Sales : +91-777 804 8217
| Sr No | Corrigendum Date | Corrigendum | Type | New Submission Date |
|---|---|---|---|---|
| 1 | 08-11-2024 | Corrigendum No 01 | Date | 16-11-2024 |
| Sl. No. | Item Description |
| 1 | S&F steel tubing medium grade 15mm bore with all fittings fixed complete to wall and or laid in floor all as specified. |
| 2 | S&F steel tubing medium grade 20mm bore with all fittings fixed complete to wall and or laid in floor all as specified. |
| 3 | S&F rotational moulded polyethylene water storage tanks (white colour) (cylindrical vertical with closed top) of capacity 1000 Ltrs hoisted and fixed in position incl all necessary fittings (nipple, socket, union etc) complete all as specified in SSR Part I and removing to store with and including 20mm dia ball valves, high pressure of PTMT with epoxy coated aluminium rod & high density plastic ball, screwed for iron pipe, minimum weight - 210 gms ball valves , complete all as specified and directed. |
| 4 | S&F 20mm dia brass Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 5 | S&F coloured wash hand basin table top with built up counter and sutters of size 595 mm x 445mm x 135mm complete all as specified and directed.Make : Jaguar Cat Part No JDS-WHT-25931 |
| 6 | S&F fancy type center hole basin mixer without popup waste system but including plain waste coupling 32mm size with aerator complete cast copper alloy, chromium plated, screwed down, high pressure, with long screwed shanks and fly nuts screwed for iron pipe of 15mm bore complete all as specified and directed.Make : Jaquar Cat Part No OPP-15011BPM |
| 7 | S&F PVC connection of 15mm bore with2 Nos. PTMT nuts, 600mm long fixed with adapter and washers at both the ends complete all as specified and as directed |
| 8 | S&F tubular towel rail, 20mm dia, D type, 60cm long between flanges of Brass chromium plated complete all as specified and directed |
| 9 | S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints laid in walls as in weep holes complete all as specified & directed |
| 10 | S&F PVC (SWR) pipes 110 mm bore single socketed, in any length with rubber ring joints fixed to walls complete all as specified & directed |
| 11 | S&F PVC (SWR) pipes 75 mm nominal outside diameter(Type B with wall thickness 3.20 to 3.80 mm) single socketed in any length with rubber ring joints laid in trenches or in floors complete all as specified & directed |
| 12 | S&F PVC (SWR) bends any radius 110 mm borecomplete all as specified & directed |
| 13 | S&F PVC (SWR) bends any radius 75 mm borecomplete all as specified & directed |
| 14 | S&F 75mm dia PVC (SWR) floor trap plain with grating including jointing with solvent cement complete all as specified & directed |
| 15 | M&L rendering 15mm thick in CM (1:6) on other than fair faces of brick/stone masonry or concrete surfaces of walls, finished even & smooth without using extra cement complete all as specified. |
| 16 | M&L rendering 15mm thick in CM (1:4) on brick/stone wall surfaces on fair faces of brick work & surfaces, finished even and smooth without using extra cement with water proof compound.Note :- Water proofing compound shall be measured and paid separately here-in-after. |
| 17 | M&L rendering 10mm thick in CM (1:4) on brick/stone wall surfaces on fair faces of brick wall or concrete surfaces complete all as specified and directed. |
| 18 | M&L rendering 5mm thick in CM (1:3) on concrete surfaces in ceiling, soffits and the likes; finished even & smooth without using extra cement complete all as specified. |
| 19 | M&L rendering 5mm thick in CM (1:4) on concrete surfaces such as beams, columnand the likes; finished even & smooth without using extra cement complete all as specified. |
| 20 | M&L rough cast plaster on exterior wallsapplying the under coat of cement and sand mortar (1:3) not less than 10mm thick and while it is still in plastic state the roughcast mixture consisting of crushed stone or fine gravel aggregate (size between 6 to 12mm ) mixed with coarse sand and cement in the raio of 1:1:1 shall be applied and finished even.The mix of cement and sand shall made slightly wetter than normal for rendering to ensure that larger aggregate are thoroughly covered completeall as specified and directed |
| 21 | M&L providing and applying cement base putty 1mm thickness over plastered surface to prepare the surface even and smooth complete all as specified & as directed |
| 22 | M&L preparation of newly plastered surfaces of walls and applying two coats of weather proof paint (Appex paint of approved shade/tint over a coat of primer complete all as specified & as directed |
| 23 | M&L preparation of newly plastered surfaces of wall, ceilings and applying two coats of oil bound distemper over a coat of primer complete all as specified & as directed |
| 24 | M&L RCC M-25 Design mix (using 20mm graded stone aggregate) as in foundation including footing, plinth beam, base for column, etc complete all as specified anddirected. |
| 25 | M&L RCC M-25 Design mix (using 20mm graded stone aggregate) as in columns, pillars, piers, posts and strutsetc complete all as specified and directed. |
| 26 | M&L RCC M-25 Design mix (using 20mm graded stone aggregate) as inbeams, cantilevers, bressummers and lintels over 1.5m span complete all as specified anddirected. |
| 27 | M&L RCC M-25 Design mix (using 20mm graded stone aggregate) as inslabs sopported on walls, beams and columns in floors, roofsetc complete all as specified anddirected. |
| 28 | M&L RCC M-25 Design mix (using 20mm graded stone aggregate) as inchajjas and the likes; complete all as specified anddirected. |
| 29 | M&L mild steel (TMT bar) 10mm dia and over cut to length bent to shape reqd, incl, cranking benching spirally for hooping for columns hooking ends and bending with and including MS wire annealed wire not less than 0.9 mm dia. |
| 30 | M&L mild steel (TMT bar) 5mm to 10mm dia and over cut to length bent to shape reqd, incl, cranking benching spirally for hooping for columns hooking ends and bending with and including MS wire annealed wire not less than 0.9 mm dia as in stirrups, spacers, binders etc. |
| 31 | M&L form work to side of concrete foundation , footing, bases of columns, raft and raft beams, sides and soffits (If any) of foundation and plinth beams and similar work, vertical or to batter complete all as specified and as directed |
| 32 | M&L form work to side of pillar, posts, struts, piers, columnsetc complete all as specified and as directed |
| 33 | M&L form work to sides and soffits of floor or roof beam, beam haunching, griders, bressummers lintels, cantilevers, shelves including supprots, overhangs etc also splays between floors and beams etc complete all as specified and as directed |
| 34 | M&L form workas in suspended slab, such as roof slabs, floor slabs, landings and similar work, not exceeding 20mm thick(Horizonal or sloping) complete all as specified and as directed |
| 35 | M&L form work to chullah hoods, chajjas, troughs and similar items including edges complete all as specified and as directed. |
| 36 | M&L treating the bottom and side of excavationat the rate of 5 Ltr/sqm (ATT) emulsion of surface area complete all as specified and as directed. |
| 37 | M&L treating the backfil in contact with foundation at the rate of 7.5 Ltr/sqm (ATT) emulsion of surface area complete all as specified and as directed. |
| 38 | M&L treating the bottom surface of floorat the rate 5 ltr/sqm emulsion (ATT) of surface area complete all as specified and as directed. |
| 39 | M&L treating the soil under plinth protection at the rate of 5 Ltr/Sqm emulsiom (ATT) of surface area complete all as specified and as directed. |
| 40 | M&L 25 thick PCC (1:2:4), Type B-0 (using 12.50mm graded crushed stone aggregate) as infloors sub base,levelling course complete all as specified and as directed. |
| 41 | M&L Vitrified tiles 8 to 10 mm thick (dark shade, double charged/ultra charged), (square/ rectangular) polished, area of each tilesexceeding 0.36 Sqm but not exceeding 0.42 Sqm, as in floors etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match laid over with and including 15 mm thick screed bed in CM (1:6)complete all as specified and directed. |
| 42 | M&L 50mm thick PCC (1:3:6) type C1 (using 20 mm graded stone aggregate) as in plinth, surface to be finished even and smooth without using extra cement.Plinth protection shall be laid in panels n.exc 1.5 mtr, 6mm wide and 10mm deep joints shall be made between wall & plinth protection and between panels.Joints shall be filled with bitumen mastic and sand in proportion 1:3 (one part of bitumen and three parts of sand) complete all as specified and directed. |
| 43 | M&L Vitrified tiles 8 to 10 mm thick (dark shade, double charged/ultra charged), (square/ rectangular), polished, coloured (light shade as approved), area of each tile exceeding 0.36 sqm but not exceeding 0.42 Sqm, as in wall, dado, skirting etc, set and jointed in neat cement slurry and pointed in white or coloured cement to match the shade of tiles laid over with and including 10 mm thick rendering in CM (1:4) complete all as specified & directed |
| 44 | M&L 18-20 mm thick Granite(of any type) work (table rubbed and polished) as in steps, jambs, pillars, window cills, cooking platforms and the likes; in CM (1:4) including pointing in white cement (1:2) using marble dust with admixture of pigment to match withshade of granite laid over with and including 15 mm thick screed bed or bedding layerin CM (1:3), including grinding of edges to curved surface finish complete all as specified and directed. |
| 45 | S&F framed work such as grills, gratings etc., with ends of bars shouldered and/or riveted, or forged into spikes; framed guard bars; barred iron doors; ladders; framed balusters; walk ways; railings; framework of water tanks and similar work conforming to Fe 290 or E-165complete all as specified & directed |
| 46 | M&L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 47 | M&L brick work with sub class \"B\" bricks, straight or curved on plan exc 6 mtr mean radius built in cement mortar (1:6) complete all as specified and directed. |
| 48 | M&L brick work with FLY ASH BRICKS {As per IS-13757 (1993) burnt clay fly ash building bricks}, (OLD SIZE BRICKS) straight or curved on plan to any radius in half brick thick wall, built in cement mortar (1:4) complete all as specified and directed. |
| 49 | M&L stone walling of random rubble, uncoursed, well bonded, laid in dry in retaining walls abutments and similar work complete all as specified and directed. |
| 50 | M&L flush pointing in CM (1:4) to square rubble masonry coursed or uncoursed surface complete all as specified and directed. |
| 51 | M&L hand packing (any thickness) of crushed stone/gravel over each weep hole at back of walls over arches etc (size of stone 40mm to 60mm)complete all as specified and directed. |
| 52 | S&F 30mm thick flush shutter, factory made, solid core construction with block board core and plywood face panels, both face covered with decorative face veneer with lipping/frame to match commercial type on both sides with self closing circular knob for locking arrangments complete all as specified & directed |
| 53 | S&F 30 mm thick 2nd class hard woodGlazed and skeleton shutters, open rebated and prepared to receive glass, gauze, etc. (without sash bars), edge of framing plain, chamfered or rounded, fitted with cut and mitred beds for securing glass, etc.; sizes of members of shutters as specified in SSR Part I, Section 8. clause 8.24 (a); supplied and fitted to chowkats complete all as specified & directed |
| 54 | S&F SS sliding door bolt with hasp and staples type, 300mm long stove enamelled black with bright bolt not less than 12mm dia with and incl minimum of 06 bolts and nuts, 4 on plate and 2 on staple plate and fixed complete all as specified & directed |
| 55 | S&F SS butt hinges 100mm long medium weight complete all as specified& directed |
| 56 | S&F 300mm long SS barrel tower bolts and fixedcomplete all as specified & directed |
| 57 | S&F 150mm size SSalloy handles, fabricated type complete all as specified & directed |
| 58 | S&F MS retractable door hinge including all necessary screws and welding for fixing to door frame and shutters complete all as specified & directed |
| 59 | Preparation of new wooden surfaces over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of pink primer complete all as specified & directed |
| 60 | M&L framed work as in doors or gates, cooler stands etc of angle or other section with gusset plates, rails, braces, etc., complete, drilled for fixing of steel sheeting or other covering. Doors, etc. to be prepared for hanging or sliding with and including either hooks and hinges or steel hanging door fittings (exclusive of steelsheeting or other covering, running rails and guides) and hanging; also fastening and fixing complete & making good the floor in PCC (1:2:4) type B-0 to match the existing floor Fe-410 (Gde-E250 quality A). |
| 61 | Preparation of new steel surfaces of any description over 10 cm width or girth and applying two coats of synthetic enamel paint over a coat of red oxide primer complete all as directed |
| 62 | S&F Aluminium windows made of 1.59 thick powder coated (thickness of powder coating not less than 50 micron) as per aluminium section of size given below. Aluminium window will be of double shutter of glass/wire gauge shutters including 75mm pitch aluminium grill fixed to frame with Aluminium U channel including allnecessary accessoriesjointing cleats , glazing clips, rubber neoprene packing, for fixing glass/ wire gauge,aluminium handles and tower bolt 2 Nos 100 mm ‘D’ Type in each door, 2 Nos 100 mm aluminium hinges including necessary steel screws complete all as specified and directed by Engr-in-charge.The size of different aluminium section to be used is as under (a) Outer Frame 125X24X1.5 mm thick (b)shutter frame section size 46X44X1.18mm thick for glass and 44x25x1.59mm for wire gaugeNote: Rates quoted are inclusive all fittings and fixtures. Glass and wire gaugewill be paid separately in respective items. |
| 63 | S&F glavanised mild steel wire cloth 0.56mm nominal dia of wire and average width of aperature 1.18mm and fixed with tinned tacks or GI wire staples or nails and screws to wooden/steel frames with beading complete all as specified and directed. |
| 64 | S&F 4.80mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc. 0.5 Sqm in each pane complete all as specified and directed |
| 65 | S&F 3 mm thick sheet glass ordinary quality and glazing with oil putty in squares n.exc. 0.5 Sqm in each pane complete all as specified and directed |
| 66 | M&L 15mm thick screed bed on fair faces of concrete/brick surfaces in CM(1:4) with water proofing compound @ 3% by weight of cementeven and smooth in order to maintain proper slope over existing roof surfaces for laying APP based polymeric membrane finished complete all as specifiedNote : Water proofing compound shall be measured and paid separately here-in-after. |
| 67 | M&L water proofing treatment to RCC roof slab including parapet comprising of following course of treatement/specified from bottom to top (a)Applying Bituminous primer @ 0.40 Ltr per sqm over plastered surfaces of roof including parapet surfaces. (b)Over the priming coat laying one layer APP based polymeric membrane of approved manufacturer, 3 mm thick weight not less 3.6 Kgs/Sqm and upper side of membrane thermally insulated with white mineral gravel finish , unifirmly embeded during manufacturing process shall only be used, it shall be laid by torch application, side overlap should be 75mm and end shall be 100mm.For parapets, membrane shall be taken to a height of minimum 60cm and then inserted inside parapet in groove.The same shall be finished by a membrane flashing complete all as specified and directed. |
| 68 | M&L two coat of heat resistance paint over APP membrane complete all as specified and directed. |
| 69 | Supply only Integral water proofing compound |
| 70 | M&L100mm thick PCC (1:4:8), type D-2 (using 40 mm graded stone aggregate) as in sub base of floors, pavings, pathways etccomplete all as specified & directed |
| 71 | M&L 75mm thick PCC (1:4:8), type D-2 (using 40 mm graded stone aggregate) as in sub base of floors, pavings, pathways etccomplete all as specified & directed |
| 72 | M&L PCC (1:4:8) type D-2 (using 40 mm graded stone aggregate) as in foundation, fillings and mass concrete complete all as specified & directed |
| 73 | M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in foundation, fillings and mass concrete complete all as specified & directed |
| 74 | M&L PCC (1:3:6) type C-2 (using 40 mm graded stone aggregate) as in surface channel and drains and benching including finishing the top of benching even and smooth using extra cement complete all as specified & directed |
| 75 | M&L extra for forming fair finished drain or channel 30cm inner girth in cement concrete, using extra cement, including forms, moulds, mitred/stopped ends etc complete all as specified & directed |
| 76 | M&L PCC (1:5:10) type E-2 (using 40 mm graded stone aggregate) as in foundation,fillings and mass concrete complete all as specified & directed |
| 77 | M&L 80mm thick machine pressed precast concrete interlocking paver block with grey cement andpigment any shape and size confirming to IS 15658-2006 , M-40 Grade complete all as specified and as directed |
| 78 | M&L sand filling under floors or in foundations including watering and consolidation complete all as specified and as directed |
| 79 | M&Lproviding and laying at or near ground level factory made kerb stone of M-25 grade cement concrete in position to the required line, level and curvature, jointed with cement mortar 1:3 (1 cement: 3 coarse sand), with and including making joints with or without grooves (thickness of joints except at sharp curve shall not be more than 5 mm) with and including making drainage opening wherever required complete all as specified and as directed. |
| 80 | Surface dressing n.exc 15cm deep and getting out in soft/loose soil including grubbing out bushes, vegetation complete all as specified and directed. |
| 81 | Rough excavation of soil not exceeding 1.5 mtr deep and getting out in soft/loose soil complete all as specified and directed. |
| 82 | Exacavating over areas, n.exc 1.5 m deep and getting out in soft/loose soil complete all as specified and directed. |
| 83 | Excavation in trenches n.exc. 1.5 Mtr wide and n.exc. 1.5 Mtr in depth for foundation and getting out in soft/loose soil complete all as specified and directed. |
| 84 | Excavation in trenches n.exc. 1.5 Mtr wide and depth exc. 1.5 Mtr but n.exc 3.00 Mtr for foundation and getting out in soft/loose soil complete all as specified and directed. |
| 85 | Returning, filling in, including spreading, levelling, watering and well ramming in layers not exc 25 cm in soft/loose soil complete all as specified and directed. |
| 86 | Removing excavated material, exc 50 Mtr but n.exc 100 Mtr and depositing where directed at a level n.exc 1.5 Mtr above the starting pointcomplete all as specified and directed. |
| 87 | Removing excavated material, n.exc 50 Mtr and depositing where directed at a level n.exc 1.5 Mtr above the starting pointcomplete all as specified and directed. |
| 88 | Removing excavated material, exc 50 Mtr but n.exc 250 mtr and depositing where directed at a level n.exc 1.5 Mtr above the starting pointcomplete all as specified and directed. |
| 89 | Spreading, levelling and ramming under floor in layers n.exc 25 cm thick complete all as specified and directed. |
| 90 | S&F 75mm thick steel fibre reinforced concrete (SFRC) man hole cover with iron frames (medium) complying to the standard specifications as mentioned in the IS 12592 BIS Standard, minimum load bearing capacity 5 ton/sqm, in square, rectangular or circular shape complete all as specified & as directed. |
| 91 | M&L PCC (1:2:4) type B1 (using 20 mm graded stone aggregate) as in copings, kneelers, apex stones, bed plates, kerbs, water troughs and the like including weathering, slightly rounded or chamfered angles and throating with and including necessary form work complete all as specified and directed. |
| 92 | M&L point wiring complete with 1.5 Sqmm single core multistranded copper conductor fire resistant low smoke (FRLS) PVC insulated and unsheathed cable 1100 Volts grade confirming to IS-694 drawn through non metallic rigid PVC heavy duty conduit in concealed (min 20 mm external dia) but shall be increased as per actual site requirement in accordance with clause No. 19.125 of SSR Part-I ISI marked with wall thickness not less than 1.8 mm including conduit accessories like bends, tees, junction boxes etc fixed concealed/recessed in wall or ceiling including 1.5 mm FRLS PVC insulated unsheathed copper earth wire including sunken type pressed steel terminal boxes electro plated of suitable size with bakellite white/coloured top sheet cover 3.0 mm thick for one light point controlled by one way switch all as specified & directed.Note : (i)Quoted rates shall be inclusive of modular sunken flush boxes of any type of enclosure including cover plate any size as per site requirement.(ii)Circuit wire from DB to switch boards shall be included in quoted rates |
| 93 | All as per serial item No. 92.00 here-in-before but for one fan point controlled by one switch and regulator |
| 94 | All as per serial item No. 92.00 here-in-before but for one exhaust fan point controlled by one switch |
| 95 | All as per serial item No. 92.00 here-in-before but for one 3 pin 5/6 Amp socket outlet controlled by one 5 Amp switch on same board. |
| 96 | All as per serial item No. 92.00 here-in-before but for one 3 pin 15/16 Amps socket outlet controlled by one 15/16 Amps switch on independent board with 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade including 4.00 Sqmm single core PVC insulated and unsheathed multistranded copper conductor FRLS cable 1100 Volt grade as continuous earth wire in green colour. |
| 97 | S&F modular switch 1 way 6A, 1 module |
| 98 | S&F modular switch 1 way 16A, 1 module |
| 99 | S&F socket, 6A-2/3 pin combined, 2 module |
| 100 | S&F socket, 6A/16A-2/3 pin combined, 2 module |
| 101 | S&F ceiling rose surface bakelite 65mmx50mm with two or three terminal complete all as specified. |
| 102 | S&F 40mm bore, light grade, GI pipe for protection of LT cable fixed to walls/poles/under road crossing including clamps etc complete all as specified and directed. |
| 103 | S&F 25mm bore, medium grade, GI water tubing IS-1239 marked, with and incuding all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed surfaces to match with the existing finish complete all as specified and directed.Note : Excavation and earth work shall be measured and paid separately under relevant items. |
| 104 | S&F 40mm bore, medium grade, GI water tubing IS-1239 marked, with and incuding all necessary pipe fittings laid in trenches, on wall, under floor, under road on same or new route and making good the disturbed surfaces to match with the existing finish complete all as specified and directed.Note : Excavation and earth work shall be measured and paid separately under relevant items. |
| 105 | S&F LED batten (1.2 m) made of CRCA sheet housing with a PC glossy diffusers duly prewired connection having nominal system efficiency of 115 lumen per watt and total power consumption not more than 20 watt including driver.It shhoul have rated system life time of 40000 burning hours at L70 and should have a temperature of 6500 K CRI >80, thd < 10 and PF>0.95 complete all as specified and directed.Make : Crompton cat part No. CIS-305-40-57-SL-DP-NWH, Phillips cat part No BN308C LED20S-6500 L120 PSUWH, Havells cat Part No STOUTPLUS600BS20WLED840SPCWH |
| 106 | S&F LED street light fitting 35 watt 230 V AC outdoor type with high pressure die cast aluminium housing and heat resistant complete with driver, lamp bracket with impact and corrosion resistant including thermal management in multiple optics complete with IP 65 protection complete all as specified and directed. |
| 107 | Supply, fixing, testing and commissioning ceiling fan with copper winding, 1200mm sweep, minimum 350 RPM, minimum air delivery 215 cubic metre /hour, BEE 5 Star rated, canopy, down rod, electric driven single phase 230 volts, AC 50Hz with brushless direct current motor (BLDC) including marking of MES No with synthetic enamel paint complete all as specified and directed. |
| 108 | S&F exhaust fan with copper winding, metal body AC single phase 230 Volts of size 450mm sweep with louvers complete all as specified and directed.Note :(i)Rate are inclusive of making hole of suitable size in existing wall of any size and type (ii)Rate are inclusive of providing iron shutters of suitable size. |
| 109 | S&F distribution board (DB), double door type made out of sheet metal enclosure (CRCA sheet) dust and vermin proof DB, TPN 4 way with 200 Amps rated copper bus bar, 415 volts with inbuit MCCB 63 Amps, 16 KA, 1 No earth bar IP 43 protection, fixed flush to wall complete all as specified and directed. |
| 110 | S&F MCB 6-40 Amp, single pole240 Volt complete all as pecified & directed. |
| 111 | Supply, laying, jointing and testing XLPE insulated armoured heavy duty LT under ground electric cable with aluminium stranded conductor 1100 Volt grade cross sectional area 25 Sqmm 4 core laid in trenches/ducts, through pipe, under floors or roads/ along poles etc complete all as specified & directed.Note : Sand cushioning, cable protection, GI protection pipe, clamps, jointing kits and excavation & earth work shall be measured & paid separately under relevant items. |
| 112 | M&L earthing complete with galvanized steel earth plate electrode 60cmx60cmx6mm thick burried directly in ground (earth pit not less than 2.25 m deep below ground level) with top edge of plate not less than 1.5 m deep below normal ground level and connected to and including galvanized iron earth wire 4 mm dia by means of GI nuts, bolts, check nuts, washers thimbles, etc as shown in electrical plate No 3 of SSR Part-I and connection to main switch board/Test point/panel/equipment and testing on completion including excavation and earth work in any type of soil, returning filling in, and removal of surplus spoil to a distance not exc 50 metre, charcoal and salt in alternate layer 15 cm thick all around the earth plate electrode, MS funnel with wire mesh, GI pipe medium grade 20 mm bore for watering and 15 mm bore 3.00 metre long GI pipe light grade for earth wire protection fixed with poles with two clamps, made from MS flat 25 mmx3mm, bolts, nuts and washers,PCCchamber (1:3:6) type C1, 40mm thick precast RCC cover 1:2:4 type B1 shall be provided on CI frame etc complete all as specified &directed. |
| 113 | M&L brick work with FLY ASH BRICKS(As Per IS-13757(1993) burnt clay fly ash building bricks), (OLD SIZE BRICKS) with width equal to the length of the brick laid dry & flat abutted with each other with gap between adjacent bricks not exc 10 mm over UG cable for protection and complete all as specified & directed. |
| 114 | M&L dry sand and punning for cushioning to under ground cable all as directed.Note :- For the purpose of payment only punned thickness shall be measured. |
| 115 | S&F fabricated outdoor LT feeder distribution panel of size 60 cm x 30cm x 60cm (CPRI approved) LT electrical distribution panel board floor mounted cubicle type suitable under mentioned incoming and outgoing MCCB and MCB, one multifunction LED meter dust proof weather proof, vermin proof asthetically designed having at least IP-54 degree of ingress protection fabricated from 3.15 mm thick CRCA sheet with front and rear opening including bus bar chamber continuous GI strip earth bus bar 4 strip of Aluminium bus bar 100 Amp capacity over angle iron frame of size 40x40x6mm , 30cm grouted in ground floor and 30cm above GL including connection with suitable copper cable PVC single core complete all as specified and directed.(i)MCCB 63 Amps, 16 KA, 4 pole with adjustable thermal setting -01 No ( Incoming)(ii)MCCB 40 Amps 16 KA, 4 pole with adjustable thermal setting - 01 No ( Outgoing)(iii)MCB TPN 20 Amps, 10 KA-01 No (Outgoing)(iv)LED multifunction meter of suitable size |
| 116 | S&F 25mm dia brass Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 117 | S&F 40mm dia brass Gun-metal, globe or gate valves with iron wheel head, screwed both ends for iron pipe and fixed complete all as specified and directed. |
| 118 | M&L cutting the existing GI/DI/CI pipe of size 200mm/150mm/100mm dia and taking out 40mm dia branch connection including necessary fittings etc complete all as specified and directed. |
Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy