insulated multistranded copper cable of size 25 sqmm with copper thimble complete all as specified and as directed. |
| 78 | S&F in repair PVC insulated multistranded copper cable of size 35 sqmm with copper thimble complete all as specified and as directed. |
| 79 | S&F in repair PVC insulated multistranded copper cable of size 50 sqmm with copper thimble complete all as specified and as directed. |
| 80 | Taking shutdown for LT panel Servicing/repair outdoor/indoor type by fixing of broken hinged doors with welding , replacement of locking arrangement, handle, burnt /rustedout,bus bar as per existing size and shape, control rewiring ,voltmeter ammeter,CTs, indicating lamps,selector switches,loose or burnt thimble of any size ,old rusted/burnout nuts/bolts & washers,complete tighening of all nuts/bolts insulation tape to all joints refixing of any loose switchgear,cable glands complete including scrapping of surfaces of LT panel, applying two coats of synthetic enameled paint after one coat of primer ,cleaning/cutting of nearby grass bushes all as specified and as directed. |
| 81 | Taking out unserviceableAMMETER from diffrent location supply and fixAmmeter square flush mounted digital typetype of size 96x96mm of range 0-200 Amp, complete all as specified and directed by the Engr -in -charge. |
| 82 | Taking out unserviceable VOLT METER from diffrent location supply and fixVOLTMETERsquare flush mounted analogtype of size 96x96mm of range 0-500 Amp, complete all as specified and directed by the Engr -in -charge. |
| 83 | Schedule of Credit |