tender for Supply And Installation Of Lt Meter Panels At Sanjay Gandhi Post Graduate Institute Of Medical Science R B Road Lucknow And Other Associated Works Against Deposit Scheme 2024-25 In The Area Of Vrindavan Under Jurisdiction Of Ee Eudd Vrindavan Lko., 1 Supply & Installation of6 Way Meter Panel(as per approved GTP of MVVNL/UPPCL )asmentionedbelowSpecification 2 6-WAY METER PANEL 3 INCOMER: 4 100 Amps, 415 volts, FP, 25 KA Moulded Case Circuit Breaker with thermal magnetic release 5 BUSBAR: 6 125 AmpTPN Aluminium busbars 7 OUTGOING: 8 6 Nos. 40 Amp TPN MCBs (10 KA) and space for 3 phase, dual register, pre paid type electronic meters. 9 Meter panels fabricated out of 14 / 16 SWG CRCA sheet steel, IP 42,wall/floormountingtype.Thesheetsteelshallundergo minimum9tank treatmentfollowed by finishing powdercoating of min60micronthickness as per following details complete with FP MCCB (25 KA) at incomer, TPN MCB (10 KA) at outgoings, TP Aluminium bus bar (100% neutral)etc. as required. The metering board shall have 3 phase indication lamps & have proper space to house 3 phase electronic meters and related hardware as required. Proper Earthing ofMeter Pannel should be done. 10 Meter Boards shall haveterminalblocksofrequiredquantity, sealedscrewandbacklitesheettomountmeterboardsand copper wires of required sizes upto meter compartment. 11 Size of the meter compartmenet shall be 400mm(H) x 350mm (W). 12 Supply & Installation of8 Way Meter Panel(as per approved GTP of MVVNL/UPPCL)asmentionedbelowSpecification 13 8-WAY METER PANEL 14 INCOMER: 15 100 Amps, 415 volts, FP, 25 KA Moulded Case Circuit Breaker with thermal magnetic release 16 BUSBAR: 17 125 AmpTPN Aluminium busbars 18 OUTGOING: 19 8 Nos. 40 Amp TPN MCBs (10 KA) and space for 3 phase, dual register, pre paid type electronic meters. 20 Meter panels fabricated out of 14 / 16 SWG CRCA sheet steel, IP 42,wall/floormountingtype.Thesheetsteelshallundergo minimum9tank treatmentfollowed by finishing powdercoating of min60micronthickness as per following details complete with FP MCCB (25 KA) at incomer, TPN MCB (10 KA) at outgoings, TP Aluminium bus bar (100% neutral)etc. as required. The metering board shall have 3 phase indication lamps & have proper space tohouse 3 phase electronic meters and related hardware as required.Proper Earthing ofMeter Pannel should be done. 21 Meter Boards shall haveterminalblocksofrequiredquantity, sealedscrewandbacklitesheettomountmeterboardsand copper wires of required sizes upto meter compartment. 22 Size of the meter compartmenet shall be 400mm(H) x 350mm (W). 23 Supply & Installation of10 Way Meter Panel(as per approved GTP of MVVNL/UPPCL )asmentionedbelowSpecification 24 10-WAY METER PANEL 25 INCOMER: 26 125 Amps, 415 volts, FP, 25 KA Moulded Case Circuit Breaker with thermal magnetic release 27 BUSBAR: 28 160 AmpTPN Aluminium busbars 29 OUTGOING: 30 10 Nos. 40 Amp TPN MCBs (10 KA) and space for 3 phase, dual register, pre paid type electronic meters. 31 Meter panels fabricated out of 14 / 16 SWG CRCA sheet steel, IP 42,wall/floormountingtype.Thesheetsteelshallundergo minimum9tank treatmentfollowed by finishing powdercoating of min60micronthickness as per following details complete with FP MCCB (25 KA) at incomer, TPN MCB (10 KA) at outgoings, TP Aluminium bus bar (100% neutral)etc. as required. The metering board shall have 3 phase indication lamps & have proper space tohouse 3 phase electronic meters and related hardware as required.Proper Earthing ofMeter Pannel should be done. 32 Meter Boards shall haveterminalblocksofrequiredquantity, sealedscrewandbacklitesheettomountmeterboardsand copper wires of required sizes upto meter compartment. 33 Size of the meter compartmenet shall be 400mm(H) x 350mm (W). 34 Supply & Installation of12 Way Meter Panel(as per approved GTP of MVVNL/UPPCL )asmentionedbelowSpecification 35 12-WAY METER PANEL 36 INCOMER: 37 125 Amps, 415 volts, FP, 25 KA Moulded Case Circuit Breaker with thermal magnetic release 38 BUSBAR: 39 160 Amp TPN Aluminium busbars 40 OUTGOING: 41 12 Nos. 40 Amp TPN MCBs (10 KA) and space for 3 phase, dual register, pre paid type electronic meters. 42 Meter panels fabricated out of 14 / 16 SWG CRCA sheet steel, IP 65,wall/floormountingtype, double door with canopy.Thesheetsteelshallundergo minimum9tank treatmentfollowed by finishing powdercoating of min60micronthickness as per following details complete with FP MCCBs (25 KA) at incomer, TPN MCBs (10 KA) at outgoings, TP Aluminium bus bar (100% neutral)etc. as required. The metering board shall have 3 phase indication lamps & have proper space tohouse 3 phase electronic meters and related hardware as required.(Outdoor Type).Proper Earthing ofMeter Pannel should be done 43 Meter Boards shall haveterminalblocksofrequiredquantity, sealedscrewandbacklitesheettomountmeterboardsand copper wires of required sizes upto meter compartment. 44 Size of the meter compartmenet shall be 400mm(H) x 350mm (W). 45 Supply & Installation of24 Way Meter Panel(as per approved GTP of MVVNL/UPPCL )asmentionedbelowSpecification 46 24-WAY METER PANEL 47 24-Way Meter Panel 48 INCOMER: 49 160 Amps, 415 volts, FP, 36 KA Moulded Case Circuit Breaker with thermal magnetic release 50 BUSBAR: 51 200 Amp TPN Aluminium busbars 52 OUTGOING: 53 24 Nos. 40 Amp TPN MCBs (10 KA) and space for 3 phase, dual register, pre paid type electronic meters. 54 Meter panels fabricated out of 14 / 16 SWG CRCA sheet steel, IP 65,wall/floormountingtype, double door with canopy.Thesheetsteelshallundergo minimum9tank treatmentfollowed by finishing powdercoating of min60micronthickness as per following details complete with FP MCCBs (25 KA) at incomer, TPN MCBs (10 KA) at outgoings, TP Aluminium bus bar (100% neutral)etc. as required. The metering board shall have 3 phase indication lamps & have proper space tohouse 3 phase electronic meters and related hardware as required.(Outdoor Type).Proper Earthing ofMeter Pannel should be done 55 Meter Boards shall haveterminalblocksofrequiredquantity, sealedscrewandbacklitesheettomountmeterboardsand copper wires of required sizes upto meter compartment. 56 Size of the meter compartmenet shall be 400mm(H) x 350mm (W). 57 Supply & Installation of2 Way Meter Panel(as per approved GTP of MVVNL/UPPCL )asmentionedbelowSpecification 58 2-WAY METER PANEL 59 2-Way Meter Panel 60 INCOMER: 61 100 Amps, 415 volts, FP, 25 KA Moulded Case Circuit Breaker with thermal magnetic release 62 BUSBAR: 63 125 Amp TPN Aluminium busbars 64 OUTGOING: 65 2 Nos. 63 Amp TPN MCBs (10 KA) and space for 3 phase, dual register, pre paid type electronic meters. 66 Meter panels fabricated out of 14 / 16 SWG CRCA sheet steel, IP 42,wall/floormountingtype.Thesheetsteelshallundergo minimum9tank treatmentfollowed by finishing powdercoating of min60micronthickness as per following details complete with FP MCCB (25 KA) at incomer, TPN MCB (10 KA) at outgoings, TP Aluminium bus bar (100% neutral)etc. as required. The metering board shall have 3 phase indication lamps & have proper space tohouse 3 phase electronic meters and related hardware as required. Proper Earthing ofMeter Pannel should be done. 67 Meter Boards shall haveterminalblocksofrequiredquantity, sealedscrewandbacklitesheettomountmeterboardsand copper wires of required sizes upto meter compartment. 68 Size of the meter compartmenet shall be 400mm(H) x 350mm (W). 69 Supply & Installation of2 Way Meter Panel(as per approved GTP of MVVNL/UPPCL )asmentionedbelowSpecification 70 2-WAY METER PANEL 71 INCOMER: 72 100 Amps, 415 volts, FP, 25 KA Moulded Case Circuit Breaker with thermal magnetic release 73 BUSBAR: 74 125 Amp TPN Aluminium busbars 75 OUTGOING: 76 2 Nos. 63 Amp TPN MCBs (10 KA) and space for 3 phase, dual register, pre paid type electronic meters. 77 Meter panels fabricated out of 14 / 16 SWG CRCA sheet steel, IP 65,wall/floormountingtype, double door with canopy.Thesheetsteelshallundergo minimum9tank treatmentfollowed by finishing powdercoating of min60micronthickness as per following details complete with FP MCCBs (25 KA) at incomer, TPN MCBs (10 KA) at outgoings, TP Aluminium bus bar (100% neutral)etc. as required. The metering board shall have 3 phase indication lamps & have proper space tohouse 3 phase electronic meters and related hardware as required.(Outdoor Type).Proper Earthing ofMeter Pannel should be done 78 Meter Boards shall haveterminalblocksofrequiredquantity, sealedscrewandbacklitesheettomountmeterboardsand copper wires of required sizes upto meter compartment. 79 Size of the meter compartmenet shall be 400mm(H) x 350mm (W). 80 Supply & Installation of4 Way Meter Panel(as per approved GTP of MVVNL/UPPCL )asmentionedbelowSpecification 81 4-WAY METER PANEL 82 Supply of 4-Way Meter Panel 83 INCOMER: 84 100 Amps, 415 volts, FP, 25 KA Moulded Case Circuit Breaker with thermal magnetic release 85 BUSBAR: 86 125 Amp TPN Aluminium busbars 87 OUTGOING: 88 4 Nos. 63 Amp TPN MCBs (10 KA) and space for 3 phase, dual register, pre paid type electronic meters. 89 Meter panels fabricated out of 14 / 16 SWG CRCA sheet steel, IP 65,wall/floormountingtype, double door with canopy.Thesheetsteelshallundergo minimum9tank treatmentfollowed by finishing powdercoating of min60micronthickness as per following details complete with FP MCCBs (25 KA) at incomer, TPN MCBs (10 KA) at outgoings, TP Aluminium bus bar (100% neutral)etc. as required. The metering board shall have 3 phase indication lamps & have proper space tohouse 3 phase electronic meters and related hardware as required.(Outdoor Type).Proper Earthing ofMeter Pannel should be done 90 Meter Boards shall haveterminalblocksofrequiredquantity, sealedscrewandbacklitesheettomountmeterboardsand copper wires of required sizes upto meter compartment. 91 Size of the meter compartmenet shall be 400mm(H) x 350mm (W). 92 Supply & Installation of6 Way Meter Panel(as per approved GTP of MVVNL/UPPCL )asmentionedbelowSpecification 93 6-WAY METER PANEL 94 INCOMER: 95 160 Amps, 415 volts, FP, 25 KA Moulded Case Circuit Breaker with thermal magnetic release 96 BUSBAR: 97 200 AmpTPN Aluminium busbars 98 OUTGOING: 99 6 Nos. 63 Amp TPN MCBs (10 KA) and space for 3 phase, dual register, pre paid type electronic meters. 100 Meter panels fabricated out of 14 / 16 SWG CRCA sheet steel, IP 65,wall/floormountingtype, double door with canopy.Thesheetsteelshallundergo minimum9tank treatmentfollowed by finishing powdercoating of min60micronthickness as per following details complete with FP MCCBs (25 KA) at incomer, TPN MCBs (10 KA) at outgoings, TP Aluminium bus bar (100% neutral)etc. as required. The metering board shall have 3 phase indication lamps & have proper space tohouse 3 phase electronic meters and related hardware as required.(Outdoor Type).Proper Earthing ofMeter Pannel should be done 101 Meter Boards shall haveterminalblocksofrequiredquantity, sealedscrewandbacklitesheettomountmeterboardsand copper wires of required sizes upto meter compartment. 102 Size of the meter compartmenet shall be 400mm(H) x 350mm (W). 103 Installation of1 Way Meter PanelasmentionedbelowSpecification 104 1-WAY METER PANEL 105 G.S.T.Extra as per rules.