| 1 | Dismantling posts or struts (wood, steel or R.C.C.) any section, including taking out embedded portion of concrete above GL or below GL complete all as specified and directed |
| 2 | Excavating in post holes or similar holes in dismantled posts or struts each n.exc 0.5 Cum, getting out, returning, filling in and ramming earth or broken rubble mixed with earth around, in layers not exceeding 25cm, watering and removing surplus soil to a distance n exc 50m and making good surface in soft/loose soil/cement concrete complete all as specified and directed. |
| 3 | M & L for PCC 1:2:4 type B-1, using 20 mm graded stone agg as in foundation, complete all as specified and directed. |
| 4 | Demolition of cement conc.,reinforced cement concrete,RCC Jalli of any description and in any position not otherwise specifically provided for complete all as specified and directed. |
| 5 | M&L for PCC1:2:4 type B-0 using 12.5mm graded stone aggregate as in copping,plinth course,bed plates and the like including necessary use and waste of formwork complete all as specified and directed. |
| 6 | M&L Providing reinforced cement concrete type B-l, 1:2:4 (20 mm graded aggregate) in precast posts, fencing posts, straining or terminal posts, struts etc. for fencing, average sectional area n exc 100 sq. cm, with or without chamfered angles and flat, splayed, rounded or mitred tops as directed and fixed complete all as specified and directed. |
| 7 | M & L Providing precast cement concrete louvres and jalliestype B-0, 1:2:4 (12.5 mm graded aggregate) 25mm thick (measured solid),set in CM 1:4. including all mouldings complete all as specified and directed. |
| 8 | Dismantling steel wrought iron or mild steel work of any description complete all as specified and directed. |
| 9 | S & F Mild steel round bars 6 to 8mm dia, cut to length, bent to shape required, including cranking, bending spirally for hooping for columns, hooking ends and binding with and including mild steel wire (annealed) not less than 0.9mm dia or securing with clips of Fe-410-W (Gde.E-250) quality-A or Fe 290 (Gde - E-165) complete used in reinforcement & fencing complete all as specified and directed. |
| 10 | M&L in applying two coats of synthetic enamel paints over a coat of red oxideprimer on new steel surfaces over 10 cm width or girth including preparatinon of surfaces complete all as specified and directed. |
| 11 | M&L for preparation of old surfaces and applying one coat of synthetic enamel paint on surfaces over 10 cm width or girth complete all as specified and directed.Note : The painting is to be done on steel sections fixed on boundary wall/gates/doors and similar places complete all as specified and directed. |
| 12 | Dismantling chain link fencing any type complete all as specified and directed. |
| 13 | Supply & Fixing 3\"\" x 3\"\" (75mmx75mm) mesh size & 3.4 mm dia of wire chain link MS galvanised fencing complete including line wires, rails, straining bolts etc, including provision of binding wire complete all as specified and directed. |
| 14 | S & F Rolled Mild Steel Framed work as in doors or Gates, fencing post, support on wall of angle or other section confirming to Fe 410 -W (Gde-, E- 250) A quality-with gusset plates, rails braces, etc., complete, drilled for fixing of steel sheeting or other covering and hanging and fixing complete all as specified and directed. |
| 15 | S & F 0.80 mm thick Mild Steel Plain, black sheet in Chullah hood, covering to door shutters, ducts, etc., cut to size, holes punched including fixing to MS clamps with necessary bolts and nuts complete all as specified and directed. |
| 16 | Dismantling/Removing of existing barbed wire/razor wire of any descreption/pattern complete all as specified and directed. Note: Each line of wire measured. |
| 17 | S&F galvanised 2 strand steel barbed wire 2.24mm dia barbed with 2mm dia barbs at 75 mm spacing and straining and fixing to any type of standard rails straining bolts including securing or tying at crossings with and provision of galvanised complete all as specified and directed. |
| 18 | Restraining and resecuring including making good staples etc.of galvanised steel barbed wire of any type straining and fixing to any type of standard rails straining bolts including securing or tying and including iron clips etc. as requiered for tying barbed wire complete all as specified and directed. |
| 19 | Dismantling /Removing or taking down of existing CONCERTINA COIL any size/descreption/pattern complete all as specified and directed. |
| 20 | Supply and fixing concertina coil 610mm dia (in stretched position) hot dip galvanized steel wiremaking diamond shape with the help of dove tail clips (18 SWG) fixed over razor wire/barbed wire with existing angle iron complete all as specified and directed. |
| 21 | Fixing only concertina coil 610mm dia (in stretched position) hot dip galvanized steel wiremaking diamond shape with the help of dove tail clips (18 SWG) fixed over razor wire/barbed wire with existing angle iron.complete all as specified and directed. Note: concertina coil will be use from above taking down item. |
| 22 | Supply and fixing concertina coil 1050mm dia (in stretched position) hot dip galvanized steel wiremaking diamond shape with the help of dove tail clips (18 SWG) fixed over razor wire/barbed wire with existing angle iron. |
| 23 | Fixing only concertina coil 1050mm dia (in stretched position) hot dip galvanized steel wiremaking diamond shape with the help of dove tail clips (18 SWG) fixed over razor wire/barbed wire with existing angle iron. Note: concertina coil will be use from above taking down item. |
| 24 | Demolition of brickwork built in cement mortar or cement lime mortar complete all as specified and directed. |
| 25 | M&L brick work with sub class \"B\" bricks, straight or curved on plan exc. 6 mtr mean radius built in CM(1:6) complete all as specified and directed. |
| 26 | Taking down cement plaster on brick/stone surface of wall/RCC wall built in cement mortar including racking out joints, hacking for key, scrubbing down with water etc. complete all as specified and directed. |
| 27 | M & L for rendering 15 mm thick on fair face of brick walls or concrete surface in CM 1:4surface fair and even complete all as specified and directed. |
| 28 | M & L preparation of new plastered surfaces on walls and applying two coats of cement base paintscomplete all as specified and directed. |
| 29 | M & L for 75mm thick PCC type C-2, 1:3:6 (40 mm graded aggregate) in plinth protection, floor and similar including necessary use and waste of formwork complete all as specified and directed. |
| 30 | Note :- (i) Credit shown in credit schedule of tender document shall be considered by the tenderer while quoting the rates of various items. The same shall be recovered from various payment to contractor before handing over old material. The contract amount shall be arrived at after deduction of Schedule of Credit from the total quoted amount in BOQ.(ii) Make of material shall be as per mentioned in Particular specifications or Appendix \"B\" to Particular specifications as approved by AGE (I) AF manauri |