Housing Urban and Rular Development Local Bodies Closing in 0 days TDR #45706660

Tender For Supply And Installation Of Ac At Sports Complex At Haridwar

Issued by Local Bodies · haridwar, Uttarakhand
Tender Value
53.58 Lakhs
Estimated cost
Bid Submission
25 Oct 2024
0 days left
EMD
1.61 Lakhs
Bank guarantee accepted
Document Fee
3780
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
haridwar → Uttarakhand
EMD Exemption
Not Available
Quantity
Not Available

Project Description

Supply And Installation Of Ac At Sports Complex At Haridwar , Outdoor Units , Supply, Installation, Testing And Commissioningof Air Cooled & Inverter Based Variable Refrigerant Volume / Flow Modular Type Split Air Conditioning System With R410a Suitable For 415 ± 10% , 50 Cycles. The System Shall Consist Of Indoor Units & External Condensing Units, Complete In All Respects, Inclusive Of Insulated Copper Refrigerant Piping, Drain Piping Of Required Size, Electrical & Microprocessor Panel, Wiring, Control Cabling And Earthing, Isolating Valves, Stands And Supports With All Other Necessary Accessories For Proper Functioning Of The Units.Make: To Be Approved By Engineer In Charge Before Installation. , Indoor Units , Supply,Installation, Testing And Commissioning Of Indoor Units Equipped With Pre-Filter, Fan Section With Low Noise Fan, Multispeed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Pan, Insulation, Pipe Connections Etc. Of Various Capacities. Make: To Be Approved By Engineer In Charge Before Installation. 4-Way Cassette Type Indoor Units 2.5 Hp (2 Tr) , Supply, Installation, Testing And Commissioning Of Cordlessremotes Required For Vrv/Vrftype Indoor Units Completeas Required. Make: To Be Approved By Engineer In Charge Before Installation. , Supply, Installation, Testing And Commissioning Of Y-Joint / Refentcompleteas Required. Make: To Be Approved By Engineer In Charge Before Installation. For Indoor Unit , Supply, Installation, Testing And Commissioning Of Y-Joint / Refentcompleteas Required. Make: To Be Approved By Engineer In Charge Before Installation. For Outdoor Unit (Bhf Kit) , Refrigerant Piping , Supplying & Installation Of Interconnecting Following Sizes Of One End Expanded Refrigerant Copper Pipeoffollowingouterdiameter, Insulatedwithclosedcellelectrometricnitrilerubber Tubular Insulation Classo Between Each Set Of Indoor & Outdoor Units, Allpipinginsidethebuildingshallbepropelrly Fixed/Supported With Suitable Size Of Clamp/ M.S. Hanger Andallexternalpipingshallrunincable Tray (Price Extra) Etc. As Reqd.(The Final Refrigerant Pipe Sizes Shall Be As Per Manufacturer). 22.2 Mm Dia With 19Mm Thick Insulation , Supplying & Installation Of Interconnecting Following Sizes Of One End Expanded Refrigerant Copper Pipeoffollowingouterdiameter, Insulatedwithclosedcellelectrometricnitrilerubber Tubular Insulation Classo Between Each Set Of Indoor & Outdoor Units, Allpipinginsidethebuildingshallbepropelrly Fixed/Supported With Suitable Size Of Clamp/ M.S. Hanger Andallexternalpipingshallrunincable Tray (Price Extra) Etc. As Reqd.(The Final Refrigerant Pipe Sizes Shall Be As Per Manufacturer). 15.9 Mm Dia With 13Mm Thick Insulation , Supplying & Installation Of Interconnecting Following Sizes Of One End Expanded Refrigerant Copper Pipeoffollowingouterdiameter, Insulatedwithclosedcellelectrometricnitrilerubber Tubular Insulation Classo Between Each Set Of Indoor & Outdoor Units, Allpipinginsidethebuildingshallbepropelrly Fixed/Supported With Suitable Size Of Clamp/ M.S. Hanger Andallexternalpipingshallrunincable Tray (Price Extra) Etc. As Reqd.(The Final Refrigerant Pipe Sizes Shall Be As Per Manufacturer). 9.5 Mm Dia With 13Mm Thick Insulation , Drain Piping , Providing And Fixing Of Upvc Piping Complete With Fittings, Supportsasperspecificationsanddulyinsulatedwith 6Mmthickclosedcellnitrilerubberinsulation. Make: To Be Approved By Engineer In Charge Before Installation. 50 Mm Dia , Providing And Fixing Of Upvc Piping Complete With Fittings, Supportsasperspecificationsanddulyinsulatedwith 6Mmthickclosedcellnitrilerubberinsulation. Make: To Be Approved By Engineer In Charge Before Installation. 40 Mm Dia , Providing And Fixing Of Upvc Piping Complete With Fittings, Supportsasperspecificationsanddulyinsulatedwith 6Mmthickclosedcellnitrilerubberinsulation. Make: To Be Approved By Engineer In Charge Before Installation. 32 Mm Dia , Power Cables , Supplyandfixingoffollowingsizesofxlpe/Pvc Insulated Aluminium/Copper Cable, Overall Pvc Sheathed 1.1 Kv Grade Cables Conforming To Relevant Is Code And Technicalspecifications. 3.5 C X70 Sq.Mm ( Aluminium Armoured) , Supplyandfixingoffollowingsizesofxlpe/Pvc Insulated Aluminium/Copper Cable, Overall Pvc Sheathed 1.1 Kv Grade Cables Conforming To Relevant Is Code And Technicalspecifications. 4C X 6 Sq.Mm. Cu Armoured , Supplyandfixingoffollowingsizesofxlpe/Pvc Insulated Aluminium/Copper Cable, Overall Pvc Sheathed 1.1 Kv Grade Cables Conforming To Relevant Is Code And Technicalspecifications. 3C X 2.5 Sq.Mm. Cu. (Unarmoured) , Supplying And Fixing 8 Way, Tp&N, Mcb Distribution Board, Vtpn Db, 240 V, On Surface/ Recess Complete As Required. With 1 Incomer 4P 100Amp Mccb, For Outgoing 6 Nos. 4P 40Amp Mcb, 15 Nos. Sp 16Amp Mcb And All Necessary Arrangments. Double Door Dust And Vermin Proof, Suitable Luxes And Glands For Connections , Incomiong And Outgoing For Indoor And Outdoor Units. , Transmission & Control Wiring , Supply,Installation, Testing And Commissioning Of Controlcumtrans-Missionwiringofcopperbetween Indoorandoutdoorunit Inpvc Conduit. (2 Core X 4.00 Sq Mm) , Supply And Charging Of Refrigerant R-410A Complete As Required. , Supply Of Pcc Blocks Or Ms Stand For Vrv/Vrf Outdoorunits Complete In All Respect. , Gi Cable Tray For Installation And Laying Of Cables, Refrigrent Pipe, Drain Pipe, Wires Etc, With Different Sections For Different Cables/Pipes, The Tray Shall Be Sturdy, With All Clamping, Fastner, Rivet, Hole-Past Etc Any Other Accessory As Required For Fixing Of Tray In Ceiling/Wall And Cables/Pipes, For Neat Installation. Of The Following Width. 300Mm , Gi Cable Tray For Installation And Laying Of Cables, Refrigrent Pipe, Drain Pipe, Wires Etc, With Different Sections For Different Cables/Pipes, The Tray Shall Be Sturdy, With All Clamping, Fastner, Rivet, Hole-Past Etc Any Other Accessory As Required For Fixing Of Tray In Ceiling/Wall And Cables/Pipes, For Neat Installation. Of The Following Width. 150Mm , Sitc Of Following Minimum Capacity Vrv/Vrf Highwall Type Indoor Unit Equipped With Washable Synthetic Media Prefilter, Fan Section With Low Noise Fan /Dynamically Balanced Blower, Multispeed Motor, Coil Section With Dx Copper Coil, Electronic Expansion Valve, Outer Cabinet, Cordless Remote Control, Drain Pan, Necessary Accessories Etc., Suitable For Operation On 230V±10%, 50Hz, Single Phase Ac Supply, Complete As Required. The Unit Shall Have Automatic Force Shut Down Provision In Case Of Fire On Receiving Signal From Bms System. The Cooling Capacity Of Indoor Unit Will Beat Air Inlet Conditions Of 27Degree C Db And 19Degree Cwbtemperature. Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Vrv/Vrf System, Completewith Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulatedwith Xple Class O Tubular Insulation /With Class O Closed Cell Elastometric Nitrile Rubbertubular Sleeves Sections Of Specified Thickness As Given Below For Suction And Liquid Lines And One Year Warranty Complete Systam , For Year Parts Warranty ,Twelve Year Compressor Warranty ,All Accessories As Per Specifications Etc. As Required With 2Tr Capacity(3 Star).

BOQ

Name of Work: SITC of Air Conditioning System ay HRDA city sports complex, haridwar
Sl. No. Item Description
1Outdoor Units
2Supply, installation, testing and commissioningof AIR COOLED & INVERTER BASED VARIABLE REFRIGERANT VOLUME / FLOW MODULAR TYPE SPLIT AIR CONDITIONING SYSTEM with R410A suitable for 415 ± 10% , 50 cycles. The system shall consist of indoor units & external condensing units, complete in all respects, inclusive of insulated copper refrigerant piping, drain piping of required size, electrical & microprocessor panel, wiring, control cabling and earthing, isolating valves, stands and supports with all other necessary accessories for proper functioning of the units.Make: To be approved by engineer in charge before installation.
3Indoor Units
4Supply,installation, testing and commissioning of Indoor units equipped with pre-filter, fan section with low noise fan, multispeed motor, coil section with DX coil, outer cabinet, drain pan, insulation, pipe connections etc. of various capacities.Make: To be approved by engineer in charge before installation. 4-way Cassette Type Indoor Units 2.5 HP (2 TR)
5Supply, installation, testing and commissioning of CordlessRemotes required for VRV/VRFtype indoor units completeas required.Make: To be approved by engineer in charge before installation.
6Supply, installation, testing and commissioning of Y-Joint / Refentcompleteas required. Make: To be approved by engineer in charge before installation. For Indoor Unit
7Supply, installation, testing and commissioning of Y-Joint / Refentcompleteas required. Make: To be approved by engineer in charge before installation. For Outdoor Unit (BHF Kit)
8Refrigerant Piping
9Supplying & Installation of interconnecting following sizes of one end expanded refrigerant copper pipeoffollowingouterdiameter, insulatedwithclosedcellelectrometricnitrilerubber tubular insulation Class\"O\" between each set of indoor & outdoor units, allpipinginsidethebuildingshallbepropelrly fixed/supported with suitable size of clamp/ M.S. hanger andallexternalpipingshallrunincable tray (Price Extra) etc. as reqd.(The final refrigerant pipe sizes shall be as per manufacturer). 22.2 mm dia with 19mm thick insulation
10Supplying & Installation of interconnecting following sizes of one end expanded refrigerant copper pipeoffollowingouterdiameter, insulatedwithclosedcellelectrometricnitrilerubber tubular insulation Class\"O\" between each set of indoor & outdoor units, allpipinginsidethebuildingshallbepropelrly fixed/supported with suitable size of clamp/ M.S. hanger andallexternalpipingshallrunincable tray (Price Extra) etc. as reqd.(The final refrigerant pipe sizes shall be as per manufacturer). 15.9 mm dia with 13mm thick insulation
11Supplying & Installation of interconnecting following sizes of one end expanded refrigerant copper pipeoffollowingouterdiameter, insulatedwithclosedcellelectrometricnitrilerubber tubular insulation Class\"O\" between each set of indoor & outdoor units, allpipinginsidethebuildingshallbepropelrly fixed/supported with suitable size of clamp/ M.S. hanger andallexternalpipingshallrunincable tray (Price Extra) etc. as reqd.(The final refrigerant pipe sizes shall be as per manufacturer). 9.5 mm dia with 13mm thick insulation
12Drain Piping
13Providing and fixing of uPVC Piping complete with fittings, supportsasperspecificationsanddulyinsulatedwith 6mmthickclosedcellnitrilerubberinsulation.Make: To be approved by engineer in charge before installation. 50 mm dia
14Providing and fixing of uPVC Piping complete with fittings, supportsasperspecificationsanddulyinsulatedwith 6mmthickclosedcellnitrilerubberinsulation.Make: To be approved by engineer in charge before installation. 40 mm dia
15Providing and fixing of uPVC Piping complete with fittings, supportsasperspecificationsanddulyinsulatedwith 6mmthickclosedcellnitrilerubberinsulation.Make: To be approved by engineer in charge before installation. 32 mm dia
16POWER CABLES
17SupplyandFixingoffollowingsizesofXLPE/PVC insulated Aluminium/Copper cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technicalspecifications. 3.5 C X70 sq.mm ( Aluminium Armoured)
18SupplyandFixingoffollowingsizesofXLPE/PVC insulated Aluminium/Copper cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technicalspecifications. 4C x 6 sq.mm. Cu Armoured
19SupplyandFixingoffollowingsizesofXLPE/PVC insulated Aluminium/Copper cable, overall PVC sheathed 1.1 KV grade cables conforming to relevant IS code and technicalspecifications. 3C x 2.5 sq.mm. Cu. (Unarmoured)
20Supplying and fixing 8 way, TP&N, MCB distribution board, VTPN DB, 240 V, on surface/ recess complete as required. With 1 Incomer 4P 100Amp MCCB, for outgoing 6 Nos. 4P 40Amp MCB, 15 Nos. SP 16Amp MCB and all necessary arrangments. Double door dust and vermin proof, suitable luxes and glands for connections , incomiong and outgoing for Indoor and outdoor units.
21Transmission & Control Wiring
22Supply,installation, testing and commissioning of controlcumtrans-missionwiringofcopperbetween indoorandoutdoorunit inPVC Conduit.(2 core x 4.00 Sq mm)
23Supply and charging of Refrigerant R-410A complete as required.
24Supply of PCC Blocks or MS Stand for VRV/VRF Outdoorunits complete in all respect.
25GI Cable tray for installation and laying of cables, refrigrent pipe, drain pipe, wires etc, with different sections for different cables/pipes, the tray shall be sturdy, with all clamping, fastner, rivet, hole-past etc any other accessory as required for fixing of tray in ceiling/wall and cables/pipes, for neat installation. of the following width. 300mm
26GI Cable tray for installation and laying of cables, refrigrent pipe, drain pipe, wires etc, with different sections for different cables/pipes, the tray shall be sturdy, with all clamping, fastner, rivet, hole-past etc any other accessory as required for fixing of tray in ceiling/wall and cables/pipes, for neat installation. of the following width. 150mm
27SITC of following minimum capacity VRV/VRF Highwall type Indoor unit equipped with washable synthetic media prefilter, fan section with low noise fan /dynamically balanced blower, multispeed motor, coil section with DX copper coil, electronic expansion valve, outer cabinet, cordless remote control, drain pan, necessary accessories etc., suitable for operation on 230V±10%, 50Hz, single phase AC supply, complete as required. The unit shall have automatic force shut down provision in case of fire on receiving signal from BMS System. The cooling capacity of indoor unit will beat air inlet conditions of 27Degree C DB and 19Degree CWBtemperature. Including vaccumiazation and Nitrogen testing of following nominal sizes of soft/hard drawn copper refrigerant piping for VRV/VRF system, completewith fittings, with suitable adjustable ring type hanger supports, jointing/brazing including accessories, insulatedwith XPLE Class O tubular insulation /with Class O closed cell elastometric nitrile rubbertubular sleeves sections of specified thickness as given below for Suction and Liquid lines and one year warranty complete systam , for year parts warranty ,twelve year compressor warranty ,all accessories as per specifications etc. as required with 2TR Capacity(3 star).

AI Tender Summary

OUR REF NO 45706660
AUTHORITY Local Bodies
TENDER VALUE 53.58 Lakhs
LAST DATE 25-10-2024
Authority
Authority Name Development Authority
Work Description Supply And Installation Of Ac At Sports Complex At Haridwar , Outdoor Units , Supply, Installation, Testing And Commissioningof Air Cooled & Inverter Based Variable Refrigerant Volume / Flow Modular Type Split Air Conditioning System With R410a Suitable For 415 ± 10% , 50 Cycles. The System Shall Consist Of Indoor Units & External Condensing Units, Complete In All Respects, Inclusive Of Insulated Copper Refrigerant Piping, Drain Piping Of Required Size, Electrical & Microprocessor Panel, Wiring, Control Cabling And Earthing, Isolating Valves, Stands And Supports With All Other Necessary Accessories For Proper Functioning Of The Units.Make: To Be Approved By Engineer In Charge Before Installation. , Indoor Units , Supply,Installation, Testing And Commissioning Of Indoor Units Equipped With Pre-Filter, Fan Section With Low Noise Fan, Multispeed Motor, Coil Section With Dx Coil, Outer Cabinet, Drain Pan, Insulation, Pipe Connections Etc. Of Various Capacities. Make: To Be Approved By Engineer In Charge Before Installation. 4-Way Cassette Type Indoor Units 2.5 Hp (2 Tr) , Supply, Installation, Testing And Commissioning Of Cordlessremotes Required For Vrv/Vrftype Indoor Units Completeas Required. Make: To Be Approved By Engineer In Charge Before Installation. , Supply, Installation, Testing And Commissioning Of Y-Joint / Refentcompleteas Required. Make: To Be Approved By Engineer In Charge Before Installation. For Indoor Unit , Supply, Installation, Testing And Commissioning Of Y-Joint / Refentcompleteas Required. Make: To Be Approved By Engineer In Charge Before Installation. For Outdoor Unit (Bhf Kit) , Refrigerant Piping , Supplying & Installation Of Interconnecting Following Sizes Of One End Expanded Refrigerant Copper Pipeoffollowingouterdiameter, Insulatedwithclosedcellelectrometricnitrilerubber Tubular Insulation Classo Between Each Set Of Indoor & Outdoor Units, Allpipinginsidethebuildingshallbepropelrly Fixed/Supported With Suitable Size Of Clamp/ M.S. Hanger Andallexternalpipingshallrunincable Tray (Price Extra) Etc. As Reqd.(The Final Refrigerant Pipe Sizes Shall Be As Per Manufacturer). 22.2 Mm Dia With 19Mm Thick Insulation , Supplying & Installation Of Interconnecting Following Sizes Of One End Expanded Refrigerant Copper Pipeoffollowingouterdiameter, Insulatedwithclosedcellelectrometricnitrilerubber Tubular Insulation Classo Between Each Set Of Indoor & Outdoor Units, Allpipinginsidethebuildingshallbepropelrly Fixed/Supported With Suitable Size Of Clamp/ M.S. Hanger Andallexternalpipingshallrunincable Tray (Price Extra) Etc. As Reqd.(The Final Refrigerant Pipe Sizes Shall Be As Per Manufacturer). 15.9 Mm Dia With 13Mm Thick Insulation , Supplying & Installation Of Interconnecting Following Sizes Of One End Expanded Refrigerant Copper Pipeoffollowingouterdiameter, Insulatedwithclosedcellelectrometricnitrilerubber Tubular Insulation Classo Between Each Set Of Indoor & Outdoor Units, Allpipinginsidethebuildingshallbepropelrly Fixed/Supported With Suitable Size Of Clamp/ M.S. Hanger Andallexternalpipingshallrunincable Tray (Price Extra) Etc. As Reqd.(The Final Refrigerant Pipe Sizes Shall Be As Per Manufacturer). 9.5 Mm Dia With 13Mm Thick Insulation , Drain Piping , Providing And Fixing Of Upvc Piping Complete With Fittings, Supportsasperspecificationsanddulyinsulatedwith 6Mmthickclosedcellnitrilerubberinsulation. Make: To Be Approved By Engineer In Charge Before Installation. 50 Mm Dia , Providing And Fixing Of Upvc Piping Complete With Fittings, Supportsasperspecificationsanddulyinsulatedwith 6Mmthickclosedcellnitrilerubberinsulation. Make: To Be Approved By Engineer In Charge Before Installation. 40 Mm Dia , Providing And Fixing Of Upvc Piping Complete With Fittings, Supportsasperspecificationsanddulyinsulatedwith 6Mmthickclosedcellnitrilerubberinsulation. Make: To Be Approved By Engineer In Charge Before Installation. 32 Mm Dia , Power Cables , Supplyandfixingoffollowingsizesofxlpe/Pvc Insulated Aluminium/Copper Cable, Overall Pvc Sheathed 1.1 Kv Grade Cables Conforming To Relevant Is Code And Technicalspecifications. 3.5 C X70 Sq.Mm ( Aluminium Armoured) , Supplyandfixingoffollowingsizesofxlpe/Pvc Insulated Aluminium/Copper Cable, Overall Pvc Sheathed 1.1 Kv Grade Cables Conforming To Relevant Is Code And Technicalspecifications. 4C X 6 Sq.Mm. Cu Armoured , Supplyandfixingoffollowingsizesofxlpe/Pvc Insulated Aluminium/Copper Cable, Overall Pvc Sheathed 1.1 Kv Grade Cables Conforming To Relevant Is Code And Technicalspecifications. 3C X 2.5 Sq.Mm. Cu. (Unarmoured) , Supplying And Fixing 8 Way, Tp&N, Mcb Distribution Board, Vtpn Db, 240 V, On Surface/ Recess Complete As Required. With 1 Incomer 4P 100Amp Mccb, For Outgoing 6 Nos. 4P 40Amp Mcb, 15 Nos. Sp 16Amp Mcb And All Necessary Arrangments. Double Door Dust And Vermin Proof, Suitable Luxes And Glands For Connections , Incomiong And Outgoing For Indoor And Outdoor Units. , Transmission & Control Wiring , Supply,Installation, Testing And Commissioning Of Controlcumtrans-Missionwiringofcopperbetween Indoorandoutdoorunit Inpvc Conduit. (2 Core X 4.00 Sq Mm) , Supply And Charging Of Refrigerant R-410A Complete As Required. , Supply Of Pcc Blocks Or Ms Stand For Vrv/Vrf Outdoorunits Complete In All Respect. , Gi Cable Tray For Installation And Laying Of Cables, Refrigrent Pipe, Drain Pipe, Wires Etc, With Different Sections For Different Cables/Pipes, The Tray Shall Be Sturdy, With All Clamping, Fastner, Rivet, Hole-Past Etc Any Other Accessory As Required For Fixing Of Tray In Ceiling/Wall And Cables/Pipes, For Neat Installation. Of The Following Width. 300Mm , Gi Cable Tray For Installation And Laying Of Cables, Refrigrent Pipe, Drain Pipe, Wires Etc, With Different Sections For Different Cables/Pipes, The Tray Shall Be Sturdy, With All Clamping, Fastner, Rivet, Hole-Past Etc Any Other Accessory As Required For Fixing Of Tray In Ceiling/Wall And Cables/Pipes, For Neat Installation. Of The Following Width. 150Mm , Sitc Of Following Minimum Capacity Vrv/Vrf Highwall Type Indoor Unit Equipped With Washable Synthetic Media Prefilter, Fan Section With Low Noise Fan /Dynamically Balanced Blower, Multispeed Motor, Coil Section With Dx Copper Coil, Electronic Expansion Valve, Outer Cabinet, Cordless Remote Control, Drain Pan, Necessary Accessories Etc., Suitable For Operation On 230V±10%, 50Hz, Single Phase Ac Supply, Complete As Required. The Unit Shall Have Automatic Force Shut Down Provision In Case Of Fire On Receiving Signal From Bms System. The Cooling Capacity Of Indoor Unit Will Beat Air Inlet Conditions Of 27Degree C Db And 19Degree Cwbtemperature. Including Vaccumiazation And Nitrogen Testing Of Following Nominal Sizes Of Soft/Hard Drawn Copper Refrigerant Piping For Vrv/Vrf System, Completewith Fittings, With Suitable Adjustable Ring Type Hanger Supports, Jointing/Brazing Including Accessories, Insulatedwith Xple Class O Tubular Insulation /With Class O Closed Cell Elastometric Nitrile Rubbertubular Sleeves Sections Of Specified Thickness As Given Below For Suction And Liquid Lines And One Year Warranty Complete Systam , For Year Parts Warranty ,Twelve Year Compressor Warranty ,All Accessories As Per Specifications Etc. As Required With 2Tr Capacity(3 Star).
Basic Detail
Tender No Supply and installition of AC at sports complex at Haridwar
Bidding Type Tender
Location
City haridwar
State Uttarakhand
Key Dates
Publish Date 11 Oct 2024
Submission Date 25 Oct 2024
Open Date 25 Oct 2024
Finance
Tender Value 53.58 Lakhs
Tender Fee 3780
EMD 1.61 Lakhs
Exemption Not Available
Document List
cf83edb3-8ec4-473a-955b-439553be49d4.html
AC.pdf
BOQ_91761.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 11, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Oct 25, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Oct 25, 2024

Bid Opening Date

Technical bids will be opened and evaluated.

Completed

Tender Documents

Download All (ZIP) ↓
html

cf83edb3-8ec4-473a-955b-439553be49d4.html

pdf

AC.pdf

xls

BOQ_91761.xls

pdf

Tendernotice_1.pdf

TenderDetail
Loading tenders