| Sl. No. | Item Description |
| 1 | SECTION -A DEMOLITION & DISMANTLING WORKRepairs to plaster in patches of 2.5 sq.m. and under including cutting the patch in proper shape and preparing and plastering the surface of the walls complete including disposal of rubbish to the dumping ground within 50m lead. With cement mortar 1:4 (1 cement : 4 fine sand) |
| 2 | Dismantling doors, windows and clearestory windows (steel or wood) shutters including chowkhats architrave holdfast etc. complete and staking within 50 mt. Lead - Of area 3 sq.m. and below |
| 3 | Dismantling old plaster or skirting raking out joints and cleaning the surface for plaster including disposal of rubbish to the dumping ground within 50 mts. lead. |
| 4 | Dismantling the tile & stone work in all thickness in floorslaid in single /multiple layers (ceramic/mosaic/kotha or any other flooring etc)in cement /adhesive as case may be including stacking of dismantled materials within50 Meters lead etc complete. Note :- Single plan area for (ceramic +misaic + any other flooring) will be considered for payment. |
| 5 | Dismantling the tile /stone workin dados /cladding /skirting at all levels laidin cement mortar including stacking of unserviceable materials within50 metres lead for thickness of tiles /stone 8mm to 30mm as directed by Engineer |
| 6 | Demolishing brick work in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 7 | Demolishing laterite stone masonry in cement mortar including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 8 | Scraping of existing Neeru/POP /wall putty from the wall /ceiling surface so as to expose the existing plaster including disposal of all rubbish /dust created at all leads and lift as directed by Engineer |
| 9 | Dismantaling and removing of existing Storage cabinets/Countersmade up in plywood/Prelam board of all sizes and fixed over with laminate/veeners etcand disposal of all dismantled unserviceable material at all leads and liftsas directed by Engineer |
| 10 | Dismantling asbestos sheet roofing including ridges, hips valley and gutters and stacking the material within 50 meters lead. |
| 11 | Dismantling tiledroofing (mangalore or pot or country tiles) with battens etc. complete including stacking of serviceable material & disposal of unserviceable material within 50 mts. lead. |
| 12 | SECTION -B MASONARY& CONCRETE WORKSBrick work using fly ash bricks in cement mortar 1:4 (1 cement : 4 coarse sand ) with bricks of class designation 40 kgs / cm2. in superstructure upto floor five level.230 x 110 x 80 mm |
| 13 | Providing and laying Halfbrick masonry using fly Ash bricks in cement mortar 1:3 (1 cement : 3 coarse sand ) with bricks of class designation 40 kgs / cm2. Above plinth upto floor V level 200 x 95 x 95 |
| 14 | Rubble packing with hard laterite stone under floors including watering ramming and consolidating etc. in pipeline trenches and other foundations complete. |
| 15 | SECTION -C CONCRETE WORKSProviding & laying cement concrete 1:2:4 (1 cement: 2 coarse sand: 4 graded granitic or basaltic stone aggrt. 20 mm. nominal size) excluding cost of centering, shuttering and finishing in retaining walls , return walls(any thk) including attached pilasters, columns, piers, abutments, pillars, posts, struts, buttresses, string or lacing courses, parapets, coping bed blocks, anchor blocks, plain window sills, fillets etc, upto floor five level. |
| 16 | Providing & laying cement concrete 1:2:4 (1 cement: 2coarse sand: 4 graded granitic or basaltic stone aggrt. 10 mm. nominal size) screedas per required thickness in floors upto floor five level excluding cost of centering, shuttering and finishing. |
| 17 | SECTION - D WOOD WORKProviding woodwork in frames of doors, windows, clerestory windows trusses & other frames wrought framed and fixed in positon. : Second class Indian teak wood |
| 18 | Providing & Fixing SS 304 grade Tower Bolts of size 300 x 10mm (barrel type) of approved make with necessary SS 304 grade screws etc.complete. |
| 19 | Providing & fixing Stainless Steel tubular lever D-Type mortise handles with round/Square nose, 24mm Mortise/sash lock body & Strike plate (all SS Finish), Pin cylinder 60mm with one side key and other side knob/thumb turn with necessary screws etc. complete |
| 20 | Providing and fixing Stainless steel 304 grade D type handles with necessary screws etc complete. a) L 300mm/325mm x 22 to 25mm dia |
| 21 | Providing and fixing ISI marked flush door shutters conforming to IS : 2202 (Part I) non-decorative type (BWP), core of block board construction with frame of 1 st class hard wood and well matched commercial 3 ply veneering with vertical grains or cross bands and face veneers on both faces of shutters: - 35 mm thick including ISI marked (304 grade) Stainless Steel 304 Grade butt hinges with necessary screws |
| 22 | Providing and fixing 1.00mm high pressure decorative Laminates (glossy/ matt) on wooden surfaces like doors, windows. The laminate should comprise of layers of specially selected paper, impregnated with melamine and phenolic resins pressed and hardened under heat and high pressure and should ensure strong bonding, resistance to boiling water and chemical and increase dimensional stablilty. Including cost of adhesive, nails during fixing etc. complete |
| 23 | SECTION - E STEEL AND ALUMINIUM WORKProviding and fixing of aluminium window with 3 tracks and 2 shutters sliding window with tobular frame ployster powder if thicness 75-80 microns with approved standard accessaries such as ball beaing rollers, concealed lock, 6mm thick plain clear glass with EPDM beading etc. |
| 24 | Steel work in built up tubular (round, square or rectangular hollow tubes etc.) (Square Hollow Section (SHS) IS4923/Rectangular Hollow Section (RHS) IS4923/Circular Hollow Section (CHS) IS1161 closed Structural Steel of (SAIL, TATA, VIZAG, JSW, APOLLO Steel Ltd.) make (Min Yeild Stress 310 Mpa)) trusses etc., including cutting, hoisting, fixing in position & applying a priming coat of approved steel primer, including welding & bolted with special shaped washers etc. complete |
| 25 | SECTION -F FLOORING AND FLOOR FINISHESProviding and fixing full body Anti skid vitrified tilesof 600 mm x 600 mm size (thickness to be specified by the manufacturer) of 1st quality confirmingto IS:15622 ofapproved make and shade for flooring at all levels with 3.00mm width spacer between tiles in both directions over cement mortar bedding 20 mm thick 1:4 (1 cement :4 coarse sand) with cement slurry @ 3.3 Kg/Sq.m andflooring finished in proper level and slope,including pointing the 5mm spacer joints for full depth of the tiles with Epoxy grout of approved make inmatching shade complete. an as directed by Engineer. |
| 26 | Providing and fixing full body 1st quality vitrifed wall tiles conforming to IS:15622 of approved make in all colours, shades with 3.00mm width spacer between tiles in both directions in skirting, risers of steps and dados over 12 mm thick bed of cement mortar 1:3 (1 cement : 3 coarse sand ) and jointing with grey cement slurry @3.3kg per sq.m including pointing the 5mm spacer joints for full depth of the tiles with Epoxy grout approved make inmatching shade complete. an as directed by Engineer.- Wall Glazed/Matt Tiles :1200mm X 600 mm |
| 27 | Providing and fixing rectified (Glossy / Matt finish ) vitrified tiles of specified size (thickness to be specified by the manufacturer) ofIst qualityskirting of 100 mm size at all levels flushed with plaster with 5mm width spacer between tiles in both directions over cement mortar backing coat 12mm thick 1:3 (1 cement :3 Coarse sand) or approved tile adhesive and jointed with grey cement slurry ,including pointing the 5mm spacer joints for full depth of the tiles with Epoxy grout of approved manufacturer inmatching shade complete. an as directed by Engineer. |
| 28 | Providing and and laying vitrified unglazed porcelain tactile floor tiles in different sizes of Johnson, Somany, Kajaria(thickness to be specified by the manufacturer) and conforming to IS:15622 of approvedmake in colours and shades as specified laid on 20 mm thick cement mortar 1:4 (1 Cement : 4 Coarse sand) including grouting the joints with white cement and matching pigment etc., complete |
| 29 | 300 x 300 mm Design - Liner |
| 30 | 300 x 300 mmDesign - Buttons |
| 31 | SECTION - G PLASTERING AND FINISHING WORK12mm cement plaster 1:4 (1 cement : 4 fine sand) |
| 32 | Applying one coat of distemper primer of approved brand and manufacture on wall surface. |
| 33 | Wall painting (one or more coats) with plastic emulsion paint of approved brand andmanufacture on old work to give an even shade. |
| 34 | Painting three or more coats with acryllic exterior paint of approved brand and manufacture including applying one coat of cement primer of approved brand and one coat of surface treatment on all types of plastered surfaces etc. complete. |
| 35 | Providing and applying white cement based putty of average thickness 1.00mm of approved brand and manufacturer, over the plastered wall surface to prepare the surface even and smooth complete. |
| 36 | Providing and applyingMatt finish scratch resistance Melamine polish on wood /veener work by sanding of wooden /veener surface first with 80 grit rough polish paper followed by sanding surface with 120 grit smooth polish paper followed by cleaning of sanded wooden /veener surface with dry cloth thereafter approved quality and make melamine sealer mixed with approved quality NC thinner in 1:5 to be sprayed/brushed to provide uniform coatthereafter sealer coat shall be allowed to dry for 12 hours.On drying the sealer coat, the surface is sanded with smooth water paper [150 or 200 No.] to remove the excess sealer layer and to make the surface further smooth. Further, approved Special filler pastes of required stains shall be filled in the small or large holes. After the filler dries in about 4 to 6 hours, light sanding with water paper shall be once again done & the surface shall be allowed to air dry for about 12 hours. Thereafter approved quality Melamine polish mixed with approved hardener is sprayed by a spray gun by a compressor.After the first coat of melamine polish is dried, that is after about 24 hours the surface is sanded thoroughly with smooth water paper of 220 grit & the surface is then allowed to air dry for about 12 hours.The final coat shall then be given by spraying melamine as in the first coat. The cost shall be inclusive of material, labour, scaffolding, transportaion etc all complete. |
| 37 | 18mm cement plaster in two coats under layer 12mm thick cement plaster 1:5 ( 1 cement : 5 coarse sand) and top layer 6mm thick with cement plaster 1: 3 (1 cement : 3 coarse sand) finished with sponge. |
| 38 | Removing dry or oil bound distemper by scrapping sand papering and preparing the surface smooth including necessary repairs to scratches etc. complete. |
| 39 | Painting (one or more coats) with synthetic enamel paint of approved brand and manufacture in all shades on old work to give an even shade. |
| 40 | 6mm cement plaster to ceiling 1: 4 (1 cement : 4 fine sand) |
| 41 | Painting (one or more coats) with black japan paint of approved brand and manufacture to give an even shade. |
| 42 | SECTION - H MISCELLANEOUS WORKSProviding anti – termite treatment to buildings conforming to I.S.S. 6113 part II 1971 (revised) including adoptingprecautions for health hazards and safety measures as required therein with the cost of all materials, chemicals, plants, equipments required for the treatment and furnishing a guarantee for a minimum period of 10 years from the date of completion including eradicatingany infestation of termite free of cost during the guaranty period complete. (The payment will be made on plinth of the building). (a) Post-construction |
| 43 | Providing and laying which is duel shrinkagecompensated, cementitious micro-concrete, high strength, high flow, single component cementitious formulation. The repair microconcrete shall have compressive strength minimum of 55 MPa at 7 day and 65 MPa at 28 days. The repair mortar shall not require polymer bonding agent as primer. All scaffolding, ladders, supporting materials etc. complete. Rates shall be inclusive of all labour, materials, tools and plant etc. complete. |
| 44 | Providing and fixing 120micron opaque film of approved makeon glass internal partitions and doors as per approved sample ,design ,drawing, specifications & direction of the Engineer/Architect with necessary glue, if required, labour,fixing in position etc.complete. |
| 45 | Providing & fixing in position sunscreen roller blinds ofapproved makeof approved color, shade of varying length, approved fabric with aluminum extruded rail powder coated in white. Control unit to be made of high strength reinforced plastic. Roller tube to be anodised extruded tube of high strength alloy, including all necessary fittings and fixtures like idler, head rail, control unit, roller tube, bottom rail, operating chain, fixing brackets, clamps, etc. complete.All works shall be completed as per the drawing/ Image, detailed technicalspecifications mentioned under VoL II and direction of the Engineer. |
| 46 | Supplyng and placing in position stainless steel dust bin (heavy) perforated of size 8\" diaand 12\" height |
| 47 | Providing and fixing in position approved make notice board made of aluminium frame workincluding 12 mm thick soft board with bleezer cloth to fixed in frame with clip fitting with all stainless steel hardwares making arrangement for fixing on wall complete as per drawing. |
| 48 | Providing and fixing signage made up of base materialof 6mm thick transparent/coloured acrylic sheet. The graphic is of computer cut self adhesive vinyl covered with clear vinyl to protect from peeling. The signage shall befixed with 12mm dia SS studs or ss mirror screws.All material shall be of approved make. All works shall be completed as per the drawing, specification and direction of the Engineer. |
| 49 | Providing and Fixing of Artwork on walls of Size 8ft high x 4ft wide in Digital Images Scanned and Printed in High resolution on UV resistant Vinyl pasted on 4mm Foam board/\"sunboard and mounted on a wooden frame of 3inches x 2 inches on all 4 sides of the artwork including Transport and Installation complete in all respects. |
| 50 | Providing and Fixing Wall mural tiles baked 6\"x 6\" Azulos tiles All works shall be completed as per the drawing, specification and direction of the Engineer. |
| 51 | Providing & fixing in position Galvalume/Zincalume flashings, cappings, ridges, gutters upto 600mm/610mm girth and min 3.00m in length (cold Rolled Steel 550 MPa yeild Stress ASTM A 446 Grade E) with hot-dip metallic coating of aluminium-zinc alloy(AZ 150 galvalume) (150 gms/sqm total of both sides with Al-Zn Composition= 55% & 43.5% resp. & 1.5% Si conforming to ASTM 792/ AS 1397) 0.45 mm base metal thickness and 0.50mm total coated thickness, factory cut at all heights for roof, side & gable cladding complete in all respects with AZ 150 GSM SMP color Coated (20mic exterior coat of Silicon Modified Polyester paint system over 5 mic primer and 5 mic polyester back coat over 5 mic primer) incl. fixing to purlins with no 12x14x55mm mechanically galvanised hex head self drilling screws of the best quality as per AS-3566 class 3-4 approved, which should be compatible to be used with sheets. with integral washers and EPDM seals etc. Silicon sealant non-hardening neutral cure type shall be applied at all end laps, complete as directed. |
| 52 | Providing & Fixing in position Double Skin roof with Zincalume/ Galvalume colour coated & bare profile sheet with subtle square fluting factory cut at all heights for roof, side & Gable cladding complete in all respect. TOP SHEET-The end rib shall be designed for anti-capillary action. The feed material should be manufactured out of nominal 0.45 mm Base Metal Thickness (BMT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 43.5% Zinc &1.5% Si) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides) with quality paint coat as per AS/NZS 2728 type 3-4. The paint shall have a total coating thickness of nominal 35 μm, comprising of nominal 20 μm exterior SMP coat on top surface and nominal 5 μm reverse backer coat on back surface over nominal 5 μm primer coat on both surfaces of approved colour shade. Total Coated Thickness (TCT) should be 0.50mm. Total Painted Thickness (TPT) should be in addition to 0.50mm. The steel sheet shall be fastened with nominal 40 μm zinc coated or nominal 25 μm zinc-tin alloy coated, Hex head, self-drilling screw as per AS 3566-2002 Class 3 fasteners of approved make with EPDM washer as per the requirement considering the profile shape and design load. The fastener size shall be calculated as per the design or manufacturers recommendations. |
| 53 | The profile sheet, fastener size etc. shall be approved by the Engineer. The sheeting should be with minimum 200mm lap & waterproof with Silicon sealant non-hardening neutral cure type shall be applied at all end laps, complete as directedZ-Sub Girt - roll formed section 50x50x50x1.50 TCT, 120GSM Galvanised, High Strength (345 MPa), approximate Wt. 1.85 kg/r.m. fixed with self tapping screws Glass Wool Insulation with FSK facing 50mm with 24 kg/m3 density in between 2 sheets. LINER SHEET-bare galvalume/zincalume roofing sheet of same profile as top sheet. The feed material is of manufactured out of nominal 0.45 mm Base Metal Thickness (BMT) (0.47 mm TCT), Hi-strength steel with min. 550 MPa yield strength, metallic hot dip coated with Aluminium-Zinc alloy (55% Aluminium, 45% Zinc) as per AS 1397 - Zincalume AZ150 (Min. 150 gms/sq.mt total on both sides), passivated & resin coated. The feed material should have coil manufacturer’s product details marked at regular interval for confirming genuinity of the material. complete as per the directions of the engineer.The steel manufacturer\"s test certificate for the chemical & mechanical properties of steel must be submitted for approval prior to installation. |
| 54 | Supplying and Laying Mangalore roof tiles ( 2 nd class ) roofing tiles, ridges, valleys etc. complete on roofs over existing battens rafters etc. |
| 55 | Supplying and fixing glasspanes with putty and nails includingremoval of broken glass panes wherever necessary - Glass panes 3mm thick |
| 56 | SECTION - I PARTITIONSProviding and Fixing of Partition for the Conference space with end panels on both sides fixed, middle panels 2 nos on both sides sliding to rest behind fixed panel on wall when opened.MS TUBE 150mm x 75mm x 4mm to be used to support the sliding partitions from the walls/ ceiling and covered with 12mm plywood panelling with supports in 19mm Plywood at intervals of 3ft finished with 1mm llthick wood look laminate as per engineer\"s choice.Sliding panels made in 35mm thick flush door base and6mm marine plywood border ( 6 inches) on both sides with combination of Wood look laminate in 6 inch border and Rattan look laminate in the middle panel as per engineer\"s choice, with necessary Sliding hardware, door concealedhandles, etc in Ebco or equivalent make complete in all respects |
| 57 | SECTION -J READYMADE FURNITURESSupplying and placing in position Meta Bench Straight Bench - 1200mm x 2 qtyTurning Bench - 720 x 720mm x1 qtyDepth of Bench 600mm* Made of 15 mm & 8mm Thick Plywood.* 30 mm Thick Plywood Battens.* Legs in Metal* PU Seat Foam : Density - 40 kg/m3, Thickness - 60 mm*Side Foam : Density - 28 kg/m3,Thickness - 6 mm Writing Shelf x 1 qty (350W, 560D)* Made of 19 mm Thick MDF* Painted: WH-White *19 OD X1.5mm THICK STAINLESS STEEL PIPE (304 GRADE) |
| 58 | Supplying and placing in position Forum Pouf 430mm HT 470mm DIA* Made of 15 mm Thick Plywood, Wooden Battens & Flexi Ply.* PU Seat Foam Density - 40kg/m3 Thickness - 100 mm |
| 59 | Supplying and placing in position For Newspaper Reading Table Model : Ice Specifications Monolithic design Back finish : Plastic ShellSeat finish : Plastic shell Base : Nylon 4 legged Stackable: Upto 5 on the floor Warranty : 3 years from date of Invoice |
| 60 | Supplying and placing in position Gale MB chairOverall Height - 950 - 1050mmOverall Width - 620mmOveral Depth - 680mmSeat Height - 495 - 595mmSeat Width - 510mmSeat Depth - 510mmFrame Material - NylonBack Height - Medium BackBack Finish - Mesh with Adjustable lumber supportBackMesh - Polyster MeshSeat Fabric - Polyster with PU FoamSeat Height Adjustable with gas LiftMechanism Type - Synchronized Tilt Back Lock - Upright positionBack Tilt Tension - Adjustable via KnobArmrests Type - Fix arms in PolypropeleneBase Type - Nylon 5-Star BaseCastors - 50mm hoodedGreenguard Certified for Low Chemical EmissionWARRANTY: 3 Years from the date of invoice |
| 61 | Supplying and placing in position18mm Thick Prelam Top 550mm Dia Prelam Top450mm Ht Overall Height Star Base - Powder Coated Legs |
| 62 | Supplying and placing in position Linear WSSystem Legaue plusTable top : 25mm thick Prelam particle board finish with Prelam particle board finish with pvc edge Liping and worktop height 745mm from ground level.Electrical : Metal powdercoated HNI access flap (300mm) above the worktop for electrical access, metal powdercoated electrical panel below worktop to carry cables through it.Legs : Metal powdercoated League Plus 50x50Square Open legs to support the worktop.Front Modesty Panel : Metal powdercoated front modesty panels of 300mm H with Square slots. Size : LINEAR WS 900mm X 600mm D X 745 HT |
| 63 | Supplying and placing in position Prelam Pedestal : 3 drawer Pedestal ( 2D+1FD ) OSL Prelam Particle board pedestal on castors with Side Chamfer side edge , central locking, 18 thick back (Size: 400W X 450D X 621H) |
| 64 | Supplying and placing in position ISSUE COUNTER TABLE - RECEPTION TABLE -OPTION 2 Trent Reception table 1800 l X 475 d X 1185 ht Work top thickness is 25mm in Prelam particle board with wire manager hole 25mm thick particle board Gable ends with PVC edge lipping. 18mm thick particle boar d Front panel with PVC edge lipping. 25mm prelam particle board top.18mm thick particle board Modesty panel with PVC edge lipping. Prelam particle board Lockable drawer on one sideSide Combo Storage : One Openable doors + 2 Drawer+ 1Filling Drawer OSL Prelam Particle board combo storage with pvc edge Lipping on leveler and 18 Thick Back, Chamfer , Handle central locking (Size: 900W X 450D X745H) |
| 65 | Supplying and placing in position NEWS PAPER READING TABLEMeeting Table Size : 1600L X 1100 DX 745 HTTable Top :25 mm Thk. Prelam Table Top With 2 mm Thk. Flat Edge PVC Lipping. & Worktop height 745 mm from ground level .End Leg : Metal Powder Coated Avail Curved leg.Electrical :N/A |
| 66 | Supplying and placing in position D SHAPE MEETING TABLEMeeting Table Size : 1800L X 1200 DX 745 HT (WITH 1 ACCESS FLAP )Table Top :25 mm Thk. Prelam Table Top With 2 mm Thk. Flat Edge PVC Lipping. & Worktop height 745 mm from ground level .End Leg : Metal powdercoated League Plus 50x50Square Open legs & Metal powder coated pole understructure to support the worktop.Electrical :Metal Powdercoted HNI access flap 450mm above the worktop for electrical, metal powdercoated Vertical duct for wire travel from ground. |
| 67 | Supplying and placing in position METAL LIBRARY BOOK STORAGESize : 900 X 450 X 2185 HTERIC METAL CABINET WITH GLASS DOOR 900X450 X1660HT+ 525 HT ADDON Unit . Total height become 1660+525 = 2185ht |
| 68 | Supplying and placing in position PRELAM LIBRARY STORAGE18mm Thk Prelam Book Shelf Storage With Skirting SIZE 900 X 450 X 2100 HT |
| 69 | Supplying and placing in positionstorages OSL prelam Particle board storages with straight PVC Lipping on levellar and 18 Thick Back, Top chamfer handle , central locking |
| 70 | SIZE : 900 L X 450 D X 1800 HT |
| 71 | SIZE : 900 L X 450 D X 1200 HT |
| 72 | SECTION K ELECTRICAL WORKPOINT WIRINGWiring for light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy) with modular switch, modular plates,suitable size modular GI box of specified Category and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 73 | Group C-- with Cat A Modular Accessories |
| 74 | Wiring for group controlled light point/ fan point/ exhaust fan point/ call bell point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable in recessed PVC conduit(heavy)and earthing the point with 1.5 sq.mm FRLS PVC insulated copper conductor single core cable etc. as required. |
| 75 | Supplying and fixing suitable size modular GI box with modular plate and coverin front on surface or in recess including providing and fixing 3 pin 5/6 Amodular socket outlet and5/ 6 Amodular switch connection painting etc. as required. Cat A |
| 76 | Supplying and fixing suitable size modular GI box with modular plate and coverin front on surface or in recess including providing and fixing 6 pin 15/16 A and 5/6 A modular socket outlet modular socket outlet and15/16 Amodular switch connection painting etc as required. Cat A |
| 77 | Supplying and fixing 20 A 240 V SPN industrial type socket outlet with 2 pole and earth metal enclosed plug top alon with 20 A, C seriesSP MCB in sheet steel enclosure in surface or in recess with chained metal cover for the socket outlet and complete with connections testing and commissioning etc. as required\" Cat A |
| 78 | CIRCUIT WIRINGWiring for circuit/ submain wiring alongwith earth wire with the following sizes of FRLS PVC insulated copper conductor single core cable in the independent recessed PVC conduit(heavy) of appropriate size as required. |
| 79 | 2 x 2.5 sq.mm + 1 x 2.5 sq.mm earthwire (20mm Conduit) |
| 80 | 2 x 4 sq.mm + 1 x 4 sq.mm earthwire (20mm Conduit) |
| 81 | 2 x 6 sq.mm + 1 x 6 sq.mm earthwire (25mm Conduit) |
| 82 | 4 x 6 sq.mm + 2 x 6 sq.mm earthwire (32mm Conduit) |
| 83 | 4 x 10 sq.mm + 2 x 10 sq.mm earthwire (32mm Conduit) |
| 84 | DBs, MCBs, RCCBs etc.Supplying and fixing following way TPN sheet steel, double door, Horizontal type MCB distribution board 415 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)8 way (8+24), double door, Horizontal type Cat B |
| 85 | Supplying and fixing following way SPN sheet steel MCB distribution board 240 V on surface/ recess complete with tinned copper busbar neutral busbar earth bar dinnbar detachable gland plate interconnections phosphotized and powder painted including earthing etc. as required ( but without MCB/RCCB/Isolator)(j) 8 way single door Cat B |
| 86 | Supplying and fixing 6 A to 32 A,C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required. |
| 87 | SP, Cat B |
| 88 | DP, Cat B |
| 89 | Supplying and fixing 40 A,C series MCB suitable for lighting and other loads of following poles in the existing MCB DB complete with connections testing and commissioning etc as required.(i) TP, Cat B |
| 90 | Supplying and fixing following rating double pole (single pole and neutral) 240 V RCCB having a sensitivity current upto 300mA inthe existing MCB DB complete with connections testing and commissioning etc as required |
| 91 | 25 A, Cat B |
| 92 | 40A ,Cat B |
| 93 | LIGHT FITTING Supply, installation, testing and commissioning of 36W, 5700 K ,1200mm Linear recessed luminaire, housing made of extruded aluminium with a satin finish PMMA diffuser for standalone and seamless end to end connectivity inclusive of all accessories. |
| 94 | Supply and erecting of 48 inch (1200mm sweep) ceiling fan, double ball bearing type, , complete with all accessories.(b) Cat B |
| 95 | Supply and erecting meter box suitable for three phase energy meter and incoming SP/DP MCB, fabricated out of 16 SWG sheet steel, powder coated, complete as required and conforming to the requirements of Goa Electricity Department. |
| 96 | Supply, installation, testing and commissioning of electronic type three phase energy meter (KWh), 4 wire, ISI marked, in polycarbonate or sgheet steel body ( base mounting type) with counter display/LCD display, with ELT, in Class 1.0, 50 Hz, 240 V. AC duly tested by MRT along with Test Certificates, complete as required of following capacity of make L & T only.(b) 10 to 40 A |
| 97 | Supplying and fixing stepped type electronic fan regulator on the existing modularplate switch box including connections but excluding modular plate etc. as required(b) Cat B |
| 98 | EARTHINGSupply and providingChemical earthing system (Pipe in pipe type)withOuter pipe of the electrode having minimum 50mm diameter as per the enclosed specifiations and drawing.The outer and the inner hot dip galvanised MS pipes shall conform to the specifications and the space inbetween shall be filled withhighly crystalline conductiveand anti- corrosive mixture conforming to IS-3043. The earth electrode shall be CPRI tested. The scope of work includes boring( 300mm dia mimnimum)/exvavation of soil/hard rock, refilling with required quantity of back fill compound/Ground resistance enhancement powder of requisite quantity, compaction, constuction of masonary chamber etc complete as required to obtain the desired value. Aluminium tag with embossed earthing value shall be permanently attached to the pipe electrode 3 metres length electrode |
| 99 | Supply of Back fill Compound/ Groung resistance enhancement powder conforming to the enclosed specifications. |
| 100 | Providing and fixing 25 mm x 5 mm GI strip on surface or in recess for coneections etc. as required |
| 101 | Supplying and laying 25 mmx 5 mm GI strip at 0.5 m below ground as strip earth electrode including soldering etc. as required |
| 102 | LANWiringSupplying and fixing of following sizes of rigid PVC conduit alongwith accessories in surface(medium)/recess(heavy) includingcutting the wall and making good the same in case of recessed conduit as required.(a) 20 mm |
| 103 | Supplying, installation and testing of suitable size modular GI box , modular plate and cover complete with RJ-45 connector(modular LAN socket TX1000/ CAT6) including concealed metal box/surface GI/PVC Box, modular plate, punching, identifying, complete as required. CAT A |
| 104 | Supplying and fixing Cat 6, 24 port patch panel with keystone jacks compliant with ANSI/TIA/EIA 568.C.2 & ISO/IEC 11810 complete as per specification no. WG-NAS/PP |
| 105 | Supplying and fixing 3 m 24 AWG multi stranded UTP patch cord with RJ-45 factory crimped connector of cat 6 type compliant ANSI/TIA-568.2-D standards in position as per specification no.WG-ELVC/PC |
| 106 | Supplying and drawing of Cat - 6 UTP, 4 pair annealed tinned copper conductor PVC insulated, PVC sheathed, unarmoured data cable in existing surface/recessed steel/PVC conduit of appropriate size including connection, etc. complete as required Cat 6 |
| 107 | Supplying, erecting & terminating 10 m HDMI cord low voltage grade minimum 4k compliant to be laid in provided conduits with male/female 19pin HDMI connectors complete. |
| 108 | Supplying, fixing, and configuring 24 Ports + 4 SFP combo, layer 2, GB managed ethernet switch, with web view compliant with IEEE 802.3 standards erected in provided rack complete |
| 109 | FIRE EXTINGUISHERSSupplying & erecting Carbon Dioxide (CO2) fire extinguisher of 4.5 kg. capacity cartridge type conform to IS 2878 /15683 complete erected with ecessary clamp made from 50 x 6 mm. M. S. flat with nut & bolts routed in wall complete. |
| 110 | INVERTERSupplying, installing, testing and commissioning of single phase, 230V, 50 Hz,1400 to 1600VA digital pure sine wave inverter with backup time of 1. hrs.based on Insulated Gate Bipolar Transistor (IGBT) technology complete as per specification no. AP-INV |
| 111 | Supplying and erecting 12 V/180Ah Tubular battery with battery terminal wire, duly charged complete with 36 months warranty complet |
| 112 | DismantlingDismantling the existing light, fan, bell, clock, independent plug point, wiring including circuit mains of all types along with accessories etc.complete as per specification No: WG-DM/PW |
| 113 | Dismantling the existing Telephone / Lan / Wan / TV cables and wires of all sizes along with casing-capping / conduit complete as per specification No: WG-DM/PW |
| 114 | Dismantling the existing Aluminium/copper mains,submains wiring upto 10 sq.mm. along with accessories etc.Complete as per specification No: WG-DM/PW |
| 115 | Dismantling the existing W.T. fluorescent fitting / S.V./ M.V. / M.H. lamp /LED fitting from wall with brackets and making the site as original complete. |
| 116 | AIRCONDITIONERSSupplying, installing, testing & commissioning split type variable speed inverter technology with minimum 3 to 1 convertible mode for compressor, room air conditioning unit 1.3TR to 1.6TR capacity having ISEER minimum 3.8 tomaximum 4.39 suitable to operate on 250V, 50 Hz, A.C. supply having 1 no of air handling unit hi-wall/floor mounting type complete with refrigerant R32having copper condenser, minimum 2.5PM filter, self diagnosis feature, stabilizer free operation & temperature display on indoor unit, noise level maximum 50dBA at position as per specification no. APAC/ WAC |
| 117 | SECTION L WATER SUPPLY,SEWERAGE,PLUMBING AND SANITATION WORKSProviding and & fixing white vitreous china wash basin including making all connection but excluding the cost of fittings :Flat back wash basin of size 550 x 400 mm |
| 118 | Proving and fixing white vitreous china Wall Hung type (European Type) water closet with seat and lid with C.I. brass hinges and rubber fittings with flush valve nelson/ similar fully chromium plated with stop cock, wall flanges, flush pipe or elbow and vaccum breaker coupling etc. including chair bracket/rag bolts, cutting & making good the walls and floors where required and concealed seat support - W.C. Pan with white plastic seat and lid |
| 119 | Providing and fixing NICKEL chrome plated copper alloy Fancy concealed stop cock with slinding flance 15 mm Jaquar make or equivalent. Confirming to IS 8931;1993 15mm nominal bore |
| 120 | Providing and fixing NICKEL chrome plated copper alloy Fancy Pillar Cock rocket type Jaquar make or equivalent. Confirming to IS 8931;1993 15mm nominal bore |
| 121 | Providing and fixing Hand Shower (Health Faucet) with 8mm dia, ABS/brass body with double lock 1.00m long Flexible tube (Brass plated stainles steel flexible hose) and wall hook of approved quality confirming to IS standards. |
| 122 | Providing and fixing toilet paper holder : C.P. Brass |
| 123 | Providing and fixing P.V.C. connection pipe with brass unions 15 mm nominal bore:45 cm (18”) length . |
| 124 | Providing and fixing 600 x 450 mm bevelled edge mirror of superior glass (of approved quality) complete with 6 mm thick asbestos sheet ground fixed to wooden cleats with C. P. brass screws and washers. |
| 125 | Providing & fixing liquid soap container with C. P. brass lid and brackets fixed to wooden cleats with C. P. brass screwsGlass container |
| 126 | Providing and placing on terrace roof of floor two (1st flor roof single piece rotational moulded polythene water storage tank having I S I mark and conforming to I S 12701; 1996.500 lit. capacity |
| 127 | Providing and fixing square-mouth S.W. gully trap grade ‘A’ complete with C.I. grating brick masonry chamber and water tight C.I. cover with frame of 300 x 300 mm size (inside the weight of cover to be not less than 4.53 kg). And frame to be not less than 2.72 kg as per standard design :150 x 100 mm size –P or S type |
| 128 | Constructing brick masonry manhole or inspection chamber with second class bricks in cement mortar 1:5 (1 cement :5 fine sand) R.C.C. top slab with 1:2:4 mix (1 cement: 2 coarse sand ;4 graded stone aggregate 20mm nominal size foundation concrete 1:2:4 mix (1 cement ;2 coarse sand :4 graded stone aggregate 40mm nominal size) inside plastering 12 mm thick with cement mortar 1:3 (1 cement :3 coarse sand) finished with a floating coat of neat cement and making channels in cement concrete 1:2:4 mix (1 cement :2 coarse sand :4 graded stone aggregate 20 mm nominal size) neatly finished complete as per standard design. Inside size 60 x 60cm and 60cm deep including C.I. cover with frame (light duty) 455x610mm internal diameter total weight of cover and frame to be not less than 38 kg. (weight of cover 23 kg). |
| 129 | Providing and fixing rigid PVC S.W.R. (soil, waste & rain water drainage pipes ofapproved including lubricant etc. complete (single/double) socketed: |
| 130 | 110 mm dia |
| 131 | 75 mm dia |
| 132 | Providing and fixing rigid PVC bend of required degree (of approved make) for S.W.R. drainage pipes of approved including lubricating.75 mm dia |
| 133 | Providing and fixing single “Y” of rigid PVC (approved make) for S.W.R. pipes including lubricating etc complete, with door :75 mm dia |
| 134 | Providing and fixingstainless steel cockroach trap with grating, 150X 150 mm of (Approved brand and make) including sealing of edges with white cement and accessories etc. complete as per the direction of engineer. |
| 135 | Providing and fixing nahani trap ofrigid PVC (approved make ) for S.W.R. pipes including lubricating etc complete, without door :110 mm dia |
| 136 | Providing and fixing Brass metal ball valves half turn of approved quality and make etc. complete. with pressure rating up to 20 bars.40mm Nominal bore |
| 137 | Fixingwater meter & stop cock in G. I. Pipe line including cutting & treading the pipe and making long screw etc. complete (cost of water meter and stop cock to be paid separately) |
| 138 | Constructing soak pit 1.20m x 1.20m x1.20m filled with laterite stone aggregate 125 to 180 mm including S.W. drain pipe 100 mm diameter and 1.2m. long complete as per standard design. : |
| 139 | Providing and fixing NICKEL chrome plated copper alloy Fancy BIB Cock Short Body Jaquar make or equivalent. Confirming to IS 8931;1993 |
| 140 | Providing and fixing chlorinated ployvinyl chloride (CPVC) pipes confirming to IS:15778, having thermal stability for hot and cold water supply including all CPVC plain and brass threaded fittings including fixing the pipes with clamps at 1 mt. spacing.This includes jointing of pipes and fittings with one step CPVC solvent cement and testing of joints complete as per direction of the Engineer-in-charge. Concealed work (medium duty SDR 13.5 pipe) including cutting chases and making good the walls etc. |
| 141 | 15 mm dia nominal outer dia pipes. |
| 142 | 20 mm dia nominal outer dia pipes. |
| 143 | 25 mm dia nominal outer dia pipes. |
| 144 | 32 mm dia nominal outer dia pipes. |