}

Operation And Maintenance Of Firefighting Pumping Machinery Including Jockey Pump Arrangement At Ganga Sagar Main Mela Ground, Kachuberia With Buffer Zones , Chemaguri , Benuban And Lot8,Kakdwip In Connection With Ganga Sagar Mela 2025, sagar-West Bengal

Public Health Engineering Department has published Operation And Maintenance Of Firefighting Pumping Machinery Including Jockey Pump Arrangement At Ganga Sagar Main Mela Ground, Kachuberia With Buffer Zones , Chemaguri , Benuban And Lot8,Kakdwip In Connection With Ganga Sagar Mela 2025. Submission Date for this Tender is 02-11-2024. Vehicle Hiring Service Tenders in sagar West Bengal. Bidders can get complete Tender details and download the document.




Tender Notice

45766995
Operation And Maintenance Of Firefighting Pumping Machinery Including Jockey Pump Arrangement At Ganga Sagar Main Mela Ground, Kachuberia With Buffer Zones , Chemaguri , Benuban And Lot8,Kakdwip In Connection With Ganga Sagar Mela 2025
Tender
Indian
West Bengal
Sagar
02-11-2024

Tender Details

Operation And Maintenance Of Firefighting Pumping Machinery Including Jockey Pump Arrangement At Ganga Sagar Main Mela Ground, Kachuberia With Buffer Zones , Chemaguri , Benuban And Lot8,Kakdwip In Connection With Ganga Sagar Mela 2025-2 Hiring ofgoods vehicle Tata Ace/ equivalent for carrying of 25 KVA Diesel Generator set from one firefighting station to another on 24 hours basis including driver and fuel for the vehicle from 25-12-2024 to 31-12-2024 3 Loading of the 25 KVA DG set by arranging necessary tools and tackles in vehicle and unloading the same after 31-12-2024 as per direction. 4 Running and maintenance of engine driven generator set by supply of fuel, lubricant and skilled operating personnel during running period as necessary as per direction of EIC for commissioning of the firefighting Jockey pump systemfrom 25-12-2024 to 31-12-2024= 7 days x 20 KW x 9 Hrs 5 Carrying the 83 BHP firefighting engine withpumps from store to working station including dismantling of wheels from the trolley and installation the same by anti vibration pads on the existing trolley including fitting fixing all suction and delivery pipe line by pass line, valve etc as per existing drawing including supply of bolts, washer and gasket with proper pipe support etc complete as per direction of EIC 6 At sagar Main Mela Ground 7 At Kachuberia 8 At Chemaguri 9 At Benuban 10 Carrying of Jockey pump motor set with all its accessories from store to working station including installation the same by anti vibration pads on the existing base at working station including fitting fixing of all suction and delivery pipe line by pass line, valve, pressure switches, pressure gauges etc including supply of bolts, washer and gasket with proper pipe support etc and testing complete as per direction of EICand up to the entire satisfaction of EIC 11 a.At Sagar Main Mela Ground 12 b. At Kachuberia 13 c. At Chemaguri 14 At Mandirtala Netaji Pathagar Buffer Zone 15 At Chak Fuldubi Gandhi Smriti Buffer Zone 16 At LOT8 ,Kakdwip 17 d. At Benuban 18 Providing one operator and one labour on 24hrs basis at site for valve operations of main pump and jockey pump as per instruction for the period from 02.01. 2025 to 16.01.2025. This includes the cost of tools and plants on hire basis (18 Stations) 19 Providing, one supervisor, two technicians and two labour on 24hrs basis at site for attending main operational defects etc if any in jockey pump to maintain predefined continuous line presure as per instruction for the period from 02.01. 2025 to 16.01.2025. This includes the cost of tools and plants on hire basis 20 Running and maintenance of 83 BHP [66.4Kw] diesel engine driven pump set with supply of fuel &lubricants etc. with effect from 02.01.2025 to 16.01.2025 = 15 daysx 66.4 Kw x 2 Hr. x 18 stations 21 Carrying of the float valve assembly with all its accessories from store to work site andfitting fixing of the float valve at water inlet of firefighting tank complete with supply ofnuts, bolts & washers, gaskets all complete with testing at each fire tank station as per direction and up to the entire satisfaction of the EIC. (18 Stations) 22 Painting the suction delivery, by pass line including valves, chassis by approved brand and make paint with a coat of primer as direction. (Shade and brand will be approved by the EIC) for main pump 23 Painting the suction delivery, by pass line including valves, chassis by approved brand and make paint with a coat of primer as direction. (Shade and brand will be approved by the EIC) for Jockey pump pump (18 no. station) 24 Supply and delivery of bleaching power with 33% free chlorine in 25 Kgpoly bagfor disinfection [Make:DCM/Kanoria] 25 Drawing of halogen light point on salbollah post from generating station on hire basis at fire fighting spot at different places at main mela ground with the supply of 1000 watt halogen lamp and fixture including 7/20 PVC flexible wire for wiring and all other required materials complete (damage materials will have to be replaced by the agency at their own cost) with effect from02.01.2025 to 16.01.2025 = 15 daysx 18 stations x 2 Nos= 420 pts [2nos halogen in each station] 26 Carrying back the main pump and engine with all its accessories after dismantling the installation including loading unloading complete and hand over the same at departmental store and covering with polythene paper properly 27 At Sagar Main Mela Ground 28 At Kachuberia 29 At Chemaguri 30 At Benuban 31 Carrying back the jockey pump motor sets with all its accessories after dismantling the installation including loading unloading complete and hand over the same at departmental store and covering with polythene paper properly Island 32 a.At Sagar Main Mela Ground 33 b. At Kachuberia 34 c. At Chemaguri 35 d. At Benuban 36 At Mandirtala Netaji Pathagar Buffer Zone 37 AtChak Fuldubi Gandhi Smriti Buffer Zone 38 At LOT8 ,Kakdwip 39 Providing Jockey Pump for fire fighting ststem FOR 2 Nos. Buffer Zone (Pakhirala-Vivekananda High School &Harinbari) in connection Ganga Sagar Mela 2025 40 Supply, delivery & storage at site centrifugal pump for use as Jockey Pump for firefighting system, complete with coupling, coupling guard, common base frame for pump motor set (skid mounting) having the following duty parameters:-Capacity : 11.0 Cum/Hr.Generated Head : 75 MWCSpeed : 3000 rpm (Syn) max.Duty : On/off service as Jockey PumpType : End suction top delivery/radically split multi stage.MOC : Casing : IS 210 FG 260Impeller : BronzeShaft : SS 410Installation : Outdoor, temporaryPumping Fluid : Clear water at ambient temperature.The Pump should be positive suction, shaft sleeve: SS 410,Wear ring : Bronze, Casing : CI IS 210 FG 260[Make: Flowmore/M&P/WPIL/KBL] (Two Sets in One Station)TC of pump needed. Riverine charges @5% included. 41 Supply, delivery and storage at site horizontal floor mounted squirrel cage induction motor of suitable rating for the above pump for Jockey application.The motor will be installed on the pump motor skid and shall have auto start/stop based on procure sensing as described in the operating philosophy.Motor rating to have minimum 25% margin over duty point BKW of the pump. The motor should be IE-3, IP-55 (W), IS: 12615, 11KW 415V, 50Hz., ±5%, Class-F, 2 Pole, TEFC, 500C. [Make: ABB/Marathon/CGL/Siemens](Two Nos. in One Station)TC of motor needed. Riverine charges @5% included. 42 Supply, delivery and storage at site free standing, outdoor type portable MCC cum Control Panel for the Jockey Pumps to perform as applicable. The pump shall have star-delta starter and have auto operation based on header pressure. There shall be signal communication between this panel and panel for fire pump for auto starting of the fire pump with alarm. The panel should have one no. spare starter, fuse less PDB & MCB/MCCB, DOL starter with Type-2 contactor, 80 Micron Epoxy painted, FRLS wiring, MPCB/MCCB/MCB needed, power contactor Siemens/ABB, IS: 8623, IP-65 preferred. TC of Panel needed. Reverine Charges @ 5% included. 43 Supply, delivery & storage at site necessary 3M pressure switches and two nos. pressure gauges with isolation valve and depressurization valve with required impulse tubes for auto operation of fire pump and Jockey Pumps and 3 Nos. 10000Ltrs. Tank for each Station. Riverine Charges @5% included. 44 Supply,delivery and storageof follwing electrical accessories at site as per sample:- 45 1.1KV grade, 3.5C, 35 sq. mm XLPE insulated AL AR cable confirming to IS: 7098 (Pt-II) with latest amendment for Incomer Panel. [Make: Gloster/Polycab/Crstal]. TC of cable needed. Reverine charges @5% included. 46 1.1KV grade, 3C, 2 x 16 sq. mm XLPE insulated AL AR cable confirming to IS: 7098 (Pt-II) with latest amendment for Panel to Jockey Pump. [Make: Gloster/Polycab/Crstal]. TC of cable needed. Reverine charges @5% included. 47 1.1KV grade, 10C, 2.5 sq. mm XLPE insulated CU AR control cable . [Make: Gloster/Polycab/Crstal]. TC of cable needed. Reverine charges @5% included. 48 Supply, delivery and storage at site of DN 50 mm MS ERW medium pipes with bends & other fittings required for connecting the Jockey Pumps in the system including supply of DN 50 mm, NRV & Gate Valves. [Make: Durga/IVC/KVL]. TC of valve needed. Reverine charges @5% included. 49 Providing one 3M x 4M concrete base on brick soling for installation of Jockey Pump Motor set and the MCC cum Control Panel. 50 Erection, testing and commissioning of the system as per IS: 15301 including modification of existing fire engine control panel (For Automatic Starting), all cabling, piping etc to the entire satisfaction of the EIC. 51 Rectification Work - 52 Repairing the 6 Nos. Float and 14 Nos. Float Valves and servicing of the each, oiling after cleaning and testing all complete to the entire satisfaction of the EIC. 53 Repairing of 83 BHP engine for Fire Pumpincludes replacements of Hose and repairs of Radiators and Nozzle repair all complete as per direction and to the entire satisfaction of the EIX complete with Testing. 54 Supply of Solenoid Valve for Fire Engine 83 BHP Model 3YDC, Greaves make as per sample. 55 Supply of Turbo Mobil Pipe for 83 BHP Model 4G11T Greaves Engine as per sample. 56 Making of new brick foundation of sizes 4M x 3M x 150 mm- thick + 1.5M x 700mm x 200mm -height for Jockey Pumps (1)Point - Fire Station (2) 9 No. Bus Stand Point - Fire Station (3) 4 No. Point - Fire Station (4) 8 No. Point - Fire Station. Cost includes earth cutting, sand filling, brick flat soling, CC Foundation, plastering and net cementing all complete. 57 Making new foundation of size RCC for engine 4.5M x 4M x 200 mm thick, 8mm dia TMT bar used at Fire Station. The cost includes earth cutting, sand filling, brick flat soling, Rod binding, shuttering, RCC, plastering and net cementing & finishing complete. 58 Dismantling and taking out all the spares from existing MCC cum Logic control Panel by engaging skilled technician and unskilled labour as per direction. Painting of the panel both inside and outside with epoxy based paint using powder coating method after preparation of the surface as per direction of EIC. Servicing and repairing of the panel board with necessary fabrication work as per direction. Fitting fixing of the dismantled spare in existing position by skilled technician and inetrnal wiring complete which includes supply necessary hardware materials to complete the work. 59 Painting of Engine with pumps, Jockey pump motor set at site which includes cleaning and scrapping the surface by emery paper, smoothening the surface, apply of primer in two coats, surafacing all complete then application of synthetic enamel paint as per approved colour by spray machine, roller etc. as per direction of EIC 60 Fire pump with Engine 61 Jockey pump motor set 62 Charges for through cheking and inspection of 18 Nos. fire fightingcontrol panel at site by expert technician all complete as per direction 63 Dismentling and taken out all defective materials from the control panelsby expert technician all complete as per direction 64 Supply and delivery of following materials at site - 65 A] 22 Amps 3 phase Air break contactor ; Make Siemens(3TF-3300-0A0/any other approved make of similar spec ( Rate is inclusive of riverine charge @5.0%) 66 B] 2.5 mm Terminal connector; Make-Elmex(Rate is inclusive of riverine charge @5.0%) 67 C] 10 A 3P 2way selector switch ; Make -KAYCEE (3S36BO) ( Rate is inclusive of riverine charge @5.0%) 68 D] 2.5 sqmm pvc insulated FRLS stranded copper wire ; Make Any approved vendor of PHED( Rate is inclusive of riverine charge @5.0%) 69 E] Hardware ( Lugs , sockets , ferrules, cable tie etc) 70 Fitting-fixing of the above materials with all electrical connections complete as per direction

Key Value

Document Fees
Refer document
EMD
INR 156100.0 /-
Tender Value
Refer document
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail