}

Tender For Installation Of Electric Pole In Ward No.2 And 5 In Dhule Municipal Corporation Area. (Excluding Solar, Led Bulbs, Solar High Mast) - Part A Rolled Steel Joist (Girder) Pole 2 Providing Pipe Type Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Di, Dhule-Maharashtra

Dhule Municipal Corporation has published Tender For Installation Of Electric Pole In Ward No.2 And 5 In Dhule Municipal Corporation Area. (Excluding Solar, Led Bulbs, Solar High Mast) - Part A Rolled Steel Joist (Girder) Pole 2 Providing Pipe Type Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Di. Submission Date for this Tender is 17-10-2024. Packaging Tubes and Label Tenders in Dhule Maharashtra. Bidders can get complete Tender details and download the document.




Tender Notice

45731274
Tender For Installation Of Electric Pole In Ward No.2 And 5 In Dhule Municipal Corporation Area. (Excluding Solar, Led Bulbs, Solar High Mast) - Part A Rolled Steel Joist (Girder) Pole 2 Providing Pipe Type Earthing With 40Mm. Dia. G.I. Pipe Or 20 Mm Di
Open Tender
Indian
Maharashtra
Dhule
17-10-2024

Tender Details

Installation of electric pole in Ward No.2 and 5 in Dhule Municipal Corporation area. (Excluding Solar, LED Bulbs, Solar High Mast) - Part A rolled steel joist (girder) pole 2 Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP (9-1-4) 3 Making cement concrete foundation including excavation (60 x 60 x 150) cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45) cm /45cm dia. x 45 cm height plinth duly plastered, with necessary curing and finishing complete. (above 6 m to 9 m poles) 4 Supplying and erecting rolled steel joist (girder) pole 125 x 70 mm (13.3 kg/m) with base plate in provided foundation as per specification no. OH-PL/RSJ 5 Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 550mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT 6 Supplying & erecting MS pole bracket for guarding/LT OH line, fabricated from angle iron 50x50x6mm and 1100mm long for necessary nos. of provided insulators, and erecting on pole with 50x6mm clamp complete as per specification no. OH-PL/BKT 7 Supplying and erecting all aluminium stranded conductors 7/3.10 mm. complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC 8 Supplying and erecting all aluminium stranded conductors 7/2.21 mm. complete. (Gnat) (73.77kg/km) as per specification No. OH-CON/AAC 9 Supplying and erecting G.I. stay set for poles, including loop insulators atinaccessible height with anchor plate 300x300x6mm., straining screws, G.l. staywire 7/10 SWG, G.l. stay rod 20mm x1.8m length and pole clamps duly erected in provided cement concrete foundation complete 10 Making cement concrete foundation including excavation (60 x 60 x 150) cmdeep in 1:3:6 cement concrete, (20 to 25) mm stone metal with necessary curingand finishing complete.(for stay). 11 Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 12 Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking /inside pole /Bus bars or any other places. as per specification No: WG-MA/BW 13 Supplying and erecting porcelain shackle type LT medium insulator 75x115mm dia. with G.l. (shackle) strips, nuts and bolts, complete 14 Part 29 Meter Highmast 15 Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mmdia.G.l.Rod completewithallmaterialsasper specification No. EA-EP(9-1-4) 16 Supplying & erecting mains with 2x6 sq.mm FRLSH copperPVC insulated wire laid in provided conduit /trunking /insidepole/Bus bars or any other places. as per specification No: WGMA/BW 17 Making cement concrete foundation including excavation (60 x60) cm x deep 1/6 of pole length in 1:3:6 cement concrete 20 x 25mm stone metal, 45 cm x 45 cm x 45 cm /45 cm dia. x 45 cm. height plinth duly plastered, with necessary curing and finishing complete.(for above 9 m poles) 16-3-4 18 Supplying and erecting steel tubular swaged pole 165.1 x 139.7 x114.3 mm. dia with 4.5 x 4.5 x 3.65 mm thickness ( 5 + 2 + 2m ) length respectively and total 9 m long with pole cap, baseplate in provided foundation (weight 147 kg) as perspecification no.OH-PL/STP 19 Supplying & erecting FRP box of size 250mm x 200mm x 100 mm, 2.7 mm thick complete on pole as per specification No. CB-SB 20 Supplying, erecting & marking SPMCB6A to32A, B- series (for lighting) in provided distribution boardas per specification No. SW-SWR/MCB 21 Supplying and erecting mains with ISI mark WP 2 x 6 sq. mm.1100 V. grade aluminium PVC insulated and PVC sheathedwires on G.I. bearer wire No. 8 SWG complete erected withrequired size of porcelain reel insulators and 16 SWG G.I.binding wire 22 Supplying and erecting iron work, sheet metal work consisting of CRCA sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the authority 23 Supplying & erecting G.I. pipe ‘A’ class 40 mm dia. erected for enclosing XLPE armoured cable on wall/pole as per specification no. CB-CE 24 Part 3 Single phase, 240V, Street Light Control Panel 25 Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP 26 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. CB-LT/AL 27 Supplying & erecting three phase, 415V, street light control panel up to themax load of 12kW, TPN MCB 63A, powder coated CRCA 14 SWG sheet,outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs.astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, controlwiring, metering device, etc. for automatic operation, with overcurrent, shortcircuit, earth fault protection on provided iron frame / CC foundation 28 Supplying & erecting single phase, 240V, street light control panel up to themax load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet,outdoor type, having IP54,IK10 protection, suitable rating contactor, 24 hrs.astronomical time switch with minimum 5 years battery back up,auto/manual selector switch, ON/OFF push buttons, indicator lamps, controlwiring, metering device, etc. for automatic operation, with overcurrent, shortcircuit, earth fault protection on provided iron frame/ CC foundation. 29 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drillingand welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match theswitchgears or as per directions by the authority. 30 Part 48 Meter Octogonal 31 Providing pipe type earthing with 40mm. dia. G.I. pipe or 20 mm dia. G.I. Rod complete with all materials testing and recording the results as per specification no. EA-EP 32 Making Cement concrete foundation including excavation (60 x 60 x 150)cm deep in 1:3:6 cement concrete 20 x 25 mm stone metal, (45 x 45 x 45)cm /45cm dia. x 45cm height plinth duly plastered, with necessary curing and finishing complete. (above 6m to 9m poles) 33 Providing & erecting 8 m high (clear height) galvanised octagonal pole withfoundation bolts having bottom of 135 mm A/F, top 70 mm A/F on providedfoundation as per specification no. OH-PL/OPL 34 Supplying, erecting & terminating FR XLPE insulated, galvanised steelformed wire armoured (strip) cable, 1100 V 4 core 16 sq. mm. aluminiumconductor complete erected with glands & lugs on wall/ trusses/pole or laid inprovided trench/ pipe as per specification no. CB-LT/AL 35 Supplying & erecting mains with 3x2.5 sq.mm FRLSH copper PVC insulatedwire laid in provided conduit/trunking/inside pole/bus bars or any other placesas per specification no. WG-MA/BW 36 Supplying, erecting & marking SP MCB 6A to 32A, B-series with rated short - circuit breaking capacity (Icn) 10kA in provided distribution board as per specification no. SW-MCB 37 Supplying and laying (including excavation of suitable width & depth up to 90 cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPE for enclosing cable below ground/road surface, complete. 38 Supplying & erecting single phase, 240V, street light control panel upto the max load of 6kW, SPN MCB 40A, powder coated CRCA 14 SWG sheet, outdoor typehaving IP54, IK10 protection, suitable rating contactor, 24 hrs. astronomical time switch with minimum 5 years battery back up, auto/manual selector switch, ON/OFF push buttons, indicator lamps, control wiring, metering device, etc. for automatic operation with overcurrent, short circuit, earth fault protection on provided iron frame/ CC foundation as per specification no. SW-STCP. 39 Providing and erecting galvanised 1000mm single arm sword type bracket with FRP dome and ball as per specification no. OH PL/PBKT 40 Supplying and erecting iron work, sheet metal work consisting of MS sheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drilling and welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match the switchgears or as per directions by the site engineer. 41 Part 5Condutor and AB Bunch Cable 42 Supplying and erecting Street light bracket made from 40 mm. dia ‘B’ class G.I. Pipe, 0.6m. in length along with pole cap of 300 mm length and 80 mm dia duly welded with provided leads as per specification no. FG-BKT/BPC 43 Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking /inside pole /Bus bars or any other places. as per specification No: WG-MA/BW 44 Supplying and erecting all aluminium stranded conductors 7/3.10 mm. complete. (Ant.) (145.0 kg/km) as per specification No. OH-CON/AAC 45 Supplying and erecting all aluminium stranded conductors 7/2.21 mm. complete. (Gnat) (73.77kg/km) as per specification No. OH-CON/AAC 46 Supplying and erecting 3 phase 5 core 50 sq.mm. (3x50+1x35+1x16) Aerial bunched aluminium cable along with necessary accessories for LT distribution on provided LT pole as per specification no. OH-CBL/ABC 47 Supplying and erecting 9 Way AB cable distribution box on provided pole with necessary accessories as per specification no. OH-ABC/JBS 48 Part 612.5 Meter Highmast 49 Providingpipetype earthing with 40mm. dia. G.l. pipe or 20 mmdia.G.l.Rod completewithallmaterialsasper specification No. EA-EP(9-1-4) 50 Providing earthing with copper earth plate size 30 x 30 x 0.315 cm complete with all materials, testing & recording the results as per specification no. EA-EP 51 Supplying and erecting mains with 2x2.5 sq.mm FRLSH copper PVCinsulated wire laid in provided conduit/trunking/inside pole/Bus bars or anyother places. as per specification No: WG-MA/BW 52 Supplying and erecting outdoor stand mounted feeder pillar for high-mast of the same manufacturer with 63A TPN MCB incomer, 24hr astronomical time switch with minimum 5 Years battery backup, , IP 54 and IK10 protection, 45 A TP contactor for automatic switching of luminaires, 2 no 9A contactors and raise/lower push button, and provision for termination of adequate size of incoming and outgoing cables complete erected in min. 14 SWG CRCA sheet box powder coated with supporting angles, self lock, gasket and slanting top erected on CC foundation complete. 53 Making M- 20 cement concrete foundation by considering the safe soil bearing capacity at site as 10 T/sq. m at 2 m depth including excavation and fixing provided nut bolts with the help of template, duly plastered as per design complete (for 12.5 m raising lowering high mast). 54 Supplying, erecting & terminating FR XLPE insulated, galvanised steel formedwire armoured (strip) cable 1100 V, 4 core 16 sq. mm. aluminium conductorcomplete erected with glands & lugs, on wall/ trusses/pole or laid in providedtrench/ pipe as per specification no. CB-LT/AL 55 Supplying and laying (including excavation of suitable width & depth up to 90cm) 50 mm outside dia. double wall corrugated pipes (DWC) of HDPEfor enclosing cable below ground/road surface, to required depth complete 56 Supplying and erecting iron work, sheet metal work consisting of CRCAsheets, various sections of iron, plates, chequered plates, rods, bars, MS pipes, etc. for panel board or any other purpose with bending, cutting, drillingand welding complete erected at the position with necessary materials duly painted with one coat of red oxide and two coats of enamel paint to match theswitchgears or as per directions by the authority. 57 Supplying and erecting 12.5 m (clear height) motorized high-mast (Top -150mm, Bottom- 360mm) hot dipped galvanized material with average minimum thickness 65 micron, made from high tensile structure grade steel as per BSEN - 10025 S355/E350 & 3mm thickness, with base plate 25 mm thick x OD 520 mm grade asper IS-2062, pole made in single section & submerge arc welded, with lowering &raising motorized unit, wire rope stainless steel 316 grade 2 nos., 7x19 Construction5mm, SG-DG U clamps, double drum with assembly 250 kg, 5x2.5 Sq.mm.flexible copper cable with lantern carriage assembly suitable for max. 12 nos.luminaires and its control gear box, lightning arrestor, arrangement for fixing aviation light, high-mast with serial number, factory inspection report/test reportof high-mast should be provided as per specifications on provided foundation J type stud/bolts with necessary accessories complete as per specification no. OHPL/ HM (excluding luminaries) 58 Supplying and erecting mains with 4x16 sq.mm FRLSH copper PVC insulated wire laid in provided conduit /trunking /inside pole/Bus bars or any other places as per specification No: WG-MA/BW

Key Value

Document Fees
INR 14750 /-
EMD
INR 124999.0 /-
Tender Value
INR 2.49 Crore /-
Disclaimer :
We takes all possible care for accurate & authentic tender information, however Users are requested to refer Original source of Tender Notice / Tender Document published by Tender Issuing Agency before taking any call regarding this tender.
Tell us about your Product / Services,
We will Find Tenders for you

Copyright © 2025 · All Rights Reserved. Terms of Usage | Privacy Policy

For Tender Information Services Visit : TenderDetail