| 1 | Supply and fixing in replacement PVC insulated and sheathed weather proof two core 2.5 sqmm single stranded aluminium conductor service cable for connection complete all as specified and directed. |
| 2 | Supply and fixing in replacement PVC insulated and sheathed weather proof two core 4.0 sqmm single stranded aluminium conductor service cable for connection complete all as specified and directed. |
| 3 | Supply and fixing in replacement PVC insulated and sheathed weather proof two core 6.0 sqmm single stranded aluminium conductor service cable for connection complete all as specified and directed. |
| 4 | Supply and fixing in replacement of unserviceable garden lights with LED landscape luminaires 10 Watts pressure die cast powder coated housing with PC diffuser,Efficient high output COB for garden, Pathway lightning, IP 66 protection complete all as specified and directed. |
| 5 | Supply and fixing in replacement of unserviceable 35W LED Post top made in cast aluminium spigot housing with decorative opal acrylic diffuser and IP65 protection complete with all accessories suitable for connection of copper wires complete all as specified and directed. |
| 6 | Supply and fixing in replacement of unserviceable highmast flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium housing in powder coated die-casting power coated in gray finish,high power LED with IP 66protection, fins are provided on housing ,heat resistant tempered glass for protectionwith 5 KV surge protection of 150 W LED 5700K complete all as specified and directed.Note :Cost of necessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay /low bay luminaires,security light /high mast light fittings etc shall be deemed to be included in the unit rate quoted. |
| 7 | Supply and fixing in replacement of unserviceable highmast flood light luminaire of HPSV/MH,with LED flood light fitting consist of PDC aluminium housing in powder coated die-casting power coated in gray finish,high power LED with IP 66protection, fins are provided on housing ,heat resistant tempered glass for protectionwith 5 KV surge protection of 120 W LED 5700K complete all as specified and directed.Note :Cost of necessary tools and plants such as ladders, hydra for repair of high raised high bay / medium bay /low bay luminaires,security light /high mast light fittings etc shall be deemed to be included in the unit rate quoted. |
| 8 | Supply and fixing in replacement energy efficient LED street light fitting of 25 Watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency morethan 100 lumens / watt individual LED\"s should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed. |
| 9 | Supply and fixing energy efficient LED street light fitting of 45 Watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency morethan 100 lumens / watt individual LED\"s should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed. |
| 10 | Supply and fixing energy efficient LED street light fitting of 60 Watt ,epoxy powder coated pressure die cast aluminium housing to act as heat sink for efficient dissipation of heat and toughened glass with IP 66 degree of protection, system luminous efficency morethan 100 lumens / watt individual LED\"s should have lenses for better throw across and along road, PF>0.9 with voltage range 140 to 270 Volt, fitting should be provided wih inbuilt 10 KV minimum surge protection, short circuit and over voltage protection facility for Driver and fiiting including bracket of suitable size upto 1.5 mtr long & MS Flat clamp of suitable size complete all as specified and directed. |
| 11 | Supply and fixing of 45 watt Inverter LED Street Light with IR Sensor for automatic On-Off of street light and shall have inbuilt Li-on battery for 90mins power backup in case ofpower failure. Housing of fixture shall be presurre die cast and system efficacy >100LPW, CRI >70, CCT 5700K, PF>0.9, THD<15% complete all as specified and directed. |
| 12 | Supply and fixing of 60 watt Inverter LED Street Light with IR Sensor for automatic On-Off of street light and shall have inbuilt Li-on battery for 90mins power backup in case ofpower failure. Housing of fixture shall be presurre die cast and system efficacy >100LPW, CRI >70, CCT 5700K, PF>0.9, THD<15% complete all as specified and directed. |
| 13 | Supply and fixing in renewalLED inverter batton fitting1 x18/20 Watt, 220 V decorative box type with driver 4\" complete fitting connection with 3 core flexible copper cable 23/0.00076 from ceiling rose to tube fitting connection etc complete all as specified and directed. |
| 14 | Supply and fixing in renewal LED Ceiling light square recessed mounted LED flat panel complete 600mm x 600mm, 230 volts 35/36 Watt LED light fixing on Surface/ceiling and connecting with 3 corecopper conductor FR-LSH cable etc complete all as specified and directed. |
| 15 | Supply and laying/ fixing of GI tube, light grade, 50mm dia for encasing cables for mechanical protection, laid under plinth/ floors/ path/ culverts or fixed on wall or concealed in wall/ floor or along poles or as street light poles or as mounting bracket, bent to shape with complete accessories such as bends/ sockets/ reducers/ saddles including necessary threading/ drilling works complete all as specified and as directed. |