Defence Statutory Bodies & Commissions/Committees Closing in 0 days TDR #45704891

Tender For Special Repairs Replacement Of Ci Pipe Line To Di Pipeline At Pump House Nos 05,10, 11 Along With Allied Works And Provision Of Fire Alarm System At Certain Locations At Af Stn Bamrauli.

Issued by Statutory Bodies & Commissions/Committees · bamrauli, Uttar Pradesh
Tender Value
67.92 Lakhs
Estimated cost
Bid Submission
09 Nov 2024
0 days left
EMD
1.35 Lakhs
Bank guarantee accepted
Document Fee
1000
Non-refundable
Tender Type
Online

Tender Overview

Competition Type
NCB
Bidding Type
Tender
Location / State
bamrauli → Uttar Pradesh
EMD Exemption
Available
Quantity
Not Available

Project Description

Tender For Special Repairs Replacement Of Ci Pipe Line To Di Pipeline At Pump House Nos 05,10, 11 Along With Allied Works And Provision Of Fire Alarm System At Certain Locations At Af Stn Bamrauli.

BOQ

NAME OF WORK: SPL REPAIRS/REPLACEMENT OF CI PIPE LINE TO DI PIPELINE AT PUMP HOUSE NOs 05,10 & 11 ALONGWITH ALLIED WORKS AND PROVN OF FIRE ALARM SYSTEM AT CERTAIN LOCATIONS AT (AF) STN BAMRAULI.
Sl. No. Item Description
1Fire alarm control panel complying with BS EN 54 single loop panel of capacity from 99 detectors& 99 modules upto 200 detector and modules including battery backup system complete as directed by engineer-in -charge
2Detectors complying with and type certified to EN-45 addressable type multisensor detector with heat and smoke combination.
3Supply , installation, testing and comissioning of addressable manual call point resettable type with dust protected design suitable for use in standard environment condition.
4Supply , installation, testing and comissioning of fire alarm sounders/sirens electronic type single stage continuos normal operation for atlest 50 minute with sound level 65 dB to 120 dB measured at 1.5 m with sound output variation of +5dB 500 m range .
5S&F of 2Cx1.5 sqmm FRLS PVC with mylertape insulated copper conductor armoured cable including PVC conduit size 25mm with all fittings and accessories complete all as specified and as directed.
6Supply and fixing factory made epoxy powder coated distribution board SPN 04 ways double door with acrylic top cover (IP-43 protection) fabricated from minimum 1.6 mm thick CRCA sheet and fixed flush to wall and suitable for universal mounting and including 200 Amps copper bus bar, neutral bar, stranded DIN rail, earth bar and cable ties for cable management, top and bottom removable gland plates with Knockouts complete all as specified & directed.
7Supply and fixing MCB single pole & neutral 240 volt \"C\" curve 10 KA 40 to 63 Amps complete all as specified and directed .
8Supply and fixing MCB single pole 240 volt \"C\" curve 10 KA 32 Amps complete all as specified and directed .
9M&L for concealed sub main wiring using two single core PVC insulated, unsheathed stranded copper conductor cable of size 4.0 Sqmm of voltage rating up to and including 1100 volts drawn in and including PVC concealed conduit of dia not less than 25mm with all fittings and accessories, along with one run of PVC (green colour) insulated, unsheathed, stranded copper conductor of size 4.0 Sqmm (green colour) as earth continuity conductor all as specified and directed. (Note : Two runs of single core PVC cable with one run of earth conductor and conduit shall be measured as one unit)
10Supply & laying (in repair) cable XLPE Insulated screened PVC bedded, galvanized steel strip or wire armored, electric power cables (heavy duty) 1100 Volts grade with stranded aluminium conductor using lugs/ferrul both end of cable and testing complete all as directed for following size :-
11(a)16 Sqmm 4 core
12(b) 25 Sqmm 3.5 core
13(c) 35 Sqmm 3.5 core
14Excavation in trenches in soft/loose soil n. exc 1.5 Mtr wide and not exc. 1.5 M deep and getting out including forming bottom surface for laying of pipes complete all as specified and directed.
15Returning filling in including spreading, leveling, watering and well ramming in layers not exc 25 mm thick complete all as specified and directed.
16Removal of excavated material to a distance not exc 50 Meter and depositing wheredirected at a level not exc 1.5 M above the starting point complete all as specified and directed.
17Supplying, laying and cushioning for cable protection in trenches 8 cm deep before laying cable and 15 cm deep over the cable including well punning complete all as specified and dierected
18Supplying, laying sub class \"B\" bricks old size with axis of the bricks perpendicularto the axis of the cable as in cable protection complete all as specified and directed.
19Supply & Fixingin replacement GI tubing light grade in trenches/fixed to wall/ceiling including required GI fitting of size 40mm dia complete all as specified and directed
20Excavation insoft/loose soil trenches not exceeding 1.5 mtr wide and not exceeding 1.5 mtr deep and getting out incl old U/s cable cover of ant type , taking out/laying/cleaning/repairing of CI/GI pipe line, cable etcincluding making good to disturbed surfacescomplete all as specified and directed.
21Returning, filling in & including spreading, levelling& well ramming in layers not exceeding 25 cm thick as in soft/loose soil complete all as specified and directed.
22Removal of surplus spoil to a distance not exceeding 50 mtr depositing where directed at a level not exceeding 1.5 mtr above ground levelcomplete all as specified and directed.
23Excavation in hard standing for crossing the road as per the authorized width for taking out/laying/cleaning/repairingof CI/GI pipe lines all as directed including making good the road cut to match with the existing surface either with bituminous macadam or with PCC 1:2:4, type B-2(using 40mm graded crushed stone aggregate) complete all as specified and directed.
24Taking up unserviceable CI/DI rusted/ broken pipe line (including all fittings) with spigot and socket/ Flanged ends and removal from site including burning out joints and recovering lead complete all as specified and directed for the following sizes/bores of pipes :-(Earth work shall be measured and paid separately).
25(a) 150mm bore dia
26(b) 100mm bore dia
27Laying only in trenches CI pipe with spigot and socketed ends complete after cleaning properly/thoroughly & removal of all blockage removing all silt and deposited organics inside using bamboo or rod with brush complete all as specified and directed for the following sizes/bore of pipes :-
28(a) 150mm bore dia
29(b) 100mm bore dia
30Supply & laying in trenches ductile iron (DI) pipe with spigot and socketed ends centrifugally cast class \"K-7\" in any length laid in trenches complete all as specified and directed for the following sizes/bore of pipes (DI fittings and jointing materials shall be measured and paid separately) :-
31(a) 150 mm bore dia
32(b) 100 mm bore dia
33M&L for cutting ofthe CI/DI pipe in position for insert of new tee, branches such as Tees/Reducers/Tail pieces/collers/sluice valve/Air release valve etc.with suitable size of clamp of size 40 x 6 mm with nuts, bolts and washer of the following sizes complete all as specified and directed:-
34(a) 150 mm bore
35(b) 100 mm bore
36M&L for rubber gasket joint suitable for DI pipe and fittings withsize of nuts, washer & bolts etccomplete all as specified and directed forthe following sizes :-
37(a) 150 mm bore
38(b) 100 mm bore
39M&L for upto 150 mm bore ductileiron (DI) fittings such as bends (any type, radius and angle) tapers any type,(straight, bend, increasing, decreasing or double socket etc) tee pieces single branch, “Y” junction, double branch, cross (all sockets or socket and spigot) collars, flanged spigot,caps and plugs complete all as specified and directed.
40Taking up or down steel water tubing and connections including clearing the pipes free from scaling for reusing the same complete all as directedfor the following sizes :-Note :-Excavation will be measured and paid separately
41(a) 50 mm dia bore
42(b) 40mm dia bore
43(c) 25 mm dia bore
44(d) 20 mm dia bore
45(e) 15 mm dia bore
46Relaying/ refixing of old steel tubing and connection in new or old position including necessary cuttings, threading, and new fittings such as bends, elbows, socket nipples, tapers, and reducers etc all as specified and directed
47(a) 50 mm dia bore
48(b) 40 mm dia bore
49(c) 25 mm dia bore
50(d) 20 mm dia bore
51(e) 15 mm dia bore
52Supply and lay steel water tubing GI medium grade ISI marked with all fittings laid in trenches or fixed to wall etc complete for the following sizes:-Make: Jindal/Prakash/Swastik Note :- Excavation and earth work will be measured and paid separately.
53(a) 50 mm dia bore
54(b) 40 mm dia bore
55(c) 25 mm dia bore
56(d) 20 mm dia bore
57(e) 15 mm dia bore
58S&F Gun metal gate valve ISI marked with iron wheel head screwed both ends for iron pipes and fixed for the following sizes including taking down of unserviceable gate valves.Make : Zoloto/Seico/Jindal/Upadhaya/Venus
59(a)50 mm bore
60(b) 40 mm bore
61(c) 25 mm bore
62(d) 20 mm bore
63(e) 15 mm bore
64S&F 15 mm dia PVC bib tap with crutch handle screwed down screwed for iron pipe including taking out unserviceable tape of 15mm dia complete all as specified and directed.
65Supply, fixing, jointing and testing in repair of cast iron sluice valve class I(ISI MARKED) PN-1.6 typelatest IS 14846-2000 flanged ends, drilled having stainless steelspindle with cast iron wheel head at top complete with nuts, bolts, washer and rubber gasket etc complete including taking down unserviceable sluice valve completeall as specified and directed for following bore of CI pipe line :-
66(a)150 mm dia bore
67(b)100 mm dia bore
68Dismantling old broken / damaged valve pit chamberand construct valve pitchamber of size 1050mm x 1050 mm x 1050 mm (internal dimention) complete including excavation and earth work, PCC 1:4:8, type D-2 using 40mm graded stone aggregate, brick work in cement mortar 1:6, plastering in cement mortar 1:4 (internally) and including 3mm thick mild steel sheet cover and painting with two coat of synthetic enamel paint over a coat of red oxide primer complete all as specified and directed.
69All as per item No 18 above but size of valve chamber is 900 x 900 x 900 mm (internal) and all as specified and directed.
70S&F in replacement of service outlet having two half clamp made out of MS strip of 6 mm thick with nut bolt and rubber sealing ring suitable to fit for PVC pipe, the out let shall be threaded 40 mm size to suit the inlet of hydraunt complete all as specified and directed.

AI Tender Summary

OUR REF NO 45704891
AUTHORITY Statutory Bodies & Commissions/Committees
TENDER VALUE 67.92 Lakhs
LAST DATE 09-11-2024
Authority
Authority Name Military Engineer Services
Work Description Tender For Special Repairs Replacement Of Ci Pipe Line To Di Pipeline At Pump House Nos 05,10, 11 Along With Allied Works And Provision Of Fire Alarm System At Certain Locations At Af Stn Bamrauli.
Basic Detail
Tender No 87431/C/E8
Bidding Type Tender
Location
City bamrauli
State Uttar Pradesh
Key Dates
Publish Date 11 Oct 2024
Submission Date 09 Nov 2024
Open Date 16 Nov 2024
Finance
Tender Value 67.92 Lakhs
Tender Fee 1000
EMD 1.35 Lakhs
Exemption Available
Document List
a5bd7ffa-bcbc-43c5-a8d7-d5f46eb7f656.html
87431TENDERDOCUMENT.rar
BOQ_759741.xls
Tendernotice_1.pdf

Unlock Full AI Tender Summary

Get instant access to the complete AI-generated analysis — scope, eligibility, timeline & more.

Instant Access Secure Free
Your details are secure and used only for document delivery.

Tender Timeline

Oct 11, 2024
11:30 IST

Tender Published

Tender notice published.

Completed
Nov 09, 2024
17:00 IST

Bid Submission Deadline

Online submission via eProcurement portal.

Completed
Nov 16, 2024

Bid Opening Date

Technical bids will be opened and evaluated.